An analysis of carbon 14 radiation detection systems
Carbon 14 radiation detection systems for studying microorganisms in Martian soils
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Carbon 14 radiation detection systems for studying microorganisms in Martian soils
Carbon 14 radiation detection system for life detection experiments
Silicon radiation detecting probe design for in vivo biomedical use
The present invention relates to a graphene field effect transistor-based radiation sensor for use in a variety of radiation detection applications, including manned spaceflight missions. The sensing mechanism of the radiation sensor is based on the high sensitivity of graphene in the local change of electric field that can result from the interaction of ionizing radiation with a gated undoped silicon absorber serving as the supporting substrate in the graphene field effect transistor. The radiation sensor has low power and high sensitivity, a flexible structure, and a wide temperature range, and can be used in a variety of applications, particularly in space missions for human exploration.
An investigation into the multispectral radiation detection of small changes in target emissivity has been performed by Georgia Tech. A series of ice detection measurements on the shuttle external tank (ET) were performed using an advanced instrumentation radiometer operating at 35/95 GHz. Actual shuttle ET ice detection measurements were run at NASA's National Space Technology Laboratory (NSTL) during cryogenic fueling operations prior to orbiter engine firing tests. Investigations revealed that ET icing caused an increase in surface brightness temperature and the test results further demonstrated the usefulness of millimeter wave radiometry for the detection of ice on the ET.
As humans venture to the Moon and beyond, the need for a small, highly sensitive and fast- responding radiation detection device is needed. Research conducted at KSC in collaboration with the University of Central Florida (UCF) and the small business Pegasense investigated the utilization of Passive Surface Acoustic Wave sensors (PSAWs) for radiation monitoring. PSAWs offer advantages over traditional methods of radiation monitoring techniques because of their low cost, compact size, high sensitivity and immediate response times.
Theoretical feasibility of detecting laser radiation scattered from plasma
The authors present a theoretical analysis on the possibility of using the dopant-assisted intrasubband absorption mechanism in quantum wells for normal-incidence far infrared/terahertz radiation detection. The authors describe the proposed concept of the quantum well intrasubband photodetector (QWISP), which is a compact semiconductor heterostructure device compatible with existing GaAs focal-plane array technology, and present theoretical results demonstrating strong normal-incidence absorption and responsivity in the QWISP.
The primary goal of this research project was to further extend the use of advanced heteroepitaxial-semiconductor crystal growth techniques such as molecular beam epitaxy (MBE) and to demonstrate significant gains in UV/blue photonic detection by designing and fabricating atomically-tailored heteroepitaxial GaAlN/GaInN photocathode device structures. This NASA Explorer technology research program has focused on the development of photocathodes for Cherenkov and scintillation radiation detection. Support from the program allowed us to enhance our MBE system to include a nitrogen plasma source and a magnetic bearing turbomolecular pump for delivery and removal of high purity atomic nitrogen during GaAlN/GaInN film growth. Under this program we have also designed, built and incorporated a cesium activation stage. In addition, a connected UHV chamber with photocathode transfer/positioner components as well as a hybrid phototube stage was designed and built to make in-situ quantum efficiency measurements without ever having to remove the photocathodes from UHV conditions. Thus we have constructed a system with the capability to couple atomically-tailored MBE-grown photocathode heterostructures with real high gain readout devices for single photon detection evaluation.
Energetic Particle Explorer satellite probe of particles in Van Allen radiation belt
The Laser Interferometer Space Antenna (LISA) mission is designed for detailed studies of low-frequency gravitational radiation. The mission is currently a candidate for ESA's post-Horizon 2000 program. Thermal noise affects the measurement in at least two ways. Thermal variation of the length of the optical cavity to which the lasers are stabilized introduces phase variations in the interferometer signal, which have to be corrected for by using data from the two arms separately.
The author has identified the following significant results. Multispectral scanner data for Brasilia was corrected for atmospheric interference using the LOWTRAN-3 computer program and the analytical solution of the radiative transfer equation. This improved the contrast between two natural targets and the corrected images of two different dates were more similar than the original ones. Corrected images of MSS data for Ribeirao Preto gave a classification accuracy for sugar cane about 10% higher as compared to the original images.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The prospects of using spacecraft Doppler tracking, in NASA missions, for the detection of gravitational waves are examined. The sensitivity limits of such detection are characterized in terms of plasma scintillation, troposphere scintillation, receiver noise, MDA and ODA quantization error, and clock jitter. Current and possible future NASA missions that will involve gravitational wave experiments are briefly reviewed, including the Galileo, solar polar, Halley/Tempel-2, and solar probe missions.
Explore the source record for details and available documents.
The present invention generally provides a terahertz (THz) imaging system that includes a source for generating radiation (e.g., a quantum cascade laser) having one or more frequencies in a range of about 0.1 THz to about 10 THz, and a two-dimensional detector array comprising a plurality of radiation detecting elements that are capable of detecting radiation in that frequency range. An optical system directs radiation from the source to an object to be imaged. The detector array detects at least a portion of the radiation transmitted through the object (or reflected by the object) so as to form a THz image of that object.
The bypass duct of an aircraft engine is a low-pass filter allowing some spinning modes to radiate outside the duct. The knowledge of the radiated modes can help in noise reduction, as well as the diagnosis of noise generation mechanisms inside the duct. We propose a nonintrusive technique using a circular microphone array outside the engine measuring the complex noise spectrum on an arc of a circle. The array is placed at various axial distances from the inlet or the exhaust of the engine. Using a model of noise radiation from the duct, an overdetermined system of linear equations is constructed for the complex amplitudes of the radial modes for a fixed circumferential mode. This system of linear equations is generally singular, indicating that the problem is illposed. Tikhonov regularization is employed to solve this system of equations for the unknown amplitudes of the radiated modes. An application of our mode detection technique using measured acoustic data from a circular microphone array is presented. We show that this technique can reliably detect radiated modes with the possible exception of modes very close to cut-off.