Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Utilization of the CW magnetrons as coherent RF sources for superconducting RF accelerators

CW magnetrons designed and optimized for industrial heaters, driven by an injection-locking signal, were suggested to power Superconducting RF (SRF) cavities. However, the CW magnetrons, which are regenerative generators, are intended to operate in self-excitation mode, so, for reliable starting they use a large regenerative gain, causing a large regenerative instability in operation. Thus, power supply ripple, even shot noise, etc., lead to multiple sidebands forming a quasi-continuous noise spectrum at the carrier frequency. Therefore, in the traditionally used mode of operation and control, such magnetrons are inapplicable for powering high Q-factor SRF cavities. A new approach to operation and control of CW magnetrons considering non-stationary processes during start-up and operation makes it possible to find a mode of almost coherent RF generation of tubes with a significant reduction in regenerative instability and noise and increased efficiency. In our work is presented substantiation for the newly developed mode with an analysis of the new approach based on experimental results. •In this article, for the first time, non-stationary, regenerative processes are considered during the start-up and operation of CW magnetrons for powering high-Q superconducting RF cavities.•An analytical study, confirmed by experiments, showed that the traditionally used modes of starting and operating CW magnetrons are not suitable for powering high-Q superconducting RF cavities.•In fact, to make CW magnetrons suitable for such cavities, the physics of starting and operating CW magnetrons must be changed. This has been demonstrated in our work.•In developing the Stimulated Coherent Generation Mode [NIM A 980 (2020) 164366], we have shown the suitability of this mode for starting and operating CW magnetrons for high-Q superconducting RF cavities.•Analytical analysis, verified experimentally, substantiates in our article the suitability of the “Mode of stimulated coherent generation” of CW magnetrons for powering high-Q superconducting cavities in pulsed and continuous modes.

43 PARTICLE ACCELERATORS↗

RF Conditioning of the Photo-Cathode RF Gun at the Advanced Photon Source - NWA RF Measurements

A new S-band Photo-cathode (PC) gun was recently installed and RF conditioned at the Advanced Photon Source (APS) Injector Test-stand (ITS) at Argonne National Lab (ANL). The APS PC gun is a LCLS type gun fabricated at SLAC [1]. The PC gun was delivered to the APS in October 2013 and installed in the APS ITS in December 2013. At ANL, we developed a new method of fast detection and mitigation of the guns internal arcs during the RF conditioning process to protect the gun from arc damage and to RF condition more efficiently. Here, we report the results of RF measurements for the PC gun and an Auto-Restart method for high power RF conditioning.

Smith, T. L.↗

Analysis of TID process, geometry, and bias condition dependence in 14-nm FinFETs and implications for RF and SRAM performance

Here, total ionizing dose results are provided, showing the effects of different threshold adjust implant processes and irradiation bias conditions of 14-nm FinFETs. Minimal radiation-induced threshold voltage shift across a variety of transistor types is observed. Off-state leakage current of nMOSFET transistors exhibits a strong gate bias dependence, indicating electrostatic gate control of the sub-fin region and the corresponding parasitic conduction path are the largest concern for radiation hardness in FinFET technology. The high-Vth transistors exhibit the best irradiation performance across all bias conditions, showing a reasonably small change in off-state leakage current and Vth, while the low-Vth transistors exhibit a larger change in off-state leakage current. The “worst-case” bias condition during irradiation for both pull-down and pass-gate nMOSFETs in static random access memory is determined to be the on-state (Vgs = Vdd). We find the nMOSFET pull-down and pass-gate transistors of the SRAM bit-cell show less radiation-induced degradation due to transistor geometry and channel doping differences than the low-Vth transistor. Near-threshold operation is presented as a methodology for reducing radiation-induced increases in off-state device leakage current. In a 14-nm FinFET technology, the modeling indicates devices with high channel stop doping show the most robust response to TID allowing stable operation of ring oscillators and the SRAM bit-cell with minimal shift in critical operating characteristics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An RF dosimeter for independent SAR measurement in MRI scanners

