Nomograph for prediction of RF-breakdown voltages

Information in nomograph is derived from data obtained from RF-breakdown tests on components of uniform and nonuniform geometry. Nomograph also can be used in design work to predict breakdown margins; if operational minimum pressure is established giving minimum value on nomograph, minimum breakdown voltage consistent with allowed value can be predicted.

Hickernell, F. S.↗

Breakdown-Resistant RF Connectors for Vacuum

Resilient inserts compensate for insulation shrinkage. Coaxial-cable connector for radio-frequency (RF) energy resists electrical breakdown in vacuum. Used on RF equipment in vacuum chambers as well as in spaceborne radar and communication gear.

Caro, Edward R.↗

RF voltage breakdown and the Paschen curve

A representation based on the similarity relations for voltage breakdown is shown to be useful in combining RF and dc voltage breakdown data. The representation for the uniform field geometry is given.

Woo, R.↗

DAWN Mission Bus and Waveguide Venting Analysis Review

A concern was raised regarding the time after launch when the DAWN Mission Communications Subsystem, which contains a 100 Watt X-Band Traveling Wave Tube Amplifier (TWTA) with a high voltage ((approximately 7 Kilo Volt (KV)) Electronic Power Converter (EPC), will be powered on for the first post-launch downlink. This activation is planned to be approximately one hour after launch. Orbital Sciences (the DAWN Mission spacecraft contractor) typically requires a 24-hour wait period prior to high voltage initiation for Earth-orbiting Science and GEO spacecraft. The concern relates to the issue of corona and/or radio frequency (RF) breakdown of the TWTA ((high voltage direct current (DC) and RF)), and of the microwave components (high voltage RF) in the presence of partial atmospheric pressures or outgassing constituents. In particular, generally the diplexer and circulator are susceptible to RF breakdown in the corona region due to the presence of small physical gaps ((~ 2.5 millimeter (mm)) between conductors that carry an RF voltage. The NESC concurred the DAWN Mission communication system is safe for activation.

Cragg, Clinton H.↗

Design method for minimizing RF voltage breakdown

Research study was conducted and results were published. Using principles of similarity and minimum of experimental data, a number of universal curves have been constructed covering wide range of experimental parameters. Gases other than air, such as argon and carbon dioxide, also are included in study.

Woo, R. T.↗

Radiometric calibration analysis of SIR-B imagery

The second flight of the NASA Spaceborne Imaging Radar (SIR-B) collected nearly 8 hours of digital synthetic-aperture radar (SAR) data of the earth's surface. This paper analyzes the performance of the SAR to determine the accuracy of the relative radiometric calibration of these data. Procedures are presented for deriving accuracy estimates as well as limitations under which these estimates are valid. The impact on calibration of an RF breakdown in the primary antenna feed system cable is evaluated. An analysis of the platform stability based on the SAR echo data is also presented in conjunction with its resultant effect on the calibration accuracy. Finally, numerical error bounds are derived with guidelines on their utilization.

Wall, Stephen D.↗

Investigations of high power problems in space shuttle antenna designs

A study program is discussed which includes a survey of industry and government laboratories and was undertaken to determine the state of the art in dealing with problems of high power levels in reentry antenna design. A laboratory program to develop techniques for testing dielectric materials for effects on RF transmission is also considered, with emphasis on high power applications in space and reentry flights. The study program resulted in a set of guidelines for avoiding breakdown in antenna design. A discussion of temperature effects on dielectric breakdown is also given. From the laboratory program, a description is presented of techniques for (1) heating with a carbon arc image furnace, (2) temperature measurement (using thermocouples and an infrared pyrometer), (3) mass spectrometric monitoring of outgassing, (4) testing for RF breakdown in both heated dielectrics and the dielectric/air and dielectric/plasma interfaces. Data and observations are reported from technique development using candidate shuttle materials falling into three categories: (1) lightweight refractory foams, (2) dense RF window materials, and (3) ablative materials.

Taylor, W. C.↗

Transient response measurements on a satellite system

A set of instruments designed to detect the occurance of electrical breakdown was flown on a synchronous-orbit satellite. The LeRC sensors were installed on cables inside the vehicle. Accordingly, they respond to signals coupled into the satellite wiring system. The SRI sensors were located on the exterior of the vehicle and detected the RF noise pulses associated with surface breakdowns. The results of the earlier SRI program are being used to design and develop a set of intrumentation suitable for inclusion as a general piggy-back package for the detection of the onset of satellite charging and breakdowns on synchronous orbit satellites.

Nanevicz, J. E.↗

High power RF coaxial switch

A coaxial switch capable of operating in a vacuum with high RF power in the 1.2 GHz range without multipactor breakdown, and without relying on pressurization with an inert gas is described. The RF carrying conductors of the switch are surrounded with a high grade solid dielectric, thus eliminating any gaps in which electrons can accelerate.

