The aging correlation (RH + t): Relative humidity (%) + temperature (deg C)

An aging correlation between corrosion lifetime, and relative humidity RH (%) and temperature t (C) has been reported in the literature. This aging correlation is a semi-log plot of corrosion lifetime on the log scale versus the interesting summation term RH(%) + t(C) on the linear scale. This empirical correlation was derived from observation of experimental data trends and has been referred to as an experimental law. Using electrical resistivity data of polyvinyl butyral (PVB) measured as a function of relative humidity and temperature, it was found that the electrical resistivity could be expressed as a function of the term RH(%) t(C). Thus, if corrosion is related to leakage current through an organic insulator, which, in turn, is a function of RH and t, then some partial theoretical validity for the correlation is indicated. This article describes the derivation of the term RH(%) t(C) from PVB electrical resistivity data.

Cuddihy, E. F.↗

The (RH+t) aging correlation. Electrical resistivity of PVB at various temperatures and relative humidities

Electrical products having organic materials functioning as pottants, encapsulants, and insulation coatings are commonly exposed to elevated conditions of temperature and humidity. In order to assess service life potential from this method of accelerated aging, it was empirically observed that service life seems proportional to an aging correlation which is the sum of temperature in degrees Celsius (t), and the relative humidity (RH) expressed in percent. Specifically, the correlation involves a plot of time-to-failure on a log scale versus the variable RH + T plotted on a linear scale. A theoretical foundation is provided for this empirically observed correlation by pointing out that the correlation actually involves a relationship between the electrical resistivity (or conductivity) of the organic material, and the variable RH + t. If time-to-failure is a result of total number of coulombs conducted through the organic material, then the correlation of resistivity versus RH + t is synonymous with the empirical correlation of time-to-failure versus RH + t.

Cuddihy, E. F.↗

Utilization of Airborne Observations to Assess Model Parametrizations of Critical RH Profiles in the Arctic Ocean

Observational paucity is a reality in the Arctic Ocean. This is especially true for near-surface variables such as temperature, moisture, heat fluxes and BL clouds. As a result, modeling has become one of the major avenues for understanding current and future Arctic trends. Reanalyses are frequently used to force global ocean circulation and sea-ice models. But in northern high latitudes, model integrations and reanalyses are known to have large uncertainties in temperature and humidity profiles, and in boundary layer cloudiness. These are common sources of error in the surface radiative budget terms.An important way to diagnose these biases spatially and temporally is by using satellite remote sensing data. However, remotely-sensed observations also have large uncertainties, especially in near-surface temperature and relative humidity profiles.In situ observational studies are important in bridging our knowledge gap in regions such as the Arctic Ocean. Here, we utilize airborne and ship observations from the ARISE, ACME-IV, and ASCOS campaigns to construct critical relative humidity (RH) profiles over the Beaufort Sea. Such profiles are used as parameterization inputs in the NASA GOES global model to derive the total water condensate in a model grid-box, which determines the cloud fraction. Currently, the critical RH profiles are derived by global AIRS data, relaying mostly on mid-latitude regions, which are not necessarily relevant to the Arctic.We derive campaign-wide mean, standard deviation, and critical RH values, for grid size of 50x50 km and altitude bins between 50 to 400 m, covering both open-ocean and sea-ice covered regions. We compare profiles over open ocean and sea-ice, and look at correlations between the observed critical RH values and water condensate (by cloud number concentration) from observations versus the modeled ones. We then input our calculated values of minimal critical RH values into a set of GEOS single column model (SCM) simulations over the ARISE and ASCOS regions and compare the differences between the predicted values of cloud liquid water path (LWP), ice water path (IWP) and surface fluxes with the observed ones under the range of input parameterizations. Finally, we discuss the implications on surface radiative budget predictions in this region.

Segal-Rozenhaimer, Michal↗

Surface sticking probabilities for sputtered atoms of Nb-93 and Rh-103

The capture coefficient probabilities for sputtered atoms of Nb-93 and Rh-103 incident on Al2O3 surfaces were measured using the backscattering of MeV heavy ions. In the circumstance where the collecting surface is thickly covered, the sticking probabilities integrated over the energy distribution of sputtered atoms are 0.97 plus or minus 0.01 for Nb-93 and 0.95 plus or minus 0.01 for Rh-103 respectively. In the limit of negligible areal coverage of the collector, the accuracy is less; in this case the sticking probabilities are 0.97 + 0.03 or -0.08 and 0.95 + 0.05 or -0.08.

