Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESONANCE INTEGRALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Neutron Thermal Cross Sections, Westcott Factors, Resonance Integrals, Maxwellian Averaged Cross Sections and Astrophysical Reaction Rates Calculated from the ENDF/B-VII.1, JEFF-3.1.2, JENDL-4.0, ROSFOND-2010, CENDL-3.1 and EAF-2010 Evaluated Data Libraries

We present calculations of neutron thermal cross sections, Westcott factors, resonance integrals, Maxwellian-averaged cross sections and astrophysical reaction rates for 843 ENDF materials using data from the major evaluated nuclear libraries and European activation file. Extensive analysis of newly-evaluated neutron reaction cross sections, neutron covariances, and improvements in data processing techniques motivated us to calculate nuclear industry and neutron physics quantities, produce s-process Maxwellian-averaged cross sections and astrophysical reaction rates, systematically calculate uncertainties, and provide additional insights on currently available neutron-induced reaction data. Nuclear reaction calculations are discussed and new results are presented. Due to space limitations, the present paper contains only calculated Maxwellian-averaged cross sections and their uncertainties. The complete data sets for all results are published in the Brookhaven National Laboratory report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Cross Sections and Resonance Integrals for Ag{sup 109}(n,{gamma})Ag{sup 110m} and Several Other Reactions

In this paper measurements reported from the Rikkyo Research Reactor are reanalysed using a least squares adjustment procedure in which the adjustable parameters were the thermal and epithermal neutron fluences, the epithermal shape parameter and the thermal neutron cross sections and resonance integrals of all the dosimeters, including the gold and cobalt standards. The methodology and the results are described. Nuclear data including cross sections, recommended in ASTM Standard Test Method E 481, for the {sup 59}Co(n,{gamma}){sup 60}Co and Ag{sup 109}(n,{gamma})Ag{sup 110m} reactions were changed in a recent revision of the standard. The change for the silver thermal neutron cross section was very large compared to the previously cited uncertainties. The reference cited in the standard is the only new measurement that has been reported in many years. The value reported there for the 2200 m/s cross section is 4.12 {+-} 0.10 barn. This reevaluation adjusts that value to 3.87 {+-} 0.08 barn. The value in the previous edition of E481, however, was 4.7 barns {+-} 4%. Such a large change greatly affects the neutron fluence values that will be calculated. (author)

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of the thermal neutron capture cross section and the resonance integral of radioactive {sup 182}Hf

The neutron capture cross sections of the radioactive isotope {sup 182}Hf (t{sub 1/2}=8.9x10{sup 6} yr) in the thermal and epithermal energy regions have been measured by activation at the TRIGA Mark-II reactor of the Atomic Institute of the Austrian Universities in Vienna, Austria, and subsequent {gamma}-ray spectroscopy of {sup 183}Hf. High values for the thermal (kT=25 meV) cross section {sigma}{sub 0}=133{+-}10 b and for the resonance integral I{sub 0}=5850{+-}660 b were found. Additionally, the absolute intensities of the main {gamma}-ray transitions in the decay of {sup 182}Hf have been considerably improved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commercially Fabricated Low Loss Superconducting Resonators Integrated With Detectors for Frequency Domain Multiplexing Readout of Future Cosmic Microwave Background Experiments

Planned Stage-IV cosmic microwave background (CMB) experiments call for telescopes with the order of 500 000 transition edge sensor (TES) bolometers. Such large arrays would benefit from detector multiplexing, as well as miniaturization and integration of readout components. Additionally, fabrication of micro-fabricated devices at a commercial foundry could potentially boost production rate and reduce overall cost. To this end, HYPRES, Inc., LBNL, and U.C. Berkeley are developing low loss, superconducting LC resonators integrated with antenna coupled TES bolometers for frequency multiplexing readout. The resonators are fabricated on the same wafer and are in the same process flow as the TES detectors, reducing size, weight, and wiring complexity of a detector module compared to the conventional design, where each component is fabricated separately. We have fabricated and tested resonators from 0.6 to 70 MHz, both as standalone devices and integrated with TES bolometers, all fabricated on 150- mm wafers. Finally, we discuss the design and fabrication of these devices and present measurements of the standalone resonators.

47 OTHER INSTRUMENTATION↗

Tables of Neutron Thermal Cross Sections, Westcott Factors, Resonance Integrals, Maxwellian Averaged Cross Sections, Astrophysical Reaction Rates, and r-process Abundances Calculated from the ENDF/B-VIII.1, JEFF-3.3, JENDL-5.0, BROND-3.1, and CENDL-3.2 Evaluated Data Libraries

We present calculations of neutron thermal cross sections, Westcott factors, resonance integrals, Maxwellian-averaged cross sections, astrophysical reaction rates, and solar system r-process abundances using the latest data from the major evaluated nuclear libraries for 849 ENDF target materials. The recent release of ENDF/B-VIII.1 library, progress in 252 Cf(SF) evaluation, extensive analysis of newly-evaluated neutron reaction cross sections, neutron covariances, and improvements in data processing techniques motivated us to calculate the nuclear industry and neutron physics parameters, produce s-process Maxwellian-averaged cross sections and astrophysical reaction rates, extract r-process abundances, systematically calculate uncertainties, and provide additional insights on currently available neutron-induced reaction data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated system modeling analysis of a cryogenic multi-cell deflecting-mode cavity resonator

