Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Reactor Dosimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Advancements in PTFE/EPR Reactor Dosimetry

Discussion of current efforts by Radiation Metrology Laboratory at Sandia to continue development and deployment of an EPR/PTFE dosimetry system.

Vehar, David W. [Sandia National Laboratories (SNL

Advanced Test Reactor Neutron Dosimetry Report - Cycle 175C: Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 175C

Results of neutron dosimetry measurements in ATR for cycle 175C are presented. A single set of cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Advanced Test Reactor Neutron Dosimetry Report - 173B (Rev. 1)

Results of neutron dosimetry measurements in ATR for cycle 173B-1&2 are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

173B

NCERC-CL TREAT Free Field Characterization Foil Reaction Rate Results

This report summarizes the analysis and preliminary MCNP reaction rate modeling of free field characterization measurements performed in the Transient Reaction Test Facility (TREAT) at Idaho National Laboratory (INL) between 12/18/2023 and 2/22/2024. A series of seven irradiations were performed using the Big-BUSTER (Broad Use Specimen Transient Experiment Rig) core configuration. Foil sets including 19.5% LEU-Zr alloy wire, S, Au, Fe, Ni, Co, Ti, and Zr were deployed in each irradiation. Identical foil sets were supplied to Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and INL. All foils were supplied by INL. Additional details on the experiment can be found in [2]. The foil sets were shipped to the National Criticality Experiments Research Center Counting Laboratory (NCERC-CL) branch at LANL (NCERC-CL NISC) and were received on 3/25/2024. Additional details on receipt and counting are reported in [3]. All reactor dosimetry measurements were performed in adherence to the ASTM standards applicable to reactor dosimetry. Measured reaction rates from Au, Co, Fe, Ni, and Ti are reported. Select reaction rate ratios and simulated reaction rates and ratios are discussed. Reaction rates for all measured reaction products were modeled with MCNP 6.3.1 and a TREAT input deck supplied by Edward Lum. Neutron emission estimates calculated using the measured and simulated reaction rates show excellent agreement between the three fast-threshold n-p reactions with the percent differences being < 9% between the three reactions. The capture reactions had poorer, but still reasonable, agreement with < 20% percent differences between the neutron emission estimates of the three capture reactions. The percent difference between the fast-threshold and capture reactions is ∼ 100% for each reaction. This supports the TREAT model is not accurately modeling the neutron spectrum and additional measurements are required to characterize TREAT and match measurements to simulation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Advanced Test Reactor Neutron Dosimetry Report - Cycle 175B-1

Results of neutron dosimetry measurements in ATR for cycle 175B-1 are presented. A single set of cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

175B

Advanced Test Reactor Neutron Dosimetry Report - 173B

Results of neutron dosimetry measurements in ATR for cycle 173B-1&2 are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

173B

Advanced Test Reactor Neutron Dosimetry Report

Results of neutron dosimetry measurements in ATR for cycle 173A-1 are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

173A

Advanced Test Reactor Neutron Dosimetry Report - Cycle 175A-1

Results of neutron dosimetry measurements in ATR for cycle 175A-1 are presented. A single set of cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

175A

Advanced Test Reactor Neutron Dosimetry Report – 174 A & B

Results of neutron dosimetry measurements in ATR for cycle 174 A B are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Characterizing secondary neutrons at BLIP for isotope production applications

Fast secondary neutrons created at the Brookhaven Linac Isotope Producer (BLIP) facility following proton irradiation were characterized by the foil activation technique and compared with FLUKA Monte Carlo simulations. The FLUKA-simulated neutron flux was spectrally adjusted following the maximum entropy formalism using the International Reactor Dosimetry and Fusion File (IRDFF-II), with predictions agreeing with experimental measurements to within 9 % following the adjustment procedure. Here, a multitude of degrader configurations were simulated to assess the feasibility of improving the fast (E n > 20 MeV) secondary neutron yield at the proposed neutron target position (“N-slot”). A configuration where the N-slot is closest to the proton degrader produced the highest fast neutron yield, with tungsten degraders achieving the best performance. Assuming the optimized target-degrader configuration proposed in this work, we discuss potential isotope production opportunities with secondary neutrons. In most cases the yields are in the order of several mCi.

