Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RUBIDIUM 86”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Beta decay of rb86

Measuring of rubidium 86 beta decay using lithium drifted surface barrier silicon detectors

BETA RADIATION↗

Nuclear Data Sheets for A = 86

The experimental nuclear spectroscopic data for known nuclides of mass number 86 (Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo, Tc) have been evaluated and presented together with Adopted properties for levels and γ rays. New high-spin data are available for {sup 86}Se, {sup 86}Br, {sup 86}Kr, {sup 86}Sr, {sup 86}Y, {sup 86}Zr and {sup 86}Mo; and lifetime data for high-spin states in {sup 86}Y and {sup 86}Zr. No significant new data since the 2001 NDS for A=86 have been reported for {sup 86}Rb and {sup 86}Nb. No data are yet available for excited states in {sup 86}Ga and {sup 86}As. The decay scheme of radioactive {sup 86}Ge is unknown, while those for {sup 86}Ga, {sup 86}As, 47.4 min isomer of {sup 86}Y, {sup 86}Nb and {sup 86}Tc are deemed as incomplete. Isomerism in {sup 86}Nb remains unconfirmed. This work supersedes the data presented in the previous NDS evaluation of A=86 published by 2001Si43.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NitroJet{sup R}'s Verification Test of Contaminated Water Storage Tank Decontamination in Fukushima Daiichi Nuclear Power Plant - 16489

After the Fukushima Daiichi nuclear disaster, much radioactively contaminated water has generated and has been stored into tanks in the site. Therefore, these contaminated water storage tanks (flange-type) are severely required to be decontaminated in order to be dismantled or to be reused to store cleaner water with less radioactive liquid waste and exposure of workers. Then, IHI Corporation (hereinafter, IHI) have verified that NitroJet{sup R} had capability to decontaminate these tanks under governmental grant (the Validation of technologies for contaminated water management project in the FY2013 Supplementary Budget). For this verification, IHI achieved acquiring DF (decontamination factor) by fabricating radioactive partial mock-ups with Rb-86. Moreover, IHI have demonstrated remote operation of decontamination work by using tank's partially full-scale mock up. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pediatric radiation dosimetry for positron-emitting radionuclides using anthropomorphic phantoms

Purpose: Positron emission tomography (PET) plays an important role in the diagnosis, staging, treatment, and surveillance of clinically localized diseases. Combined PET/CT imaging exhibits significantly higher sensitivity, specificity, and accuracy than conventional imaging when it comes to detecting malignant tumors in children. However, the radiation dose from positron-emitting radionuclide to the pediatric population is a matter of concern since children are at a particularly high risk when exposed to ionizing radiation.Methods: The authors evaluate the absorbed fractions and specific absorbed fractions (SAFs) of monoenergy photons/electrons as well as S-values of 9 positron-emitting radionuclides (C-11, N-13, O-15, F-18, Cu-64, Ga-68, Rb-82, Y-86, and I-124) in 48 source regions for 10 anthropomorphic pediatric hybrid models, including the reference newborn, 1-, 5-, 10-, and 15-yr-old male and female models, using the Monte Carlo N-Particle eXtended general purpose Monte Carlo transport code.Results: The self-absorbed SAFs and S-values for most organs were inversely related to the age and body weight, whereas the cross-dose terms presented less correlation with body weight. For most source/target organ pairs, Rb-82 and Y-86 produce the highest self-absorbed and cross-absorbed S-values, respectively, while Cu-64 produces the lowest S-values because of the low-energy and high-frequency of electron emissions. Most of the total self-absorbed S-values are contributed from nonpenetrating particles (electrons and positrons), which have a linear relationship with body weight. The dependence of self-absorbed S-values of the two annihilation photons varies to the reciprocal of 0.76 power of the mass, whereas the self-absorbed S-values of positrons vary according to the reciprocal mass.Conclusions: The produced S-values for common positron-emitting radionuclides can be exploited for the assessment of radiation dose delivered to the pediatric population from various PET radiotracers used in clinical and research settings. The mass scaling method for positron-emitters can be used to derive patient-specific S-values from data of reference phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Stellar (n, {gamma}) cross sections for Br and Rb: Matching the weak and main s-process components

The stellar (n, {gamma}) cross sections of {sup 79}Br, {sup 81}Br, {sup 85}Rb, and {sup 87}Rb have been determined by a series of ten activation measurements in a quasistellar neutron spectrum corresponding to a thermal energy of kT = 25 keV. The final uncertainties between 3 and 10% were dominated by the {gamma}-ray intensities in the decay of the respective reaction products. All other uncertainties were significantly reduced through variation of the experimental parameters. The consequences of these results for s-process nucleosynthesis of Br and Rb, and in particular of the local s-only isotopes {sup 80,} {sup 82}Kr and {sup 86,} {sup 87}Sr, are discussed with respect to the branching points at {sup 79}Se and {sup 85}Kr. The contributions of both the main s component from thermally pulsing low mass asymptotic giant branch stars and the weak s component from massive stars are considered in this analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of respiratory motion on internal radiation dosimetry

