Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESONANT FREQUENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

ESTIMATION OF THE WAKEFIELD RESONANT FREQUENCY USING DIFFERENT SIMULATION TOOLS

Reliable and fast wakefield calculations are important for beam dynamics and THz generation in accelerators. We compare approaches and limitations with different available simulation tools and compare results. As an example, we analyse a cylindrical corrugated waveguide with narrower and wider radii of 5 and 6 mm, and aperture width and periodicity of 1 and 2 mm using ABCI by KEK and ANSYS HFSS simulation software. First, ABCI was used to determine the resonant frequency of the cylindri-cal corrugated waveguide with different lengths. The corresponding results were taken as a reference to exam-ine the simulation method in the ANSYS HFSS environ-ment. The eigenmode solver of ANSYS HFSS was used to determine different resonant frequencies. This was fol-lowed by examining a cylindrical corrugated waveguide that was implemented having a length of 17 mm for dif-ferent conductor settings. The corresponding waveguide was fed by a plane wave having a resonant frequency that satisfies the intersection of the light line and dispersion curve of the corresponding mode. The analysis showed that the maximum loss factor was achieved at 39.20 and 40.07 GHz using ANSYS HFSS simulation data for differ-ent conductors, whereas ABCI resulted in 38.50 GHz. The talk will present the results gathered by different simula-tion setups implemented in ANSYS HFSS.

Unutmaz, Muhammed [SLAC National Accelerator Labor↗

Catalytic Resonance Theory: Turnover Efficiency and the Resonance Frequency

Programmable catalysts exhibiting forced oscillation in the free energy of reacting surface species were simulated to understand the general mechanisms leading to efficient use of the input energy. Catalytic ratchets with either positive or negative adsorbate scaling exhibited oscillation conditions of both high and low turnover efficiency, yielding catalytic turnover frequencies either close to or significantly lower than the applied catalyst oscillation frequency, respectively. The “effective rate”, defined as the product of the catalytic turnover frequency and the turnover efficiency (ηTOE), was limited via two catalytic mechanisms: a leaky catalytic ratchet existed when molecules repeatedly traversed backward through the catalytic transition state upon catalyst oscillation, while a catalytic ratchet with low surface participation exhibited reduced formation of a gas-phase final product due to low surface product coverage. Furthermore, a single applied frequency yielding a maximum effective catalytic rate defined as the “resonance frequency” provided maximum combined benefit for catalytic rate and efficiency.

25 ENERGY STORAGE↗

Improved Calculation of the Young’s Modulus of Rectangular Prisms from Their Resonant Frequency Overtones by Identifying Appropriate Shear Constants

Young’s modulus is an important parameter for characterizing the strength of, and wave propagation through, a given material. This study improves the estimation of Young’s modulus using the impulse excitation technique based on an experimental analysis of 19 borosilicate glass bars. Analysis of the frequency equations relating Young’s modulus to the out-of-plane and in-plane flexural resonant frequencies of rectangular prisms has been conducted for both the fundamental frequency and its overtones at higher orders of vibration. Furthermore, the Young’s moduli of three novaculite rocks with various porosities were then measured up to the seventh order of vibration to validate the optimum shear constant equation for estimating Young’s modulus. Young’s modulus was found to be nearly frequency independent for these rock samples.

Impulse excitation↗

A high-frequency, low-power resonant radio-frequency neutron spin flipper for high-resolution spectroscopy

Here, we present a resonant-mode, transverse-field, radio-frequency (rf) neutron spin flipper design that uses high-temperature superconducting films to ensure sharp transitions between uniform magnetic field regions. Resonant mode allows for low-power, high-frequency operation but requires strict homogeneity of the magnetic fields inside the device. This design was found to efficiently flip neutrons at 96.6 ± 0.6% at an effective frequency of 4 MHz in bootstrap configuration with a beam size of 2.4 × 2.5 cm 2 and a wavelength of 0.4 nm. The high frequency and efficiency enable this device to perform high-resolution neutron spectroscopy with comparable performance with currently implemented rf flipper designs. The limitation of the maximum frequency was found due to the field homogeneity of the device. We numerically analyze the maximum possible efficiency of this design using a Bloch solver simulation with magnetic fields generated from finite-element simulations. We also discuss future improvements of the efficiency and frequency to the design based on the experimental and simulation results.