Weller, M. R.↗

Intracellular mechanism of the action of inhibin on the secretion of follicular stimulating hormone and of luteinizing hormone induced by LH-RH in vitro

The FSH secretion-inhibiting action of inhibin in vitro under basal conditions and also in the presence of LH-RH is suppressed by the addition of MIX, a phosphodiesterase inhibitor. In the presence of LH-RH, inhibin reduces significantly the intracellular level of cAMP in isolated pituitary cells. In contrast, the simultaneous addition of MIX and inhibin raises the cAMP level, and this stimulation is comparable to the increase observed when MIX is added alone. These observations suggest that one mode of action of inhibin could be mediated by a reduction in cAMP within the pituitary gonadotropic cell.

Lecomte-Yerna, M. J.↗

The Nd-Rh system

Phase diagram of Nd-Rh system determined by powder X ray diffraction, metallography and differential thermal analysis methods

Raman, A.↗

Synthesis Of Ir(1-x-y)Rh(x)Co(y)Sb(3) Semiconductors

Ir(1-x-y)Rh(x)Co(y)Sb(3) semiconductors synthesized by gradient-freeze and sintering techniques. Sintering techniques used for variety of compositions; gradient-freeze technique used for RhSb(3) and CoSb(3).

Caillat, Thierry↗

Vorago RH-OBC-1 Single Event Effect Characterization Test Report

The Vorago Technologies RH-OBC-1 is a CubeSat Kit Bus compatible single board computer with a Vorago VA10820 ARM Cortex-M0 microcontroller at its core. The board also includes a set of common peripheral integrated circuits, like voltage regulators, non-volatile memories (NVM), an analog-to-digital converter (ADC), a watchdog/supervisor, and a Controller Area Network (CAN) bus transceiver. High-energy proton (200 MeV) testing was conducted at both board and component levels to investigate single-event effects.

CubeSat compatible board↗

UV-T-RH combined environmental testing

A combined environmental aging chamber was developed at the Jet Propulsion Laboratory (JPL). The chamber has an ultraviolet (UV) light source that can be varied between 1 to 2 suns, temperature control from -40 to +175 C, and adjustable humidity. Results from two initial aging experiments (Tedlar and amorphous silicon colar cells) were presented.

Gonzalez, C. C.↗

Cloud Detection Using Measured and Modeled State Parameters

In this study, hourly RUC analyses were used to examine the differences between RH and temperature values from RUC reanalysis data and from radiosonde atmospheric profiles obtained at the ARM SCF. The results show that the temperature observations from the SONDE and RUC are highly correlated. The RHs are also well-correlated, but the SONDE values generally exceed those from RUC. Inside cloud layers, the RH from RUC is 2-14% lower than the RH from SONDE for all RUC layers. Although the layer mean RH within clouds is much greater than the layer mean RH outside cloud or in the clear-sky, RH thresholds chosen as a function of temperature can more accurately diagnose cloud occurrence for either dataset. For overcast clouds, it was found that the 50% probability RH threshold for diagnosing a cloud, within a given upper tropospheric layer is roughly 90% for the Vaisala RS80-15LH radisonde and 80% for RUC data. While for the partial cloud (cloud amount is less than 90%), the RH thresholds of SONDE are close to RUC for a given probability in upper tropospheric layers. The probabilities of detecting clouds at a given RH and temperature should be useful for a variety of application such as the development of new cloud parameterizations or for estimating the vertical profile of cloudiness underneath a given cloud observed from the satellite to construct a 3-D cloud data set for computing atmospheric radiative heating profiles or determining potential aircraft icing conditions.

