Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RF ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Alternative modeling methods for plasma-based Rf ion sources

Rf-driven ion sources for accelerators and many industrial applications benefit from detailed numerical modeling and simulation of plasma characteristics. For instance, modeling of the Spallation Neutron Source (SNS) internal antenna H{sup −} source has indicated that a large plasma velocity is induced near bends in the antenna where structural failures are often observed. This could lead to improved designs and ion source performance based on simulation and modeling. However, there are significant separations of time and spatial scales inherent to Rf-driven plasma ion sources, which makes it difficult to model ion sources with explicit, kinetic Particle-In-Cell (PIC) simulation codes. In particular, if both electron and ion motions are to be explicitly modeled, then the simulation time step must be very small, and total simulation times must be large enough to capture the evolution of the plasma ions, as well as extending over many Rf periods. Additional physics processes such as plasma chemistry and surface effects such as secondary electron emission increase the computational requirements in such a way that even fully parallel explicit PIC models cannot be used. One alternative method is to develop fluid-based codes coupled with electromagnetics in order to model ion sources. Time-domain fluid models can simulate plasma evolution, plasma chemistry, and surface physics models with reasonable computational resources by not explicitly resolving electron motions, which thereby leads to an increase in the time step. This is achieved by solving fluid motions coupled with electromagnetics using reduced-physics models, such as single-temperature magnetohydrodynamics (MHD), extended, gas dynamic, and Hall MHD, and two-fluid MHD models. We show recent results on modeling the internal antenna H{sup −} ion source for the SNS at Oak Ridge National Laboratory using the fluid plasma modeling code USim. We compare demonstrate plasma temperature equilibration in two-temperature MHD models for the SNS source and present simulation results demonstrating plasma evolution over many Rf periods for different plasma temperatures. We perform the calculations in parallel, on unstructured meshes, using finite-volume solvers in order to obtain results in reasonable time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RF synchronized short pulse laser ion source

A laser ion source that produces shortly bunched ion beam is proposed. In this ion source, ions are extracted immediately after the generation of laser plasma by an ultra-short pulse laser before its diffusion. The ions can be injected into radio frequency (RF) accelerating bucket of a subsequent accelerator. As a proof-of-principle experiment of the ion source, a RF resonator is prepared and H{sub 2} gas was ionized by a short pulse laser in the RF electric field in the resonator. As a result, bunched ions with 1.2 mA peak current and 5 ns pulse length were observed at the exit of RF resonator by a probe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

rf improvements for Spallation Neutron Source H{sup -} ion source

The Spallation Neutron Source at Oak Ridge National Laboratory is ramping up the accelerated proton beam power to 1.4 MW and just reached 1 MW. The rf-driven multicusp ion source that originates from the Lawrence Berkeley National Laboratory has been delivering {approx}38 mA H{sup -} beam in the linac at 60 Hz, 0.9 ms. To improve availability, a rf-driven external antenna multicusp ion source with a water-cooled ceramic aluminum nitride (AlN) plasma chamber is developed. Computer modeling and simulations have been made to analyze and optimize the rf performance of the new ion source. Operational statistics and test runs with up to 56 mA medium energy beam transport beam current identify the 2 MHz rf system as a limiting factor in the system availability and beam production. Plasma ignition system is under development by using a separate 13 MHz system. To improve the availability of the rf power system with easier maintenance, we tested a 70 kV isolation transformer for the 80 kW, 6% duty cycle 2 MHz amplifier to power the ion source from a grounded solid-state amplifier.

