Challenges for Megawatt-Scale Artificial Intelligence Rack Infrastructure

As artificial intelligence (AI) computing densities continue to increase, industry is pursuing megawatt-scale rack architectures that require tightly coordinated advances in electrical power delivery, thermal management, operations, and infrastructure integration. This document summarizes the primary technical challenges for achieving this target.

Nawaz, Kashif [ORNL] (ORCID:0000000251612491)

Polarization-type potential-induced degradation in bifacial PERC modules in the field

This study examines the susceptibility of bifacial glass/glass passivated emitter and rear cell (PERC) modules to potential-induced degradation-polarization (PID-p) in the field. While there are several studies showing PID-p occurring on both front and back faces of bifacial PERC in accelerated tests, we address the yet unclarified behavior in fielded modules. We examine the effects of mounting configuration; specifically, comparing modules mounted near ground and in elevated ground rack configurations. Modules with the cell circuit in -1500 V system voltage configuration, whether mounted on racks about 30 cm above the ground or elevated 2 m high showed mean degradation of 4.5% to 6% in power under standard test conditions over about 2.5 weeks as measured from the front side of the module. This extent of degradation remained sustained for a duration of about 6 months analyzed. Average daytime temperatures of modules in the various mounting configurations were similar and therefore judged to be insufficient to be a primary influence for the modest PID-p rate differences that we observed among mounting configurations. Increased leakage current in the morning suggests morning dew was sustained longer on modules near the ground measured over six months which would be expected to increase the PID-p rate over the long term. However, the main difference seen between the modules on the various mountings during the initial period with up to 6% mean degradation by PID-p was the approximately two times the irradiance from albedo on the rear of modules mounted in elevated ground rack compared to those on the near ground rack. This difference in incident albedo led to a modestly reduced rate of the development of PID-p of the modules on the elevated ground rack. The difference is attributed to the dissipation of PID-p-causing electrical charge by the albedo incident on the module rear. The behavior could be modeled by a sigmoidal equation with consideration of the differences in the insolation on the module rear.

14 SOLAR ENERGY

Maturing Rational Design Methodologies and Industry Consensus Engineering Standards: Critical Fastened Joints - Solar PV Industry

Critical structural joints can be seen throughout a solar array and are called upon to secure modules and keep racking assembled and able to resist large demands from winds and snow loads. In the relatively new and fast-growing solar PV industry, the important role these hardware assemblies (e.g. clips, clamps, bolts, nuts, washers) play is not well understood by product designers. Failures with critical structural joints are surprisingly common and point to the need for maturing the engineering and assembly of these joints. The wide variety of design concepts (Figure 2&2) demonstrate interesting and innovative ideas but are lacking the basics of fastener engineering seen in matured industries (e.g. transportation, buildings). Complicating the maturing process for critical structural joints is that they are one component in rack supporting structures that exhibits a systems behavior; each component will affect the other and play a key role in maintaining structural integrity. When wind loads the surface of a module, the underlying racking members deflect and twist which in turn imparts forces back into the joints and into the mounted modules. Often, these supporting rack structures exhibit high deflections and low natural frequencies which amplify the demands placed into the joints even in moderate winds. Current engineering practices and associated structural conventions view solar racking support structures as they would a high mass building that exhibit more static behaviors in wind events. Solar structures are unique from high mass buildings and require the development of solar specific industry engineering consensus standards.

14 SOLAR ENERGY

Flow dynamics and heat transfer in simplified battery energy storage systems with heated battery modules

Large-scale energy storage systems (ESSs) composed of batteries show promise in addressing current energy challenges, but dissipation of generated heat is important. Here, this paper focuses on buoyant convective flows in simplified ESS battery racks. Natural convection is not generally the primary cooling strategy but can be important in abnormal scenarios where there is module overheat or potentially thermal runaway. We use computational fluid dynamics to investigate the flow dynamics and heat transfer mechanisms in a simplified parameterized rack design. Despite its simplicity, this configuration produces many of the relevant features expected in real ESSs without details of module geometry or hardware, allowing broad conclusions independent of manufacture-specific designs. We start by providing visualizations of the flowfield and measurements of entrainment, heat flux, and pressure. To characterize the dependence on the system parameters, we develop an integral-scale analysis of the average temperature equation to highlight the dominant source terms. We use results from this analysis to derive a steady network model composed of simple algebraic expressions to provide first-order predictions of entrainment through the rack. The network model leads to a linear scaling of the Reynolds number based on convective mass flux with respect to the Grashof number based on the heat source. We deduce empirical relationships that relate the heat exchanged between modules using a surface-averaged Nusselt number as a function of the local Reynolds and Rayleigh numbers. Lastly, we investigate how space between the modules and rack in the spanwise direction creates flow bypass, resulting in different flow pathways.

