Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RING DISCHARGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characterization of hollow cathode, ring cusp discharge chambers

An experimental study into the effects of changes in such physical design parameters as hollow cathode position, anode position and ring cusp magnetic field configuration and strength on discharge chamber performance, is described. The results are presented in terms of comparative plasma ion energy cost, extracted ion fraction and ion beam profile data. Such comparisons are used to demonstrate specific means by which changes in these design parameters induce changes in performance, i.e., through changes in the loss rates of primary electrons to the anode, of ions to discharge chamber walls or of ions to cathode and anode surfaces. Results show: (1) the rate of primary electron loss to the anode decreases as the anode is moved downstream of the ring cusp toward the screen grid, (2) the loss rate of ions to hollow cathode surfaces are excessive if the cathode is located upstream of a point of peak magnetic flux density on the discharge chamber centerline, and (3) the fraction of the ions produced that are lost to discharge chamber walls and ring magnet surfaces is reduced by positioning the magnet rings so the plasma density is uniform over the grid surface and so there are no steep magnetic flux density gradients near the walls through which ions can be lost by Bohm diffusion. The uniformity of the plasma density at the grids can also be improved by moving the point of primary electron injection into the discharge chamber off of the chamber centerline. Other results show the discharge chamber losses decrease when a filament cathode is substituted for a hollow cathode to the extent of the hollow cathode operating power. When plasma ion energy cost is determined in such a way that the cost of operating the hollow cathode is subtracted out, the performance using either electron source is similar.

Vaughn, Jason A.↗

Ring cusp discharge chamber performance optimization

An experimental study of the effects of discharge chamber length and the locations of the anode, cathode and ring cusp within the chamber on the performance of an 8 cm dia. ring cusp thruster is described. As these lengths and positions are varied the changes induced in plasma ion energy costs, extracted ion fractions and ion beam profiles are measured. Results show that the anode may be positioned at any location along an 'optimum virtual anode' magnetic field line and minimum plasma ion energy costs will result. The actual location of this field line is related to a 'virtual cathode' magnetic field line that is defined by the cathode position. The magnetic field has to be such that the virtual anode field line intersects the grids at the outermost ring of grid holes to maximize the extracted ion fraction and flatten the ion beam profile. Discharge chamber lengths that were as small as possible in the test apparatus yielded the lowest extracted ion fractions.

Hiatt, J. M.↗

Characteristics of ring-cusp discharge chambers

Measurements have been obtained for the operating characteristics of a 30 cm diameter ring-cusp ion thruster (RCIT), quantitatively comparing its performance parameters to those of a divergent-field J-series cluster of the same size. The high level of performance established for the RCIT is due to its maintenance of both a higher primary-electron population and Maxwellian-electron temperature, as the beam-ion production cost is reduced to its baseline value. Ion losses to the discharge-chamber walls can be reduced by an applied electrostatic field.

Matossian, J. N.↗

Characterization of Downstream Ion Energy Distributions From a High Current Hollow Cathode in a Ring Cusp Discharge Chamber

The presence of energetic ions produced by a hollow cathodes operating at high emission currents (greater than 10 Angstroms) has been documented in the literature. As part of an ongoing effort to uncover the underlying physics of the formation of these ions, ion efflux from a high current hollow cathode operating in an ion thruster discharge chamber was investigated. Using a spherical sector electrostatic energy analyzer located downstream of the discharge cathode, the ion energy distribution over a 0 to 60 eV energy range was measured. The sensitivity of the ion energy distribution function to zenith angle was also assessed at 3 different positions: 0, 15, and 25 degrees. The measurements suggest that the majority of the ion current at the measuring point falls into the analyzer with an energy approximately equal to the discharge voltage. The ion distribution, however, was found to be quite broad. The high energy tail of the distribution function tended to grow with increasing discharge current. Sensitivity of the profiles to flow rate at fixed discharge current was also investigated. A simple model is presented that provides a potential mechanism for the production of ions with energies above the discharge voltage.

