Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Radiation analysis devices, radiation analysis methods, and articles of manufacture

Radiation analysis devices include circuitry configured to determine respective radiation count data for a plurality of sections of an area of interest and combine the radiation count data of individual of sections to determine whether a selected radioactive material is present in the area of interest. An amount of the radiation count data for an individual section is insufficient to determine whether the selected radioactive material is present in the individual section. An article of manufacture includes media comprising programming configured to cause processing circuitry to perform processing comprising determining one or more correction factors based on a calibration of a radiation analysis device, measuring radiation received by the radiation analysis device using the one or more correction factors, and presenting information relating to an amount of radiation measured by the radiation analysis device having one of a plurality of specified radiation energy levels of a range of interest.

47 OTHER INSTRUMENTATION↗

Variance estimation for radiation analysis and multi-sensor fusion.

Variance estimates that are used in the analysis of radiation measurements must represent all of the measurement and computational uncertainties in order to obtain accurate parameter and uncertainty estimates. This report describes an approach for estimating components of the variance associated with both statistical and computational uncertainties. A multi-sensor fusion method is presented that renders parameter estimates for one-dimensional source models based on input from different types of sensors. Data obtained with multiple types of sensors improve the accuracy of the parameter estimates, and inconsistencies in measurements are also reflected in the uncertainties for the estimated parameter. Specific analysis examples are presented that incorporate a single gross neutron measurement with gamma-ray spectra that contain thousands of channels. The parameter estimation approach is tolerant of computational errors associated with detector response functions and source model approximations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiative properties of quantum emitters in boron nitride from excited state calculations and Bayesian analysis

Abstract Point defects in hexagonal boron nitride (hBN) have attracted growing attention as bright single-photon emitters. However, understanding of their atomic structure and radiative properties remains incomplete. Here we study the excited states and radiative lifetimes of over 20 native defects and carbon or oxygen impurities in hBN using ab initio density functional theory and GW plus Bethe-Salpeter equation calculations, generating a large data set of their emission energy, polarization and lifetime. We find a wide variability across quantum emitters, with exciton energies ranging from 0.3 to 4 eV and radiative lifetimes from ns to ms for different defect structures. Through a Bayesian statistical analysis, we identify various high-likelihood charge-neutral defect emitters, among which the native V N N B defect is predicted to possess emission energy and radiative lifetime in agreement with experiments. Our work advances the microscopic understanding of hBN single-photon emitters and introduces a computational framework to characterize and identify quantum emitters in 2D materials.

Chemistry↗

Thermal radiation analysis of a pressurized oxy-coal combustor with discrete ordinate model

Concerns over climate change have led to numerous efforts in developing low-carbon energy technologies. Pressurized oxy-combustion (POC) is a promising candidate to reduce carbon emissions in power generation. Pressure strongly impacts thermal radiation, leading to a substantial difference in heat transfer between POC and conventional atmospheric pressure combustion. A good understanding of thermal radiation in POC is needed to aid new combustor development. The present work is a step in this direction, initiating a systematic analysis of thermal radiation and heat transfer in a pilot-scale POC combustor, which has been developed at Washington University in St. Louis (WUSTL). In a POC process, pulverized coal is burned under elevated pressure and O2-CO2 environment. Few researchers have investigated the thermal radiation of pressurized oxy-combustion. This work adopted the discrete ordinate model to simulate the radiation of a 1-D cylinder with predetermined conditions (temperature, pressure, gas compositions) to predict the influence of radiative properties of flue gas on the radiation in the combustor.

Li, Lei↗

Using cosmic microwave background radiation analysis tools for flow anisotropies in relativistic heavy-ion collisions

Recently we have shown that there are crucial similarities in the physics of cosmic microwave background radiation (CMBR) anisotropies and the flow anisotropies in relativistic heavy-ion collision experiments (RHICE). We also argued that, following CMBR anisotropy analysis, a plot of root-mean-square values of the flow coefficients, calculated in a laboratory-fixed frame for RHICE, can yield important information about the nature of initial state anisotropies and their evolution. Here we demonstrate the strength of this technique by showing that elliptic flow for noncentral collisions can be directly determined from such a plot without any need for the determination of the event plane.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Algorithms for the reconstruction of the singular wave front of laser radiation: analysis and improvement of accuracy

