Experimental evaluation of common spacecraft data analysis techniques for reconnection region analysis in a laboratory plasma: EXPERIMENTAL EVALUATION OF SPACECRAFT DATA ANALYSIS
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
We used time-resolved photoluminescence (TRPL) spectroscopy to analyze time-domain and spectral-domain charge-carrier dynamics in CuIn{sub 1−x}Ga{sub x}Se{sub 2} (CIGS) photovoltaic (PV) devices. This new approach allowed detailed characterization for the CIGS/CdS buffer interface and for the space-charge region. We find that dynamics at the interface is dominated by diffusion, where the diffusion rate is several times greater than the thermionic emission or interface recombination rate. In the space-charge region, the electric field of the pn junction has the largest effect on the carrier dynamics. Based on the minority-carrier (electron) drift-rate dependence on the electric field strength, we estimated drift mobility in compensated CuIn{sub 1−x}Ga{sub x}Se{sub 2} (with x ≈ 0.3) as 22 ± 2 cm{sup 2}(Vs){sup −1}. Analysis developed in this study could be applied to evaluate interface and junction properties of PV and other electronic devices. For CIGS PV devices, TRPL spectroscopy could contribute to understanding effects due to absorber compositional grading, which is one of the focus areas in developing record-efficiency CIGS solar cells.
Dynamic Wireless Power Transfer (dWPT) is a method by which battery electric vehicles (BEVs) can charge their battery while traveling on the road without the need for a physical conductive connection to the power source. dWPT has been proposed as a strategy to enable a reduction in vehicle battery capacity and associated mass and cost. In this slide deck presented at the EVs@Scale Consortium - Wireless Power Transfer Pillar Deep-Dive Meeting on November 11th, 2023, NREL provides results from an evaluation of dWPT using data from Class 8 tractors driving in the Atlanta Metro Area. NREL selected data for archetypal days representing local, regional, and long-haul trips, defined according to trip length, that included travel on primary roadways. EVI-InMotion (Electric Vehicle Infrastructure - InMotion), a systems planning and optimization tool developed at NREL, was used to evaluate dWPT performance assuming dWPT charging on 120 road segments for a total roadway lane distance of 2,365 miles. The EVI-InMotion results and representative day drive cycles were analyzed with NREL's T3CO (Transportation Technology Total Cost of Ownership) tool to estimate the total cost of ownership (TCO) for scenarios comprising two model years - 2030 and 2040 - and two technology progress cases. TCO was calculated for diesel, fuel cell electric, BEVs with batteries sized assuming no dWPT capabilities, and 200kWh BEVs with dWPT installed. This analysis finds that en-route stationary charging frequency and downtime when not on electrified roadways are the main contributors to TCO for the dWPT vehicles and that these vehicles can achieve cost parity with FCEVs at low electricity costs. Based on the scenario assumptions used here, low electricity costs would further help the cost parity with diesel vehicles in regional and long-haul cases due to stationary fueling downtime. This presentation also concludes that key factors affecting the parity potential of dWPT-capable vehicles include more extensive dWPT road coverage, higher en-route charging power, less expensive power batteries, and higher hydrogen or diesel fuel costs.
Compartment fires exhibit unique features associated with smoke accumulation and restricted air ventilation. The objective of the present study is to evaluate the ability of CFD-based fire models to simulate these features and in particular the effects of flame extinction that results from under-ventilated fire conditions. The study is performed using FireFOAM; FireFOAM is an advanced fire modeling software developed by FM Global and is based on a general-purpose open-source software called OpenFOAM. A new flame extinction model based on the concept of a critical value of the flame Damköhler number is incorporated into FireFOAM. The performance of the extinction model is evaluated via comparisons with a previously developed experimental database corresponding to a reduced-scale, heptane-fueled, compartment fire configuration. The numerical simulations also include a description of fuel evaporation driven by the computed gas-to-liquid heat feedback. Comparisons between experimental data and numerical results provide a suitable test bed to evaluate the ability of CFD-based fire models to describe the transition from over- to under-ventilated fire conditions, as well as the transition from extinction-free conditions to conditions in which the flame experiences partial or total quenching.