43 PARTICLE ACCELERATORS↗

Multi-antenna RF Ion Source at a High RF Power Level

A multi-antenna radio-frequency ion source with a Faraday shield is newly tested at a high RF power level in a large area negative ion source of 1/5th scale of the Large Helical Device-NNBI ion source. Inductively coupled dense hydrogen plasmas were generated uniformly over an area of 25x25 cm{sup 2} at an RF input power up to 300 kW for a 10 ms pulse duration. A large negative plasma potential for the non-Faraday shielded antenna was remarkably reduced by introducing a Faraday shield. The positive ion saturation current density measured by Langmuir probe reached 148 mA/cm{sup 2} at 174 kW around the center of the plasma. The optimal hydrogen filling pressure ranged around 0.13 Pa- 0.4 Pa for the positive ions. Ion beam extraction with a single hole ({phi} 0.5 cm) extractor has been studied systematically. A maximum H{sup -} ion beam current density of 1.6 mA/cm{sup 2} was obtained preliminarily. It was confirmed that the plasma profile was controllable by both the number and configuration of the antennas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High homogeneity 25 cm low-energy rf ion source with inherent electron compensation

A 25 cm single-grid low-energy rf ion source with inherent electron compensation is described and characterized. Measurements were carried out using Ar and CF{sub 4} filling gas. The dependence of the ion beam current to the target as well as the current partition between the beam fast and slow ions on the rf discharge pressure for both filling gases is discussed. The unique ability of generation of coinciding ion and electron flows is demonstrated and the measured ion and electron energy distribution functions are presented as well. The developed broad ion beam source is able of providing 0.5-5 mA/cm{sup 2} current density in the low ion energy range of 50-250 eV, with possibility of independent current density and energy control. It is shown that complementing the rf plasma source with a profiling electrode allows for CF{sub 4} ion source operation attaining {+-}5% ion beam uniformity over 250 mm in diameter. The presented CF{sub 4} etching test results exhibit the possibility of highly directional anisotropic Si and SiO{sub 2} etching utilizing the developed single grid rf ion source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

H - Ion Source RF Plasma Testing with 13 MHz and 27 MHz at the Spallation Neutron Source (SNS)

The baseline RF-driven H⁻ ion source configuration at the Spallation Neutron Source (SNS) facility uses a continuous wave (CW) 600 W 13 MHz RF system to ignite and maintain a low-density plasma inside the ion source vacuum chamber. After the continuous low-density 13 MHz plasma has been established, a pulsed (typical 1 ms pulse width and 60 Hz pulse repetition rate) 80 kW 2 MHz RF system is used to increase the plasma density to produce the pulsed H⁻ ion beam. Incremental upgrades and improvements to the SNS ion source systems have resulted in the ability to reliably operate an H⁻ ion source for SNS neutron production run cycles that can last up to four months. Conditions inside the SNS H⁻ ion source evolve throughout a four-month run cycle due to changes in impurity levels, sputtering, and erosion. As the internal ion source conditions change during the run cycle, there can also be changes in plasma stability and the 13 MHz RF power level required to ignite the plasma. This paper presents the preliminary results of testing performed on the SNS Ion Source Test Stand (ISTS) system where we looked at plasma ignition and plasma stability using 27 MHz RF in place of the baseline 13 MHz RF system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

BROADBAND ANTENNA MATCHING NETWORK DESIGN AND APPLICATION FOR RF PLASMA ION SOURCE

The RF ion source at Spallation Neutron Source has been upgraded to meet higher beam power requirement. One important subsystem for efficient operation of the ion source is the 2MHz RF impedance matching network. The real part of the antenna impedance is very small and is affected by plasma density for 2MHz operating frequency. Previous impedance matching network for the antenna has limited tuning capability to cover this potential variation of the antenna impedance since it employed a single tuning element and an impedance transformer. A new matching network with two tunable capacitors has been built and tested. This network can allow precision matching and increase the tunable range without using a transformer. A 5-element broadband matching network also has been designed, built and tested. The 5-element network allows wide band matching up to 50 kHz bandwidth from the resonance center of 2 MHz. The design procedure, simulation and test results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Saddle antenna radio frequency ion sources