A deflecting mode cavity is the integral element for six-dimensional phase-space beam control in bunch compressors and emittance transformers at high energy beam test facilities. RF performance of a high-Q device is, however, highly sensitive to operational conditions, in particular in a cryo-cooling environment. Using analytic calculations and RF simulations, we examined cavity parameters and deflecting characteristics of TM{sub 110,π} mode of a 5 cell resonator in a liquid nitrogen cryostat, which has long been used at the Fermilab A0 Photoinjector (A0PI). The sensitivity analysis indicated that the cavity could lose 30%–40% of deflecting force due to defective input power coupling accompanying non-uniform field distribution across the cells with 40 ∼ 50 MeV electron beam and 70–80 kW klystron power. Vacuum-cryomodules of the 5 cell cavity are planned to be installed at the Fermilab Advanced Superconducting Test Accelerator facility. Comprehensive modeling analysis integrated with multi-physics simulation tools showed that RF loading of 1 ms can cause a ∼5 K maximum temperature increase, corresponding to a ∼4.3 μm/ms deformation and a 1.32 MHz/K maximum frequency shift. The integrated system modeling analysis will improve design process of a high-Q cavity with more accurate prediction of cryogenic RF performance under a high power pulse operation.

43 PARTICLE ACCELERATORS↗

Diamond electro-optomechanical resonators integrated in nanophotonic circuits

Diamond integrated photonic devices are promising candidates for emerging applications in nanophotonics and quantum optics. Here, we demonstrate active modulation of diamond nanophotonic circuits by exploiting mechanical degrees of freedom in free-standing diamond electro-optomechanical resonators. We obtain high quality factors up to 9600, allowing us to read out the driven nanomechanical response with integrated optical interferometers with high sensitivity. We are able to excite higher order mechanical modes up to 115 MHz and observe the nanomechanical response also under ambient conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Injector with integrated resonator

The system may include a turbine engine. The turbine engine may include a fuel nozzle. The fuel nozzle may include an air path. The fuel nozzle may also include a fuel path such that the fuel nozzle is in communication with a combustion zone of the turbine engine. Furthermore, the fuel nozzle may include a resonator. The resonator may be disposed in the fuel nozzle directly adjacent to the combustion zone.

42 ENGINEERING↗

Experimental Determination of the Effective Resonance Absorption Integrals of {sup 238}U and {sup 158}Gd in Urania–Gadolinia Rods

The experimental procedure and the results of determination of the effective resonance neutron absorption integrals of {sup 238}U and {sup 158}Gd for isolated UO{sub 2}–Gd{sub 2}O{sub 3} rods are presented. Measurements were performed using the activation method. UO{sub 2}–Gd{sub 2}O{sub 3} rods were irradiated in the neutron field with the Fermi spectrum formed at the center of the core of the F-1 research reactor at the National Research Centre Kurchatov Institute.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated reference cavity with dual-mode optical thermometry for frequency correction

Photonic integrated resonators have advantages over traditional benchtop cavities in terms of size, weight, and cost with the potential to enable applications that require spectrally pure light. However, integrated resonators suffer from temperature-dependent frequency variations and are sensitive to external environmental perturbations, which hinders their usage in precision frequency applications. One solution is to use interrogation of the cavity temperature through dual-mode optical thermometry (DMOT) by measuring the shift of the resonance frequency difference between two polarization or optical frequency modes. Yet this approach has only been demonstrated in bulk-optic whispering gallery mode and fiber resonators. In this paper, we implement dual-mode optical thermometry in an ultra-high Q integrated silicon nitride resonator. A dual-mode resonance frequency difference temperature sensitivity of 188 ± <#comment/> 15 M H z / K is measured. We demonstrate feedforward DMOT frequency correction that, under an applied external temperature ramp, is able to reduce the optical frequency change to 0.31 kHz/s as compared to an uncorrected 10.03 kHz/s, a factor of 30 × <#comment/> reduction. These results show promise for on-chip frequency correction solutions for quantum, metrology, atomic, and coherent optical communications applications.

Zhao, Qiancheng (ORCID:0000000206968667)↗

Precise electron beam-based target-wavelength trimming for frequency conversion in integrated photonic resonators

We demonstrate post-fabrication target-wavelength trimming with a gallium phosphide on a silicon nitride integrated photonic platform using controlled electron-beam exposure of hydrogen silsesquioxane cladding. A linear relationship between the electron-beam exposure dose and resonant wavelength red-shift enables deterministic, individual trimming of multiple devices on the same chip to within 30 pm of a single target wavelength. Second harmonic generation from telecom to near infrared at a target wavelength is shown in multiple devices with quality factors on the order of 10 4 . Post-fabrication tuning is an essential tool for targeted wavelength applications including quantum frequency conversion.

Thiel, Lillian↗

The Nonuniversality of the Frequency Dependence of the Conductivity in Disordered Nanogranulated Systems

The real part of the high-frequency phononless conductivity is calculated in the pair approximation for a disordered array of densely packed spherical nanogranules. The generalization of the theory of phononless conductivity for systems with point impurities to systems with localized finite sizes (arrays of nanogranules or quantum dots) reveals that the high-frequency conductivity depends on the distribution function of the distances between the surfaces of granules P(w). This is expected to cause the discrepancy of the real part of the conductivity σ{sub 1}(ω) from the linear frequency dependence. In the vicinity of the frequency ω ~ ω{sub c} = 2I{sub 0}/ℏ (here I{sub 0} is a preexponential factor of the resonance integral) for disordered granulated systems is likely to deviate from the universality σ{sub 1}(ω) ~ ω{sup s} (s ≈ 1) due to the attenuation of the frequency dependence σ{sub 1}(ω) of the conductivity and its nonmonotonicity. The nonmonotonicity of σ{sub 1}(ω) must arise at lower frequencies as a result of decreased preexponential factor I{sub 0} of the resonance integral with increasing granule size.

77 NANOSCIENCE AND NANOTECHNOLOGY↗