Purpose: The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI scanners can overestimate specific absorption rates (SAR) and improperly restrict clinical MRI scans or the application of new MRI sequences, while underestimation of SAR can lead to tissue heating and thermal injury. Accurate scanner-independent RF dosimetry is essential for measuring actual exposure when SAR is critical for ensuring regulatory compliance and MRI safety, for establishing RF exposure while evaluating interventional leads and devices, and for routine MRI quality assessment by medical physicists. However, at present there are no scanner-independent SAR dosimeters. Methods: An SAR dosimeter with an RF transducer comprises two orthogonal, rectangular copper loops and a spherical MRI phantom. The transducer is placed in the magnet bore and calibrated to approximate the resistive loading of the scanner's whole-body birdcage RF coil for human subjects in Philips, GE and Siemens 3 tesla (3T) MRI scanners. The transducer loop reactances are adjusted to minimize interference with the transmit RF field (B{sub 1}) at the MRI frequency. Power from the RF transducer is sampled with a high dynamic range power monitor and recorded on a computer. The deposited power is calibrated and tested on eight different MRI scanners. Whole-body absorbed power vs weight and body mass index (BMI) is measured directly on 26 subjects. Results: A single linear calibration curve sufficed for RF dosimetry at 127.8 MHz on three different Philips and three GE 3T MRI scanners. An RF dosimeter operating at 123.2 MHz on two Siemens 3T scanners required a separate transducer and a slightly different calibration curve. Measurement accuracy was ∼3%. With the torso landmarked at the xiphoid, human adult whole‑body absorbed power varied approximately linearly with patient weight and BMI. This indicates that whole-body torso SAR is on average independent of the imaging subject, albeit with fluctuations. Conclusions: Our 3T RF dosimeter and transducers accurately measure RF exposure in body-equivalent loads and provide scanner-independent assessments of whole-body RF power deposition for establishing safety compliance useful for MRI sequence and device testing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ion extraction from a saddle antenna RF surface plasma source

Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H{sup +} and H{sup −} ion generation around 3 to 5 mA/cm{sup 2} per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H{sup −} ion production efficiency and SPS reliability and availability. At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm{sup 2} per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power ∼1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with ∼4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H{sup −} beam without intensity degradation was demonstrated in the AlN discharge chamber for a long time at high discharge power in an RF SPS with an external antenna. Continuous wave (CW) operation of the SA SPS has been tested on the small test stand. The general design of the CW SA SPS is based on the pulsed version. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. CW operation with negative ion extraction was tested with RF power up to 1.8 kW from the generator (∼1.2 kW in the plasma) with production up to Ic=7 mA. Long term operation was tested with 1.2 kW from the RF generator (∼0.8 kW in the plasma) with production of Ic=5 mA, Iex ∼15 mA (Uex=8 kV, Uc=14 kV)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical properties of RF magnetron sputtered GaN/n-Si thin film: impacts of RF power

GaN thin film was successfully produced on n-Si(100) substrate by RF magnetron sputter under different RF power. Experimental measurement techniques such as UV/Vis spectroscopy, field emission scanning electron microscopy (FE-SEM), X-ray diffraction (XRD), atomic force microscopy (AFM), and Micro-Raman Spectroscopy were used to research effects of Radio Frequency power on physical properties of produced thin film. It has been found that produced thin film was polycrystalline structure with (100) and (110) planes of hexagonal GaN from X-ray diffraction measurement result. It also proved that increasing RF power gives rise to deterioration in crystal quality of GaN thin film. Reason of this deterioration was discussed. It has been achieved that increasing RF power has resulted in decreasing optical band gap energy of GaN thin film. Reasons for these changes in optical band gap energy were explained. It was seen that some thin films were grown as layer-plus-island mode (Stranski–Krastanov growth mode) and others were grown as layer-by-layer growth mode (Frank van der Merwe mode) from AFM analysis. It has been found that increasing RF power has resulted in improvement of surface morphology of thin film from field emission scanning electron microscopy analysis. However, reaching RF power to 125 W leads to start to deteriorate of surface of GaN thin film. The reasons for this have been discussed. E{sub 1}(TO) transverse optical phonon mode of hexagonal GaN with different intensity was detected from Micro-Raman Spectroscopy measurement. The reasons for this difference have been discussed. It was concluded that RF power has played a significant role in growing high quality GaN thin film. Morphological, structural, and optical properties of GaN thin film were enhanced by controlling RF power, making them a potential candidate for LED, solar cell, diode application.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Analyzing Single Giant Unilamellar Vesicles With a Slotline-Based RF Nanometer Sensor