47 OTHER INSTRUMENTATION↗

Development of an MKID frequency-to-pixel LED mapper for SPT-3G+

SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding the Phase of Responsivity and Noise Sources in Frequency-Domain Multiplexed Readout of Transition Edge Sensor Bolometers

Abstract Cosmic microwave background (CMB) experiments have deployed focal planes with $$\mathcal {O}(10^{4})$$ O ( 10 4 ) transition edge sensor (TES) bolometers cooled to sub-Kelvin temperatures by multiplexing the readout of many TES channels onto a single pair of wires. Digital Frequency-domain Multiplexing (DfMux) is a multiplexing technique used in many CMB polarization experiments, such as the Simons Array, SPT-3 G, and EBEX. The DfMux system studied here uses LC filters with resonant frequencies ranging from 1.5 to 4.5 MHz connected to an array of TESs. Each detector has an amplitude-modulated carrier tone at the resonant frequency of its accompanying LC resonator. The signal is recovered via quadrature demodulation where the in-phase (I) component of the demodulated current is in phase with the complex admittance of the circuit and the quadrature (Q) component is orthogonal to I. Observed excess current noise in the Q component is consistent with fluctuations in the resonant frequency. This noise has been shown to be non-orthogonal to the phase of the detector’s responsivity. We present a detailed analysis of the phase of responsivity of the TES and noise sources in our DfMux readout system. Further, we investigate how modifications to the TES operating resistance and bias frequency can affect the phase of noise relative to the phase of the detector responsivity, using data from Simons Array to evaluate our predictions. We find that both the phase of responsivity and phase of noise are functions of the two tuning parameters, which can be purposefully selected to maximize signal-to-noise (SNR) ratio.

47 OTHER INSTRUMENTATION↗

Significant acceleration of solid-state NMR simulations via three-angle powder averaging

The anisotropic frequency shifts imparted onto the NMR resonance frequency depend on the spherical angular coordinates that describe the orientations of the NMR interaction tensors with respect to the applied magnetic field direction. Experiments performed using magic-angle spinning, however, gain a dependence on a third angle: the rotor phase γ. Traditionally, a carousel average is performed to integrate over γ, which leads to a slow convergence of intensities without contributing to the underlying powder patterns. Herein, we show an order of magnitude acceleration in computation time may be obtained by including the γ-averaging into the main powder average to eliminate redundant calculation of resonance frequencies.

magic-angle spinning↗

Frequency shifts in the electron paramagnetic resonance spectrum of 39 K due to spin-exchange collisions with polarized 3 He and precise 3 He polarimetry

The Zeeman splittings and electron paramagnetic resonance frequencies of alkali-metal atoms are shifted in the presence of a polarized noble gas. For a spherical geometry, the shift is enhanced over what is expected classically by a dimensionless atomic parameter 𝜅 0 that is unique to each alkali-metal-atom–noble-gas pair. Here, we present a precise measurement of 𝜅 0 for the 39 K − 3 He system with a relative accuracy of better than 1%. A critical component of achieving subpercent accuracy involved characterizing the shape of our samples using both MRI and CT medical-imaging techniques. The parameter 𝜅 0 plays an important role in establishing the absolute polarization of 3 He in a variety of contexts, including polarized targets for electron-scattering experiments and MRI of the gas space of the lungs. Our measurement more than doubles the accuracy possible when using 𝜅 0 for polarimetry purposes. Just as important, the work presented here represents a direct measurement of 𝜅 0 for the 39 K − 3 He system; previous values for 𝜅 0 in the 39 K − 3 He system relied on a chain of measurements that were benchmarked by previous measurements of 𝜅 0 in the Rb- 3 He system.

