Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Recovery analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Gravity recovery analysis using GPS for STEP and a low-low satellite mission

Global Positioning System (GPS) receivers on low Earth orbiting satellites can provide three-dimensional global tracking with sub-decimeter orbit accuracy. The precise GPS data can additionally be used to refine the Earth's gravity field. Satellite Test of the Equivalence Principle (STEP) is a proposed European Space Agency mission which will carry a flight GPS receiver. Using a realistic scenario for processing 5 days of GPS data, a covariance analysis is performed to obtain the expected improvement in the gravity field. Additionally, a similar analysis is then repeated for two low Earth orbiting satellites, each equipped with GPS receivers and with precise ranging measurements between them.

Muellerschroen, Ronald J.

EVALUATION OF HRA METHODOLOGIES FOR APPLICATION IN SDP WORK

This study critically evaluates human reliability analysis (HRA) methodologies applicable to regulatory probabilistic safety assessment (PSA) model, with a particular focus on their role in supporting the significance determination process (SDP) in nuclear safety assessment. Firstly, three widely utilized HRA methods – IDHEAS-ECA, SPAR-H, and ASEP/THERP – were qualitatively and quantitatively assessed. Qualitative assessments were conducted using attributes from the NEA/CSNI/R(2015)1 report, while quantitative evaluations employed regression and correlation analyses to compare predicted human error probabilities (HEPs) against empirical data. Results reveal distinct strengths, for example, IDHEAS-ECA’s robust predictive accuracy and K-HRA’s alignment with operational practices. In addition, dependency analysis and recovery analysis were critically evaluated. For dependency analysis, the methods’ handling of inter-task dependencies and their impact on HEPs were examined, while recovery analysis highlighted strategies for mitigating failure events. Furthermore, strategies were proposed to evaluate performance-shaping factors under conditions of reduced human performance, such as stress, fatigue, or cognitive overload, addressing specific challenges faced in SDP evaluations. Human errors from KINS’s operational performance information system event reports were evaluated as a case study. This study identifies gaps and provides actionable insights to ensure their validity and applicability in SDP HRA applications. This paper is a part of research conducted by KINS, and it should be noted that this result does not represent the regulatory position of KINS.

99 - GENERAL AND MISCELLANEOUS

Abundance recovery error analysis using simulated AVIRIS data

Measurement noise and imperfect atmospheric correction translate directly into errors in the determination of the surficial abundance of materials from imaging spectrometer data. The effects of errors on abundance recovery were investigated previously using Monte Carlo simulation methods by Sabol et. al. The drawback of the Monte Carlo approach is that thousands of trials are needed to develop good statistics on the probable error in abundance recovery. This computational burden invariably limits the number of scenarios of interest that can practically be investigated. A more efficient approach is based on covariance analysis. The covariance analysis approach expresses errors in abundance as a function of noise in the spectral measurements and provides a closed form result eliminating the need for multiple trials. Monte Carlo simulation and covariance analysis are used to predict confidence limits for abundance recovery for a scenario which is modeled as being derived from Airborne Visible/Infrared Imaging Spectrometer (AVIRIS).

Stoner, William W.

Earth recovery mode analysis for a Martian sample return mission

The analysis has concerned itself with evaluating alternative methods of recovering a sample module from a trans-earth trajectory originating in the vicinity of Mars. The major modes evaluated are: (1) direct atmospheric entry from trans-earth trajectory; (2) earth orbit insertion by retropropulsion; and (3) atmospheric braking to a capture orbit. In addition, the question of guided vs. unguided entry vehicles was considered, as well as alternative methods of recovery after orbit insertion for modes (2) and (3). A summary of results and conclusions is presented. Analytical results for aerodynamic and propulsive maneuvering vehicles are discussed. System performance requirements and alternatives for inertial systems implementation are also discussed. Orbital recovery operations and further studies required to resolve the recovery mode issue are described.

Green, J. P.

Focused Ion Beam Recovery and Analysis of Interplanetary Dust Particles (IDPs) and Stardust Analogues

Meteoritics research is a major beneficiary of recent developments in analytical instrumentation [1,2]. Integrated studies in which multiple analytical techniques are applied to the same specimen are providing new insight about the nature of IDPs [1]. Such studies are dependent on the ability to prepare specimens that can be analyzed in multiple instruments. Focused ion beam (FIB) microscopy has revolutionized specimen preparation in materials science [3]. Although FIB has successfully been used for a few IDP and meteorite studies [1,4-6], it has yet to be widely utilized in meteoritics. We are using FIB for integrated TEM/NanoSIMS/synchrotron infrared (IR) studies [1].