Novel techniques that enable reagent free detection and analysis of single cells are of great interest for the development of biological and medical sciences as well as point-of-care health service technologies. Highly sensitive and broadband radio-frequency (RF) sensors are promising candidates for such a technique. In this work, we present a highly sensitive and tunable RF sensor, which is based on interference processes and built with a 100 nm slotline structure. The highly concentrated RF fields, up to ~1.76×107 V/m, enable strong interactions between Giant unilamellar vesicles (GUVs) and fields for high sensitivity operations. We also provide two modeling approaches to extract cell dielectric properties from measured scattering parameters. GUVs of different molecular compositions are synthesized and analyzed with the RF sensor at ~2 GHz, ~2.5 GHz, and ~2.8 GHz with an initial |S21|min of ~-100 dB. Corresponding GUV dielectric properties are obtained. A one-dimensional scanning of single GUV is also demonstrated.

Cui, Yan↗

Modeling of standing wave RF cavities for tracking through multi-pass energy recovery linac

Short bunches, high current and multiple linac pass are all characteristics of Energy Recovery Linacs (ERLs), which may result in collective effects. They in turn, may affect the beam, degrading its quality, or even yield to instabilities causing a beam loss. To study and mitigate these effects one needs a numerical simulation code, that can take into account both the collective effects, as well as, particular ERL features, such as a multi-turn design that does not reach a steady state or the multiple passages of the beam through Radio-Frequency (RF) cavities at different energies. CODAL [1], a code developed by SOLEIL in collaboration with IJCLab, enables such studies. It is a 6 dimensional (6D) tracking code applying 'kicks' based on the integration of the local Hamiltonian for each element of the lattice. It is also capable of simulating space charge, wakefields and coherent synchrotron radiation. However, to correctly take into account the ERL dynamics, an upgrade had to be made to include the effect of a standing wave RF cavity in 6D. In this paper, we will concentrate on the implementation and benchmarking (with DESY’s tracking code ASTRA [2]) of both the longitudinal and the transverse models (by J.B. Rosenzweig and L. Serafini [3]), which we use to carry out tracking of fully analytical 6D RF cavity.

Bogacz, A.↗

Fast-RF-Shimming: Accelerate RF shimming in 7T MRI using deep learning

Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) offers an elevated signal-to-noise ratio (SNR), enabling exceptionally high spatial resolution that benefits both clinical diagnostics and advanced research. However, the jump to higher fields introduces complications, particularly transmit radiofrequency (RF) field ($B^{+}_{1}$) inhomogeneities, manifesting as uneven flip angles and image intensity irregularities. These artifacts can degrade image quality and impede broader clinical adoption. Traditional RF shimming methods, such as Magnitude Least Squares (MLS) optimization, effectively mitigate $B^{+}_{1}$ inhomogeneity, but remain time-consuming. Recent machine learning approaches, including RF Shim Prediction by Iteratively Projected Ridge Regression and other deep learning architectures, suggest alternative pathways. Although these approaches show promise, challenges such as extensive training periods, limited network complexity, and practical data requirements persist. In this paper, we introduce a holistic learning-based framework called Fast-RF-Shimming, which achieves a 5000 ​× ​speed-up compared to the traditional MLS method. In the initial phase, we employ random-initialized Adaptive Moment Estimation (Adam) to derive the desired reference shimming weights from multi-channel $B^{+}_{1}$ fields. Next, we train a Residual Network (ResNet) to map $B^{+}_{1}$ fields directly to the ultimate RF shimming outputs, incorporating the confidence parameter into its loss function. Finally, we design Non-uniformity Field Detector (NFD), an optional post-processing step, to ensure the extreme non-uniform outcomes are identified. Comparative evaluations with standard MLS optimization underscore notable gains in both processing speed and predictive accuracy, which indicates that our technique shows a promising solution for addressing persistent inhomogeneity challenges.

