Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging

Purpose: To investigate and compare the scatter rejection properties and low-contrast performance of the scan equalization digital radiography (SEDR) technique to the slot-scan and conventional full-field digital radiography techniques for chest imaging. Methods: A prototype SEDR system was designed and constructed with an a-Se flat-panel (FP) detector to improve image quality in heavily attenuating regions of an anthropomorphic chest phantom. Slot-scanning geometry was used to reject scattered radiation without attenuating primary x rays. The readout scheme of the FP was modified to erase accumulated scatter signals prior to image readout. A 24-segment beam width modulator was developed to regulate x-ray exposures regionally and compensate for the low x-ray flux in heavily attenuating regions. To measure the scatter-to-primary ratios (SPRs), a 2 mm thick lead plate with a 2-D array of aperture holes was used to measure the primary signals, which were then subtracted from those obtained without the lead plate to determine scatter components. A 2-D array of aluminum beads (3 mm in diameter) was used as the low-contrast objects to measure the contrast ratios (CRs) and contrast-to-noise ratios (CNRs) for evaluating the low-contrast performance in chest phantom images. A set of two images acquired with the same techniques were subtracted from each other to measure the noise levels. SPRs, CRs, and CNRs of the SEDR images were measured in four anatomical regions of chest phantom images and compared to those of slot-scan images and full-field images acquired with and without antiscatter grid. Results: The percentage reduction of SPR (percentage of SPRs reduced with scatter removal/rejection methods relative to that for nongrid full-field imaging) averaged over four anatomical regions was measured to be 80%, 83%, and 71% for SEDR, slot-scan, and full-field with grid, respectively. The average CR over four regions was found to improve over that for nongrid full-field imaging by 259%, 279%, and 145% for SEDR, slot-scan, and full-field with grid, respectively. The average CNR over four regions was found to improve over that for nongrid full-field imaging by 201% for SEDR as compared to 133% for the slot-scan technique and 14% for the antiscatter grid method. Conclusions: Both SEDR and slot-scan techniques outperformed the antiscatter grid method used in standard full-field radiography. For imaging with the same effective exposure, the SEDR technique offers no advantage over the slot-scan method in terms of SPRs and CRs. However, it improves CNRs significantly, especially in heavily attenuating regions. The improvement of low-contrast performance may help improve the detection of the lung nodules or other abnormalities and may offer SEDR the potential for dose reduction in chest radiography.

60 APPLIED LIFE SCIENCES↗

Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography

Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro-channel plate) to provide gating and high DQE at the 40–200 keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus

Purpose: Given the radiation concerns inherent to the x-ray modalities, accurately estimating the radiation doses that patients receive during different imaging modalities is crucial. This study estimated organ doses, effective doses, and risk indices for the three clinical chest x-ray imaging techniques (chest radiography, tomosynthesis, and CT) using 59 anatomically variable voxelized phantoms and Monte Carlo simulation methods. Methods: A total of 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms were used in this study. Organ doses and effective doses were estimated for a clinical radiography system with the capability of conducting chest radiography and tomosynthesis (Definium 8000, VolumeRAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). A Monte Carlo dose simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain) was used to mimic these two clinical systems. The Duke University (Durham, NC) technique charts were used to determine the clinical techniques for the radiographic modalities. An exponential relationship between CTDI{sub vol} and patient diameter was used to determine the absolute dose values for CT. The simulations of the two clinical systems compute organ and tissue doses, which were then used to calculate effective dose and risk index. The calculation of the two dose metrics used the tissue weighting factors from ICRP Publication 103 and BEIR VII report. Results: The average effective dose of the chest posteroanterior examination was found to be 0.04 mSv, which was 1.3% that of the chest CT examination. The average effective dose of the chest tomosynthesis examination was found to be about ten times that of the chest posteroanterior examination and about 12% that of the chest CT examination. With increasing patient average chest diameter, both the effective dose and risk index for CT increased considerably in an exponential fashion, while these two dose metrics only increased slightly for radiographic modalities and for chest tomosynthesis. Effective and organ doses normalized to mAs all illustrated an exponential decrease with increasing patient size. As a surface organ, breast doses had less correlation with body size than that of lungs or liver. Conclusions: Patient body size has a much greater impact on radiation dose of chest CT examinations than chest radiography and tomosynthesis. The size of a patient should be considered when choosing the best thoracic imaging modality.

