Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RPL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

PC-RPL: Joint Control of Routing Topology and Transmission Power in Real Low-Power and Lossy Networks

We present PC-RPL , a transmission power-controlled IPv6 routing protocol for low-power and lossy wireless networks that significantly improves the end-to-end packet delivery performance under heavy traffic compared to the standard RPL. We show through actual design, implementation, and experiments that a multihop wireless network can achieve better throughput and routing stability when transmission power and routing topology are “jointly and adaptively” controlled. Our experiments show that the predominant “fixed and uniform” transmission power strategy with “link quality and hop distance”–based routing topology construction (i.e., RPL) loses significant bandwidth due to hidden terminal and load imbalance problems. We design an adaptive and distributed control mechanism for transmission power and routing topology, named PC-RPL , on top of the standard RPL routing protocol for hidden terminal mitigation and load balancing. We implement PC-RPL on real embedded devices and evaluate its performance on a 49-node multihop testbed. PC-RPL reduces total end-to-end packet losses by approximately sevenfold without increasing hop distance compared to RPL with the highest transmission power, resulting in 17% improvement in aggregate bandwidth and 64% improvement for the worst-case node by successfully alleviating both hidden terminal and load imbalance problems.

Computer Science↗

Comparison of the performance of TLD, OSL and RPL personal dosimetry systems to the American National Standard Institute (ANSI) test categories

The Laboratory Accreditation Program (LAP) tests the capability and performance of the United States Department of Energy's (USDOE) facilities to accurately measure and quantify the whole-body and extremity radiation equivalent doses to the occupational workers. The dosimetry methods used in personal dosimetry can be Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radiophotoluminescence (RPL), among other techniques available. Currently, the TL (LiF:Mg,Ti) and OSL (Al 2 O 3 :C) dosimetry systems are DOELAP-accredited for occupational dose measurements and regulatory reporting. In this study, the performance of a beryllium oxide (BeO) OSL dosimetry system and of a silver-doped phosphate glass RPL dosimetry system is compared against the performance of an accredited LiF:Mg,Ti TL dosimetry system. The bias and standard deviation in each of the performance test categories are compared between these three systems for exposures to photons, beta, and mixed radiation fields with the criteria established by the American National Standard Institute (ANSI) and Health Physics Society (HPS) N13.11-2022 standard. The practical implementation of the dosimetry program and its equivalency to the occupational personal equivalent dose H p (0.07) and H p (10) measurements were evaluated. The TL, OSL and RPL dosimetry systems passed the ANSI performance test criteria for H p (0.07) and H p (10) occupational dose measurements and met the DOELAP accreditation requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis and Recommendation of Alpha-Beta Continuous Air Monitor Alarm Setpoints for the RPL Stack Exhaust

The Radiochemical Processing Laboratory (RPL) alpha-beta continuous air monitor (CAM) is used for real-time detection of “artificial” alpha-beta particulates from the stack exhaust. The CAM interfaces with software developed by the Pacific Northwest National Laboratory—called the “PNNL OS3300 Alpha-Beta Monitoring Software”—that provides real-time estimates of alpha-beta air concentrations and integrated activities that are calculated from measured CAM counts. The OS3300 software has alarm setpoints that can be used to provide an early indication of larger releases, that if allowed to persist, could approach defined dose limits. This report performs a detailed review of historical and current alarm setpoints used at RPL, including discussion of the technical basis used in their development, analysis of alarm frequencies using measured historical data, and performs a detailed dose assessment using more realistic release scenarios, meteorology, and adjustment factors used in estimating released stack activity. Based on the results, the alpha and beta air concentration alarm setpoints will remain 1.77 × 10 -8 µCi/ml and 3.47 × 10 -8 µCi/ml, respectively; and the alpha and beta integrated activity alarm setpoints will remain 70.22 µCi and 137.63 µCi, respectively. These setpoints achieve the right operational balance in identifying larger releases from planned radiological work at RPL, without being overly conservative so as to cause nuisance alarming. Furthermore, implied doses associated with these setpoints are below defined and regulatory limits.