Battery thermal management

Examination of entrainment, combustibility, and heat transfer due to cell venting inside simplified battery energy storage enclosures

Battery energy storage systems (ESS) assembled of modules containing lithium-ion batteries can pose fire and explosion hazards during thermal runaway because vented gases may accumulate, combust, or escape enclosures. Here, we propose a prototypical configuration composed of the main components of an ESS rack, where modules are represented as rectangles within an enclosure and vent gas is injected steadily through the top of a module. This idealized geometry allows for exploration of how rack-level characteristics can influence smaller single-cell or module-level scales. Through this geometry, we conduct numerical simulations to understand how variations in the vent velocity, temperature, and vertical location affect entrainment rates, fraction of uncombusted fuel, rich-gas coverage, and heat flux to other modules. At lower vent velocities and vertical positions, buoyancy drives enough entrainment and mixing to react with most of the vent gases on the converging plenum. As jet momentum increases and/or buoyancy decreases via higher vent position in the rack, vent gases can propagate into and burn in the divergence plenum. Heat flux to the impinged module scales strongly with vent momentum and temperature, while heat transfer to upper modules peaks when flames in the diverging plenum reach the surface and declines when combustion is suppressed.

Computational fluid dynamics

Idaho National Laboratory’s Mobile Hot Cell Transportation: Engineering Solutions for Global Disused Sealed Radioactive Sources.

Title: Idaho National Laboratory’s Mobile Hot Cell Transportation: Engineering Solutions for Global Disused Sealed Radioactive Sources. Abstract: The Mobile Hot Cell (MHC), currently under development by Idaho National Laboratory (INL) for the Off-Site Source Recovery Project (OSRP), is designed to help international partners meet the unique challenges of end-of-life radioactive material management. The MHC will provide a critical resource for countries that require assistance securing and disposing of Disused Sealed Radioactive Sources (DSRS) and orphaned sources in challenging environments, allowing these sources to be secured against misuse and nefarious activities. The MHC is a rapidly deployable system for conditioning and preparing end-of-life radioactive sources for transportation or storage. It is designed to handle sources of up to 1,000 Ci Co-60 equivalent while maintaining full radiological and biological containment. It will be deployable within 48 hours of an alert, making it ideal for emergency situations. The MHC features an operational suite for control, support racks for electronics, pneumatics, and welding systems, and a modular robust steel structure providing radiological shielding and internal robotic support. This design allows configurations for multiple device types to be conditioned and the ability to safely manage routine issues such as leaking or damaged sources. The MHC has been designed with the transportation challenges of rapid deployment to difficult environments in mind. The system weighs approximately 150,000 pounds, with individual systems breaking down into pieces not exceeding 20,000 pounds. Components are to be transportable on standard 20ft ISO containers, with shielding shells on 20ft flat racks. It is estimated that a total of eight containers and flat racks will be required. The use of 20ft containers, as opposed to 40ft containers, minimizes the impact on less developed road infrastructures, enabling the MHC to be positioned in constrained environments such as hospital parking lots. The system’s modularity also allows for deployment using smaller equipment, such as a 10-ton boom truck or forklift, which is crucial given the potential logistical challenges in different countries. This transportation strategy, evaluated in collaboration with Utah State University, ensures the MHC can be deployed via ground, rail, sea, or air, addressing the primary concern of international transport logistics.

99 - GENERAL AND MISCELLANEOUS

Fermilab PIP-II CDS & CM Cryogenic Controls System

Details on Final design for Cryogenic Electrical & Controls System for Fermilab' s next-gen particle accelerator PIP-II. Electrical Controls System includes instrumentation and controls of Cryogenics Distribution System and Cryomodules. Design includes Siemens PCS7 Controls System with 26 Remote IO Rittal Cabinets and 48 Relay Racks for Temperature Readouts, Valve Positioners, Level, Heater Controls etc. Electrical Drawings and Design have been completed with focus now on fabrication of the 26 Rittal Cabinets and 48 Relay Racks. All materials have been procured. EPICS will be used as a SCADA system communicating to S7 Controllers via OPC UA.

Patel, Pratik [Fermilab]

Fermilab PIP-II CDS and CM Cryogenic Controls System

Details on Final design for Cryogenic Electrical & Controls System for Fermilab' s next-gen particle accelerator PIP-II. Electrical Controls System includes instrumentation and controls of Cryogenics Distribution System and Cryomodules. Design includes Siemens PCS7 Controls System with 26 Remote IO Rittal Cabinets and 48 Relay Racks for Temperature Readouts, Valve Positioners, Level, Heater Controls etc. Electrical Drawings and Design have been completed with focus now on fabrication of the 26 Rittal Cabinets and 48 Relay Racks. All materials have been procured. EPICS will be used as a SCADA system communicating to S7 Controllers via OPC UA.

