Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman thermometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Validation of 266 nm UV Raman thermometry using the alpha-to-beta quartz transition

Ultraviolet Raman scattering is a promising diagnostic for temperature measurements relevant to dynamic compression experiments, where improved signal strength and reduced background are critical. In this work, we experimentally validate Raman thermometry at 266 nm using crystalline quartz heated through the α to β phase transition in a tube furnace. Quartz provides a useful benchmark because of its well-characterized transition temperature near 846 K at ambient pressure. Temperatures inferred from the Stokes to anti-Stokes intensity ratio are compared with thermocouple measurements and with the observed phase transition. Single-shot Raman temperatures track the thermocouple closely, with an empirical single-shot scatter of approximately ±15 K under the present conditions. Temporal averaging reduces shot-to-shot scatter and improves agreement between the Raman temperatures and thermocouple readings to within approximately 8 K, while the transition is identified within 5 K of the accepted value. Measurements are performed using the fourth harmonic of a nanosecond pulsed Nd:YAG laser at 266 nm. The shorter excitation wavelength provides enhanced Raman scattering efficiency and reduced visible background relative to conventional visible excitation. Comparison with 532 nm Raman measurements acquired in the same experimental geometry demonstrates substantially improved signal-to-noise ratio for the UV configuration. These results establish 266 nm Raman thermometry as a reliable and accurate temperature diagnostic under controlled heating conditions and provide a quantitative benchmark for future application in dynamic compression and shock physics experiments.

Chemistry - Chemical explosives↗

Single-Shot Rotational Raman Thermometry for Turbulent Flames Using a Low-Resolution Bandwidth Technique

An alternative optical thermometry technique that utilizes the low-resolution (order 10(exp 1)/cm) pure-rotational spontaneous Raman scattering of air is developed to aid single-shot multiscalar measurements in turbulent combustion studies. Temperature measurements are realized by correlating the measured envelope bandwidth of the pure-rotational manifold of the N2/O2 spectrum with a theoretical prediction of a species-weighted bandwidth. By coupling this thermometry technique with conventional vibrational Raman scattering for species determination, we demonstrate quantitative spatially resolved, single-shot measurements of the temperature and fuel/oxidizer concentrations in a high-pressure turbulent Cf4-air flame. Our technique provides not only an effective means of validating other temperature measurement methods, but also serves as a secondary thermometry technique in cases where the anti-Stokes vibrational N2 Raman signals are too low for a conventional vibrational temperature analysis.

Kojima, Jun↗

Pulse-burst spontaneous Raman thermometry of unsteady wave phenomena in a shock tube

A high-speed temperature diagnostic based on spontaneous Raman scattering (SRS) was demonstrated using a pulse-burst laser. The technique was first benchmarked in near-adiabatic H 2 -air flames at a data-acquisition rate of 5 kHz using an integrated pulse energy of 1.0 J per realization. Both the measurement precision and accuracy in the flame were within 3% of adiabatic predictions. Furthermore, this technique was then evaluated in a challenging free-piston shock tube environment operated at a shock Mach number of 3.5. SRS thermometry resolved the temperature in post-incident and post-reflected shock flows at a repetition rate of 3 kHz and clearly showed cooling associated with driver expansion waves. Collectively, this Letter represents a major advancement for SRS in impulsive facilities, which had previously been limited to steady state regions or single-shot acquisition.

47 OTHER INSTRUMENTATION↗

Ultrafast Raman thermometry in driven YBa 2 C u 3 O 6.48

Signatures of photoinduced superconductivity have been reported in cuprate materials subjected to a coherent phonon drive. A “cold” superfluid was extracted from the transient Terahertz conductivity and was seen to coexist with “hot” uncondensed quasiparticles, a hallmark of a driven-dissipative system of which the interplay between coherent and incoherent responses is not well understood. Here, time resolved spontaneous Raman scattering was used to probe the lattice temperature in the photoinduced superconducting state of YBa 2 ⁢C⁢u 3 ⁢O 6.48 . An increase in lattice temperature of up to 140 K was observed by measuring the time dependent Raman scattering intensity of an undriven “spectator” phonon mode. This value is consistent with the estimated increase in quasiparticle temperature measured under the same excitation conditions. These temperature changes provide quantitative information on the nature of the driven state and its decay, and may suggest a strategy to optimize this effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SILICON CARBIDE THERMOMETRY USING RAMAN SPECTROSCOPY ON IRRADIATED TRISO PARTICLES