325RPL↗

Analysis and Recommendation of Tritium Gas Continuous Air Monitor Alarm Setpoints for the RPL Stack Exhaust

The Radiochemical Processing Laboratory (RPL) tritium continuous air monitor (CAM) is used for near real-time detection of tritium gas (i.e., elemental tritium [HT] and tritiated water vapor [HTO]) in the stack exhaust. The CAM interfaces with software developed by the Pacific Northwest National Laboratory (PNNL)—called the “PNNL OS3700 Tritium Monitoring Software”—that provides near real-time estimates of tritium gas air concentrations and integrated daily activities that are calculated from measured CAM counts. The OS3700 software implements alarm setpoints to alert the facility of larger tritium gas releases that if allowed to persist, could begin to challenge permitted emission and established dose constraints. This report performs a detailed review of historical and current tritium alarm setpoints used at RPL, including discussion of the technical basis used in their development, analysis of alarm frequencies using measured historical data, and performs a detailed dose assessment using more realistic release scenarios and meteorology. Based on the results, the tritium air concentration and integrated daily tritium activity alarm setpoints will remain 2.0 × 10 -5 µCi/ml and 25 Ci/day, respectively. These setpoints achieve the right operational balance in identifying larger releases from planned tritium work at RPL, without being overly conservative so as to cause nuisance alarming. Furthermore, implied doses associated with these setpoints are well below defined and regulatory limits.

325RPL↗

Radiochemical Processing Laboratory (RPL) at PNNL

Nuclear research is one of the core components of PNNL's mission. The centerpiece of PNNL's nuclear research is the Radiochemical Processing Laboratory (RPL), a Category 2 nuclear facility with state-of-the-art instrumentation, scientific expertise, and specialized capabilities that enable research with significant quantities of fissionable materials and other radionuclides—from tritium to plutonium. High impact radiological research has been conducted in the RPL since the 1950's, when nuclear weapons and energy production at Hanford were at the forefront of national defense. Since then, significant investments have been made in the RPL to maintain it as a premier nuclear science research facility supporting multiple programs. Most recently, PNNL is developing a world-class analytical electron microscopy facility dedicated to the characterization of radiological materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Energy and Water Conservation Assessment of the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory

This report summarizes the results of an energy and water conservation assessment of the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory (PNNL). The assessment was performed in October 2013 by engineers from the PNNL Building Performance Team with the support of the dedicated RPL staff and several Facilities and Operations (F&O) department engineers. The assessment was completed for the Facilities and Operations (F&O) department at PNNL in support of the requirements within Section 432 of the Energy Independence and Security Act (EISA) of 2007.

Johnson, Stephanie R.↗

Space Shuttle main engine powerhead structural modeling, stress and fatigue life analysis. Volume 3: Stress summay of blades and nozzles at FPL and 115 percent RPL loads. SSME HPFTP and HPOTP blades and nozzles

Gasdynamic environments applied to the turbine blades and nozzles of the HPFTP and HPOTP were analyzed. Centrifugal loads were applied to blades to account for the pump rotation of FPL and 115 percent RPL. The computer models used in the blade analysis with results presented in the form of temperature and stress contour plots are described. Similar information is given for the nozzles.

Hammett, J. C.↗

Rational design of a uranyl metal-organic framework for the capture and colorimetric detection of organic dyes

A new uranyl containing metal-organic framework, RPL-1: [(UO2)2(C28H18O8)] · H2O (RPL for Radiochemical Processing Laboratory), was prepared, structurally characterized, and the solid-state photoluminescence properties explored. The single crystal X-ray diffraction data reveal the structure of RPL-1 consists of two crystallographically unique three dimensional, interpenetrating nets with a 4,3-connected tbo topology. Each net contains large pores with an average width of 22.8 Å and is formed from monomeric, hexagonal bipyramidal uranyl nodes that are linked via 1,2,4,5-tetrakis(4-carboxyphenyl)benzene (TCPB) linkers. The thermal and photophysical properties of RPL-1 were investigated using thermogravimetric analysis and absorbance, fluorescence, and lifetime spectroscopies. The material displays excellent thermal stability and temperature dependent uranyl and TCBP luminescence. The framework is stable in aqueous media and due to the large void space (constituting 76% of the unit cell by volume) can sequester organic dyes, the uptake of which induces a visible change to the color of the material.