Zeeman effect↗

Laser-Induced Spectral Diffusion of T Centers in Silicon Nanophotonic Devices

Color centers in silicon are emerging as spin-photon interfaces operating at telecommunication wavelengths. The nanophotonic device integration of silicon color centers via ion implantation leads to significant optical-linewidth broadening, which makes indistinguishable photon generation challenging. Here, we study the optical spectral diffusion of T centers in a silicon photonic crystal cavity. We investigate the linewidth-broadening timescales and origins by measuring the temporal correlations of the resonance frequency under different conditions. Spectral hole-burning measurements reveal no spectral broadening at short timescales from 102 ns to 725 ns. We probe broadening at longer timescales using a check pulse to herald the T-center frequency and a probe pulse to measure the frequency after a wait time. The optical resonance frequency is stable up to 3 ms in the dark. Laser pulses below the silicon band gap applied during the wait time lead to linewidth broadening. Our observations establish laser-induced processes as the dominant spectral-diffusion mechanism for T centers in devices and inform materials and feedback strategies for indistinguishable photon generation.

Zhang, Xueyue↗

Comparison of URANS and LES predictions for the open phase of the OECD NEA CSNI fluid structure interaction CFD benchmark

The OECD NEA CSNI WGAMA CFD Task Group ran a benchmark in 2020 and 2021 to assess the predictive capabilities of coupled fluid structure interaction (FSI) CFD analysis methods. This paper presents the predictions made for the open phase of the benchmark using URANS and LES turbulence modelling approaches, and a comparison of the results to the experimental data. The benchmark comprised a channel containing two inline cylinders in cross-flow. The cylinders were fixed at one end, free at the other, and had measured resonant frequencies and damping properties. The URANS modelling used ANSYS Fluent 2-way coupled to ANSYS Mechanical. The LES modelling used Nek5000, 1-way coupled to Diablo. Comparisons with cross-channel velocity profiles are presented, both for the mean flow and its RMS. Comparisons are also made to the frequency spectra for point measurements of fluid velocity and pressure, and for the accelerations of the free end of each cylinder. URANS predicts the average velocity profiles relatively well, and is able to predict the velocity and acceleration spectra at the shedding frequency. However, the frequency content at the 4th harmonic of the shedding frequency is low in the URANS flow fields, and so does not excite accelerations at the resonant frequency of the cylinders. LES makes better predictions of the average profiles, and the velocity spectra agree well at both the shedding frequency and at higher frequencies. In conclusion, the 1-way coupled LES results show good agreement for acceleration spectra.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dielectric Resonator Design for Low Power and Low Temperature Microwave Plasma

Waveguide-based microwave plasmas generally operate at high temperatures (2000 - 6000K)[1], making it difficult to directly interface solid materials with the plasma without significant thermal damage. Dielectric microwave resonators (DMRs), long studied for wave-based manipulation of electromagnetic radiation for telecom and optics, can focus radiation to extremely small mode volumes, creating intense localized fields with low-power input.[2] This phenomenon can be used for applications ranging from efficient plasma electronics to near-ambient plasma-materials interactions. Such DMR-based plasmas have been demonstrated a handful of times in the literature, but the majority of research towards this utilize the lowest frequency resonance mode.[3], [4], [5] By carefully controlling the geometry of cylindrical resonators, a variety of electromagnetic modes can be excited. In this work, COMSOL Multiphysics simulations are used to study the electric field enhancement and absorption properties of CaTiO3 DMRs as a function of geometry and excitation frequency. Whereas previous studies have utilized the HEM111 resonance frequency to drive low power plasma excitation, we find that higher order resonance frequencies are more effective at field enhancement and result in less power loss within the dielectric material, hence less wasted heating. The effectiveness of these modes is also geometry dependent and can be computationally optimized for plasma generation. Complementing these computational efforts, we demonstrate a new closed-system reactor design built in a WR-650 waveguide and experimentally demonstrate the formation of atmospheric argon microwave plasma using < 30 W input power on DMR dimers. We observe a shifting resonance frequency as the DMRs heat in response to microwave excitation and develop a Python-based lock-in mechanism to effectively track the DMR resonance over time, leading to stable plasma operation. We use infrared thermal imaging to monitor the temperature of the DMR dimers and surrounding quartz chamber, demonstrating thermal temperatures < 60 degreesC. Finally, we utilize optical emission spectroscopy (OES) to probe the plasma properties as a function of the resonance mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Strain-tunable microwave-resonance technique for quantum materials