Silicon carbide (SiC) passive thermometry has emerged as a promising post-irradiation examination (PIE) technique for estimating irradiation temperature near the end of irradiation. While dilatometry techniques have been traditionally used to analyze prismatic samples after irradiation, Raman spectroscopy has recently been shown to provide comparable results by analyzing Raman-active phonon modes. In this work, Raman spectroscopy has been applied to the SiC layer of cross-sectioned irradiation tristructural isotropic (TRISO) particles from the AGR-5/6/7 experiment to evaluate the feasibility of particle-scale passive thermometry. Two-dimensional Raman mapping was used to measure the position of the SiC longitudinal optical (LO) phonon, which was then converted to an apparent irradiation temperature using a previously established empirical correlation. Particles from AGR-5/6/7 Compacts 2-2-1 and 5-1-3 were selected as their calculated time-averaged, volume-averaged (TAVA) temperatures (828°C and 706°C, respectively) fall within the range of the sensitivity of the experimental approach. The use of SiC thermometry was anticipated to confirm or highlight potential deviations from calculated end-of-life TAVA temperature across compacts. Four particles from Compact 2-2-1 and two particles from Compact 5-1-3 were selected based on 110mAg inventory (either some measurable activity or below the minimum detection limit) which is commonly used as an indicator of in-pile temperature variation of particles within the same compact. Across every particle selected it was determined that the average LO peak position was located around 968 cm-1 to 969 cm-1. Using the previously determined empirical correlation, this corresponds to an irradiation temperature around 950°C to 966°C, which does not align with the reported TAVA temperature values. This discrepancy in apparent irradiation temperatures likely reflects a combination of uncertainties in the calculated particle temperatures and differences in irradiation history between the present specimens and those used to establish the empirical Raman calibration such as neutron flux (damage rate) and SiC microstructure (as fabricated and irradiated).

Vawdrey, Josh [ORNL]↗

SnSe 2 thermal conductivity from optothermal Raman and Stokes/anti-Stokes thermometry

The optothermal Raman method is useful in determining the in-plane thermal conductivity of two-dimensional (2D) materials that are either suspended or supported on a substrate. We compare this method with the Stokes/anti-Stokes scattering thermometry method, which can play a role in both calibration of Raman peak positions as well as extraction of the local phonon temperature. This work demonstrates that the Stokes/anti-Stokes intensity ratio plays an important role in determining the in-plane thermal conductivity of 2D tin diselenide (SnSe 2 ) dry-transferred onto a polished copper (Cu) substrate. The statistically-averaged thermal conductivity of the 108 ± 24 nm-thick SnSe 2 yielded 5.4 ± 3.5 Wm −1 K −1 for the optothermal Raman method, and 2.40 ± 0.81 Wm −1 K −1 for the Stokes/anti-Stokes thermometry method, indicating that the Stokes/anti-Stokes thermometry method to calculate the thermal conductivity of a material can simultaneously increase both precision and accuracy. The uncertainty value was also lowered by a factor of 1.9 from the traditional optothermal Raman method to the Stokes/anti-Stokes thermometry method. The low in-plane thermal conductivity of 2D SnSe 2 , 1.3–2.9 times lower than bulk, is useful for applications in thermal and electrical energy conversion and thermoelectric devices.

2D materials↗

Three-beam rotational coherent anti-Stokes Raman spectroscopy thermometry in scattering environments

Three-beam rotational coherent anti-Stokes Raman scattering (CARS) measurements performed in highly scattering environments are susceptible to contamination by two-beam CARS signals generated by the pump–probe and Stokes–probe interactions at the measurement volume. If this occurs, differences in the Raman excitation bandwidth between the two-beam and three-beam CARS signals can add significant errors to the spectral analysis. This interference to the best of our knowledge has not been acknowledged in previous three-beam rotational CARS experiments, but may introduce measurement errors up to 25% depending on the temperature, amount of scattering, and differences between the two-beam and three-beam Raman excitation bandwidths. Here, the presence of two-beam CARS signal contamination was experimentally verified using a femtosecond–picosecond rotational CARS instrument in two scattering environments: (1) a fireball generated by a laboratory-scale explosion that contained particulate matter, metal fragments, and soot, and (2) a flow of air and small liquid droplets. A polarization scheme is presented to overcome this interference. By rotating the pump and Stokes polarizations +55° and –55° from the probe, respectively, the two-beam and three-beam CARS signals are orthogonally polarized and can be separated using a polarization analyzer. Using this polarization arrangement, the Raman-resonant three-beam CARS signal amplitude is reduced by a factor of 2.3 compared to the case where all polarizations are parallel. This method is successfully demonstrated in both scattering environments. A theoretical model is presented, and the temperature measurement error is studied for different experimental conditions. The criteria for when this interference may be present are discussed.

42 ENGINEERING↗

Device-Level Multidimensional Thermal Dynamics With Implications for Current and Future Wide Bandgap Electronics

Researchers have been extensively studying wide-bandgap (WBG) semiconductor materials such as gallium nitride (GaN) with an aim to accomplish an improvement in size, weight, and power of power electronics beyond current devices based on silicon (Si). However, the increased operating power densities and reduced areal footprints of WBG device technologies result in significant levels of self-heating that can ultimately restrict device operation through performance degradation, reliability issues, and failure. Typically, self-heating in WBG devices is studied using a single measurement technique while operating the device under steady-state direct current measurement conditions. However, for switching applications, this steady-state thermal characterization may lose significance since the high power dissipation occurs during fast transient switching events. Therefore, it can be useful to probe the WBG devices under transient measurement conditions in order to better understand the thermal dynamics of these systems in practical applications. In this work, the transient thermal dynamics of an AlGaN/GaN high electron mobility transistor (HEMT) were studied using thermoreflectance thermal imaging and Raman thermometry. Also, the proper use of iterative pulsed measurement schemes such as thermoreflectance thermal imaging to determine the steady-state operating temperature of devices is discussed. These studies are followed with subsequent transient thermal characterization to accurately probe the self-heating from steady-state down to submicrosecond pulse conditions using both thermoreflectance thermal imaging and Raman thermometry with temporal resolutions down to 15 ns.

