Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOWAVE RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Laser Guidance in C-Arm Cone-Beam CT-Guided Radiofrequency Ablation of Osteoid Osteoma Reduces Fluoroscopy Time

PurposeTo assess whether laser guidance can reduce fluoroscopy and procedure time of cone-beam computed tomography (CBCT)-guided radiofrequency (RF) ablations of osteoid osteoma compared to freehand CBCT guidance.Materials and Methods32 RF ablations were retrospectively analyzed, 17 laser-guided and 15 procedures using the freehand technique. Subgroup selection of 18 ablations in the hip–pelvic region with a similar degree of difficulty was used for a direct comparison. Data are presented as median (ranges).ResultsComparison of all 32 ablations resulted in fluoroscopy times of 365 s (193–878 s) for freehand and 186 s (75–587 s) for laser-guided procedures (p = 0.004). Corresponding procedure times were 56 min (35–97 min) and 52 min (30–85 min) (p = 0.355). The subgroup showed comparable target sizes, needle path lengths, and number of scans between groups. Fluoroscopy times were lower for laser-guided procedures, 215 s (75–413 s), compared to 384 s (193–878 s) for freehand (p = 0.012). Procedure times were comparable between groups, 51 min (30–72 min) for laser guidance and 58 min (35–79 min) for freehand (p = 0.172).ConclusionAdding laser guidance to CBCT-guided osteoid osteoma RF ablations significantly reduced fluoroscopy time without increasing procedure time.Level of EvidenceLevel 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pediatric Percutaneous Osteoid Osteoma Ablation: Cone-Beam CT with Fluoroscopic Overlay Versus Conventional CT Guidance

PurposeTo compare technical success, clinical success, complications, radiation dose, and total room utilization time for osteoid osteoma thermal (radiofrequency or microwave) ablation using cone-beam computed tomography (CBCT) with two-axis fluoroscopic navigational overlay versus conventional computed tomography (CT) guidance.Materials and MethodsA retrospective review was performed to identify all osteoid osteoma ablations performed over a 5.5-year period at a single tertiary care pediatric hospital. Twenty-five ablations (15 radiofrequency and 10 microwave) in 23 patients undergoing fluoroscopic CBCT-guided osteoid osteoma ablation were compared to 35 ablations (35 radiofrequency) in 32 patients undergoing ablation via conventional CT guidance. Dose area product and dose length product were recorded for CBCT and conventional CT, respectively, and converted to effective doses. Technical success, clinical success (cessation of pain and medication use 1 month after ablation), complications, radiation dose, and total room utilization time were compared.ResultsAll procedures were technically successful. Twenty-two of 25 (88.0%) CBCT and 31 of 35 (88.6%) conventional CT-guided ablations achieved immediate clinical success. There were two minor complications in each group and no major complications. Mean effective radiation dose was significantly lower for CBCT compared to CT guidance (0.12 vs. 0.39 mSv, p = 0.02). Mean total room utilization time for CBCT was longer (133.5 vs. 97.5 min, p = 0.0001).ConclusionsFluoroscopic CBCT guidance for percutaneous osteoid osteoma ablation yields similar technical and clinical success, reduced radiation dose, and increased total room utilization time compared to conventional CT guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A High-Order L-Band HTS Filter for Sensitive Detecting

In this paper, a new high-temperature superconducting (HTS)-based microwave radiometer with an improved sensitivity is presented. The cryogenic receiver front end consists of an HTS filter and a cryogenic low noise amplifier (LNA). The cryogenic receiver front end shows an ultra-low noise figure and can suppress radio frequency interference (RFI) effectively. The proposed HTS filter works at a center frequency of 1.4135 GHz with a bandwidth of 25 MHz. The measured mid-band insertion loss, side band steepness, and out-of-band attenuation of the HTS filter are 0.14 dB, 35 dB/MHz, and 80 dB, respectively. The noise figure of the cryogenic LNA is about 0.27 dB at a temperature of 77 K. Compared with other total power radiometers, the proposed radiometer has a lower receiver noise temperature, which can improve the sensitivity with a short integration time of the satellite-based salinity meter. In addition, since the bandwidth of the salinity meter is fixed and the integration time of satellite-based equipment is limited, such a low receiver noise temperature can increase the flexibility of future satellite payload configuration program.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the environmental broadband electromagnetic waves in a mid-size European city

In this paper, the level of exposure to broadband radiofrequency electromagnetic field in a mid-size European city was evaluated in accordance with the International Commission on Non-ionizing Radiation Protection guidelines from 1998. With the aim to analyse all the potential electromagnetic waves present in the city up to 18 GHz, a total of 271 locations distributed along Terrassa (Spain) have been measured. To show the results in an easy-to-interpret way by the citizen, the results have been represented in a set of raster maps. The measurement results obtained showed that the electromagnetic wave measured in all broadband frequency range along the city is much lower than the safety level according to the international regulations for both public and occupational sectors.

54 ENVIRONMENTAL SCIENCES↗

Absorption of wireless radiation in the child versus adult brain and eye from cell phone conversation or virtual reality

Highlights: • More cell phone radiation is absorbed by children's inner brain tissues than adults’. • Children's radiofrequency radiation exposure should be reduced. • Further research to evaluate the risks to the eye from use of VR is urgently needed. • It is biologically relevant and feasible to reduce the standards’ averaging volume. • Current methods to determine wireless device compliance should be revised. Children's brains are more susceptible to hazardous exposures, and are thought to absorb higher doses of radiation from cell phones in some regions of the brain. Globally the numbers and applications of wireless devices are increasing rapidly, but since 1997 safety testing has relied on a large, homogenous, adult male head phantom to simulate exposures; the “Standard Anthropomorphic Mannequin” (SAM) is used to estimate only whether tissue temperature will be increased by more than 1 Celsius degree in the periphery. The present work employs anatomically based modeling currently used to set standards for surgical and medical devices, that incorporates heterogeneous characteristics of age and anatomy. Modeling of a cell phone held to the ear, or of virtual reality devices in front of the eyes, reveals that young eyes and brains absorb substantially higher local radiation doses than adults’. Age-specific simulations indicate the need to apply refined methods for regulatory compliance testing; and for public education regarding manufacturers' advice to keep phones off the body, and prudent use to limit exposures, particularly to protect the young.

54 ENVIRONMENTAL SCIENCES↗

Effect of Radio-Frequency and Ionizing Radiation on the ATmega8515 Microcontroller

Effect of ultrabroadband radiation and bremsstrahlung on a complicated device (ATmega8515) placed in a radio-transparent housing is studied. Similar results are obtained in the two cases: short-term malfunction or hangup. A particular scenario depends on the moment of irradiation relative to the phase of the meander generated by the microcontroller. In the presence of bremsstrahlung, the effect depends on the exposure dose, so that an increase in the duration of the generated phase or hangup can be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Role of Cerenkov Radiation in the Pressure Balance of Cool Core Clusters of Galaxies

Despite the substantial progress made recently in understanding the role of AGN feedback and associated non-thermal effects, the precise mechanism that prevents the core of some clusters of galaxies from collapsing catastrophically by radiative cooling remains unidentified. In this Letter, we demonstrate that the evolution of a cluster's cooling core, in terms of its density, temperature, and magnetic field strength, inevitably enables the plasma electrons there to quickly become Cerenkov loss dominated, with emission at the radio frequency of ≲350 Hz, and with a rate considerably exceeding free–free continuum and line emission. However, the same does not apply to the plasmas at the cluster's outskirts, which lacks such radiation. Owing to its low frequency, the radiation cannot escape, but because over the relevant scale size of a Cerenkov wavelength the energy of an electron in the gas cannot follow the Boltzmann distribution to the requisite precision to ensure reabsorption always occurs faster than stimulated emission, the emitting gas cools before it reheats. This leaves behind the radiation itself, trapped by the overlying reflective plasma, yet providing enough pressure to maintain quasi-hydrostatic equilibrium. The mass condensation then happens by Rayleigh–Taylor instability, at a rate determined by the outermost radius where Cerenkov radiation can occur. In this way, it is possible to estimate the rate at ≈2 M {sub ⊙} year{sup −1}, consistent with observational inference. Thus, the process appears to provide a natural solution to the longstanding problem of “cooling flow” in clusters; at least it offers another line of defense against cooling and collapse should gas heating by AGN feedback be inadequate in some clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiofrequency and Microwave Ablation Compared to Systemic Chemotherapy and to Partial Hepatectomy in the Treatment of Colorectal Liver Metastases: A Systematic Review and Meta-Analysis

PurposeTo assess safety and outcome of radiofrequency ablation (RFA) and microwave ablation (MWA) as compared to systemic chemotherapy and partial hepatectomy (PH) in the treatment of colorectal liver metastases (CRLM).MethodsMEDLINE, Embase and the Cochrane Library were searched. Randomized trials and comparative observational studies with multivariate analysis and/or matching were included. Guidelines from National Guideline Clearinghouse and Guidelines International Network were assessed using the AGREE II instrument.ResultsThe search revealed 3530 records; 328 were selected for full-text review; 48 were included: 8 systematic reviews, 2 randomized studies, 26 comparative observational studies, 2 guideline-articles and 10 case series; in addition 13 guidelines were evaluated. Literature to assess the effectiveness of ablation was limited. RFA + systemic chemotherapy was superior to chemotherapy alone. PH was superior to RFA alone but not to RFA + PH or to MWA. Compared to PH, RFA showed fewer complications, MWA did not. Outcomes were subject to residual confounding since ablation was only employed for unresectable disease.ConclusionThe results from the EORTC-CLOCC trial, the comparable survival for ablation + PH versus PH alone, the potential to induce long-term disease control and the low complication rate argue in favour of ablation over chemotherapy alone. Further randomized comparisons of ablation to current-day chemotherapy alone should therefore be considered unethical. Hence, the highest achievable level of evidence for unresectable CRLM seems reached. The apparent selection bias from previous studies and the superior safety profile mandate the setup of randomized controlled trials comparing ablation to surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radio frequency radiation-related cancer: assessing causation in the occupational/military setting

Highlights: • Carcinogenicity of radio frequency radiation (RFR) was examined. • The focus was on hemolymphatic cancers in the occupational and military settings. • Unusually high proportion of hemolymphatic cancers was found in a case series. • Similar unusually high proportions were reported in three previous cohort studies. • The findings support a case for classifying RFR as a human carcinogen. We reexamine whether radio frequency radiation (RFR) in the occupational and military settings is a human carcinogen.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Laser cooling of {sup 171}Yb{sup +} ions in a frequency-modulated field

We have investigated the laser cooling of ytterbium ions in a radio-frequency trap by a frequency-modulated resonant laser field. It has been shown that the lowest laser cooling temperatures, close to the Doppler limit, can be reached at field modulation parameters μ ⩾ 0.1. At lower μ values, the region of field parameters optimal for cooling shifts to higher intensities and the minimum possible laser cooling temperature increases. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Southern H ii Region Discovery Survey (SHRDS): Pilot Survey

The Southern H ii Region Discovery Survey is a survey of the third and fourth quadrants of the Galactic plane that will detect radio recombination line (RRL) and continuum emission at cm-wavelengths from several hundred H ii region candidates using the Australia Telescope Compact Array. The targets for this survey come from the WISE Catalog of Galactic H ii Regions and were identified based on mid-infrared and radio continuum emission. In this pilot project, two different configurations of the Compact Array Broad Band receiver and spectrometer system were used for short test observations. The pilot surveys detected RRL emission from 36 of 53 H ii region candidates, as well as seven known H ii regions that were included for calibration. These 36 recombination line detections confirm that the candidates are true H ii regions and allow us to estimate their distances.

79 ASTRONOMY AND ASTROPHYSICS↗

An Interactive Multi-instrument Database of Solar Flares

Solar flares are complicated physical phenomena that are observable in a broad range of the electromagnetic spectrum, from radio waves to γ -rays. For a more comprehensive understanding of flares, it is necessary to perform a combined multi-wavelength analysis using observations from many satellites and ground-based observatories. For an efficient data search, integration of different flare lists, and representation of observational data, we have developed the Interactive Multi-Instrument Database of Solar Flares (IMIDSF, https://solarflare.njit.edu/). The web-accessible database is fully functional and allows the user to search for uniquely identified flare events based on their physical descriptors and the availability of observations by a particular set of instruments. Currently, the data from three primary flare lists ( Geostationary Operational Environmental Satellites , RHESSI , and HEK) and a variety of other event catalogs ( Hinode , Fermi GBM, Konus- W IND, the OVSA flare catalogs, the CACTus CME catalog, the Filament eruption catalog) and observing logs ( IRIS and Nobeyama coverage) are integrated, and an additional set of physical descriptors (temperature and emission measure) is provided along with an observing summary, data links, and multi-wavelength light curves for each flare event since 2002 January. We envision that this new tool will allow researchers to significantly speed up the search of events of interest for statistical and case studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Basic Knowledge in Soft Tissue Sarcoma

Sarcoma is rare and heterogenous with various subtypes having a different prognostic. Desmoid is a tumour with a local aggressiveness; GIST with KIT mutation responds massively to target treatment as IMATINIB, whereas soft tissue sarcoma and leiomyosarcoma are very aggressive with poor response to systemic therapies. Interventional radiology plays an important role in the diagnosis of sarcomas with image-guided percutaneous core needle biopsy being the most commonly used biopsy technique in the diagnosis of sarcomas. Biopsy access routes discussed with the surgeon, and skin access is tattooed. Surgery is a mainstay of sarcoma treatment; the resection can be large. Indeed, resection objective is R0 because quality of surgical margins impacts local control and survival. Radiotherapy is possible in neoadjuvant or in adjuvant treatment to improve local control rate. Recently radiotherapy enhancer injected percutaneously in soft tissue sarcoma has proven benefit in increasing the rate of R0 complete surgical resection. Several studies showed better local control rate linked with post-operative radiotherapy. In patients affected by oligometastatic disease, complete surgical resection of all metastatic sites is in fact considered the primary treatment because complete remission is critical for cure. The decision making to use local therapies is complex, depends upon diverse presentations and histologies, and should always be taken in a multidisciplinary discussion. Today, percutaneous image-guided treatments with ablation technologies (radiofrequency ablation, cryotherapy, microwaves ablation) provide high rate of durable local control for small-sized malignant deposit in many organs including lung, liver and bones. Sarcoma must be managed by multimodality treatment in expert reference centres. Such management has a considerable impact on the prognosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of phase-locking of optoelectronic microwave oscillators considering amplitude perturbation

This paper presents a detailed study of the phase-locking phenomenon in single-loop optoelectronic microwave oscillators considering strong radio frequency (RF) signal injection. The analyses are made in terms of the lock-range, beat frequency and the spectral components of the unlocked-driven oscillator in presence of amplitude perturbation. An approximate expression for the amplitude perturbation of the oscillator is derived and the influence of amplitude perturbation on the phase-locking dynamics is analysed. The influence of external RF signal on the frequency pulling of the unlocked-driven optoelectronic oscillator (OEO) is also studied. It is shown that the unlocked-driven OEO output signal has a very non-symmetrical sideband distribution about the carrier. Also, analytical technique for studying the response characteristics of a phase-locked OEO to pure continuous wave amplitude modulated signal is presented. The simulation findings are also given in partial support of the conclusions of the analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of long-term spatio-temporal radiofrequency electromagnetic field exposure

Highlights: • A year's worth of RF-EMF data is collected in an urban sensor network is analysed. • A full spatio-temporal model of the RF-EMF exposure in the study area is built. • Short-term variations of the RF-EMF exposure are collected in temporal profiles. • Models using data collected at different instants are improved by adjusting for time. As both the environment and telecommunications networks are inherently dynamic, our exposure to environmental radiofrequency (RF) electromagnetic fields (EMF) at an arbitrary location is not at all constant in time. In this study, more than a year's worth of measurement data collected in a fixed low-cost exposimeter network distributed over an urban environment was analysed and used to build, for the first time, a full spatio-temporal surrogate model of outdoor exposure to downlink Global System for Mobile Communications (GSM) and Universal Mobile Telecommunications System (UMTS) signals. Though no global trend was discovered over the measuring period, the difference in measured exposure between two instances could reach up to 42 dB (a factor 12,000 in power density). Furthermore, it was found that, taking into account the hour and day of the measurement, the accuracy of the surrogate model in the area under study was improved by up to 50% compared to models that neglect the daily temporal variability of the RF signals. However, further study is required to assess the extent to which the results obtained in the considered environment can be extrapolated to other geographic locations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Local Thermal Ablation with Continuous EGFR Tyrosine Kinase Inhibitors for EGFR-Mutant Non-small Cell Lung Cancers that Developed Extra-Central Nervous System (CNS) Oligoprogressive Disease

Background: Most epidermal growth factor receptor (EGFR)-mutant non-small cell lung cancer (NSCLC) patients treated with tyrosine kinase inhibitors (TKIs) experience oligoprogressive disease. Local ablation for isolated resistant sites continued with the original EGFR-TKI showed good efficacy in these patients. We conducted this multicenter retrospective study to investigate the potential benefit of thermal ablation in NSCLC patients that developed extra-central nervous system (CNS) oligoprogressive disease during TKI treatment. Methods: A total of 71 EGFR-mutant patients treated with EGFR-TKIs were identified. Progression-free survival 1 (PFS1) was calculated from the initiation of TKI treatment to first progression. Patients with metastatic sites ≤ 3 in less than 3 extra-CNS organs suitable for local ablation therapy received either radiofrequency ablation or microwave ablation to these sites and continued on the original TKIs. PFS2 was defined from the first progression to second progression after ablation. Results: The median PFS1 for all patients was 11.8 months. Eighty extra-CNS oligoprogressive lesions in 71 patients were ablated. Thirty-six of 71 patients progressed after thermal ablation and 31 of whom died during the study period. The median PFS2 after thermal ablation was 10.0 months, and the median overall survival was 26.4 months. PFS1 and PFS2 were highly correlated with OS, whereas PFS1 was not correlated with PFS2. The numbers of oligoprogressive lesions were significantly and independently associated with PFS2. Conclusion: Local thermal ablation for the oligoprogressive lesions with continuous EGFR-TKI treatment is associated with additional 10 months of disease control and should be recommended in TKI acquired resistant-NSCLC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wideband tunable up-converting optoelectronic oscillator based on gain–loss compensation technology and stimulated Brillouin scattering

An optically wideband tunable up-converting optoelectronic oscillator (OEO) based on stimulated Brillouin scattering and gain–loss compensation is demonstrated and theoretically analyzed. In the proposed structure, Brillouin narrowband filter technique is implemented by introducing two pump lights with the frequency interval twice the Brillouin frequency shift (v{sub b}). The overlapping of the gain and the loss spectrum is used to realize a wideband tunable OEO. As a consequence, the tunability of the wideband of the output microwave signal at f{sub m}+2v{sub b} from 22.4 to 61.4 GHz can be realized by changing the signal under testing from 1 to 40 GHz. In addition, the transfer function of the system is given and the single sideband (SSB) phase noise is also evaluated theoretically. And the theoretical simulated the SSB phase noise is − 116.1 dBc/Hz at the 10 kHz offset when the f{sub m} = 25 GHz. Not only the OEO can convert a low-frequency IF signal to a high-frequency signal without introducing any high-Q electrical filter, but the frequency of the output signal is high enough and widely tunable. Because of the high frequency tunable capacity, the up-converting OEO might have a potential application in radar communication and millimeter wave generation systems.

42 ENGINEERING↗

Near-Edge Soft X-ray Absorption Mass Spectrometry of Protonated Melittin

We have investigated the photoionization and photofragmentation yields of gas-phase multiply protonated melittin cations for photon energies at the K-shell absorption edges of carbon, nitrogen, and oxygen. Two similar experimental approaches were employed. In both experiments, mass selected [melittin+qH]{sup q+} (q=2–4) ions were accumulated in radiofrequency ion traps. The trap content was exposed to intense beams of monochromatic soft X-ray photons from synchrotron beamlines and photoproducts were analyzed by means of time-of-flight mass spectrometry. Mass spectra were recorded for fixed photon energies, and partial ion yield spectra were recorded as a function of photon energy. The combination of mass spectrometry and soft X-ray spectroscopy allows for a direct correlation of protein electronic structure with various photoionization channels. Non-dissociative single and double ionization are used as a reference. The contribution of both channels to various backbone scission channels is quantified and related to activation energies and protonation sites. Soft X-ray absorption mass spectrometry combines fast energy deposition with single and double ionization and could complement established activation techniques. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