Real-time process monitoring for health diagnostics at the thermal interface
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Here, this study presents a novel analytical approach for quantifying Pu(IV) in glove box environments using fiber-optic-based visible–near-infrared absorption spectroscopy in combination with partial least squares regression (PLSR) and design of experiments. The method addresses significant challenges posed by overlapping spectral features arising from Nd(III), which is a common fission product impurity, and the speciation variability of Pu(IV) nitrato complexes in HNO 3 concentrations ranging from 2.5 to 11 M. A curated training set consisting of data from 20 samples was developed via D-optimal design to enable robust PLSR model calibration for Pu(IV) using the near-infrared band near 1050 nm. The training set was acquired from samples in cuvettes with a 1-cm path length and was used to build the PLSR model. The robustness of the model was validated with data collected using a dip probe with a 1-cm path length and varying Pu(IV) concentrations. The strong performance of the model indicates good model transfer from cuvette to dip probe and highlights the potential for in situ measurements and online monitoring of reactions in a crystallization reactor vessel. The results demonstrate that this combined spectroscopic and chemometric approach can accurately and simultaneously quantify Pu(IV) and HNO 3 , thereby offering a promising tool for real-time monitoring in process environments.
Actinium-225 (t1/2 = 9.92 days) is an important radioisotope for targeted alpha therapy applications. The limited supply obtained through the decay of thorium-229 has motivated accelerator-based production routes, including irradiation of thorium targets. Irradiated targets can produce useful quantities of actinium-225, but the product requires final purification from chemically similar lanthanide contaminants. This work describes an automated high-pressure ion chromatography method for this final polishing step. The method uses a reusable strong-acid cation-exchange column bearing sulfonic acid functional groups. α-Hydroxyisobutyric acid (α-HIBA), adjusted to pH 4.3 with lithium hydroxide, complexes and elutes lanthanides, a dilute hydrochloric acid matrix-exchange step removes residual α-HIBA, and concentrated hydrochloric acid then elutes retained actinium(III). The protocol purified actinium-225 to >99% radiopurity across tracer-level samples and samples containing >150 µCi (5.6 MBq) of activity. A 10 min, 0.1 M hydrochloric acid matrix exchange substantially reduced organic eluent carryover, and in-line sodium iodide detection enabled real-time monitoring of actinium and lanthanide elution. The developed method can be completed in <1 h and provides a basis for automated purification workflows for accelerator-produced actinium-225.
This article describes the performance of the pair spectrometer installed in experimental Hall D at Jefferson Lab and its successfully operation in multiple experiments with the GlueX detector. The primary purpose of the pair spectrometer is the precise determination of the flux of beam photons incident on the GlueX target, a critical input for physics analyses such as absolute cross-section measurements. The photon energy spectrum is determined by reconstructing electron–positron pairs produced in a thin converter inserted into the photon beam. The spectrometer is integrated into the GlueX trigger system, whose electronics enable continuous real-time monitoring of the photon flux and the recording of e+e- pair candidates for offline analysis. In addition, the pair spectrometer provides a versatile test facility for evaluating calorimeter prototypes using leptons with well-defined energies produced via electromagnetic pair production.
This report serves as the deliverable for Milestone- M3FT-26AN080502017: Summary of Accomplishments for Online and Offline Analytical Qualification of Chloride Fuel Salts. The qualification of chloride fuel salts is a critical challenge for the development and deployment of molten salt reactors (MSRs), requiring precise control and verification of chemical and isotopic composition to ensure predictable neutronics, manageable radiological behavior, and safe plant operation. Currently, there is no universally accepted standard for fuel salt qualification, particularly for chloride-based systems, which underscores the need for robust, science-based analytical methodologies. This report presents a comprehensive evaluation of both online and offline techniques for quantifying chloride fuel salts, including multielectrode array voltammetry, differential thermal analysis (DTA) probes, inert gas fusion (IGF) analyzers, and gamma spectrometry using the Mirion NAIS-2x2 NaI(Tl) detector. The integration of these methods enables real-time monitoring of actinide concentrations, redox state, and thermophysical properties, as well as high-precision measurement of impurities and isotopic composition. The acquisition of advanced instruments such as the Bruker Leonardo G6 for IGF and the Mirion NaI detector enhances analytical capabilities, supporting the establishment of operational envelopes and impurity thresholds. These approaches provide essential data for neutronic impact evaluation, feedstock documentation, and compliance with nuclear safety standards. The methodologies developed and validated in this report lay the groundwork for future standardized protocols, bridging the gap between laboratory research and commercial reactor operation, and advancing the safe and efficient deployment of chloride-fueled MSRs.
Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.
This study presents a machine learning approach to derive the film formation of biopolymer-templated titania nanostructures during spray deposition, in combination with in situ grazing-incidence small-angle X-ray scattering (GISAXS). A neural network trained on synthetic GISAXS data directly predicts domain-size distributions from experimental two-dimensional scattering patterns, capturing the full kinetics of nanostructure evolution with high temporal resolution. The predictions reveal hierarchical size distributions and periodic growth features, consistent with layer-by-layer spray deposition and validated by complementary scanning electron microscopy (SEM) imaging. Quantitative comparison with conventional parametric GISAXS fits shows good qualitative agreement, with systematic differences explained by domain-shape assumptions and resolved by applying a geometric scaling factor. Simulated SEM-like surfaces derived from neural network outputs reproduce the porous, foam-like nanoscale morphology observed experimentally, reinforcing the method’s credibility. This integrated approach enables real-time, nondestructive, statistically averaged monitoring of bulk nanostructure development in functional coatings, offering a scalable methodology to accelerate the characterization and process control of sustainably manufactured nanostructured titania films for energy-related applications such as photocatalysis and photovoltaics.
This paper presents an innovative Reduced-order model (ROM) for merging experimental and simulation data using data assimilation (DA) to estimate the "True" state of a fluid dynamics system, leading to more accurate predictions. Our methodology introduces a novel approach by implementing the ensemble Kalman filter (EnKF) within a reduced-dimensional framework, grounded in a robust theoretical foundation and applied to fluid dynamics. To address the substantial computational demands of DA, the proposed ROM employs low-resolution (LR) techniques to drastically reduce computational costs. This innovative approach involves downsampling datasets for DA computations, followed by an advanced reconstruction technique based on low-cost singular value decomposition (lcSVD). The lcSVD method, a key innovation in this paper, has never been applied to DA before and offers a highly efficient way to enhance resolution with minimal computational resources. Our results demonstrate significant reductions in both computation time and RAM usage through these LR techniques without compromising the accuracy of the estimations. For instance, in a turbulent test case, for a data compression rate of 15.9, the LR approach can achieve a speed-up of 13.7 and a RAM compression of 90.9% while maintaining a low relative root mean square error (RRMSE) of 2.6%, compared to 0.8% in the high-resolution (HR) reference. Furthermore, we highlight the effectiveness of the EnKF in estimating and predicting the state of fluid flow systems based on limited observations and given low-fidelity numerical data. This paper highlights the potential of the proposed DA method in fluid dynamics applications, particularly for improving computational efficiency in CFD and related fields. Its ability to balance accuracy with low computational and memory costs makes it especially suitable for large-scale and real-time applications, such as environmental monitoring or engineering design. This method will be incorporated into ModelFLOWs-app.
The Fermilab Main Injector (MI) and Recycler Ring (RR) share a common beam loss monitor (BLM) system, making loss events difficult to attribute to their source machine when beam is present in both simultaneously. The Real-time Edge AI for Distributed Systems (READS) project addresses this by deblending BLM readings in real time using machine learning (ML). The current FPGA based implementation meets the sub-3 ms latency requirement but carries a resource intensive hls4ml development cycle, motivating exploration of GPU based deployment. This paper characterizes inference latency on an NVIDIA Jetson Orin Nano and introduces a packet organization scheme for assembling synchronized event frames from seven distributed BLM DAQ streams. Using a Python based DAQ simulation with injected timing jitter in place of unavailable live beam data, the pipeline achieved an average end to end latency of 0.456 ms (σ = 0.122 ms) across 167,000 test frames, comfortably meeting the timing constraint. Early outliers were attributed to TensorRT warm-up rather than steady state limitations, suggesting GPU based inference is a viable alternative to the existing FPGA implementation.