Purpose: Estimation of the radiation dose to internal organs is essential for the assessment of radiation risks and benefits to patients undergoing diagnostic and therapeutic nuclear medicine procedures including PET. Respiratory motion induces notable internal organ displacement, which influences the absorbed dose for external exposure to radiation. However, to their knowledge, the effect of respiratory motion on internal radiation dosimetry has never been reported before. Methods: Thirteen computational models representing the adult male at different respiratory phases corresponding to the normal respiratory cycle were generated from the 4D dynamic XCAT phantom. Monte Carlo calculations were performed using the MCNP transport code to estimate the specific absorbed fractions (SAFs) of monoenergetic photons/electrons, the S-values of common positron-emitting radionuclides (C-11, N-13, O-15, F-18, Cu-64, Ga-68, Rb-82, Y-86, and I-124), and the absorbed dose of {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) in 28 target regions for both the static (average of dynamic frames) and dynamic phantoms. Results: The self-absorbed dose for most organs/tissues is only slightly influenced by respiratory motion. However, for the lung, the self-absorbed SAF is about 11.5% higher at the peak exhale phase than the peak inhale phase for photon energies above 50 keV. The cross-absorbed dose is obviously affected by respiratory motion for many combinations of source-target pairs. The cross-absorbed S-values for the heart contents irradiating the lung are about 7.5% higher in the peak exhale phase than the peak inhale phase for different positron-emitting radionuclides. For {sup 18}F-FDG, organ absorbed doses are less influenced by respiratory motion. Conclusions: Respiration-induced volume variations of the lungs and the repositioning of internal organs affect the self-absorbed dose of the lungs and cross-absorbed dose between organs in internal radiation dosimetry. The dynamic anatomical model provides more accurate internal radiation dosimetry estimates for the lungs and abdominal organs based on realistic modeling of respiratory motion. This work also contributes to a better understanding of model-induced uncertainties in internal radiation dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cross sections and calculated yields of some radionuclides of yttrium, strontium and rubidium formed in proton-induced reactions on enriched strontium-86: possibility of production of 85g Sr, 83 Rb and 82m Rb in no-carrier-added form

Here, cross sections of the 86 Sr(p,3n) 84m Y, 86 Sr(p,αn) 82m Rb, and 86 Sr(p,x) 85g Sr reactions were measured from their respective thresholds up to 16.2 MeV and from 23.0 to 44.1 MeV at FZJ, and from 14.3 to 24.5 MeV at LBNL, using 96.4% enriched 86 SrCO 3 as target material. Thin targets prepared by sedimentation were irradiated with protons in a stacked-form, and the induced radioactivity was measured by high-resolution γ-ray spectrometry. Nuclear model calculations based on the code TALYS reproduced our experimental cross section data well. From the excitation functions, the integral yields of the above three radionuclides were calculated. The yield of 85g Sr via the natSr(n,γ) process was also measured using the TRIGA Mark-II reactor at AERE, Savar. A comparison of the reactor and cyclotron production of carrier-added 85g Sr is given. The production possibilities of the three investigated radionuclides in no-carrier-added forms at a 30 MeV cyclotron via new routes are discussed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Electron {sup 83}Rb/{sup 83m}Kr Source for the Energy Scale Monitoring in the KATRIN Experiment

The KATRIN (KArlsruhe TRItium Neutrino) experiment investigates the endpoint region of the tritium {beta}-spectrum aiming for the sensitivity on the neutrino mass of 0.2 eV (90% C.L.). A spectrometer of the MAC-E filter (Magnetic Adiabatic Collimation with an Electrostatic filter) type will be used for a total time of at least 5 years. An unrecognized shift of the filtering potential would directly influence the resulting neutrino mass. To continuously monitor the filtering potential the high voltage (HV) will be simultaneously applied to an additional MAC-E filter spectrometer. In this monitor spectrometer suitable electron sources based on atomic/nuclear standards will be utilized. As one of such monitoring tools the solid {sup 83}Rb/{sup 83m}Kr source is intended. It provides conversion electrons from {sup 83m}Kr(t{sub 1/2} = 1.83 h) which is continuously generated by {sup 83}Rb(t{sub 1/2}{approx_equal}86 d). The Calibration and Monitoring task of the KATRIN project demands the long-term energy stability {Delta}E/E of the K-32 conversion electron line (E = 17.8 keV, {Gamma} = 2.7 eV) of {+-}1.6 ppm/month.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