Deep learning↗

Imaging collective behavior in an rf-SQUID metamaterial tuned by DC and RF magnetic fields

In this study, we examine the collective behavior of two-dimensional nonlinear superconducting metamaterials using a non-contact spatially resolved imaging technique. The metamaterial is made up of sub-wavelength nonlinear oscillators in a strongly coupled 27x27 planar array of radio-frequency Superconducting QUantum Interference Devices (rf SQUIDs). By using low-temperature laser scanning microscopy we image microwave currents in the driven SQUIDs while in non-radiating dark modes and identify the clustering and uniformity of like-oscillating meta-atoms. We follow the rearrangement of coherent patterns due to meta-atom resonant frequency tuning as a function of external dc and rf magnetic flux bias. We find that the rf current distribution across the SQUID array at zero dc flux and small rf flux reveals a low degree of coherence. By contrast, the spatial coherence improves dramatically upon increasing of rf flux amplitude, in agreement with simulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of RF Sheath-Driven Tungsten Erosion at RF Antenna in the WEST Tokamak

This study applies the newly developed STRIPE (Simulated Transport of RF Impurity Production and Emission) framework to analyze tungsten (W) erosion at RF antenna structures in the WEST tokamak. STRIPE integrates SolEdge3x for edge plasma backgrounds, COMSOL for 3D RF sheath potentials, RustBCA for sputtering yields, and GITR for impurity transport and ion energy–angle distributions. Building on prior work by Kumar et al. (2025) Nuclear Fusion, 65, 076039, which validated STRIPE for WEST ICRH discharge #57877, the present study provides a spatially resolved assessment of gross W erosion at both Q2 antenna limiters under ohmic and ICRH conditions. Simulations using 2D SolEdge3x profiles in COMSOL capture rectified sheath potentials exceeding 300 V, leading to strong upper-limiter localization. Both poloidal and toroidal asymmetries are observed and attributed to RF sheath effects, with modeled erosion patterns deviating from experiment—highlighting sensitivity to sheath geometry and plasma resolution. Erosion is driven primarily by high-charge-state oxygen ions (O6+–O8+), while D+ plays a negligible role. Assuming a plasma composition of 1% oxygen and 98% deuterium, STRIPE predicts a 30-fold increase in gross W erosion from ohmic to ICRH phases, consistent with a >25-fold rise in W-I (400.9 nm) brightness. Quantitative agreement is within 5% in the ohmic phase and 30% under ICRH, demonstrating predictive capability. Importantly, the study shows that the magnitude of ICRH-driven W erosion depends strongly on the concentration of light impurities (O, B, N, C), which drive sputtering through high charge states. Cleaner plasma conditions with reduced impurity content are therefore expected to substantially mitigate antenna W sources in WEST and other toroidal fusion devices. These findings establish STRIPE as a predictive framework for RF-induced plasma–material interactions and support its application to reactor-scale antenna design.

Kumar, Atul [ORNL] (ORCID:0000000277475210)↗

RF synchronized short pulse laser ion source

A laser ion source that produces shortly bunched ion beam is proposed. In this ion source, ions are extracted immediately after the generation of laser plasma by an ultra-short pulse laser before its diffusion. The ions can be injected into radio frequency (RF) accelerating bucket of a subsequent accelerator. As a proof-of-principle experiment of the ion source, a RF resonator is prepared and H{sub 2} gas was ionized by a short pulse laser in the RF electric field in the resonator. As a result, bunched ions with 1.2 mA peak current and 5 ns pulse length were observed at the exit of RF resonator by a probe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FEbeam: Cavity and electron emission data conversion, processing, and analysis. A freeware toolkit for rf injectors

FEbeam is an all-in-one field emission data processing interface with the capability to analyze the field emission cathode performance in an rf injector by extracting the field enhancement factor, local field, and effective emission area from the Fowler–Nordheim equations. It also has the capability of processing beam imaging micrographs using its sister software, FEpic. Furthermore, the current version of FEbeam was designed for the Argonne Cathode Test-stand of the Argonne Wakefield Accelerator facility switch yard. With slight modifications, FEbeam could work for many rf field emission injectors. This software is open-source and can be found at GitHub.