Caro, E. R.↗

Electron beam charging and arc discharging of spacecraft insulating materials

Samples of Mylar and Teflon film were exposed to combinations of monoenergetic electron and lithium ion fluxes in various ratios. The samples' discharge rates and strengths were found to diminish as the ion proportion increased. Various types of capacitors were exposed in air to beta irradiation from a 100 mCie Strontium-90 radioisotope source located at distances ranging from 2 cm to 5 cm from the capacitors. In these preliminary experiments, no evidence of spontaneous electrical breakdown was noted, nor was any change in RF impedance detectable using the available instrumentation. A decrease in DC resistance was noted, apparently due to radiation-induced conductivity. A cylindrical glass vacuum chamber is being assembled. Its inside dimensions are 44 cm diameter by 100 cm length. All necessary associated components and instruments have been acquired, including electron and ion guns, Trek surface potential probe and turbo-molecular pump. A mass-spectrometer detector for leaks and evolved gases will be ordered shortly.

Balmain, K. G.↗

Design of Refractory Metal Life Test Heat Pipe and Calorimeter

Heat pipe life tests have seldom been conducted on a systematic basis. Typically, one or more heat pipes are built and tested for an extended period at a single temperature with simple condenser loading. Results are often reported describing the wall material, working fluid, test temperature, test duration, and occasionally the nature of any failure. Important information such as design details, processing procedures, material assay, power throughput, and radial power density are usually not mentioned. We propose to develop methods to generate carefully controlled data that conclusively establish heat pipe operating life with material-fluid combinations capable of extended operation. The test approach detailed in this Technical Publication will use 16 Mo-44.5%Re alloy/sodium heat pipe units that have an approximate12-in length and 5/8-in diameter. Two specific test series have been identified: (1) Long-term corrosion rates based on ASTM-G-68-80 (G-series) and (2) corrosion trends in a cross-correlation sequence at various temperatures and mass fluences based on a Fisher multifactor design (F-series). Evaluation of the heat pipe hardware will be performed in test chambers purged with an inert purified gas (helium or helium/argon mixture) at low pressure (10-100 torr) to provide thermal coupling between the heat pipe condenser and calorimeter. The final pressure will be selected to minimize the potential for voltage breakdown between the heat pipe and radio frequency (RF) induction coil (RF heating is currently the planned method of powering the heat pipes). The proposed calorimeter is constructed from a copper alloy and relies on a laminar flow water-coolant channel design to absorb and transport energy

Martin, J. J.↗

Some Notes on Sparks and Ignition of Fuels

This report compliments a concurrent analysis of the electromagnetic field threat to the fuel system of a transport aircraft. The accompanying effort assessed currents, voltages and power levels that may be induced upon fuel tank wiring from radio transmitters (inside and outside the aircraft). In addition to this, it was also essential to determine how much voltage, current, or power is required to create a fuel-vapor ignition hazard. The widely accepted minimum guideline for aircraft fuel-vapor ignition is the application of a 0.2 millijoule energy level. However, when considering radio frequency (RF) sources, this guideline is seriously inadequate. This report endeavors to bridge the gap between a traditional understanding of electrical breakdown, heating and combustion; and supplement the knowledge with available information regarding aircraft fuel-vapor ignition by RF sources

Fisher, Franklin A.↗

An RF Sensor for Gauging Screen-Channel Liquid Acquisition Devices for Cryogenic Propellants

A key requirement of a low-gravity screen-channel liquid acquisition device (LAD) is the need to retain 100% liquid in the channel in response to propellant outflow and spacecraft maneuvers. The point at which a screen-channel LAD ingests vapor is known as breakdown, and can be measured several different ways such as: visual observation of bubbles in the LAD channel outflow; a sudden change in pressure drop between the propellant tank and LAD sump outlet; or, an indication by wet-dry sensors placed in the LAD channel or outflow stream. Here we describe a new type of sensor for gauging a screen-channel LAD, the Radio Frequency Mass Gauge (RFMG). The RFMG measures the natural electromagnetic modes of the screen-channel LAD, which is very similar to an RF waveguide, to determine the amount of propellant in the channel. By monitoring several of the RF modes, we show that the RFMG acts as a global sensor of the LAD channel propellant fill level, and enables detection of LAD breakdown even in the absence of outflow. This paper presents the theory behind the RFMG-LAD sensor, measurements and simulations of the RF modes of a LAD channel, and RFMG detection of LAD breakdown in a channel using a simulant fluid during inverted outflow and long-term stability tests.

microwave sensor↗