Atomic response function.
Response functions of atoms, excited in external field of given frequency and of wavelength larger than atomic dimensions
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Response functions of atoms, excited in external field of given frequency and of wavelength larger than atomic dimensions
Not Available
Here, we present calculations of the 40 Ca transverse response function obtained from coupled-cluster theory used in conjunction with the Lorentz integral transform method. We employ nuclear forces derived at next-to-next-to leading order in chiral effective field theory with and without Δ degrees of freedom. We first benchmark this approach on the 4 He nucleus and compare both the transverse sum rule and the response function to earlier calculations based on different methods. As expected from the power counting of the chiral expansion of electromagnetic currents and from previous studies, our results retaining only one-body term underestimate the experimental data for 4 He by about 20%. However, when the method is applied to 40 Ca at the same order of the expansion, response functions do not lack strength and agree well with the world electron scattering data. We discuss various sources of theoretical uncertainties and comment on the comparison of our results with the available experiments.
The one-dimensional imager of neutrons (ODIN) at the Sandia Z facility consists of a 10-cm block of tungsten with rolled edges, creating a slit imager with slit widths of either 250, 500, or 750 μm. Designed with a 1-m neutron imaging line of sight, we achieve about 4:1 magnification and 500-μm axial spatial resolution. The baseline inertial confinement fusion concept at Sandia is magnetized liner inertial fusion, which nominally creates a 1-cm line source of neutrons. ODIN was designed to determine the size, shape, and location of the neutron producing region, furthering the understanding of compression quality along the cylindrical axis of magnetized liner implosions. Challenges include discriminating neutrons from hard x-rays and gammas with adequate signal-to-noise in the 2 × 10 12 deuterium-deuterium (DD) neutron yield range, as well as understanding the point spread function of the imager to various imaging detectors (namely, CR-39). Modeling efforts were conducted with MCNP6.1 to determine neutron response functions for varying configurations in a clean DD neutron environment (without x-rays or gammas). Configuration alterations that will be shown include rolled-edge slit orientation and slit width, affecting the resolution and response function. The experiment to determine CR-39 neutron sensitivity, with and without a high density polyethylene (n, p) converter, an edge spread function, and resolution will be discussed.
Not provided.
A major goal of nuclear theory is to understand the strong interaction in nuclei as it manifests itself in terms of two- and many-body forces among the nuclear constituents, the protons and neutrons, and the interactions of these constituents with external electroweak probes via one- and many-body currents. The objective of the present work is to calculate the quasielastic electroweak response functions in light nuclei within the realistic dynamical framework outlined above. These response functions determine the inclusive cross section as function of the lepton momentum and energy transfers. Their ab initio calculation is a very challenging quantum many-body problem, since it requires summation over the entire excitation spectrum of the nucleus and inclusion in the electroweak currents of one- and many-body terms. Green's functions Monte Carlo methods allow one to circumvent both difficulties by computing the response in imaginary time (the so-called Euclidean response) and hence summing implicitly over the bound and continuum states of the nucleus, and by implementing specific algorithms designed to deal with the complicated spin-isospin structure of nuclear many-body operators. Theoretical predictions for 4 He and 12 C, confirmed by experiment in the electromagnetic case, show that two-body currents generate excess transverse strength from threshold to the quasielastic to the dip region and beyond. In conclusion, these results challenge the conventional picture of quasielastic inclusive scattering as being largely dominated by single-nucleon knockout processes.