Yi, Y.↗

Nonlinear evolution of high frequency R-mode waves excited by water group ions near comets - Computer experiments

An ion beam resonates with R-mode waves at a high-frequency RH mode and a low-frequency RL mode. The nonlinear evolution of ion beam-generated RH waves is studied here by one-dimensional hybrid computer experiments. Both wave-particle and subsequent wave-wave interactions are examined. The competing process among coexisting RH and RL mode beam instabilities and repeated decay instabilities triggered by the beam-excited RH mode waves is clarified. It is found that the quenching of the RH instability is not caused by a thermal spreading of the ion beam, but by the nonlinear wave-wave coupling process. The growing RH waves become unstable against the decay instability. This instability involves a backward-traveling RH electromagnetic wave and a forward-traveling longitudinal sound wave. The inverse cascading process is found to occur faster than the growth of the RL mode. Wave spectra decaying from the RH waves weaken as time elapses and the RL mode waves become dominant at the end of the computer experiment.

Kojima, H.↗

Subsurface Cl-bearing salts as potential contributors to recurring slope lineae (RSL) on Mars

We report laboratory experimental results that support a brine-related hypothesis for the recurring slope lineae (RSL) on Mars in which the subsurface Cl-salts, i.e., hydrous chlorides and oxychlorine salts (HyCOS) are the potential source materials. Our experiments revealed that within the observed RSL temperature window TRSL (250–300 K), the deliquescence of HyCOS could occur in relative humidity ranges (RH≥22%–46%) much lower than those for hydrous (Mg, Fe)-sulfates (RH≥75%–96%). In addition, we demonstrated that the RH values kept by common HyCOS and hydrous sulfates in enclosures have a general trend as RH(sulfates) > RH(perchlorates) > RH(chlorides) (with same type of cation) in wide T range. It means that the required RH range for a Cl-bearing salt to deliquescence can be satisfied by a co-existing salt of different type, e.g., in the subsurface layers of mixed salts on Mars. Furthermore, we found a strong temperature dependence of the deliquescence rates for all tested HyCOS, e.g., a duration of 1–5 sols for all HyCOS at the high end (300 K) of TRSL, and of 20–70 sols for all tested HyCOS (except NaClO4·H2O) at the low end (250 K) of TRSL, which is consistent with the observed seasonal behavior of RSL on Mars. From a mass-balance point of view, the currently observed evidences on Mars do not support a fully-brine-wetted track model, thus we suggest a brine-triggered granular-flow model for the most RSL. Considering the recurrence of RSL in consecutive martian years, our experimental results support the rehydration of remnant HyCOS layers during a martian cold season through H2O vapor-to-salt direct interaction. We found that the evidences of HyCOS rehydration under Mars relevant P-T-RH conditions are detectable in a few minutes by in situ Raman spectroscopy. This rehydration would facilitate the recharge of H2O back into subsurface HyCOS, which could serve as the source material to trigger RSL in a subsequent warm season. The major limiting factor for this rehydration is the H2O supply, i.e., the H2O vapor density carried by current Mars atmospheric circulation and the diffusion rate of H2O vapor into the salt-rich subsurface in a cold season. In a worst-case scenario, these H2O supplies can support a maximum increase of hydration degrees of two for totally dehydrated HyCOS, whereas the full rehydration of subsurface HyCOS layers can be easily reached during a>30° obliquity period that has H2O vapor density 10× to 20× times the value of current obliquity. Overall, our results imply the existence of a large amount of Cl-bearing salts in the subsurface at RSL sites.

Alian Wang↗

Combined Experimental and Modeling Study of the Interactions of Acid Gas with Common Spacecraft Surfaces for Fire Safety Applications

