Validating and Comparing Energy Estimation Methods at Water Resource Recovery Facilities
Water resource recovery facilities play a crucial role in the water-energy nexus, consuming a substantial amount of energy in the United States. Growing treatment volumes and more stringent water quality standards are expected to increase the amount of energy needed to treat wastewater, but accurately estimating energy consumption and potential remains challenging due to variability in scale, treatment methods, and effluent treatment standards. In this study, we used publicly available data to evaluate the accuracy of methods for estimating energy consumption and generation, then quantified uncertainty based on key factors like flow rate, treatment level, and geographic location. To validate methods, we estimated energy consumption and generation at the facility-level, then compared estimates to self-reported data from utilities in major U.S. cities. We found that process models of treatment trains under best practice configurations were accurate relative to other methods for estimating electricity use, total energy use, and electricity generation from biogas utilization, and less complex methods based on effluent treatment level and prime movers also performed well for estimating electricity consumption and generation, respectively. Applying the evaluated methods to a national inventory of treatment facilities, we estimate that annual energy consumption ranged from 56.3 x 10^3 to 82.5 x 10^3 TJ in 2012 and 83.6 x 10^3 to 127 x 10^3 TJ in 2042. Our results indicate that not all estimation methods are suited for every use case, so we recommend that researchers and practitioners select an estimation method based on data availability and desired computational intensity.