Background: Measurements of forward exclusive meson production at different squared four-momenta of the exchanged virtual photon, Q 2 , and at different four-momentum transfer, t, can be used to probe QCD's transition from meson-nucleon degrees of freedom at long distances to quark-gluon degrees of freedom at short scales. Ratios of separated response functions in π⁻ and π⁺ electroproduction are particularly informative. Ratio for transverse photons may allow this transition to be more easily observed, while the ratio for longitudinal photons provides a crucial verification of the assumed pole dominance, needed for reliable extraction of the pion form factor from electroproduction data. Method: Data were acquired with 2.6-5.2 GeV electron beams and the HMS+SOS spectrometers in Jefferson Lab Hall C, at central Q 2 values of 0.6, 1.0, 1.6 GeV 2 at W=1.95 GeV, and Q 2 =2.45 GeV 2 at W=2.22 GeV. There was significant coverage in Φ And ϵ, which allowed separation of σ L,T,LT,TT . Results: σL shows a clear signature of the pion pole, with a sharp rise at small -t. In contrast, σ T is much flatter versus t. The longitudinal/transverse ratios evolve with Q 2 and t, and at the highest Q 2 =2.45 GeV 2 show a slight enhancement for π⁻ Production compared to π⁺. The π⁻/π⁺+ ratio for transverse photons exhibits only a small Q 2 -dependence, following a nearly universal curve with t, with a steep transition to a value of about 0.25, consistent with s-channel quark knockout. The σ TT /σ T ratio also drops rapidly with Q 2 , qualitatively consistent with s-channel helicity conservation. The π⁻/π⁺ ratio for longitudinal photons indicates a small isoscalar contamination at W=1.95 GeV, consistent with what was observed in our earlier determination of the pion form factor at these kinematics.
We apply the linear response function method to investigate the most excitable mode of the September Arctic sea ice and its corresponding remote oceanic forcing in climate models. The method is useful in identifying the fundamental, dynamical and causal relationship between the remote forcing and sea ice response. We find that the most excitable mode of the September Arctic sea ice preferentially takes place over the Pacic side of the Arctic and its remote forcing corresponds to a dipole pattern of precipitation anomaly in the tropics with an increase of precipitation over the western and central tropical and subtropical Pacic ocean while a decrease over the Maritime Continent. The tropical precipitation anomaly likely drives a Rossby wave train propagating toward higher latitudes and leads to a ridge anomaly over the Pacic side of the Arctic, resulting in poleward atmospheric heat transport, enhanced downward longwave radiation and thus melting of the sea ice. In addition, a good agreement is found with the leading tropical Arctic teleconnection mode detected in a pre-industrial control simulation, which supports the usefulness and robustness of the linear response function method and the importance of tropical forcing in shaping the sea ice variability.
The Fermi Large Area Telescope (Fermi-LAT, hereafter LAT), the primary instrument on the Fermi Gamma-ray Space Telescope (Fermi) mission, is an imaging, wide field-of-view, high-energy {gamma}-ray telescope, covering the energy range from 20 MeV to more than 300 GeV. During the first years of the mission, the LAT team has gained considerable insight into the in-flight performance of the instrument. Accordingly, we have updated the analysis used to reduce LAT data for public release as well as the instrument response functions (IRFs), the description of the instrument performance provided for data analysis. In this paper, we describe the effects that motivated these updates. Furthermore, we discuss how we originally derived IRFs from Monte Carlo simulations and later corrected those IRFs for discrepancies observed between flight and simulated data. We also give details of the validations performed using flight data and quantify the residual uncertainties in the IRFs. Finally, we describe techniques the LAT team has developed to propagate those uncertainties into estimates of the systematic errors on common measurements such as fluxes and spectra of astrophysical sources.
Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF’s constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Monte Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF representation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45–65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk measurements, computed DRF responses tended to significantly underestimate (more than 20%) the secondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the statistical uncertainties were lower than their experimental counterpart’s Poisson uncertainties. The uncertainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.
Semiclassical approximations to response functions can allow the calculation of linear and nonlinear spectroscopic observables from classical dynamics. Evaluating a canonical response function requires the related tasks of determining thermal weights for initial states and computing the dynamics of these states. A class of approximations for vibrational response functions employs classical trajectories at quantized values of action variables and represents the effects of the radiation-matter interaction by discontinuous transitions. Here, we evaluate choices for a thermal weight function which are consistent with this dynamical approximation. Weight functions associated with different semiclassical approximations are compared, and two forms are constructed which yield the correct linear response function for a harmonic potential at any temperature and are also correct for anharmonic potentials in the classical mechanical limit of high temperature. Approximations to the vibrational linear response function with quantized classical trajectories and proposed thermal weight functions are assessed for ensembles of one-dimensional anharmonic oscillators. This approach is shown to perform well for an anharmonic potential that is not locally harmonic over a temperature range encompassing the quantum limit of a two-level system and the limit of classical dynamics.