07 ISOTOPE AND RADIATION SOURCES

A neutron fluence map of the Los Alamos National Laboratory Godiva IV critical assembly

A neutron fluence map and a total ionizing dose map of the Los Alamos National Laboratory Godiva IV fast burst critical assembly was generated using passive reactor dosimetry, comprised of sulfur pellets and thermoluminescent dosimeters. Godiva IV is an unmoderated, fast burst, critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5 % molybdenum for strength. The mapping was performed during a single 75.6 ºC temperature rise burst operation, with the top and sides of the cylindrical Godiva-IV Top Hat covered in passive dosimetry. Dosimetry was placed in a symmetric pattern around the Top Hat, with higher concentrations near the control rods and burst rod. A specific portion of the lower quadrant of the burst rod was mapped to confirm a testing region where the neutron fluence varied by no more than ± 5%. The results will be used to assess the neutron, gamma, and total ionizing dose environment in three-dimensional space around the assembly for higher fidelity experiment placement, active dosimetry positioning, and radiation field characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Re-evaluating the prompt fission neutron spectrum of spontaneously fissioning 252 Cf

The prompt fission neutron spectrum (PFNS) of spontaneously fissioning 252 Cf is a Neutron Data Standards observable. Nearly all fission spectra of actinides were measured relative to it, using efficiencies derived from it, or analyzed with simulations validated by it. The current Standards evaluation was published by W. Mannhart in 1987. It could not be updated because the evaluation input, experimental mean values and covariances, were lost. First, we attempt to reproduce it. However, Mannhart’s evaluation can only be reproduced within its one-σ uncertainties as some of its aspects (e.g., experimental covariances, rejected data points) remain unknown. Therefore, a new evaluation is presented: We revisit all existing experimental 252 Cf(sf) PFNS data, including those published after the release of the current Standards evaluation, and re-estimate associated covariances. The newly evaluated 252 Cf(sf) PFNS differs distinctly from Mannhart’s below 300 keV and extends it to lower and higher outgoing neutron energies (500 eV–25 MeV). The new evaluated uncertainties are larger from 3–9 MeV and smaller otherwise. Spectrum averaged cross sections of importance to the International Reactor Dosimetry and Fusion File community calculated with the new spectrum are close to those calculated with Mannhart’s evaluation and agree with experimental values well within their uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Lilith: An Enduring Plutonium Critical Assembly [Slides]

A design of an enduring Pu critical assembly has been produced. This is very important to DOE/NNSA missions. This assembly would result in advances/improvements in nuclear data validation, analytical methods validation, dosimetry, reactor kinetics, materials, and more.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Fabrication and Testing of Micro Flux Monitors in the High Flux Isotope Reactor

Neutron dosimetry is a critical technique to measure the neutron flux, fluence, and energy spectrum of nuclear reactors and can be used to indicate fuel reloading, high-power operations, or changes in cycle length. This work presents results of a novel device named the micro flux monitor, which is a miniaturized neutron dosimeter made from small quantities (100s of nanograms) of Ti, Al, Ni, and Au metals deposited on Si and high-purity fused silica substrates using standard semiconductor fabrication techniques. Approximately 1,250 of these devices were produced, and 40 were irradiated in the pneumatic tube facility of the Neutron Activation Analysis Laboratory at the High Flux Isotope Reactor. Testing demonstrated that dosimeter metals can be deposited predictably and repeatedly in multiple geometries, including as quick response (QR) codes. Neutron flux measurements with these devices were within 3% of measurements made using standard flux monitors, demonstrating the efficacy of these devices. Devices were also tested at 500°C under a N2 atmosphere and showed minimal degradation, suggesting they could be deployed for neutron dosimetry measurements in high-temperature advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 172A-1

Results of neutron dosimetry measurements in ATR for cycle 172A-1 are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

172A

Results of Neutron Dosimetry Measurements for the Advanced Test Reactor Cycle 173-C

Results of neutron dosimetry measurements in ATR for cycle 173-C are presented. Cobalt and nickel wires were installed in numerous irradiation locations for the duration of the cycle. The specific activity of these wire segments can be used in conjunction with the presented cycle history information to determine the thermal- and fast-neutron fluence rates for each irradiation position during the cycle using the referenced standard test methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS