Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRACTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Sequential Infiltration Synthesis for the Design of Low Refractive Index Surface Coatings with Controllable Thickness

Control over refractive index and thickness of surface coatings is central to the design of low refraction films used in applications ranging from optical computing to antireflective coatings. Here, we introduce gas-phase sequential infiltration synthesis (SIS) as a robust, powerful, and efficient approach to deposit conformal coatings with very low refractive indices. We demonstrate that the refractive indices of inorganic coatings can be efficiently tuned by the number of cycles used in the SIS process, composition, and selective swelling of the of the polymer template. We show that the refractive index of Al2O3 can be lowered from 1.76 down to 1.1 using this method. The thickness of the Al2O3 coating can be efficiently controlled by the swelling of the block copolymer template in ethanol at elevated temperature, thereby enabling deposition of both single-layer and graded-index broadband antireflective coatings. Using this technique, Fresnel reflections of glass can be reduced to as low as 0.1% under normal illumination over a broad spectral range.

Berman, Diana↗

Compositional dependence of optical band gap and refractive index in lead and bismuth borate glasses

Highlights: • Refractive indices increase with increasing PbO/Bi{sub 2}O{sub 3} content. • Optical band gap arises due to direct forbidden transition. • Optical band gaps decrease with increasing PbO/Bi{sub 2}O{sub 3} content. • New empirical relation between the optical band gap and the refractive index. - Abstract: We prepared a series of lead and bismuth borate glasses by varying PbO/Bi{sub 2}O{sub 3} content and studied refractive index and optical band gap as a function of glass composition. Refractive indices were measured very accurately using a Brewster’s angle set up while the optical band gaps were determined by analyzing the optical absorption edge using the Mott–Davis model. Using the Lorentz–Lorentz method and the effective medium theory, we calculated the refractive indices and then compared them with the measured values. Bismuth borate glasses show better agreement between the calculated values of the refractive index and experimental values. We used a differential method based on Mott–Davis model to obtain the type of transition and optical band gap (E{sub opt}) which in turn was compared with the value of E{sub opt} obtained using the extinction coefficient. Our analysis shows that in both lead and bismuth borate glasses, the optical band gap arises due to direct forbidden transition. With increasing PbO/Bi{sub 2}O{sub 3} content, the absorption edge shifts toward longer wavelengths and the optical band gap decreases. This behavior can be explained in terms of changes to the Pb−O/Bi−O chemical bonds with glass composition. We obtained a new empirical relation between the optical band gap and the refractive index which can be used to accurately determine the electronic oxide polarizability in lead and bismuth oxide glasses.

36 MATERIALS SCIENCE↗

Influence of refraction index strength on the light propagation in dielectrics material with periodic refraction index

This study investigated the influence of refraction index strength on the light propagation in refraction index-varied dielectric material. This dielectric material served as photonic lattice. The behavior of light propagation influenced by variation of refraction index in photonic lattice was investigated. Modes of the guiding light were determined numerically using squared-operator iteration method. It was found that the greater the strength of refraction index, the smaller the guiding modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Near-edge X-ray refraction fine structure microscopy

We demonstrate a method for obtaining increased spatial resolution and specificity in nanoscale chemical composition maps through the use of full refractive reference spectra in soft x-ray spectro-microscopy. Using soft x-ray ptychography, we measure both the absorption and refraction of x-rays through pristine reference materials as a function of photon energy and use these reference spectra as the basis for decomposing spatially resolved spectra from a heterogeneous sample, thereby quantifying the composition at high resolution. While conventional instruments are limited to absorption contrast, our novel refraction based method takes advantage of the strongly energy dependent scattering cross-section and can see nearly five-fold improved spatial resolution on resonance.

36 MATERIALS SCIENCE↗

Inserting a Low-Refractive-Index Dielectric Rear Reflector into PERC Cells: Challenges and Opportunities

One of the simplest and most effective ways to reduce the operating temperature of photovoltaic systems in the field is to reflect unusable, 'sub-bandgap' light with energies below the cell absorber's bandgap energy. In this work, low-refractive index SiO2 nanoparticle films inserted between c-Si wafers and metal electrodes significantly increase the reflectance of sub-bandgap light in fabricated test structures. These films are then integrated into the standard PERC fabrication sequence, revealing that the reflection benefits remains after some processing steps but are lost in certain conditions. The SiO2 nanoparticle films are easily ablated during laser contact opening, but are undesirably etched during post-laser cleaning. After Al metallization, the fully fabricated devices show enhanced sub-bandgap reflection when annealed at moderate temperatures, but energy-dispersive X-ray spectroscopy shows that high-temperature firing causes unwanted Al penetration into the SiO2 nanoparticle film, compromising reflection.

14 SOLAR ENERGY↗

Photo-induced refractive index and topographical surface gratings in functionalized nanocarbon solid film

We demonstrate that a single-walled carbon nanotube network noncovalently coupled with a pyrene-modified azo-benzene chromophore functions as a host matrix for a broad range of photo-orientation and photomechanical effects. The chromophore could be efficiently reoriented through repeated trans-cis-trans isomerization under linearly polarized 480 nm light, with Δn of 0.012 at 650 nm and fast characteristic rise-times of 0.12 s. Erasable phase diffraction gratings could also be written, with permanent surface relief gratings forming at sufficiently long irradiation times. In addition to demonstrating a mechanism for photo-manipulation of single-walled carbon nanotubes, these results show photo-orientation of chromophores in azo-functionalized single-walled carbon nanotube networks as a path towards the photosensitive tuning of the electrostatic environment of the nanotube.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Talbot-Lau x-ray deflectometer: Refraction-based HEDP imaging diagnostic

Talbot-Lau x-ray interferometry has been implemented to map electron density gradients in High Energy Density Physics (HEDP) experiments. X-ray backlighter targets have been evaluated for Talbot-Lau X-ray Deflectometry (TXD). Cu foils, wires, and sphere targets have been irradiated by 10–150 J, 8–30 ps laser pulses, while two pulsed-power generators (∼350 kA, 350 ns and ∼200 kA, 150 ns) have driven Cu wire, hybrid, and laser-cut x-pinches. A plasma ablation front generated by the Omega EP laser was imaged for the first time through TXD for densities >1023 cm−3. Backlighter optimization in combination with x-ray CCD, image plates, and x-ray film has been assessed in terms of spatial resolution and interferometer contrast for accurate plasma characterization through TXD in pulsed-power and high-intensity laser environments. The results obtained thus far demonstrate the potential of TXD as a powerful diagnostic for HEDP.

Valdivia, M. P.↗

Effects of refractive index mismatch in optical CT imaging of polymer gel dosimeters

Purpose: Proposing an image reconstruction technique, algebraic reconstruction technique-refraction correction (ART-rc). The proposed method takes care of refractive index mismatches present in gel dosimeter scanner at the boundary, and also corrects for the interior ray refraction. Polymer gel dosimeters with high dose regions have higher refractive index and optical density compared to the background medium, these changes in refractive index at high dose results in interior ray bending. Methods: The inclusion of the effects of refraction is an important step in reconstruction of optical density in gel dosimeters. The proposed ray tracing algorithm models the interior multiple refraction at the inhomogeneities. Jacob’s ray tracing algorithm has been modified to calculate the pathlengths of the ray that traverses through the higher dose regions. The algorithm computes the length of the ray in each pixel along its path and is used as the weight matrix. Algebraic reconstruction technique and pixel based reconstruction algorithms are used for solving the reconstruction problem. The proposed method is tested with numerical phantoms for various noise levels. The experimental dosimetric results are also presented. Results: The results show that the proposed scheme ART-rc is able to reconstruct optical density inside the dosimeter better than the results obtained using filtered backprojection and conventional algebraic reconstruction approaches. The quantitative improvement using ART-rc is evaluated using gamma-index. The refraction errors due to regions of different refractive indices are discussed. The effects of modeling of interior refraction in the dose region are presented. Conclusions: The errors propagated due to multiple refraction effects have been modeled and the improvements in reconstruction using proposed model is presented. The refractive index of the dosimeter has a mismatch with the surrounding medium (for dry air or water scanning). The algorithm reconstructs the dose profiles by estimating refractive indices of multiple inhomogeneities having different refractive indices and optical densities embedded in the dosimeter. This is achieved by tracking the path of the ray that traverses through the dosimeter. Extensive simulation studies have been carried out and results are found to be matching that of experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Refractivity Observations from Radar Phase Measurements: The 22 May 2002 Dryline Case during IHOP Project