43 PARTICLE ACCELERATORS↗

RF sheath induced sputtering on Proto-MPEX. I. Sheath equivalent dielectric layer for modeling the RF sheath

The pulsed linear plasma device Prototype Material Plasma Exposure eXperiment (Proto-MPEX) uses a radio frequency (RF) helicon antenna with an aluminum nitride ceramic window for plasma production. The RF sheath created under the helicon antenna is sufficient to cause ion impact energies to be greater than the sputtering threshold of the AlN helicon window material and for impurities to be created. In this study, we investigate the RF sheath on the inner diameter of the helicon window and its impact on the impurity production rates in Proto-MPEX. Three models—a 3D COMSOL finite element RF model of the Proto-MPEX helicon region, a rectified DC sheath potential model, and the 3D Global Impurity TRansport code—are coupled together to study impurity production and transportation. This novel method of impurity generation and transport modeling spans length scales ranging from the sheath (millimeters or less) up to the full device (meters) and can be applied to other radio frequency sources and antennas in a wide range of plasma physics studies, including basic plasmas, low-temperature processing plasmas, plasma thrusters, and fusion plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of RF losses and material characterization of samples removed from a Nb 3 Sn-coated superconducting RF cavity

Nb 3 Sn (T c ≈18 K and H sh ≈400 mT) is a prospective material to replace Nb (T c ≈9 K and H sh ≈200 mT) in SRF accelerator cavities for significant cost reduction and performance enhancement. Because of its material properties, Nb3Sn is best employed as a thin film (coating) inside an already built RF cavity structure. A particular test cavity noted as C3C4 was a 1.5 GHz single-cell Nb cavity, coated with Nb3Sn using Sn vapor diffusion process at Jefferson Lab. Cold measurements of the coated cavity indicated the superconducting transition temperature of about 18 K. Subsequent RF measurements indicated field-dependent surface resistance both at 4.3 K and 2.0 K. After initial cold measurements, the cavity RF loss distribution was studied with a thermometry mapping system. Loss regions were identified with thermometry and were cut out for material analysis. The presence of significantly thin patchy regions and other carbon-rich defects is associated with strong local field-dependent surface resistance. This paper summarizes RF and thermometry results correlated with material science findings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

RF Accelerator Technology R&D: Report of AF7-rf Topical Group to Snowmass 2021

Accelerator radio frequency (RF) technology has been and remains critical for modern high energy physics (HEP) experiments based on particle accelerators. Tremendous progress in advancing this technology has been achieved over the past decade in several areas highlighted in this report. These achievements and new results expected from continued R&D efforts could pave the way for upgrades of existing facilities, improvements to accelerators already under construction (e.g., PIP-II), well-developed proposals (e.g., ILC, CLIC), and/or enable concepts under development, such as FCC-ee, CEPC, C 3 , HELEN, multi-MW Fermilab Proton Intensity Upgrade, future Muon Colloder, etc. Advances in RF technology have impact beyond HEP on accelerators built for nuclear physics, basic energy sciences, and other areas. Recent examples of such accelerators are European XFEL, LCLS-II and LCLS-II-HE, SHINE, SNS, ESS, FRIB, and EIC. To support and enable new accelerator-based applications and even make some of them feasible, we must continue addressing their challenges via a comprehensive RF R&D program that would advance the existing RF technologies and explore the nascent ones.

43 PARTICLE ACCELERATORS↗

Dependence of beam emittance on plasma electrode temperature and rf-power, and filter-field tuning with center-gapped rod-filter magnets in J-PARC rf-driven H{sup −} ion source

The prototype rf-driven H{sup −} ion-source with a nickel plated oxygen-free-copper (OFC) plasma chamber, which satisfies the Japan Proton Accelerator Research Complex (J-PARC) 2nd stage requirements of a H{sup −} ion beam current of 60 mA within normalized emittances of 1.5 π mm mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500 μs × 25 Hz) and a life-time of more than 50 days, was reported at the 3rd international symposium on negative ions, beams, and sources (NIBS2012). The experimental results of the J-PARC ion source with a plasma chamber made of stainless-steel, instead of nickel plated OFC used in the prototype source, are presented in this paper. By comparing these two sources, the following two important results were acquired. One was that the about 20% lower emittance was produced by the rather low plasma electrode (PE) temperature (T{sub PE}) of about 120 °C compared with the typically used T{sub PE} of about 200 °C to maximize the beam current for the plasma with the abundant cesium (Cs). The other was that by using the rod-filter magnets with a gap at each center and tuning the gap-lengths, the filter-field was optimized and the rf-power necessary to produce the J-PARC required H{sup −} ion beam current was reduced typically 18%. The lower rf-power also decreases the emittances.

43 PARTICLE ACCELERATORS↗