Foster, John E.↗

Development of large volume double ring penning plasma discharge source for efficient light emissions

In this paper, the development of large volume double ring Penning plasma discharge source for efficient light emissions is reported. The developed Penning discharge source consists of two cylindrical end cathodes of stainless steel having radius 6 cm and a gap 5.5 cm between them, which are fitted in the top and bottom flanges of the vacuum chamber. Two stainless steel anode rings with thickness 0.4 cm and inner diameters 6.45 cm having separation 2 cm are kept at the discharge centre. Neodymium (Nd{sub 2}Fe{sub 14}B) permanent magnets are physically inserted behind the cathodes for producing nearly uniform magnetic field of {approx}0.1 T at the center. Experiments and simulations have been performed for single and double anode ring configurations using helium gas discharge, which infer that double ring configuration gives better light emissions in the large volume Penning plasma discharge arrangement. The optical emission spectroscopy measurements are used to complement the observations. The spectral line-ratio technique is utilized to determine the electron plasma density. The estimated electron plasma density in double ring plasma configuration is {approx}2 Multiplication-Sign 10{sup 11} cm{sup -3}, which is around one order of magnitude larger than that of single ring arrangement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ring cusp/hollow cathode discharge chamber performance studies

An experimental study performed to determine the effects of hollow cathode position, anode position, and ring cusp magnetic field configuration and strength on discharge chamber performance is described. The results are presented in terms of comparative plasma ion energy cost, extracted ion fraction, and beam profile data. Results show that the rate of primary electron loss to the anode decreases as the anode is moved downstream of the ring cusp toward the screen grid and that the loss rate of ions to hollow cathode surfaces are excessive if the cathode is located upstream of a point of peak magnetic flux density at the discharge chamber centerline. Moreover, the fraction of the ions produced that are lost to discharge chamber walls and ring magnet surfaces is reduced by positioning of the magnet rings so the plasma density is uniform over the grid surface, and adjusting their strength to a level where it is sufficient to prevent excessive ion losses by Bohm diffusion.

Vaughn, J. A.↗

Ring cusp/hollow cathode discharge chamber performance studies

An experimental study was performed to determine the effects of hollow cathode position, anode position, and ring cusp magnetic field configuration and strength on discharge chamber performance. The results are presented in terms of comparative plasma ion energy cost, extracted ion fraction, and beam profile data. Such comparisons are used to demonstrate whether changes in performance are caused by changes in the loss rate of primary electrons to the anode or the loss rate of ions to discharge chamber walls or cathode and anode surfaces. Results show: (1) the rate of primary electron loss to the anode decreases as the anode is moved downstream of the ring cusp toward the screen grid; (2) the loss rate of ions to hollow cathode surfaces are excessive if the cathode is located upstream of a point of peak magnetic flux density at the discharge chamber centerline; and (3) the fraction of the ions produced that are lost to discharge chamber walls and ring magnet surfaces is reduced by positioning of the magnet rings so the plasma density is uniform over the grid surface, and adjusting their strength to a level where it is sufficient to prevent excessive ion losses by Bohm diffusion.

Vaughn, J. A.↗

Magnetic confinement in a ring-cusp ion thruster discharge plasma

An experimental investigation, in conjunction with a volume averaged analytical model, has been developed to improve the confinement and production of the discharge plasma for plasma thrusters and ion sources. The research conducted explores the discharge performance of a ring-cusp ion source based on the magnetic field configuration, geometry, and power level. Analytical formulations for electron and ion confinement are developed to predict the ionization efficiency for a given discharge chamber design. Explicit determination of discharge loss and volume averaged plasma parameters are obtained via a series of experimental measurements on a ring-cusp NASA Solar Technology Application Readiness (NSTAR) ion thruster to assess the validity of the analytical model. Measurements of the discharge loss with multiple magnetic field configurations compare well with plasma parameter predictions for propellant utilizations between 80% and 95%. The results indicate that increasing the magnetic strength of the first closed magnetic contour line reduces Maxwellian electron diffusion and electrostatically confines the ion population and subsequent loss to the anode wall. The results also indicate that increasing the strength and minimizing the area of the magnetic cusps improves primary electron confinement, increasing the probability of an ionization collision prior to loss at the cusp.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulsed Discharge Nozzle Cavity Ring Down Spectroscopy of Cold PAH Ions

The gas-phase electronic absorption spectra of the naphthalene (C10H8(+)) and acenaphthene (C12H10(+)) cations have been measured in the visible range in a free 10 jet planar expansion in an attempt to collect data in an astrophysically relevant environment. The direct absorption spectra of two out of four bands measured of the gas-phase cold naphthalene cation along with the gas-phase vibronic absorption spectrum of the cold acenaphthene cation are reported for the first time. The study has been carried out using the ultrasensitive and versatile technique of cavity ringdown spectroscopy (CRDS) coupled to a pulsed discharge slit nozzle (PDN). The new CRDS-PDN set up is described and its characteristics are evaluated. The direct-absorption spectra of the PAH ions are discussed and compared to the gas-phase and solid-phase data available in the literature. The analysis of the results show that cold, free flying PAH ions are generated in the argon discharge primarily through soft Penning ionization. This enables the intrinsic band profiles to be measured, a key requirement for astrophysical applications.