Surbella, Robert G.↗

Space Shuttle Main Engine Off-Nominal Low Power Level Operation

This paper describes Rocketdyne's successful analysis and demonstration of the Space Shuttle Main Engine (SSME) operation at off-nominal power levels during Reusable Launch Vehicle (RLV) evaluation tests. The nominal power level range for the SSME is from 65% rated power level (RPL) to 109% RPL. Off-nominal power levels incrementally demonstrated were: 17% RPL, 22% RPL, 27% RPL, 40% RPL, 45% RPL, and 50% RPL. Additional achievements during low power operation included: use of a hydrostatic bearing High Pressure Oxidizer Turbopump (HPOTP), nominal High Pressure Fuel Turbopump (HPFTP) first rotor critical speed operation, combustion stability at low power levels, and refined definition of nozzle flow separation heat loads.

Bradley, Michael↗

Thread/OpenThread: A Compromise in Low-Power Wireless Multihop Network Architecture for the Internet of Things

Extending an Internet subnet by connecting resource-constrained nodes (e.g., embedded sensors and actuators) over multiple wireless hops is necessary to support the future Internet of Things (IoT). RPL, the IPv6 routing standard for low-power and lossy networks, tried to achieve this goal but has not seen wide adoption in practice. As an alternative, Thread is a recently standardized low-power network protocol for IoT, driven by the Thread group, an industry consortium led by Google/Nest. Here, we provide a comparative analysis of the technical aspects of RPL and Thread based on their specifications, explaining why using Thread, as opposed to RPL, may make sense for the future Internet. Specifically, the fundamental differences between RPL and Thread are their respective scopes and multihop network architectures, which result in Thread's unique design and advantages over RPL. Lastly, we evaluate Thread in an indoor multihop wireless testbed using OpenThread, an official open source implementation of Thread. This work serves as the first analysis of the Thread protocol in academia.

30 DIRECT ENERGY CONVERSION↗

SU-F-T-175: Absorbed Dose Measurement Using Radiophotoluminescent Glass Dosimeter in Therapeutic Proton Beam

Purpose: To measure the absorbed dose to water Dw in therapeutic proton beam with radiophotoluminescent glass dosimeter (RGD), a methodology was proposed. In this methodology, the correction factor for the LET dependence of radiophotoluminescent (RPL) efficiency and the variation of mass stopping power ratio of water to RGD (SPRw, RGD) were adopted. The feasibility of proposed method was evaluated in this report. Methods: The calibration coefficient in terms of Dw for RGDs (GD-302M, Asahi Techno Glass) was obtained using 60Co beam. The SPRw, RGD was calculated by Monte Carlo simulation toolkit Geant4. The LET dependence of RPL efficiency was investigated experimentally by using a 70 MeV proton beam at National Institute of Radiological Sciences. For clinical usage, the residual range Rres was used as a quality index to determine the correction factor for RPL efficiency. The proposed method was evaluated by measuring Dw at difference depth in the 200 MeV proton beam. Results: For both modulated and non-modulated proton beam, the SPRw, RGD increases more than 3 % where Rres are less than 1 cm. RPL efficiency decreases with increasing LET and it reaches 0.6 at LET of 10 keV µm{sup −1}. Dw measured by RGD (Dw, RGD) shows good agreement with that measured by ionization chamber (Dw, IC) and the relative difference between Dw, RGD and Dw, IC are within 3 % where Rres is larger than 1 cm. Conclusion: In this work, a methodology for using RGD in proton dosimetry was proposed and the SPRw, RGD and the LET dependence of RPL efficiency in therapeutic proton beam was investigated. The results revealed that the proposed method is useful for RGD in the dosimetry of proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

Radiation-induced changes in the optical properties of NaMgF3(Sm): Observation of resettable Sm radio-photoluminescence