By integrating a dielectric microwave resonator with a piezoelectric-based strain device, we develop an in situ strain-tunable microwave spectroscopy technique that enables contactless measurements of material properties under strain. To demonstrate the capability of this device, we measure the strain-dependent microwave surface impedance of the representative iron-based superconductor Ba⁢Fe 2 (As 1−𝑥 ⁢P 𝑥 ) 2 at the slightly overdoped composition. We successfully control and observe the suppression of superconductivity under both compressive and tensile anisotropic lattice distortions along the tetragonal [110] T direction, as manifested by changes in the quality factor and resonance frequency shifts of microwave resonance. Furthermore, strain-induced changes in microwave surface resistivity, an extension of conventional DC-limit transport elastoresistivity to the microwave regime, provide information on electronic anisotropy equivalent to that of DC elastoresistivity, while offering a contactless alternative. Furthermore, our strain-tunable cavity therefore serves as a powerful, contactless probe of fundamental material properties under strain and may also potentially facilitate the design of hybrid quantum systems with strain-engineered quantum degrees of freedom.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Beehive haloscope for high-mass axion dark matter

We propose a new haloscope geometry that can arbitrarily increase the resonator volume for a given target axion mass. This geometry consists of closely packed, overlapping coaxial cavities operating as a single resonator. While the resonant frequency is still determined by the dimensions of the individual “cells,” the strong interactions between the cells encourage the entire “beehive” to oscillate in phase, a phenomenon expected of tightly coupled harmonic oscillators. This synchronization behavior allows the construction of a singly connected large volume resonator at high frequency by simply increasing the number of the cells. Using direct numerical simulations, we verify the existence of a global eigenmode that has a high (40%) form factor in a 169-element beehive resonator. The resonant frequency of the eigenmode is tunable by moving the center rods laterally in unison. The form factor is very tolerant to dimensional deviations and misalignment as a result of mode hybridization due to strong coupling. The beehive haloscope inherits many appealing properties from the conventional coaxial cavity: a high quality factor, compatibility with a solenoid magnet, and ease of fabrication, tuning, and coupling. We argue that this geometry is an excellent candidate for high-mass axion searches covering the post-inflationary parameter space (>5 GHz).

47 OTHER INSTRUMENTATION↗

Asymmetrical cavity design that bypasses mode mixings in axion haloscope experiments

Microwave cavities used in axion haloscope experiments typically employ a tuning rod as a means to widen the range of resonance frequencies at which it is sensitive to axion-to-photon conversion. A realistic tuning mechanism requires a gap between the cavity end caps and the tuning rod to ensure movement, and causes some modes to hybridize with the resonant mode that is being tracked for the experiment. These so-called mode mixings lead to gaps in the frequency range that practically lose sensitivity to axions. Here, to solve this problem, we present a cavity design which, for two tuning rod configurations corresponding to a lower and higher frequency range, have a dielectric rod inserted at a specific location that makes the cavity asymmetrical. Moving the tuning rod closer to the dielectric insert changes the location and frequency of the mode mixing compared to when it is farther away from it. This design is easily realizable in practical experiments and makes possible an axion dark matter search with minimal loss in sensitivity due to mode mixings. We also show that the same design has the same desired effect when cavity dimensions are scaled down to be smaller and are at higher resonance frequencies.

Axion↗

Modeling frequency instability in high-quality resonant experiments

Modern resonant sensing tools can achieve increasingly high quality factors, which correspond to extremely narrow linewidths. In such systems, time variation of the resonator’s natural frequency can potentially impact its ability to accumulate power and its resulting sensitivity. One such example is the Dark SRF experiment, which utilizes superconducting radio frequency (SRF) cavities with quality factors of Q ∼ 10 10 . Microscopic deformations of the cavity lead to stochastic jittering of its resonant frequency with amplitude 20 times its linewidth. Naively, one may expect this to lead to a large suppression in accumulated power. In this work, we study in detail the effects of frequency instability on high-quality resonant systems, utilizing the Dark SRF experiment as a case study. We show that the timescale of jittering is crucial to determining its effect on power accumulation. Namely, when the resonant frequency varies sufficiently quickly, the system accumulates power as if there were no jittering at all. This implies that the sensitivity of a jittering resonator is comparable to that of a stable resonator. In the case of Dark SRF, we find that jittering only induces a ∼ 10 % loss in power. Our results allow the dark-photon exclusion bound from Dark SRF’s pathfinder run to be refined, leading to a constraint that is an order of magnitude stronger than previously reported (corresponding to a signal-to-noise ratio that is four orders of magnitude larger). This result represents the world-leading constraint on dark photons over a wide range of masses below 6 μ eV and translates to the best laboratory-based limits on the photon mass m γ < 2.9 × 10 - 48 g .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OC7 phase I: Toward practical sea-state-dependent modeling of hydrodynamic viscous drag and damping