The following paper conducts a regional analysis of the U.S. and Chinese buildings? potential for adopting Distributed Energy Resources (DER). The expected economics of DER in 2020-2025 is modeled for a commercial and a multi-family residential building in different climate zones. The optimal building energy economic performance is calculated using the Distributed Energy Resources Customer Adoption Model (DER CAM) which minimizes building energy costs for a typical reference year of operation. Several DER such as combined heat and power (CHP) units, photovoltaics, and battery storage are considered. The results indicate DER have economic and environmental competitiveness potential, especially for commercial buildings in hot and cold climates of both countries. In the U.S., the average expected energy cost savings in commercial buildings from DER CAM?s suggested investments is 17percent, while in Chinese buildings is 12percent. The electricity tariffs structure and prices along with the cost of natural gas, represent important factors in determining adoption of DER, more so than climate. High energy pricing spark spreads lead to increased economic attractiveness of DER. The average emissions reduction in commercial buildings is 19percent in the U.S. as a result of significant investments in PV, whereas in China, it is 20percent and driven by investments in CHP. Keywords: Building Modeling and Simulation, Distributed Energy Resources (DER), Energy Efficiency, Combined Heat and Power (CHP), CO2 emissions 1. Introduction The transition from a centralized and fossil-based energy paradigm towards the decentralization of energy supply and distribution has been a major subject of research over the past two decades. Various concerns have brought the traditional model into question; namely its environmental footprint, its structural inflexibility and inefficiency, and more recently, its inability to maintain acceptable reliability of supply. Under such a troubled setting, distributed energy resources (DER) comprising of small, modular, electrical renewable or fossil-based electricity generation units placed at or near the point of energy consumption, has gained much attention as a viable alternative or addition to the current energy system. In 2010, China consumed about 30percent of its primary energy in the buildings sector, leading the country to pay great attention to DER development and its applications in buildings. During the 11th Five Year Plan (FYP), China has implemented 371 renewable energy building demonstration projects, and 210 photovoltaics (PV) building integration projects. At the end of the 12th FYP, China is targeting renewable energy to provide 10percent of total building energy, and to save 30 metric tons of CO2 equivalents (mtce) of energy with building integrated renewables. China is also planning to implement one thousand natural gas-based distributed cogeneration demonstration projects with energy utilization rates over 70percent in the 12th FYP. All these policy targets require significant DER systems development for building applications. China?s fast urbanization makes building energy efficiency a crucial economic issue; however, only limited studies have been done that examine how to design and select suitable building energy technologies in its different regions. In the U.S., buildings consumed 40percent of the total primary energy in 2010 [1] and it is estimated that about 14 billion m2 of floor space of the existing building stock will be remodeled over the next 30 years. Most building?s renovation work has been on building envelope, lighting and HVAC systems. Although interest has emerged, less attention is being paid to DER for buildings. This context has created opportunities for research, development and progressive deployment of DER, due to its potential to combine the production of power and heat (CHP) near the point of consumption and delivering multiple benefits to customers, such as cost
The National Renewable Energy Laboratory's Scenario Evaluation and Regionalization Analysis (SERA) model estimates the number, size, and locations of hydrogen refueling stations that satisfy the fuel demand from fuel cell electric vehicles (FCEVs) and the hydrogen supply requirements to meet such a demand in terms of hydrogen production plants and delivery infrastructure. SERA simulates the systemwide cost-optimal evolution of hydrogen refueling infrastructure, providing insights that reduce the informational and financial risks associated with infrastructure investment decisions and helping accelerate the adoption of FCEVs. This report describes the SERA model's demand-side and refueling infrastructure buildout algorithms, and it also illustrates use of the model for simulating hydrogen refueling stations deployment scenarios using as an example the recent H2USA national hydrogen infrastructure report.
Although the traditional design of doubly-fed induction generators (DFIGs)’ interfacing inductors consider the peak ripple of the grid-side converter (GSC)’s output current, it does not consider the inductors’ impact on DFIGs’ smallsignal stability. Located in series between the GSC and the stator, the inappropriate selection of the interfacing inductor can easily result to system instability. Therefore, this paper first proposes the integrated reference region analysis for small wind farm's interfacing inductors to improve the traditional design method. Firstly, a new detailed parallel DFIGs’ smallsignal model that considers output currents’ coupling is built in d-q coordinate system with state-space approach. The model focuses on representing the operating states of parallel DFIGs in wind farm. Secondly, the linearized state-space matrix of parallel DFIGs is decomposed into nominal-value matrix and location matrix. Considering the traditional design requirements, the integrated reference region for interfacing inductor is proposed through spectral radius and bialternate matrix sum (BMS). Furthermore, it can provide better guidance for parameter selecting and stabilization method researches. Finally, the simulation and experimental results show that the proposed integrated reference region for parallel DFIGs’ interfacing inductors is accurate and instructive.
European climate polices acknowledge the role that energy communities can play in the energy transition. Self-consumption installations shared among those living in the same building are a good example of such energy communities. In this work, a regional analysis of optimal self-consumption installations under the new legal framework recently passed in Spain is performed. Results show that the optimal sizing of the installation leads to economic savings for self-consumers in all the territory, for both options with and without remuneration for energy surplus. A sensitivity analysis on technology costs revealed that batteries still require noticeably cost reductions to be cost-effective in a behind the meter self-consumption environment. In addition, solar compensation mechanisms make batteries less attractive in a scenario of low PV costs, since feeding PV surplus into the grid, yet less efficient, becomes more cost-effective. Furthermore, an improvement for the energy surplus remuneration policy in the context of the current legislation was proposed and analysed. It consists in the inclusion of the economic value of the avoided power losses in the remuneration.
This paper examines China’s regional electricity grids using a reliability perspective, which is commonly measured in terms of a reserve margin. Our analysis shows that at the end of 2014, the average reserve margin for China as a whole was roughly 28%, almost twice as high as a typical planning reserve margin in the U.S. However, this national average masks huge variations in reserve margins across major regional power grid areas: the northeastern region has the highest reserve margin of over 60%, followed by the northwestern region at 49%, and the southern grid area at 35%. In this analysis, we also examined future reserve margins for regional electricity grids in China under two scenarios: 1) a low scenario of national annual electricity consumption growth rates of 1.5% between 2015 and 2020 and 1.0% between 2020 and 2025, and 2) a high scenario of annual average growth rates of 3.0% and 2.0%, respectively. Both scenarios suggest that the northeastern, northwestern, and southern regions have significant excess generation capacity, and that this excess capacity situation will continue over the next decade without regulatory intervention. The northern and central regions could have sufficient generation capacity to 2020, but may require additional resources in a higher growth scenario. The eastern region requires new resources by 2020 in both scenarios.
The Baltimore Metropolitan Council conducted the Baltimore Regional Household Travel Survey to collect demographic and travel features. The travel data mainly focus on weekday travel, collecting 27,363 one-day travel itineraries from 3,131 Baltimore-region households in June 2001. The council also sampled a smaller survey of 325 households to obtain weekend travel behavior.
Aluminum and steel represent the two most dominant metals in light duty vehicles, yet the flows of these materials into the American automotive industry have not been well characterized. This study proposes and implements a method for analyzing the flow of these metals into the automotive industry. We create a framework for performing regionally linked, sector specific material flow analyses and use this framework to trace flows of aluminum and steel entering the American automotive industry, focusing on flows downstream from raw material production. We show that automotive aluminum sheet and extrusions are sourced primarily from the NPCC (23%), SERC (20%), MRO (18%), and RFC (13%) NERC regions and a spatially unresolved Local region within the U.S. and Canada (18%). We determine that primary aluminum is largely from Canada (70%), nearly all from Quebec (69%). Further upstream, alumina and bauxite originate mostly from Brazil, Australia, and Jamaica. We also show that finished automotive steel is sourced primarily from the RFC (63%) and SERC (20%) regions. The crude steel supply similarly originates mainly from the RFC (69%) and SERC (7%) regions. Upstream raw materials including coke, coking coal, iron ore, lime, and steel scrap are primarily sourced from the U.S. with only direct reduced iron and pig iron used in electric arc furnace steel production coming mostly from outside the U.S. The framework developed here allows for increased spatial resolution of material flows, which can be used to develop more specific life cycle impact factors for life cycle assessments.
The goal of this project undertaken by GLBRC (Great Lakes Bioenergy Research Center) Area 4 (Sustainability) modelers is to develop a national capability to model feedstock supply, ethanol production, and biogeochemical impacts of cellulosic biofuels. The results of this project contribute to sustainability goals of the GLBRC; i.e. to contribute to developing a sustainable bioenergy economy: one that is profitable to farmers and refiners, acceptable to society, and environmentally sound. A sustainable bioenergy economy will also contribute, in a fundamental way, to meeting national objectives on energy security and climate mitigation.