The possibility of reconstructing a singular wave front of laser beams by the local tilts of the wave front measured with a Hartmann sensor is considered. The accuracy of the reconstruction algorithm described by Fried is estimated and its modification is proposed, which allows one to improve the reliability of the phase reconstruction. Based on the Fried algorithm and its modification, a combined algorithm is constructed whose advantages are demonstrated in numerical experiments. (control of laser radiation parameters)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Synchrotron radiation analysis of possible correlations between metal status in human cementum and periodontal disease

Periodontitis is a serious disease that affects up to 50% of an adult population. It is a chronic condition involving inflammation of the periodontal ligament and associated tissues leading to eventual tooth loss. Some evidence suggests that trace metals, especially zinc and copper, may be involved in the onset and severity of periodontitis. Thus we have used synchrotron X-ray fluorescence imaging on cross sections of diseased and healthy teeth using a microbeam to explore the distribution of trace metals in cementum and adhering plaque. The comparison between diseased and healthy teeth indicates that there are elevated levels of zinc, copper and nickel in diseased teeth as opposed to healthy teeth. This preliminary correlation between elevated levels of trace metals in the cementum and plaque of diseased teeth suggests that metals may play a role in the progress of periodontitis.

60 APPLIED LIFE SCIENCES↗

Radiative Flux Analysis

The Radiative Flux Analysis is a technique for using surface broadband radiation measurements for detecting periods of clear (i.e. cloudless) skies, and using the detected clear-sky data to fit functions which are then used to produce continuous clear-sky estimates. The clear-sky estimates and measurements are then used in various ways to infer cloud macrophysical properties.

54 ENVIRONMENTAL SCIENCES↗

21-ID ESM Beamline Radiation Shielding Analysis

The radiation shielding analysis of Electron Spectro-Microscopy (ESM, 21ID) at 500 mA is documented in this technical note, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR). Figure 1 shows the layout of ESM beam line, which uses 2 undulators (EPU105 or EPU57).

36 MATERIALS SCIENCE↗

21-ID SIX Beamline Radiation Shielding Analysis

The radiation shielding analysis of Soft Inelastic X-ray Scattering(SIX, 2ID) at 500 mA is documented in this technical note, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

11-ID CHX Beamline Radiation Shielding Analysis

The radiation shielding analysis of Coherent Hard X-ray Beamline (CHX, 11 ID) at 500 mA is documented in this technical note, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

23-ID CSX Beamline Radiation Shielding Analysis

The radiation shielding analysis of Coherent Soft X-ray Scattering and Polarization (CSX, 23 ID) beamline at 500 mA is documented in this memo, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

Does Hormone Therapy Reduce Disease Recurrence in Prostate Cancer Patients Receiving Dose-Escalated Radiation Therapy? An Analysis of Radiation Therapy Oncology Group 94-06

Purpose: The purpose of this study was to evaluate the effect on freedom from biochemical failure (bNED) or disease-free survival (DFS) by adding hormone therapy (HT) to dose-escalated radiation therapy (HDRT). Methods and Materials: We used 883 analyzable prostate cancer patients who enrolled on Radiation Therapy Oncology Group (RTOG) 94-06, a Phase I/II dose escalation trial, and whose mean planning target volume dose exceeded 73.8 Gy (mean, 78.5 Gy; maximum, 84.3 Gy). We defined biochemical failure according to the Phoenix definition. Results: A total of 259 men started HT 2 to 3 months before HDRT, but not longer than 6 months, and 66 men with high-risk prostate cancer received HT for a longer duration. At 5 years, the biochemical failure rates after HDRT alone were 12%, 18%, and 29% for low-, intermediate-, and high-risk patients, respectively (p < 0.0001). Cox proportional hazards regression analysis adjusted for covariates revealed that pretreatment PSA level was a significant factor, whereas risk group, Gleason score, T-stage, and age were not. When the patients were stratified by risk groups, the Cox proportion hazards regression model (after adjusting for pretreatment PSA, biopsy Gleason score, and T stage) did not reveal a significant effect on bNED or DFS by adding HT to HDRT Conclusion: The addition of HT did not significantly improve bNED survival or DFS in all prostate cancer patients receiving HDRT, but did approach significance in high-risk patient subgroup. The result of this study is hypothesis generating and requires testing in a prospective randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

17-BM XFP Beamline Radiation Shielding Analysis

The radiation shielding analysis of X-ray Foot printing for In Vitro and In Vivo Structural Studies of Biological Macromolecules (XFP, 17BM) at 500 mA is documented in this technical note, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