61 RADIATION PROTECTION AND DOSIMETRY↗

New detector for use in fast neutron radiography

We have developed and tested a new type detector for use in the fast neutron (FN) imaging radiography applications. FN radiography is generally used for nondestructive material testing, medical and biology applications, border patrol, transportation and cargo screening tasks. It is complementary to other types of radiography, providing additional information on light element content of the material samples. Distinct from other FN imagers presently known, our device implements a neutron-sensitive scintillator attached to a position-sensitive photomultiplier tube (PSPMT), and operates in an event-by-event readout mode, acquiring energy, timing, and pulse shape information for all detected radiation events. The information is used to help separate events of FN interactions in the scintillator from the background events caused by the electronics noise and by the other types of background radiation. Selection of pure fast neutron events in the final image allows us to achieve ultimate image contrast and resolution, as compared with other types of FN imaging devices operating most commonly in an integration mode, in which the detector?s dark noise and radiation background dilute the images. The detector performance for FN imaging application was tested using D-D neutron generator, designed and manufactured by Adelphi Technology, Inc. This essentially point-like neutron source operates in continuous mode producing up to 109 of 2.5 MeV neutrons per second. Samples made of metals plastic and other material were used to measure the detector resolution, efficiency and uniformity. Results of these tests are presented and discussed. Fig. 1 shows one of the test FN radiographic images obtained using the sample made of 11 styrene plastic strips. All strips are squares 4.8 x 4.8 mm2 with six different lengths 10 to 60 mm with 10 mm increment. [A] [B] [C] Fig. 1. [A]-layout of the test sample; [B]-raw FN shadow image of the sample; [C]-map of the plastic strips as they appear on the image, with measured FN absorption factor shown in percent. Both X and Y position resolution of the FN imaging detector are estimated to be less than 0.5 mm (sigma) based on the analysis of the edges of the strip shadows in the plot. Because this detector shows the fraction-of-a-millimeter resolution desirable for most of FN applications, and is built using radiation hard materials, we believe it could be a good alternative to other FN imaging systems based on CCD or solid state detectors. In addition, having a sub-nanosecond timing resolution, it is suitable for the time-of-flight energy-resolved FN imaging.

Popov, V.↗

Microstructure and water absorption of ancient concrete from Pompeii: An integrated synchrotron microtomography and neutron radiography characterization

There is renewed interest in using advanced techniques to characterize ancient Roman concrete due to its exceptional durability and low-carbon footprint. In the present work, samples were drilled from the “Hospitium” in Pompeii and were analyzed by synchrotron microtomography (μCT) and neutron radiography to study how the microstructure, including the presence of induced cracks, affects their water adsorption. The water distribution and absorptivity were quantified by neutron radiography. The 3D crack propagation, pore size distribution and orientation, tortuosity, and connectivity were analyzed from μCT results using advanced imaging methods. Porosity was also measured by mercury intrusion porosimetry (MIP) as a reference. Ductile fracture patterns were observed once cracks were introduced. Compared to Portland cement mortar/concrete, the Pompeii samples had relatively high porosity, low connectivity, and a similar coefficient of capillary penetration. In addition, permeability was predicted from models based on percolation theory and pore structure data to evaluate the fluid transport properties. Understanding the microstructure of ancient Pompeii concrete is important because it could inspire the development of modern concrete with high durability.

36 MATERIALS SCIENCE↗

Flash Kα radiography of laser-driven solid sphere compression for fast ignition

Time-resolved compression of a laser-driven solid deuterated plastic sphere with a cone was measured with flash Kα x-ray radiography. A spherically converging shockwave launched by nanosecond GEKKO XII beams was used for compression while a flash of 4.51 keV Ti Kα x-ray backlighter was produced by a high-intensity, picosecond laser LFEX (Laser for Fast ignition EXperiment) near peak compression for radiography. Areal densities of the compressed core were inferred from two-dimensional backlit x-ray images recorded with a narrow-band spherical crystal imager. The maximum areal density in the experiment was estimated to be 87 ± 26 mg/cm{sup 2}. The temporal evolution of the experimental and simulated areal densities with a 2-D radiation-hydrodynamics code is in good agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Proton Radiography Peers into Metal Solidification