Online reconstruction is key for monitoring purposes and real time analysis in High Energy and Nuclear Physics experiments. A necessary component of reconstruction algorithms is particle identification that combines information left by a particle passing through several detector components to identify the particle’s type. Of particular interest to electro-production Nuclear Physics experiments such as CLAS12 is electron identification which is used to trigger data recording. A machine learning approach was developed for CLAS12 to reconstruct and identify electrons by combining raw signals at the data acquisition level from several detector components. Here, this approach achieves an electron identification purity above 75% whilst retaining an efficiency close to 100%. The machine learning tools are capable of running at high rates exceeding the data acquisition rates and will allow electron reconstruction in real-time. This work enhances online analyses and monitoring and can contribute to improved triggering at CLAS12. This machine learning driven approach will also be crucial for experiments aiming to transition to streaming readout operations where online reconstruction will be a key component of the data taking paradigm.
Low-cost indoor air quality (IAQ) sensors are increasingly being used in homes and commercial and public buildings, driven by growing concerns about the impact of air on health, cognitive performance, and occupant wellbeing. These sensors offer a potentially transformative opportunity to increase spatial and temporal coverage of IAQ monitoring at a fraction of the cost of conventional reference instruments. However, their widespread use raises questions around accuracy, calibration, placement, data handling and interpretation, and integration into existing standards and workflows. This paper presents ten critical questions concerning the use of low-cost IAQ sensors in buildings, drawing on the latest empirical research, field deployments, and emerging practice. It discusses potential frameworks for deployment and evaluation, examines current sensor capabilities for measuring common pollutants, identifies methodological gaps in validation and uncertainty quantification, and outlines the extent to which existing IAQ standards can accommodate sensor-based evidence. The paper also explores how monitoring needs and deployment models vary by building type, the potential of real-time IAQ data to support building operations, and the ethical and legal implications of widespread sensor use. While significant challenges remain in ensuring data quality and building stakeholder trust, new applications are emerging through open data initiatives and advances in analytics and visualization. As the technology, science, and standards co-evolve, low-cost IAQ sensors are poised to become integral to routine building operation, building science, and environmental health research.
A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.
Underwater sound levels near Block Island were monitored during wind turbine construction and operational phases to detect acoustic signals and sediment-borne vibrations, providing real-time data to improve model predictions for future offshore wind facilities.
Autonomous, high-frequency monitoring of outdoor algal ponds is needed to quantify biomass productivity and detect culture decline in environments prone to contamination, grazers, and variable operating conditions. We report successes and lessons learned in translating a laboratory spectroradiometric monitoring approach to a multi-year autonomous field deployment at the Arizona Center for Algae Technology and Innovation (AzCATI). The system measures spectrally resolved pond reflectance by ratioing upwelling radiance from each raceway to simultaneous downwelling sky irradiance using fiber-coupled spectrometers. A physics-based reflectance model (ASHARP) is fit to each spectrum pair to estimate optical parameters, including a biomass-proxy coefficient (C a ) which enables near-real-time tracking of biomass accumulation and culture state at 2–5 min intervals. From May 2022 through September 2025 the platform operated continuously while scaling from two to six raceway ponds. Several strains of algae were monitored successfully, including the high productivity Tetraselmis striata and Picochlorum celeri. Transitioning data acquisition from a Windows laptop to a Raspberry Pi improved uptime from 57% (2022) to ~89% (2024–2025) and enabled routine real-time analysis. Further, we converted relative biomass estimates to absolute ash-free dry weight (AFDW) using experimentally-derived calibrations, providing field-relevant biomass predictions with conservative confidence bounds. These results demonstrate the feasibility of long-term, autonomous optical monitoring for well-mixed open-raceway algal cultivation and provide practical guidance for reliable field operation and scaling.