Explore the source record for details and available documents.
The apparent ion temperature and neutron-reaction history are important characteristics of a fusion plasma. Extracting these quantities from a measured neutron-time-of-flight signal requires accurate knowledge of the instrument response function (IRF). This paper describes a novel method for obtaining the IRF directly for single DT neutron interactions by utilizing n-alpha coincidence. The t(d,α)n nuclear reaction was produced at Sandia National Laboratories’ Ion Beam Laboratory using a 300 keV Cockcroft-Walton generator to accelerate a 2.5 μA beam of 175 keV D + ions into a stationary ErT 2 target. The average neutron IRF was calculated by taking a time-corrected average of individual neutron events within an EJ-228 plastic scintillator. The scintillator was coupled to two independent photo-multiplier tubes operated in the current mode: a Hamamatsu 5946 mod-5 and a Photek PMT240. Finally, the experimental setup and results will be discussed.
Explore the source record for details and available documents.
Not Available
This paper explores the use of the linear response function (LRF) to relate the mean sea surface temperature (SST) response to prescribed ocean heat convergence ( q flux) forcings. Two methods for constructing the LRF based on the fluctuation–dissipation theorem (FDT) and Green’s function (GRF) are examined. A 900-yr preindustrial simulation by the Community Earth System Model coupled with a slab ocean model (CESM–SOM) is used to estimate the LRF using FDT. For GRF, 106 pairs of CESM–SOM simulations with warm and cold q-flux patches are performed. FDT is found to have some skill in estimating the SST response to a q-flux forcing when the local SST response is strong, but it fails in inverse estimation of the q-flux forcing for a given SST pattern. In contrast, GRF is shown to be reasonably accurate in estimating both SST response and q-flux forcing. Possible degradation in FDT may be attributed to insufficient data sampling, significant departure of the SST distribution from Gaussianity, and the nonnormality of the constructed operator. The GRF-based LRF is then used to (i) generate a global surface temperature sensitivity map that shows the q-flux forcing in higher latitudes to be 3–4 times more effective than low latitudes in producing global surface warming, and (ii) identify the most excitable SST mode (neutral vector) that shows marked resemblance to the interdecadal Pacific oscillation (IPO). The latter discovery suggests that the IPO-like fluctuation exists in the absence of the coupling to the ocean dynamics. Coupling to the ocean dynamics in CESM, on the other hand, only enhances the spectral power of the IPO at interannual time scales.
Abstract not provided.
Radiochromic films (RCF) are commonly used in dosimetry for a wide range of radiation sources (electrons, protons, and photons) for medical, industrial, and scientific applications. They are multi-layered, which includes plastic substrate layers and sensitive layers that incorporate a radiation-sensitive dye. Quantitative dose can be retrieved by digitizing the film, provided that a prior calibration exists. Here, to calibrate the newly developed EBT3 and HDv2 RCFs from Gafchromic™, we used the Stanford Medical LINAC to deposit in the films various doses of 10 MeV photons, and by scanning the films using three independent EPSON Precision 2450 scanners, three independent EPSON V750 scanners, and two independent EPSON 11000XL scanners. The films were scanned in separate RGB channels, as well as in black and white, and film orientation was varied. We found that the green channel of the RGB scan and the grayscale channel are in fact quite consistent over the different models of the scanner, although this comes at the cost of a reduction in sensitivity (by a factor ∼2.5 compared to the red channel). To allow any user to extend the absolute calibration reported here to any other scanner, we furthermore provide a calibration curve of the EPSON 2450 scanner based on absolutely calibrated, commercially available, optical density filters.