Historically, metals are cut up and polished to see the structure and to infer how processing influences the evolution. We can now peer into a metal during processing without destroying it using proton radiography. Understanding the link between processing and structure is important because structure profoundly affects the properties of engineering materials. Synchrotron x-ray radiography has enabled real-time glimpses into metal solidification. However, x-ray energies favor the examination of small volumes and low density metals. In this study, we use high energy proton radiography for the first time to image a large metal volume (>10,000 mm 3 ) during melting and solidification. We also show complementary x-ray results from a small volume (<1mm 3 ), bridging four orders of magnitude. In conclusion, real-time imaging will enable efficient process development and the control of the structure evolution to make materials with intended properties; it will also permit the development of experimentally informed, predictive structure and process models.

36 MATERIALS SCIENCE↗

Scatter in Cargo Radiography

As a complement to passive detection systems, radiographic inspection of cargo is an increasingly important tool for homeland security because it has the potential to detect highly attenuating objects associated with special nuclear material or surrounding shielding, in addition to screening for items such as drugs or contraband. Radiographic detection of such threat objects relies on high image contrast between regions of different density and atomic number (Z). Threat detection is affected by scatter of the interrogating beamin the cargo, the radiographic system itself, and the surrounding environment, which degrades image contrast. Here, we estimate the extent to which scatter plays a role in radiographic imaging of cargo containers. Stochastic transport simulations were performed to determine the details of the radiography equipment and surrounding environment, which are important in reproducing measured data and to investigate scatter magnitudes for typical cargo. We find that scatter plays a stronger role in cargo radiography than in typicalmedical imaging scenarios, even for low-density cargo, with scatter-toprimary ratios ranging from 0.14 for very low density cargo, to between 0.20 and 0.40 for typical cargo, and higher yet for dense cargo.

99 GENERAL AND MISCELLANEOUS↗

HUGONIOT MEASUREMENTS AT LOW PRESSURES IN TIN USING 800 MeV PROTON RADIOGRAPHY

A 20 mm long 8 mm diameter cylindrical tin target has been shocked to a pressure just below the beta->gamma phase change, using a small, low density PETN charge mounted on the opposite side of a thin stainless steel diaphragm. The density jump and shock velocity were measured radiographically at multiple points as the shock wave moved though the sample and the pressure dropped, using the proton radiography facility at LANL. This provided a quasi-continuous record along the principal Hugoniot from a peak shock velocity of 3.27 km/sec to a minimum of 3.09 km/sec. Edge release effects were removed from the data using simple tomographic reconstruction techniques. The data and analysis are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High order magnetic optics for high dynamic range proton radiography at a kinetic energy of 800 MeV

Flash radiography with 800 MeV kinetic energy protons at Los Alamos National Laboratory is an important experimental tool for investigations of dynamic material behavior driven by high explosives or pulsed power. The extraction of quantitative information about density fields in a dynamic experiment from proton generated images requires a high fidelity model of the proton imaging process. It is shown that accurate calculations of the transmission through the magnetic lens system require terms beyond second order for protons far from the tune energy. The approach used integrates the correlated multiple Coulomb scattering distribution simultaneously over the collimator and the image plane. Comparison with a series of static calibration images demonstrates the model’s accurate reproduction of both the transmission and blur over a wide range of tune energies in an inverse identity lens that consists of four quadrupole electromagnets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assembly and testing of a large zoom lens for proton radiography

A zoom lens has been designed for proton radiography applications. Radiographic images are recorded at the end of an accelerator, where protons exit an aluminum vacuum window, producing a shadowgraph image onto an LYSO (lutetium yttrium orthosilicate) scintillator. Emission from this 5-inch-square scintillator reflects off a pellicle and is then collected by a zoom lens located 24 inches away. Proton radiography can make high-speed, multi-frame radiographs or radiographic movies. This zoom lens provides 2X magnification for viewing different object sizes. The zoom lens incorporates eleven lenses, including a moving doublet that changes the magnification. Refocus of the camera is required when zooming. Only one moving doublet lens is required to change magnification. The stop was anchored to the moving doublet, and its diameter is unchanged throughout magnification changes. The entire lens system is housed in a cylindrical tube. This lens will be used with a 10-frame camera with a 44 × 44 mm square image format and 1100 × 1100 pixel resolution. Suppressing stray light is very important in this lens system. Radial compensation is controlled by two locking micrometers on element 9, which relaxes the mechanical tolerancing. A helical cam barrel using a linear rail controls the movement of the doublet. Alignment of the mechanical gears will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ investigation water distribution in polymer electrolyte fuel cell using neutron radiography