Existing RF ion sources for accelerators have specific efficiencies for H{sup +} and H{sup −} ion generation ∼3–5 mA/cm{sup 2} kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) surface plasma source (SPS) described here was developed to improve H{sup −} ion production efficiency, reliability, and availability. In SA RF ion source, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm{sup 2} kW. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power ∼1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with ∼4 kW RF. Continuous wave (CW) operation of the SA SPS has been tested on the test stand. The general design of the CW SA SPS is based on the pulsed version. Some modifications were made to improve the cooling and cesiation stability. CW operation with negative ion extraction was tested with RF power up to ∼1.2 kW in the plasma with production up to Ic = 7 mA. A stable long time generation of H{sup −} beam without degradation was demonstrated in RF discharge with AlN discharge chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact RF ion source for industrial electrostatic ion accelerator

Korea Multi-purpose Accelerator Complex is developing a single-ended electrostatic ion accelerator to irradiate gaseous ions, such as hydrogen and nitrogen, on materials for industrial applications. ELV type high voltage power supply has been selected. Because of the limited space, electrical power, and robust operation, a 200 MHz RF ion source has been developed. In this paper, the accelerator system, test stand of the ion source, and its test results are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a cavity ring-down spectroscopy diagnostic for negative ion rf source SPIDER

The rf source test facility SPIDER will test and optimize the source of the 1 MV neutral beam injection systems for ITER. Cavity ring-down spectroscopy (CRDS) will measure the absolute line-of-sight integrated density of negative (H{sup -} and D{sup -}) ions, produced in the extraction region of the source. CRDS takes advantage of the photodetachment process: negative ions are converted to neutral hydrogen atoms by electron stripping through absorption of a photon from a laser. The design of this diagnostic is presented with the corresponding simulation of the expected performance. A prototype operated without plasma has provided CRDS reference signals, design validation, and results concerning the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alternative RF coupling configurations for H{sup −} ion sources

RF heated sources for negative hydrogen ions both for fusion and accelerators require very high RF powers in order to achieve the required H{sup −} current what poses high demands on the RF generators and the RF circuit. Therefore it is highly desirable to improve the RF efficiency of the sources. This could be achieved by applying different RF coupling concepts than the currently used inductive coupling via a helical antenna, namely Helicon coupling or coupling via a planar ICP antenna enhanced with ferrites. In order to investigate the feasibility of these concepts, two small laboratory experiments have been set up. The PlanICE experiment, where the enhanced inductive coupling is going to be investigated, is currently under assembly. At the CHARLIE experiment systematic measurements concerning Helicon coupling in hydrogen and deuterium are carried out. The investigations show that a prominent feature of Helicon discharges occurs: the so-called low-field peak. This is a local improvement of the coupling efficiency at a magnetic field strength of a few mT which results in an increased electron density and dissociation degree. The full Helicon mode has not been achieved yet due to the limited available RF power and magnetic field strength but it might be sufficient for the application of the coupling concept to ion sources to operate the discharge in the low-field-peak region.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of an RF plasma ion source for ion implantation

A novel inductively coupled RF plasma ion source has been developed for use in a beamline ion implanter. Ion density data have been taken with an array of four Langmuir probes spaced equally at the source extraction arc slit. These provide ion density uniformity information as a function of source pressure, RF power and gas mixture composition. In addition, total extracted ion beam current data are presented for the same conditions. The comparative advantages of the RF source in terms of higher beam current, reduced maintenance and overall productivity improvement compared to a hot cathode source are discussed.

43 PARTICLE ACCELERATORS↗

Analysis of Discharge Initiation in a RF Hydrogen Negative Ion Source

The maintenance free RF ion source is expected to be one of the most promising candidates for the negative ion sources of plasma heating for fusion reactors. In order to make clear the condition for the discharge initiation of the RF source, we are developing an electromagnetic PIC model. The numerical result shows that a positive potential built-up with respect to the wall. As a result, the electron wall loss decreases and the electron density increases. The positive potential plays a key role for the suppression of wall loss and the electron confinement. The electromagnetic-PIC model developed is useful for the analysis of discharge initiation of the RF source.