42 ENGINEERING↗

Coherent Anti-Stokes Raman Spectroscopic Thermometry in a Supersonic Combustor

An experiment has been conducted to acquire data for the validation of computational fluid dynamics codes used in the design of supersonic combustors. The flow in a supersonic combustor, consisting of a diverging duct with a single downstream-angled wail injector, is studied. Combustor entrance Mach number is 2 and enthalpy nominally corresponds to Mach 7 flight. The primary measurement technique is coherent anti-Stokes Raman spectroscopy, but surface pressures and temperatures have also been acquired. Modern design of experiment techniques have been used to maximize the quality of the data set (for the given level of effort) and to minimize systematic errors. Temperature maps are obtained at several planes in the flow for a case in which the combustor is piloted by injecting fuel upstream of the main injector and one case in which it is not piloted. Boundary conditions and uncertainties are characterized.

Cutler, A. D.↗

Ultrafast Raman probe of the photoinduced superconducting to normal state transition in the cuprate Bi 2 ⁢Sr 2 ⁢CaCu 2 ⁢O 8+𝛿

Here, we report an ultrafast Time-Resolved Raman scattering study of the out-of-equilibrium photoinduced dynamics across the superconducting to normal state phase transition of the cuprate Bi 2 ⁢Sr 2⁢ CaCu 2 ⁢O 8+𝛿 . Using the polarization-resolved momentum space selectivity of Raman scattering, we track the superconducting condensate destruction and recovery dynamics with subpicoseconds time resolution in the antinodal region of the Fermi surface where the superconducting gap is maximum. Leveraging ultrafast Raman thermometry, we find a significant dichotomy between the superconducting condensate and the quasiparticle temperature dynamics near the antinodes, which cannot be framed in terms of a single effective electron temperature. The present work demonstrates the ability of Time-Resolved Raman scattering to selectively probe out-of-equilibrium pathways of different electronic subdegrees of freedom during a photoinduced phase transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Differential multi-probe thermal transport measurements of multi-walled carbon nanotubes grown by chemical vapor deposition

Carbon nanotubes (CNTs) are quasi-one dimensional nanostructures that display both high thermal conductivity for potential thermal management applications and intriguing low-dimensional phonon transport phenomena. In comparison to the advances made in the theoretical calculation of the lattice thermal conductivity of CNTs, thermal transport measurements of CNTs have been limited by either the poor temperature sensitivity of Raman thermometry technique or the presence of contact thermal resistance errors in sensitive two-probe resistance thermometry measurements. Here we report advances in a multi-probe measurement of the intrinsic thermal conductivity of individual multi-walled CNT samples that are transferred from the growth substrate onto the measurement device. The sample-thermometer thermal interface resistance is directly measured by this multi-probe method and used to model the temperature distribution along the contacted sample segment. The detailed temperature profile helps to eliminate the contact thermal resistance error in the obtained thermal conductivity of the suspended sample segment. A differential electro-thermal bridge measurement method is established to enhance the signal-to-noise ratio and reduce the measurement uncertainty by over 40%. The obtained thermal resistances of multiple suspended segments of the same MWCNT samples increase nearly linearly with increasing length, revealing diffusive phonon transport as a result of phonon-defect scattering in these MWCNT samples. The measured thermal conductivity increases with temperature and reaches up to 390 ± 20 W m –1 K –1 at room temperature for a 9-walled MWCNT. In conclusion, theoretical analysis of the measurement results suggests submicron phonon mean free paths due to extrinsic phonon scattering by extended defects such as grain boundaries. The obtained thermal conductivity is decreased by a factor of 3 upon electron beam damage and surface contamination of the CNT sample.

42 ENGINEERING↗

Response of the mode Grüneisen parameters with anisotropic compression: A pressure and temperature dependent Raman study of β-Sn

The lattice dynamic response of body-centered tetragonal beta-Sn (I4 1 /amd) under high-pressure and temperature conditions is determined using experimental optical vibration modes. Here, Raman scattering is used to map the phase stability region of beta-Sn to perform mode Gruneisen analysis, and we demonstrate the necessity of an optical intensity calibration for Raman thermometry. The Gruneisen tensor is evaluated along a set of isotherms to address shortcomings of single-mode Gruneisen parameters with respect to anisotropic deformations of this tetragonal structured soft metal. The changes observed here in the Gruneisen tensor as a function of temperature are related to anharmonicity and denote potential criteria for the onset of premelting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