This paper investigates the water content within operating polymer electrolyte membrane (PEM) fuel cells using neutron radiography. We consider fuel cells with various PTFE loadings in their gas diffusion layers (GDL) and microporous layers (MPL), and examine the impacts of MPL/GDL properties on the liquid water behavior and fuel cell performance. Fuel cells are tested at both dry and fully hydrated conditions with different serpentine flow fields. Water contents in the projected areas of channel and land regions are probed. The fuel cell may be subject to more flooding at low current-density operation. Both MPL and GDL wetting properties have substantial impacts on the water content in fuel cell. Cell performance also varies on different scenarios of the MPL/GDL wetting properties. A quad-serpentine channel flow field exhibits higher water content without remarkable change in performance at low current densities. Liquid water profile along the channel is presented and on-set clearly indicated.

30 DIRECT ENERGY CONVERSION↗

Proton radiography of dynamic electric and magnetic fields in laser-produced high-energy-density plasmas

Time-gated, monoenergetic-proton radiography provides unique measurements of the electric (E) and magnetic (B) fields produced in laser-foil interactions and during the implosion of inertial-confinement-fusion capsules. These experiments resulted in the first observations of several new and important features: (1) observations of the generation, decay dynamics, and instabilities of megagauss B fields in laser-driven planar plastic foils, (2) the observation of radial E fields inside an imploding capsule, which are initially directed inward, reverse direction during deceleration, and are likely related to the evolution of the electron pressure gradient, and (3) the observation of many radial filaments with complex electromagnetic field striations in the expanding coronal plasmas surrounding the capsule. The physics behind and implications of such observed fields are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrafast proton radiography of the magnetic fields generated by a laser-driven coil current

Magnetic fields generated by a current flowing through a U-shaped coil connecting two copper foils were measured using ultrafast proton radiography. Two ∼1.25 kJ, 1-ns laser pulses propagated through laser entrance holes in the front foil and were focused to the back foil with an intensity of ∼3 × 10{sup 16 }W/cm{sup 2}. The intense laser-solid interaction induced a high voltage between the copper foils and generated a large current in the connecting coil. The proton data show ∼40–50 T magnetic fields at the center of the coil ∼3–4 ns after laser irradiation. The experiments provide significant insight for future target designs that aim to develop a powerful source of external magnetic fields for various applications in high-energy-density science.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A multi-wavelength, high-contrast contact radiography system for the study of low-density aerogel foams

A multi wavelength, high contrast contact radiography system has been developed to characterize density variations in ultralow density aerogel foams. These foams are used to generate a ramped pressure drive in materials strength experiments at the National Ignition Facility (NIF) and require precision characterization in order to reduce errors in measurements. Here, the system was used to characterize density variations in carbon and silicon based aerogels to ~10.3% accuracy with ~30 μm spatial resolution. The system description, performance and measurement results collected using a 17.8 mg/cc carbon based JX–6 (C 20 H 30 ) aerogel are discussed in this paper.

42 ENGINEERING↗

w22_laser_radiography - Laser-Based MeV Radiography

This project seeks to develop novel x-ray sources based on high-power short-pulse lasers with unique advantages, including small spot size, flexible configuration, and tailorable spectra. Kinetic plasma simulations using the VPIC particle in cell code will be performed to support the R&D goals of this project. If successful, this effort will allow LANL to deploy flexible, compact x-ray sources for static tomographic radiography and dynamic multi-axis radiography at our firing sites and facilities such as pRad and U1a. The higher resolution, shorter pulse duration, and tunability of our proposed sources will enable new applications in the weapons program and broader scientific community. This effort advances the LANL FY22 Strategic Investment Plan priority of “[r]adiographic tools for dynamic and static imaging with improved spatial and temporal resolution, sensitivity, and dose.”

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