The accelerator-driven beam uncertainty limits oscillation measurements in long-baseline neutrino experiments. Spill-resolved beam diagnostics and real-time inference are necessary to address these neutrino flux systematics. As such, we present a machine-learning-based beam monitoring framework developed and validated using data from the T2K experiment. Our approach uses downstream, spill-by-spill muon monitor observables to predict upstream parameters such as proton beam position and width. We achieve high predictive accuracy on nominal runs, demonstrating robust baseline performance whether the model is trained on stable runs or systematically varied conditions. The framework is designed to be robust against domain shifts, allowing the neural network architectures and inference strategies developed with T2K data to be retrained and validated using LBNF simulations, with the goal of eventual deployment under real LBNF/DUNE operating conditions. This scalable approach to real-time beam inference offers a pathway toward reducing flux systematics for next-generation neutrino experiments such as DUNE.
A system for decoding an unknown automotive controller area network (“CAN”) message definitions. CAN data vehicle signal mappings are typically held in secret and varied by automotive model and year. Without knowledge of the mappings, the wealth of real-time vehicle data hidden in the automotive CAN packets is uninterpretable—impeding research, after-market tuning, efficiency and performance monitoring, fault diagnosis, and privacy-related technologies. This system can ascertain the CAN signals' boundaries (start bit and length), endianness (byte ordering), signedness (binary-to-integer encoding) from raw CAN data. This allows conversion of CAN data to time series. Interpreting the translated CAN data's physical meaning and finding a linear mapping to standard units (e.g., knowing the signal is speed and scaling values to represent units of miles per hour) can be achieved for many signals by leveraging diagnostic standards to obtain real-time measurements of in-vehicle systems. The system can be integrated into lightweight hardware enabling an OBD-II plugin for real-time in-vehicle CAN decoding or run on standard computers. The system can output a standard DBC file with the signal definition information.
The Fermilab Main Injector (MI) and Recycler Ring (RR) share a common beam loss monitor (BLM) system, making loss events difficult to attribute to their source machine when beam is present in both simultaneously. The Real-time Edge AI for Distributed Systems (READS) project addresses this by deblending BLM readings in real time using machine learning (ML). The current FPGA based implementation meets the sub-3 ms latency requirement but carries a resource intensive hls4ml development cycle, motivating exploration of GPU based deployment. This paper characterizes inference latency on an NVIDIA Jetson Orin Nano and introduces a packet organization scheme for assembling synchronized event frames from seven distributed BLM DAQ streams. Using a Python based DAQ simulation with injected timing jitter in place of unavailable live beam data, the pipeline achieved an average end to end latency of 0.456 ms (σ = 0.122 ms) across 167,000 test frames, comfortably meeting the timing constraint. Early outliers were attributed to TensorRT warm-up rather than steady state limitations, suggesting GPU based inference is a viable alternative to the existing FPGA implementation.
The Integrable Optics Test Accelerator (IOTA) at Fermilab is transitioning from an electron beam facility to a proton beam facility for studies in nonlinear accelerator optics and space-charge dominated proton beams. This project involves the commissioning and fabrication of Ionization Profile Monitors (IPMs) to enable beam profile measurements at IOTA. In general, IPMs work on principle of residual gas ionization by the beam to generate beam profile. This work focuses on a mechanical design that leverages a controlled injection of noble gases, primarily Argon, as the ultra-high vacuum of the IOTA ring provides insufficient residual gas for ionization. Efforts to understand vacuum integration to ensure compatibility with the storage ring environment, the integration of real-time data acquisition systems and the commissioning of the IPMs will be discussed. This project provides a versatile diagnostic tool, supporting IOTA’s role as a testbed for larger-scale accelerator facilities and contributing to the broader understanding of beam physics in high-intensity, high-space-charge regimes.