A fire in a spacecraft poses detrimental consequences and risks mission success in addition to crew safety. This is compounded during long-duration missions when the crew has limited options to recover from a fire. A common spacecraft fire concern is the smoldering of wire insulation, typically made from Polyvinyl chloride (PVC) or Polytetrafluoroethylene (PTFE). This creates acid gases such as Hydrogen Chloride (HCl), Hydrogen Fluoride (HF) and Hydrogen Cyanide (HCN). These poisonous gases are hazardous to the crew. They also interact with common surfaces within the spacecraft more than dominant combustion products such as CO2 and H2O. This makes them more difficult to track for potential fire detection techniques, or for postfire clean-up. It is imperative to be able to understand and predict the fate of these poisonous species in a microgravity environment in order to design a safe vehicle. HCl interacts with a number of materials inside a spacecraft. Primary among these materials is aluminum, which is abundantly used due to its strong and light weight nature. Aluminum has a natural oxide layer that protects it from corrosion but is typically treated to enhance this oxide layer. Among these treatments is a chromate conversion coating (CCC), which provides a thin enough protective oxide layer to still conduct electricity, and a traditional anodized material that has a thicker oxide layer that does not conduct electricity. Nomex is another common material found inside a spacecraft. It is a flame-resistant woven polymer that is related to nylon. This commercially available material is used for cargo storage bags and as a fire barrier. Physics-based models were developed to predict the uptake of HCl by these materials. The ultimate objective of these models is to predict the fate of HCl within the spacecraft so that sensors can be placed in meaningful locations in future missions based on the model predictions. To support these modeling efforts, experiments were performed in a cast acrylic test cell that measured the difference between the inlet and outlet concentration of HCl after inserting a sample rod of the test material. Different uptake capacities were realized for each type of sample tested. A computational fluid dynamics model (CFD) model of the reactor was then constructed that used a one-step global reaction rate with calibratable reaction (or kinetic) constants. These constants were calibrated to match the HCl uptake on the CCC aluminum samples, and the same kinetic constants were then tested for the stock and anodized aluminum samples. Model predictions matched the experimental data for the stock aluminum, and to a much lesser extent, the anodized aluminum. The model was additionally validated at different flow rates, sample surface areas, and inlet concentrations, and showed good agreement for all stock and CCC samples. The model did not accurately predict the HCl uptake in the anodized samples compared to the other two types of aluminum. Adjusting the kinetic constants and transport properties did little to improve the prediction. X-Ray Photoelectron Spectroscopy (XPS) was used to determine that the oxide layer thickness of anodized aluminum is approximately 5,000 nm, compared to 250 nm for CCC and 50 nm for stock. XPS also revealed presence of chlorine further down in the aluminum oxide layer in anodized samples than CCC and stock samples after the samples were saturated with HCl, indicating that accounting for diffusion of HCl into the oxide layer is important for accurate prediction of HCl uptake onto anodized aluminum. Consequently, a multi-scale model was developed and tested. First, a single pore inside the anodized aluminum oxide layer was modeled and is referred to as the pore-scale model. In this model, HCl diffused through the pore and reacted with the aluminum oxide pore wall to create aluminum chloride. The sample was then saturated when the mass transfer resistance through the growing aluminum chloride layer became too large for the HCl to reach the aluminum oxide wall and continue the reaction. This pore-scale model was coupled to the reactor-scale model using a concentration-dependent diffusion coefficient, resulting in much more accurate predictions (approximately half the sum square error of the aforementioned reactor-scale model that produced good agreement for stock and CCC) for a variety of operating conditions. The amount of water vapor or relative humidity (RH) in the flow during a reactor experiment was determined to influence HCl uptake. Experiments were performed to understand the interaction of gaseous HCl with aluminum surfaces in the presence of water vapor. The results show that increasing levels of RH increased the capacity of aluminum to adsorb HCl but decreased the capacity of Nomex to uptake HCl. A series of tests were performed on individual aluminum samples after they had been saturated with a fixed concentration of HCl in dry air conditions with the goal of determining how their HCl uptake capacity changes after various treatments with water relative to the original saturation tests. HCl-saturated aluminum samples subjected to a second dry air flow at the same HCl concentration as the original test had an uptake of 23.5% of the original sample with no treatment in between. Saturated aluminum samples subjected to an air flow with a RH of 90% in between tests had an uptake of 35.6% of the original. Saturated aluminum samples submerged in distilled water for 12 hours in between tests had an uptake of 82.2% of the original sample. Previously saturated aluminum tested with HCl and a 50% RH air flow resulted in similar uptake characteristics in multiple repeated tests. The experiments show the profound effect water vapor has on HCl uptake onto aluminum surfaces. In the samples subjected to water vapor or liquid water, capillary condensation and capillary diffusion alters the transport of HCl significantly. A model was proposed that developed a relationship between RH and the coefficient of HCl diffusion in aluminum chloride. This produced an “S-shaped” curve with diffusion coefficient as a function of RH, with 45% RH represented as the point where the diffusion coefficient is halfway between no water saturation and 100% water saturation in the aluminum chloride product layer. No difference in uptake characteristics for the experiment or model were realized between 50% and 62% RH. The results from the large-scale microgravity experiment, Saffire, are discussed as they pertain to the fate of HCl throughout a spacecraft. HCl was released, both as a standalone event, and in concurrence with the burning of a structured cloth. These events only produced a small response in the far field HCl sensor, while a PMMA burn that did not produce HCl had a significantly greater response. A ground-based large-scale facility was constructed to flow acid gas at the scale and configuration realized in the Saffire experiments. A CFD model of this duct was constructed to test kinetic parameters developed in this work at a larger scale and different geometric configuration and to predict the results of the large-scale facility. The models developed in this work were used to interpret the results of the microgravity tests and lead the discussion on what further experiments and models are needed in order to predict the fate of acid gas in a spacecraft environment. To summarize, the major contributions of this work are as follows: the capacity to uptake HCl, with and without the presence of water vapor, was measured for a variety of real spacecraft surfaces. Several different models (single reactor-scale, multiscale, spacecraft-scale) were developed and with the aid of modeling, the rate of uptake for those surfaces was also predicted and validated. The kinetic parameters determined from the small-scale reactor experiments and models were used to predict large-scale and microgravity tests. Conclusions from this research will be used in the design of spacecraft vehicles and large-scale microgravity fire safety experiments. The models built by this work will aid designers in sensor placement and could be used to predict acid gas transport from fires in partial gravity, as would be seen in Lunar and Martian habitats.