Graham, G. A.

Perimeter Governed Minority Carrier Lifetimes in 4H-SiC p(+)-n Diodes Measured by Reverse Recovery Switching Transient Analysis

Minority carrier lifetimes in epitaxial 4H-SiC p(+)-n junction diodes were measured via an analysis of reverse recovery switching characteristics. Behavior of reverse recovery storage time (t(s)) as a function of initial ON-state forward current (I(F)) and OFF-state reverse current (I(R)) followed well-documented trends which have been observed for decades in silicon p-n rectifiers. Average minority carrier (hole) lifetimes (tau(p)) calculated from plots of t(s) vs I(R)/I(F) strongly decreased with decreasing device area. Bulk and perimeter components of average hole lifetimes were separated by plotting 1/tau(p) as a function of device perimeter-to- area ratio (P/A). This plot reveals that perimeter recombination is dominant in these devices, whose areas are all less than 1 sq mm. The bulk minority carrier (hole) lifetime extracted from the 1/tau(p) vs P/A plot is approximately 0.7 micro-s, well above the 60 ns to 300 ns average iit'eptimes obtained when perimeter recombination effects are ignored in the analysis. Given the fact that there has been little previous investigation of bipolar diode and transistor performance as a function of perimeter-to-area ratio, this work raises the possibility that perimeter recombination may be partly responsible for poor effective minority carrier lifetimes and limited performance obtained in many previous SiC bipolar junction devices.

Neudeck, Philip G.

Perimeter Governed Minority Carrier Lifetimes in 4H-SiC p+n Diodes Measured by Reverse Recovery Switching Transient Analysis

Minority carrier lifetimes in epitaxial 4H-SiC p-n junction diodes were measured via an analysis of reverse recovery switching characteristics. Behavior of reverse recovery storage time (t(sub s)) as a function of initial ON-state forward current (I(sub f)) and OFF-state reverse current (I(sub R)) followed well-documented trends which have been observed for decades in silicon p-n rectifiers. Average minority carrier (hole) lifetimes (tau(sub p)) calculated from plots of t(sub s) vs I(sub R)/I(sub F) strongly decreased with decreasing device area. Bulk and perimeter components of average hole lifetimes were separated by plotting tau(sub p) as a function of device perimeter-to-area ratio (P/A). This plot reveals that perimeter recombination is dominant in these devices, whose areas are all less than 1 square mm. The bulk minority carrier (hole) lifetime extracted from the 1/Tau(sub p) vs P/A plot is approximately 0.7 microns, well above the 60 ns to 300 ns average lifetimes obtained when perimeter recombination effects are ignored in the analysis. Given the fact that there has been little previous investigation of bipolar diode and transistor performance as a function of perimeter-to-area ratio, this work raises the possibility that perimeter recombination may be partly responsible for poor effective minority carrier lifetimes and limited performance obtained in many previous SiC bipolar junction devices.

Neudeck, Philip G.

Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned Aboard STS-ll1 (UF2) in June 2002

The toxicological assessments of grab sample canisters (GSCs) and 2 solid sorbent air samplers (SSASs) returned aboard STS-111 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSCs were 86-106% and 62% to 136 % from the SSASs; 2 tubes with low surrogate recoveries were not reported. Pressure tracking indicated no leaks in the canisters during analysis. Recoveries from lab and trip controls for formaldehyde analyses ranged from 87 to 96%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Because of the inertness of Freon 218 (octafluoropropane, OFP), Its contribution to the NMVOC is subtracted and tabulated separately. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Because formaldehyde is quantified from sorbent badges, its concentration is listed separately. The table shows that the air quality in general was acceptable for crew respiration; however, certain values shown in bold require further explanation. The 1.05 T value on 2/28/02 was caused by an unusually high measurement ofhexamethylcyc1otrisiloxane (T value = 0.50), which is not a concern. The MPLM T value of 1.42 and the alcohol level of 7.5 mg/cu m were due to an overall polluted atmosphere, which was expected at first entry. The major T-value component was carbon monoxide at a contribution of 0.44 units. Since the crew was only exposed momentarily to the polluted atmosphere, no health effects are expected. The formaldehyde value of 0.060 mg/cu m found in the Lab sample from 3/27/02 is cause for concern because the Lab consistently shows higher concentrations of formaldehyde than the SM and occasionally the concentrations are above the acceptable guideline. Levels of OFP have remained low, suggesting that no further leaks of the SM air conditioner have occurred.