Highlights: • NaMgF{sub 3}(Sm) shows photoluminescence from Sm{sup 3+} and Sm{sup 2+}. • Optically stimulated luminescence occurs via Sm{sup 3+}. • Stable valence conversion from Sm{sup 3+} to Sm{sup 2+} is induced by X-ray irradiation. • The Sm valence ratio can be used to non-destructively measure doses up to ∼500 Gy. • The Sm valence conversion can be reversed by deep UV stimulation. - Abstract: Stable radio-photoluminescence (RPL) is observed in NaMgF{sub 3}(Sm) after X-ray irradiation due to valence conversion of Sm{sup 3+} to Sm{sup 2+}. This valence conversion can be reversed by deep UV (254 nm) illumination. It is likely that this reversible process occurs via defects near some of the Sm{sup 3+} sites that act as hole traps. The ratio of the Sm{sup 2+}/Sm{sup 3+} RPL emissions follows an exponential-type curve dependence on X-ray dose where the ratio saturates above ∼500 Gy. Optically stimulated luminescence (OSL) is also observed but only from Sm{sup 3+} and primarily from electrons trapped at F-centers. The OSL response is demonstrated to be linear up to 100 Gy. Thus, NaMgF{sub 3}(Sm) has potential as a dosimeter where individual irradiations can be monitored via OSL and the total cumulative dose via non-destructive RPL readout. The RPL can be optically reset when required.

36 MATERIALS SCIENCE↗

Applying Model-based Diagnosis to a Rapid Propellant Loading System

The overall objective of the US Air Force Research Laboratory (AFRL) Rapid Propellant Loading (RPL) Program is to develop a launch vehicle, payload and ground support equipment that can support a rapid propellant load and launch within one hour. NASA Kennedy Space Center (KSC) has been funded by AFRL to develop hardware and software to demonstrate this capability. The key features of the software would be the ability to recognize and adapt to failures in the physical hardware components, advise operators of equipment faults and workarounds, and put the system in a safe configuration if unable to fly. In December 2008 NASA KSC and NASA Ames Research Center (ARC) demonstrated model based simulation and diagnosis capabilities for a scaled-down configuration of the RPL hardware. In this paper we present a description of the model-based technologies that were included as part of this demonstration and the results that were achieved. In continuation of this work we are currently testing the technologies on a simulation of the complete RPL system. Later in the year, when the RPL hardware is ready, we will be integrating these technologies with the real-time operation of the system to provide live state estimates. In future years we will be developing the capability to recover from faulty conditions via redundancy and reconfiguration.

Goodrich, Charlie H.↗

SU-E-T-41: Analysis of GI Dose Variability Due to Intrafraction Setup Variance

Purpose: Proton SBRT (stereotactic body radiation therapy) can be an effective modality for treatment of gastrointestinal tumors, but limited in practice due to sensitivity with respect to variation in the RPL (radiological path length). Small, intrafractional shifts in patient anatomy can lead to significant changes in the dose distribution. This study describes a tool designed to visualize uncertainties in radiological depth in patient CT's and aid in treatment plan design. Methods: This project utilizes the Shadie toolkit, a GPU-based framework that allows for real-time interactive calculations for volume visualization. Current SBRT simulation practice consists of a serial CT acquisition for the assessment of inter- and intra-fractional motion utilizing patient specific immobilization systems. Shadie was used to visualize potential uncertainties, including RPL variance and changes in gastric content. Input for this procedure consisted of two patient CT sets, contours of the desired organ, and a pre-calculated dose. In this study, we performed rigid registrations between sets of 4DCT's obtained from a patient with varying setup conditions. Custom visualizations are written by the user in Shadie, permitting one to create color-coded displays derived from a calculation along each ray. Results: Serial CT data acquired on subsequent days was analyzed for variation in RPB and gastric content. Specific shaders were created to visualize clinically relevant features, including RPL (radiological path length) integrated up to organs of interest. Using pre-calculated dose distributions and utilizing segmentation masks as additional input allowed us to further refine the display output from Shadie and create tools suitable for clinical usage. Conclusion: We have demonstrated a method to visualize potential uncertainty for intrafractional proton radiotherapy. We believe this software could prove a useful tool to guide those looking to design treatment plans least insensitive to motion for patients undergoing proton SBRT in the GI tract.