Patel, Pratik [Fermilab]

Futureproofing through 2035 for the AI and HPC Power Density Trend

HPC and AI are businesses necessitating growth for providing performance improvement with increased power and cooling. As HPC and AI computers and their supporting facilities approach utility scale with a frequency of technology innovation outpacing utility and construction timelines, understanding and designing for this trend has become critical. This paper will provide historical trend data for facilities and compute racks, relate power trend data to cooling technology capabilities, and reason through constraints impacting anticipated future power densities to aid the reader in futureproofing a facility’s power and cooling systems through the mid-2030’s.

97 MATHEMATICS AND COMPUTING

Berkeley eXtensible Environment (BXE) v3

The Berkeley eXtensible Environment (BXE) provides a cloud environment for hardware designers and computer architects to design, build, and simulate their custom architectures on an on-premises FPGA cluster. Utilizing the Chipyard, MoSAIC, and FireSim frameworks, users are provided an environment where they can assemble SoC designs from an existing library of components or import their own source code. Once their designs are ready, they can utilize the FireSim framework provided by BXE to deploy and simulate their designs on the FPGA. Users aren't limited to a single FPGA; they can deploy multiple instances across multiple FPGAs, acting like a rack of servers, or partition their large design across multiple FPGAs, ganging multiple FPGAs into a single simulated system.

Fatollahi-Fard, Farzin

Summer Aerosol and Trace Gas Observations in Houston, Texas Using an Adaptable Mobile Facility

An aerosol container featuring a shared inlet system was deployed to Houston, Texas in July 2022, enabling direct, high-time-resolution in situ measurements of aerosols and trace gases. The internal rack system and floorplan was designed for adaptable modularity to elucidate aerosol physicochemical processes at fine scales. The design allowed for the deployment of a core instrument suite and additional customized research grade instruments. A heterogeneous mixture of aerosols was observed during three regimes: (1) intermittent black carbon (BC) and diurnal variations in aerosol chemical composition, (2) observed particle growth associated with SO 2 , (3) transported supermicron dust. The high variability of observed particles and gases in high time resolution indicated a complex urban area with multiple local and regional sources and processes. Particle growth rates of 7–16 nm/hr were observed for submicron particles during periods when SO 2 was >0.5 ppbv. Two periods of multi-day long-range transport events of dust from the African Sahara were observed in the supermicron and submicron particle modes with total mass concentrations up to 30 μg m −3 . Aerosol scattering angstrom exponents and extinction coefficients (B ext ) increased with humidity as a function of particle composition. The measurements demonstrate collaborative capabilities that can be used to increase observations of aerosol processing, microphysical and optical properties, internal mixing state, and supermicron aerosol that are not parameterized or missing in global Earth energy system models.

54 ENVIRONMENTAL SCIENCES

Analog Signal Multiplexing System for the Iota Proton Injector

The Fermilab Accelerator Science and Technology (FAST) Facility at FNAL is a dedicated research and development center focused on advancing particle accelerator technologies for future applications worldwide. Currently, a key objective of FAST Operations is to commission the 2.5 MeV IOTA Proton Injector (IPI) and enable proton injection into the Integrable Optics Test Accelerator (IOTA) storage ring. The low and medium-energy sections of the IPI include four frame-style dipole trims and two multi-function correctors with independently controlled coils, requiring readout of 32 analog channels for current and voltage monitoring in total. To reduce cost and optimize rack space within the PLC-based control system, a 32-to-4 analog signal multiplexing system was designed and implemented. This system enables real-time readback of excitation parameters from all magnetic correctors. This paper presents the design, construction, implementation, and performance of the multiplexing system.

MacLean, Daniel R. [Fermilab] (ORCID:0000000210103

Coastal Cloud Chemistry during EPCAPE Field Campaign Report

For this campaign, Principal Investigator Markus Petters deployed a suite of instruments inside Lynn Russell’s container that was sited at Mt. Soledad during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) campaign. Funding for this activity was provided by National Science Foundation Award 2410536. The instrument rack (Figure 1) included a differential mobility analyzer, a condensation particle counter, a portable optical particle spectrometer, and a continuous flow diffusion cloud condensation nuclei counter (CCN). The instruments sampled from a counterflow virtual impactor (CVI) inlet and an isokinetic inlet. The measurements provided aerosol size distribution, size-resolved CCN activity, and denuded versus undenuded CCN activity of aerosols and cloud drop residuals.