James, John T.

Cost analysis of oxygen recovery systems

Report is made of the cost analysis of four leading oxygen recovery subsystems which include two carbon dioxide reduction subsystems and two water electrolysis subsystems, namely, the solid polymer electrolyte and the circulating KOH electrolyte. The four oxygen recovery systems were quantitatively evaluated. System characteristics, including process flows, performance, and physical characteristics were also analyzed. Additionally, the status of development of each of the systems considered and the required advance technology efforts required to bring conceptual and/or pre-prototype hardware to an operational prototype status were defined. Intimate knowledge of the operations, development status, and capabilities of the systems to meet space mission requirements were found to be essential in establishing the cost estimating relationships for advanced life support systems.

Yakut, M. M.

Recovery Simulator and Analysis Formulation: Mathematical Framework for Enhanced Resilience and Resource Allocation

This report introduces recovery simulator and analysis (RSA), a framework aimed at enhancing the resilience of electrical grids post-disruption. The RSA model leverages an optimization problem formulation that focuses on maximizing the load served (or optionally customers served) through a coordinated and cooptimized recovery of non-black start generation, transmission lines, feeders and substations subject to labor budget constraints. By integrating advanced linear programming techniques, the simulator selects efficient reocovery pathways, optimizing both short-term and long-term grid recovery strategies. The mathematical framework guides decision-making through a comprehensive evaluation of potential recovery actions, factoring in the trade-offs between labor constraints and load (or optionally customer) restoration efficacy. This enables grid operators to simulate diverse outage scenarios and delineate optimal recovery pathways, thereby prioritizing critical repair tasks and ensuring resource allocation is both economical and effective. The intended use case of RSA is to allow planners to explore many recovery scenarios quickly and determine assets most critical across a wide range of scenarios, and therefore strong candidates for hardening or additional investment. RSA might also be used in an operational setting, following a single event, for exploring efficient recovery pathways.

24 POWER TRANSMISSION AND DISTRIBUTION

Briefing Human Reliability Analysis Tasks in the KINS-INL Project

Under the SPP with Korea Institute of Nuclear Safety (KINS) (SPP No. 24SP91), INL research team has a plan to visit KINS on December 3, 2024 and have a project meeting with KINS in-person. INL researchers will give this presentation about what we have done on Task 2 under the contract as below. Task 2: Support KINS in the treatment of human actions. INL efforts consist of: Provide technical expertise on recovery analysis based on INL’s methods or recent research Provide technical expertise on dependency analysis based on INL’s methods or recent research Provide technical expertise on analyzing the effects of HSI degradation on operator actions

99 - GENERAL AND MISCELLANEOUS

Experiment K-6-06. Morphometric and EM analyses of tibial epiphyseal plates from Cosmos 1887 rats

Light and electron microscopy studies were carried out on decalcified tibial epiphyseal plates of rats flown aboard Cosmos 1887 (12.5d flight plus 53.5h recovery). Analysis of variance showed that the proliferative zone of flight animals was significantly higher than that of synchronous controls, while the hypertrophic/calcification zone was significantly reduced. Flight animals had more cells than synchronous controls in the proliferative zone, and less in the hypertrophic/calcification region. The total number of cells, however, was significantly higher in flight animals. No differences were found for perimeter or shape factor of growth plates, but area was significantly lower in flight animals in comparison to synchronous controls. Collagen fibrils in flight animals were shorter and wider than in synchronous controls. The time required for a cell to cycle through the growth plate is 2 to 3 days, so most of the cells and matrix present were formed after the animals had returned to 1 g, and probably represent stages of recovery from microgravity exposure, which in itself is an interesting question.

Duke, P. J.

Stochastic sea state for SRB studies

Ocean surface characteristics at two locations were studied for a space shuttle solid rocket booster ocean impact and recovery analysis. Probability distributions of wave heights, wave slopes, wave velocities, ocean currents, and 1-kilometer altitude winds were formulated. Procedures for generating ocean wave simulations are described.

Perlmutter, M.

Cost analysis of water recovery systems

Cost and performance data from Gemini, Skylab, and other aerospace and biotechnology programs were analyzed to identify major cost elements required to establish cost estimating relationships for advanced life support subsystems for long range planning in support of earth orbital programs. Cost analysis are presented for five leading water reclamation systems; (1) RITE waste management-water system;(2) reverse osmosis system;(3) multifiltration system;(4) vapor compression system; and(5) closed air evaporation system with electrolytic pretreatment.

Yakut, M. M.