fire safety↗

Intensity of hydrostimulation for the induction of root hydrotropism and its sensing by the root cap

Roots of Pisum sativum L. and Zea mays L. were exposed to different moisture gradients established by placing both wet cheesecloth (hydrostimulant) and saturated aqueous solutions of various salts in a closed chamber. Atmospheric conditions with different relative humidity (RH) in a range between 98 and 86% RH were obtained at root level, 2 to 3mm from the water-saturated hydrostimulant. Roots of Silver Queen corn placed vertically with the tips down curved sideways toward the hydrostimulant in response to approximately 94% RH but did not respond positively to RH higher than approximately 95%. The positive hydrotropic response increased linearly as RH was lowered from 95 to 90%. A maximum response was observed at RH between 90 and 86%. However, RH required for the induction of hydrotropism as well as the responsiveness differed among plant species used; gravitropically sensitive roots appeared to require a somewhat greater moisture gradient for the induction of hydrotropism. Decapped roots of corn failed to curve hydrotropically, suggesting the root cap as a major site of hydrosensing.

NASA Discipline Plant Biology↗

Comparison Between Lidar and Nephelometer Measurements of Aerosol Hygroscopicity at the Southern Great Plains Atmospheric Radiation Measurement Site

Aerosol hygroscopicity has a significant effect on radiative properties of aerosols. Here a lidar method, applicable to cloud-capped, well-mixed atmospheric boundary layers, is employed to determine the hygroscopic growth factor f(RH) under unperturbed, ambient atmospheric conditions. The data used for the analysis were collected under a wide range of atmospheric aerosol levels during both routine measurement periods and during the intensive operations period (IOP) in May 2003 at the Southern Great Plains (SGP) Climate Research Facility in Oklahoma, USA, as part of the Atmospheric Radiation Measurement (ARM) program. There is a good correlation (approx. 0.7) between a lidar-derived growth factor (measured over the range 85% RH to 96% RH) with a nephelometer-derived growth factor measured over the RH range 40% to 85%. For these RH ranges, the slope of the lidar-derived growth factor is much steeper than that of the nephelometer-derived growth factor, reflecting the rapid increase in particle size with increasing RH. The results are corroborated by aerosol model calculations of lidar and nephelometer equivalent f(RH) based on in situ aerosol size and composition measurements during the IOP. It is suggested that the lidar method can provide useful measurements of the dependence of aerosol optical properties on relative humidity, and under conditions closer to saturation than can currently be achieved with humidified nephelometers.

Pahlow, M.↗