Here, this article presents a collaborative research campaign under the OC7 project on refining the engineering modeling approach for hydrodynamic viscous drag and damping on floating wind platforms, focusing on the adjustment of hydrodynamic drag and damping coefficients for different sea states. The participant simulation results show significant improvements over the previous OC6 project in predicting the low-frequency resonance motion under nonoperational conditions. The improvements are mainly due to enhanced modeling, including the adoption of wave stretching, and directly tuning the coefficients to measured platform motion in waves instead of free decay. For accurate predictions of mean- and slow-drift motion, the better performing models use a decreasing column splash zone drag coefficient and increasing surge damping/drag with increasing wave height. The model tuning for heave and pitch resonance shows less consistency. Generally, both quadratic drag and additional heave or pitch damping are needed for accurate predictions. Alternatively, a quadratic drag formulation with velocity filtering for the rectangular pontoons leads to improved predictions without additional damping. This model is also potentially more predictive, requiring minimal adjustment to its parameters for different conditions.

17 WIND ENERGY↗

Toward the Development of Molten Salt Reactor Diagnostics based on Resonantly Enhanced Laser Spectroscopy

One emerging concern within the safeguards community is how to best ensure compliance with nuclear security regulations within molten salt reactor (MSR) facilities. This problem is nontrivial as molten salts used for fuel or coolant are highly corrosive, chemically complex, and inherently require high operational temperatures. Laser spectroscopy methods such as laser-induced breakdown spectroscopy (LIBS) and laser-induced fluorescence (LIF) have previously been suggested for molten salt diagnostics due to their compatibility with liquid phase samples and potential for in-situ measurements [1]. In the former, the laser is used to ionize the sample, allowing for the characteristic light from electronic de-excitation as the resultant plasma cools to be used for material characterization. In the latter, a tunable light source is set be resonant with a specific transition, resulting in element specific excitation and the emission of fluorescence light. In our previous work [2], we demonstrated that LIF could be used for the detection of fission fragments such as Nd in solution through the separation of laser scatter and fluorescence within the time domain. Here, we present progress towards two alternate measurement schemes: LIF measurements based on spectroscopic discrimination of fluorescence emissions and resonant LIBS measurements that induce plasma using a light source set to the resonant frequency of a specific electronic transition. Both methods aim to exploit resonant excitation methods to enhance the emitted signal. The studies may provide routes for element-specific detection of constituents within complicated matrices and a means to better understand the chemical behavior of lanthanides and actinides relevant to MSRs.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Room‐Temperature Mid‐Infrared Detection Using Metasurface‐Absorber‐Integrated Phononic Crystal Oscillator

Mid-infrared (MIR) detectors find extensive applications in chemical sensing, spectroscopy, communications, biomedical diagnosis, and space exploration. Alternative to semiconductor MIR photodiodes and bolometers, mechanical-resonator-based MIR detectors show advantages in higher sensitivity and lower noise at room temperature, especially toward longer wavelength infrared. Here, uncooled room-temperature MIR detectors based on lithium niobate surface acoustic wave phononic crystal (PnC) resonators integrated with wavelength-and-polarization-selective metasurface absorber arrays are demonstrated. The detection is based on the resonant frequency shift induced by the local temperature change due to MIR absorptions. The PnC resonator is configured in an oscillating mode, enabling active readout and low-frequency noise. The 1-GHz oscillator-based MIR detector shows a relative frequency deviation of 5.24 × 10 −10 Hz −1/2 at an integration time of 50 µs, leading to an incident noise equivalent power of 197 pW Hz −1/2 when input 6-µm MIR light is modulated at 1.8 kHz, and a large dynamic range of 10 7 in incident MIR power. The device architecture is compatible with the scalable manufacturing process and can be readily extended to a broader spectral range by tailoring the absorbing wavelengths of metasurface absorbers.

Xi, Zichen [Virginia Polytechnic Inst. and State U↗