The goal of this project undertaken by GLBRC (Great Lakes Bioenergy Research Center) Area 4 (Sustainability) modelers is to develop a national capability to model feedstock supply, ethanol production, and biogeochemical impacts of cellulosic biofuels. The results of this project contribute to sustainability goals of the GLBRC; i.e. to contribute to developing a sustainable bioenergy economy: one that is profitable to farmers and refiners, acceptable to society, and environmentally sound. A sustainable bioenergy economy will also contribute, in a fundamental way, to meeting national objectives on energy security and climate mitigation.
China's economy has entered a “new normal,” characterized by slower economic growth and widespread overcapacity in its industrial sectors. Nevertheless, construction of power plants, especially coal-fired plants, continues at a rapid pace. Our analysis examines the extent of overcapacity in China's regional electricity grids. We show that already in 2014, the average reserve margin across China's regional grids was roughly 28%, almost twice as high as a standard planning reserve margin in the U.S. In addition, we find large variations in reserve margins across regional power grids in China, with the highest reserve margin (64%) in the Northeastern grid. This paper examines future reserve margins across regions in China under three growth scenarios. The results suggest that the majority of China will not need new baseload coal power (at least for reliability purposes) before 2020, and potentially not until 2025, under the low- and mid-growth scenarios. Under the high-growth scenario, China's central and eastern regions will need to import more power or built new capacity by 2020. As China's energy sector enters this new normal, our results highlight the growing importance of establishing mechanisms — planning processes and markets — that coordinate generation and transmission investments across grid regions, and that align the country's energy sector investments with its longer-term air quality and climate goals.
Abstract Accurate assessments of forest response to current and future climate and human actions are needed at regional scales. Predicting future impacts on forests will require improved analysis of species‐level adaptation, resilience, and vulnerability to mortality. Land system models can be enhanced by creating trait‐based groupings of species that better represent climate sensitivity, such as risk of hydraulic failure from drought. This emphasizes the need for more coordinated in situ and remote sensing observations to track changes in ecosystem function, and to improve model inputs, spatio‐temporal diagnosis, and predictions of future conditions, including implications of actions to mitigate climate change.
As the number of inverter-interfaced distributed generators (IIDGs) increases, the decrease in the inertia of the microgrid affects the stability of microgrid voltage and current. The virtual synchronous generator (VSG) control method simulates the output characteristics of the synchronous machine to improve the inertia and damping of the microgrid. However, low-frequency oscillations can occur in systems with multi-VSGs connected in parallel, primarily when operating in island mode. Therefore, this article develops the small-signal state-space model for multi-inverters based on VSG and analyses the robust stability region (RSR) of the control parameters. Firstly, an extensible small-signal state-space model is established and simplified in the dq axis, which is a necessary preprocessing for the subsequent stability analysis. Secondly, the guardian map method based on bialternate product operation is constructed, and the RSR is established through translation mapping and rotation mapping. Therefore, the solution of RSR is transformed into the problem of identifying the Hurwitz matrix. Finally, the simulations and experiments verify that the calculated region can ensure stable operation during startup and meet the requirement to suppress low-frequency oscillations. In conclusion, the method of solving RSR proposed in this paper provides a basis for selecting controller parameters in practical engineering.
Recently, great interest has been generated in using lead as a coolant for fast neutron systems and as a result it is important to investigate the ENDF/B-VIII.0 isotopic evaluations that comprise stable le ad. To this end, resonance parameters for 206 Pb, 207 Pb, and 208 Pb were re-evaluated because their resolved resonance regions extend beyond 0.5 MeV meaning resonance parameters used in reconstructing cross sections and elastic scattering angular distributions impact fast systems. The impact of resonance parameters is demonstrated by the differences between the evaluations in predicting experimental results from the fully modeled RPI Quasi-Differential Scattering Experiment via MCNPv6.2. In addition, MCNP KCODE calculations of lead-sensitive fast spectra critical benchmarks showed variations of keff on average of 400 pcm, caused solely from differences in elastic scattering angular distributions in 208 Pb. Re-evaluation entailed fitting data with the program SAMMY.