07 ISOTOPE AND RADIATION SOURCES↗

Development and preliminary results of radio frequency ion source

A radio frequency (RF) ion source was designed and developed for neutral beam injector. A RF driver test bed was used with a RF generator with maximum power of 25 kW with 1 MHz frequency and a matching box. In order to study the characteristic of RF plasma generation, the capacitance in the matching box was adjusted with different cases. The results show that lower capacitance will better the stability of the plasma with higher RF power. In the future, new RF coils and matching box will be developed for plasma generators with higher RF power of 50 kW.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress and future developments of high current ion source for neutral beam injector in the ASIPP

A high current hot cathode bucket ion source, which based on the US long pulse ion source is developed in Institute of Plasma Physics, Chinese Academy of Sciences. The ion source consists of a bucket plasma generator with multi-pole cusp fields and a set of tetrode accelerator with slit apertures. So far, four ion sources are developed and conditioned on the ion source test bed. 4 MW hydrogen beam with beam energy of 80 keV is extracted. In Aug. 2013, EAST NBI 1 with two ion source installed on the EAST, and achieved H-mode plasma with NBI injection for the first time. In order to achieve stable long pulse operation of high current ion source and negative ion source research, the RF ion source with 200 mm diameter and 120 mm depth driver is designed and developed. The first RF plasma generated with 2 kW power of 1 MHz frequency. More of the RF plasma tests and negative source relative research need to do in the future.

43 PARTICLE ACCELERATORS↗

Long Pulse H{sup -} Beam Extraction With A RF Driven Ion Source With Low Fraction Of Co-Extracted Electrons

IPP Garching is developing H{sup -}/D{sup -} RF ion sources for the ITER neutral beam system. On the MANITU testbed the experiments are focussed on long pulse H{sup -}/D{sup -} beam extraction with a 100 kW prototype source. The negative ion production is based on surface conversion of atoms and positive ions on Caesium layers. In long pulses with H{sup -} beam extraction the ion currents were stable but with too high fraction of co-extracted electrons. The electron current could be lowered considerably by avoiding copper impurities from the Faraday screen in the plasma which was achieved by coating of the inner surfaces of the source with Molybdenum. A positive bias potential with respect to the source applied to the plasma grid, the bias plate or to a metal rod installed near the plasma grid enables regulation of the electron current during long pulses. In this way low values consistent with the ITER requirements can be achieved without significant loss of ion current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Installation of spectrally selective imaging system in RF negative ion source

A spectrally selective imaging system has been installed in the RF negative ion source in the International Thermonuclear Experimental Reactor-relevant negative ion beam test facility ELISE (Extraction from a Large Ion Source Experiment) to investigate distribution of hydrogen Balmer-α emission (H{sub α}) close to the production surface of hydrogen negative ion. We selected a GigE vision camera coupled with an optical band-path filter, which can be controlled remotely using high speed network connection. A distribution of H{sub α} emission near the bias plate has been clearly observed. The same time trend on H{sub α} intensities measured by the imaging diagnostic and the optical emission spectroscopy is confirmed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of the rf discharge initiation in a negative ion source

The maintenance free rf ion source is expected to be one of the most promising candidates for the negative ion sources of plasma heating for future fusion reactors. As an alternative to the arc-discharge sources, the rf negative ion sources have been developed for H{sup -} production. In order to make clear the condition for the discharge initiation of the rf source, we are developing a numerical model using the finite difference time domain Monte Carlo method to analyze the electron energy distribution function in rf field. The numerical result shows that the discharge is not successfully initiated due to the wall loss unless the wall potential is considered. More self-consistent model including ion dynamics to evaluate the wall potential and the electron loss at the wall will be needed in the future.

43 PARTICLE ACCELERATORS↗