60 APPLIED LIFE SCIENCES↗

SU-E-T-455: Impact of Different Independent Dose Verification Software Programs for Secondary Check

Purpose: There have been many reports for different dose calculation algorithms for treatment planning system (TPS). Independent dose verification program (IndpPro) is essential to verify clinical plans from the TPS. However, the accuracy of different independent dose verification programs was not evident. We conducted a multi-institutional study to reveal the impact of different IndpPros using different TPSs. Methods: Three institutes participated in this study. They used two different IndpPros (RADCALC and Simple MU Analysis (SMU), which implemented the Clarkson algorithm. RADCALC needed the input of radiological path length (RPL) computed by the TPSs (Eclipse or Pinnacle3). SMU used CT images to compute the RPL independently from TPS). An ion-chamber measurement in water-equivalent phantom was performed to evaluate the accuracy of two IndpPros and the TPS in each institute. Next, the accuracy of dose calculation using the two IndpPros compared to TPS was assessed in clinical plan. Results: The accuracy of IndpPros and the TPSs in the homogenous phantom was +/−1% variation to the measurement. 1543 treatment fields were collected from the patients treated in the institutes. The RADCALC showed better accuracy (0.9 ± 2.2 %) than the SMU (1.7 ± 2.1 %). However, the accuracy was dependent on the TPS (Eclipse: 0.5%, Pinnacle3: 1.0%). The accuracy of RADCALC with Eclipse was similar to that of SMU in one of the institute. Conclusion: Depending on independent dose verification program, the accuracy shows systematic dose accuracy variation even though the measurement comparison showed a similar variation. The variation was affected by radiological path length calculation. IndpPro with Pinnacle3 has different variation because Pinnacle3 computed the RPL using physical density. Eclipse and SMU uses electron density, though.

60 APPLIED LIFE SCIENCES↗

Communications Plan for the Radiochemical Processing Laboratory Life Extension Plan

The Radiochemical Processing Laboratory Life Extension Plan (RPL-ELP) is a collection of independent projects that enable the life extensions of the Radiochemical Processing Laboratory to provide continuous, safe, and secure research operations in support of Department of Energy missions. The ELP includes facility infrastructure upgrades, laboratory and equipment upgrades, and increased research capacity through conversion of existing spaces to the current Pacific Northwest National Laboratory (PNNL) standards. This communications plan is a living document that outlines the goals, target audiences and objectives, key messages, communications opportunities, and tactics for those communications products. This plan will help to make sure communications are coordinated and consistent. Periodically, PNNL will review the communications plan to make sure it addresses current needs of the RPL-ELP.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

EVALUATION OF AN UPWARD TREND IN BACKGROUND COUNT RATES FROM A STACK PARTICULATE CONTINUOUS AIR MONITOR

The Pacific Northwest National Laboratory (PNNL) operates the Radiochemical Processing Laboratory (RPL), which is a multi-purpose, non-reactor nuclear research facility. Regulations require both continuous sampling and monitoring of radioactive particulates and tritium gas in the exhaust from the main stack. Releases of other radioactive gases, including planned releases of radon, are tracked separately in a database and reported. During the 2015 calibration of the RPL stack continuous air monitor (CAM), measured alpha and beta background count rates were much higher than expected, especially when compared to count rates from previous calibrations. The source of the higher background count rates was examined by trending of historical CAM measurements and a comparison to the sampler data. The analysis revealed that the sample results showed no increase in emissions, whereas the CAM showed a steady increase in count rates. Ultimately, the CAM filter was analyzed and found to contain higher-than-normal background levels of 220Rn progeny. Assessments were performed to determine the cause of the increased background values, including reviews of building research activities, radioactive material usage and storage, adequacy of procedures, and the potential for internal CAM contamination. Project reviews determined that a research activity involving 228Th was left in a semi-stored state, resulting in 220Rn being released from a hot cell into the exhaust system. The 228Th source material was subsequently repackaged and contained resulting in a decrease of CAM background count rates. An estimate of the 220Rn release was made and the contribution to the annual offsite dose from the facility was calculated. The released activity and reported dose results were well below the permit limits for the facility.

radon, 220Rn, environmental assessment, air monito↗