Biennier, Ludovic↗

Axisymmetric electric discharge as a means for distant heating of gas media

Gas-dynamic phenomena accompanying a ring electric discharge excited in atmospheric-pressure air have been studied experimentally and theoretically. It is shown experimentally that the discharge generates a toroidal (three-dimensional) shock wave that converges toward the axis. A mathematical model describing the focusing of a toroidal shock wave is constructed. The measured characteristics of shock processes accompanying the discharge agree well with results of calculations. This makes it possible to estimate the gas temperature that can be achieved in the convergent shock wave at a certain distance from the center of the ring discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Criteria of radio-frequency ring-shaped hollow cathode discharge using H{sub 2} and Ar gases for plasma processing

In order to achieve high-density capacitively coupled plasma, a radio-frequency (RF) ring-shaped hollow cathode discharge has been developed as a candidate for processing plasma sources. The plasma density in the hollow cathode discharge reaches a high magnitude of 10{sup 10}-10{sup 11} cm{sup -3}. The RF ring-shaped hollow cathode discharge depends on the pressure and mass of the working gas. Criteria required for producing a RF ring-shaped hollow cathode discharge have been investigated for various gas pressures using H{sub 2} and Ar gases for high-density plasma production. The results reveal that the criteria for the occurrence of the hollow cathode effect are that the trench width should be approximately equal to the sum of the electron-neutral mean free paths and twice the sheath thickness of the RF powered electrode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation of a Plasma Ring by a Microwave Discharge in a Narrow Coaxial Cavity beyond the ECR Region

Results are presented from the experimental study of conditions for the formation of a plasma ring by a microwave discharge in a narrow coaxial cavity in an axisymmetric magnetic field the magnitude of which is below the electron-cyclotron resonance value. It is established that the necessary condition for this process is the presence of an electrostatic wave propagating in the azimuthal direction, the circumference of the plasma ring being a multiple of the wave half-length.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced Discharge Performance in a Ring Cusp Plasma Source

There is a need for a lightweight, low power ion thruster for space science missions. Such an ion thruster is under development at NASA Glenn Research Center. In an effort to better understand the discharge performance of this thruster, a thruster discharge chamber with an anode containing electrically isolated electrodes at the cusps was fabricated and tested. Characteristics of this ring cusp ion discharge were measured without ion beam extraction. Discharge current was measured at collection electrodes located at the magnetic cusps and at the anode body itself. Discharge performance and plasma properties were measured as a function of power, which was varied between 20 and 50 W. It was found that ion production costs decreased by as much as 20 percent when the two most downstream cusp electrodes were allowed to float. Floating the electrodes did not give rise to a significant increase in discharge power even though the plasma density increased markedly. The improved performance is attributed to enhanced electron containment.

Foster, John E.↗

Development of a 50,000-s, Lithium-fueled, Gridded Ion Thruster

The ion propulsion system on NASA’s Dawn mission provided over 11 km/s delta-V to the spacecraft. There is potential interest in missions that have delta-V’s an order of magnitude greater than this, i.e., 100 km/s to 200 km/s. To perform such missions would require a thruster that can produce a specific impulse roughly an order of magnitude greater than the 3100 s of the Dawn ion propulsion system. A 50-kW gridded ion thruster is being developed for operation with lithium propellant to produce a specific impulse of 50,000 s. The resulting thruster design requires a net accelerating voltage of 9 kV and a beam current of 5.5 A. Discharge chamber modeling is used to design a 35-cm diameter ring-cusp discharge chamber with six magnet rings. The discharge chamber is masked down to produce an active grid area that is ~25 cm diameter. Modeling suggests that the unique ionization characteristics of lithium may enable discharge chamber operation at a propellant efficiency of 99%. Operation at such a high propellant efficiency could significantly reduce the production of charge-exchange ions and thereby significantly reduce erosion of the accelerator grid.

Goebel, Dan M.↗