The dryline, often associated with the development of severe storms in the Southern Great Plains of the United States of America, is a boundary layer phenomenon that occurs when a warm and moist air mass from the Gulf of Mexico meets a hot and dry air mass from the southwest desert area. An accurate knowledge of the water vapor spatio-temporal variability in the lower part of the atmosphere is crucial for a better understanding of the evolution of the dryline. The tropospheric refractivity, directly related to water vapor content, is a proxy for the water vapor content of the troposphere. It has already been demonstrated that the refractivity and the refractivity vertical gradient can be jointly estimated from radar phase measurements. In fact, it has been shown that using kriging interpolation techniques, accurate refractivity maps within the coverage area of the radar can be obtained with high temporal resolution. In this paper, a detailed analysis of the time series of radar-based refractivity maps obtained during a dryline that occurred on the afternoon of 22 May 2002 during the International H 2 O Project is presented. Comparisons between the time series of radar refractivity maps, obtained with the NCAR S-Pol radar, and the refractivity measurements derived from automatic ground-based weather stations and the AERI instrument, placed at different locations within the coverage area of the NCAR S-Pol radar, demonstrate the accuracy of radar refractivity estimates even for highly variable conditions, both in time and space, in the troposphere. Correlation coefficients higher than 0.95 are obtained in all weather station locations. Regarding the RMSE, errors less than 6 N-units are obtained for all cases, being even as low as 2.92 N-units at some locations.

54 ENVIRONMENTAL SCIENCES↗

Optical CT imaging of solid radiochromic dosimeters in mismatched refractive index solutions using a scanning laser and large area detector

Purpose: The practical use of the PRESAGE® solid plastic dosimeter is limited by the inconvenience of immersing it in high-viscosity oils to achieve refractive index matching for optical computed tomography (CT) scanning. The oils are slow to mix and difficult to clean from surfaces, and the dosimeter rotation can generate dynamic Schlieren inhomogeneity patterns in the reference liquid, limiting the rotational and overall scan speed. Therefore, it would be beneficial if lower-viscosity, water-based solutions with slightly unmatched refractive index could be used instead. The purpose of this work is to demonstrate the feasibility of allowing mismatched conditions when using a scanning laser system with a large acceptance angle detector. A fiducial-based ray path measurement technique is combined with an iterative CT reconstruction algorithm to reconstruct images. Methods: A water based surrounding liquid with a low viscosity was selected for imaging PRESAGE® solid dosimeters. Liquid selection was optimized to achieve as high a refractive index as possible while avoiding rotation-induced Schlieren effects. This led to a refractive index mismatch of 6% between liquid and dosimeters. Optical CT scans were performed with a fan-beam scanning-laser optical CT system with a large area detector to capture most of the refracted rays. A fiducial marker placed on the wall of a cylindrical sample occludes a given light ray twice. With knowledge of the rotation angle and the radius of the cylindrical object, the actual internal path of each ray through the dosimeter can be calculated. Scans were performed with 1024 projections of 512 data samples each, and rays were rebinned to form 512 parallel-beam projections. Reconstructions were performed on a 512 × 512 grid using 100 iterations of the SIRT iterative CT algorithm. Proof of concept was demonstrated with a uniformly attenuating solution phantom. PRESAGE® dosimeters (11 cm diameter) were irradiated with Cobalt-60 irradiator to achieve either a uniform dose or a 2-level “step-dose” pattern. Results: With 6% refractive index mismatching, a circular field of view of 85% of the diameter of a cylindrical sample can be reconstructed accurately. Reconstructed images of the test solution phantom were uniform (within 3%) inside this radius. However, the dose responses of the PRESAGE® samples were not spatially uniform, with variations of at least 5% in sensitivity. The variation appears as a “cupping” artifact with less sensitivity in the middle than at the periphery of the PRESAGE® cylinder. Polarization effects were also detected for these samples. Conclusions: The fiducial-based ray path measurement scheme, coupled with an iterative reconstruction algorithm, enabled optical CT scanning of PRESAGE® dosimeters immersed in mismatched refractive index solutions. However, improvements to PRESAGE® dose response uniformity are required.

60 APPLIED LIFE SCIENCES↗