54 ENVIRONMENTAL SCIENCES

Artificial Intelligence for Data Center Operations (AIOps): Cooperative Research and Development (Final Report)

High performance computing data centers will increasingly need to rely on automation to keep pace with exascale growth in compute capability and to manage and optimize the data center environment and facility resources. Artificial intelligence and machine learning approaches provide the means to improve HPC data center operational efficiency, by learning historical trends and training models to operate on real-time data collected from both IT and facilities sources. NREL has developed methods of real-time collection, aggregation and streaming of these data in the ESIF HPC Data Center and has collected a significant dataset of relevant metrics across computer systems, racks, environmental, building and utility sources for research into various predictive analytics problems. HPE's Advanced Technology Group (ATG) is doing comprehensive research into exascale monitoring and management for High Performance Computing (HPC) systems (hereinafter HPE's Data Monitoring/ Management Technology). NREL and HPE will collaborate to add Artificial Intelligence (AI) to NREL's real-time data collection/ aggregation/ streaming system and HPE's Data Monitoring/ Management System, with the goal of improving the operational efficiency of NREL's Energy Systems Integration Facility (ESIF) HPC Data Center through data analytics on both historical and real-time data from IT systems and facilities operations. This collaboration will consist of efforts in Data Management, Data Analytics, and AI/ML Optimization for both manual and autonomous intervention in data center operations. This will be a multi-year, multi-staged effort with a goal towards building capabilities for an Advanced Smart Facility, and demonstration of these techniques in the NREL ESIF HPC Data Center.

97 MATHEMATICS AND COMPUTING

Analog Signal Multiplexing System for the IOTA Proton Injector

he Fermilab Accelerator Science and Technology (FAST) Facility at FNAL is a dedicated research and development center focused on advancing particle accelerator technologies for future applications worldwide. Currently, a key objective of FAST Opera-tions is to commission the 2.5 MeV IOTA Proton Injec-tor (IPI) and enable proton injection into the Integrable Optics Test Accelerator (IOTA) storage ring. The low and medium-energy sections of the IPI include four frame-style dipole trims and two multi-function cor-rectors with independently controlled coils, requiring readout of 32 analog channels for current and voltage monitoring in total. To reduce cost and optimize rack space within the PLC-based control system, a 32-to-4 analog signal multiplexing system was designed and implemented. This system enables real-time readback of excitation parameters from all magnetic correctors. This paper presents the design, construction, implementation, and performance of the multiplexing system.

MacLean, Daniel R. [Fermilab] (ORCID:0000000210103

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY

Conceptual Design of a Water Tank Critical Facility for SPARC

Critical experiments, sometimes referred to zero-power reactors, are crucial tools in developing and validating nuclear physics predictions and thus an indispensable capability to ensure criticality safety during all parts of the nuclear fuel cycle and in reducing uncertainties in reactor physics predictions toward optimizing nuclear energy production. The System Physics Advanced Reactor Facility (SPARC) project was recently initiated to enable large-scale criticality experiments using a horizontal split table machine well suited toward solid core materials systems (fuel, moderator, reflector). The facility selected for this mission was a former pool-type research reactor building and thus also well suited toward a second critical experiment capability able to house full-size light-water reactor (LWR) fuel bundles. A conceptual design study was undertaken to review past water tank critical experiments used for LWR physics experiments and to develop an early engineering design for a new critical assembly tank (CAT). The work described here shows that a relatively simple CAT concept can be constructed and deployed in the SPARC facility to meet the urgent demands for new critical experiments on advanced LWR fuel bundles designs. The SPARC facility layout is conducive to the receipt and upending of LWR fuel bundles using existing containers and equipment from the LWR industry. The facility’s overhead crane can then be used to handle fuel bundles and place them in a vertical storage rack or in the CAT for critical experiments, both of which fit within the building’s “open basement” alongside other equipment planned for SPARC and the horizontal split table. A slightly lower area in the basement can serve as a large drain tank so that fail-safe valves drain the CAT reactor tank for safe shutdown. Neutronic configurations were determined where a 3 × 3 array of fuel bundles can be surrounded by full-length “loose rods” to adjust reactivity so that critical is achieved when the bundles are fully submerged. Viable configurations were determined for both pressurized- and boiling-water-reactor-type fuel bundles. This design concept was used to develop an early planning basis for establishing the CAT capability alongside the otherwise planned SPARC project in order to help streamline the process. Recent presidential executive orders have highlighted the need to achieve power uprates in LWR plants and the CAT capability will be a crucial element of these initiatives. Based on the work described herein, it is recommended that an earnest and timely project begin in order to establish this urgently needed capability.