Vacuum radiometry of an infrared nanoantenna-coupled tunnel diode rectenna.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract In concentrated solar power (CSP) applications, fluidized bed is a promising approach for high heat transfer coefficient (HTC) solar receivers and heat exchangers. However, the complexity of multiphase mixing has made it difficult to characterize and analyze the heat transfer mechanism. This paper presents an experimental study on simultaneously characterizing heat transfer in both the near-wall and the bulk regions of a fluidized bed using modulated photothermal radiometry (MPR). The MPR is a non-contact frequency-domain technique using an intensity-modulated laser as the heat source and surface infrared emission as thermometry. The thermal penetration depth of the laser heating is varied by controlling its modulation frequency, and thus the measurement can resolve the near-wall and the bulk thermal resistances. With the MPR technique, we measured fluidized silica sands with a mean size of 164 μm in a vertical channel of 6 mm depth. Our results show that the near-wall thermal resistance is substantially increased with increasing gas velocity, which partially offsets the benefit of higher HTC brought by stronger particle mixing during the fluidization. We also used the MPR to quantify the improvement in particle-wall heat transfer in an inclined channel. We found that an 8° inclination towards the heat exchanging side led to a lower near-wall thermal resistance and a higher HTC at high gas velocities. This work demonstrates that the MPR technique is a useful tool to quantify the important near-wall thermal resistance from a bulk particle bed, which not only advances our understanding of heat transfer in fluidized beds, but may also contribute to the design of fluidized bed heat exchangers with higher HTC.
This paper details the first complete, DOE approved, deployed and operational radiometry for robotic nondestructive assay (NDA) of holdup deposits in gaseous diffusion piping. Some features, like peak-finding, Compton correction, detector efficiency, and material properties are characteristic of typical manual methods. Most features are specific to in-pipe robotic deployment. These include in-motion radiometry, self-determined location, geometric modeling of thick deposits, bounding of self-attenuation thickness and auto-checking of replicate measurements. Significant are the means for determining all the properties, equations, and constants for automatically computing and displaying all the quantities, uncertainties and information needed for NDA reporting, analysis, and review. Earlier work by this team demonstrated rudimentary but convincing robotic in-pipe NDA of holdup deposits in pipes. Cold testing with high-enrichment mat sources and hot tests with low U-235 loadings together succeeded to exhibit convincing proof-of-principle. This research-grade radiometry implementation lacked accurate odometry, efficiency calibration, high-fidelity detector modeling, attenuation modeling, forward geometric modeling, auto-segmenting, uncertainty modeling, replicate checking, deconvolution and much more. This work explains the technical basis behind robotic in-pipe NDA. It includes discussion of a new method for modeling of self-attenuation using in-pipe deposit geometry information, detail of the method's total measurement uncertainty, and explanation of calibration methods and results. Beyond development of automation-specific radiometric elements, the paper highlights analyses, testing, and technical bases specific to and supportive of the methodology. Examples include collimation characterization, detector efficiency determination, auto-calibration methodology, and odometric replicate-checking. Results of this methodology are formalized in a DOE EM Technical Basis Document, implemented in software, formally verified in review and acceptance testing and proceduralized as a means for D and D NDA at the Portsmouth enrichment facility. Measurement of U-235 quantity is a well-known cost and schedule driver in D and D of every defunct gaseous diffusion enrichment facility in the world. The radiometry methodologies and results detailed in this paper were the high hurdles. Having established the technical basis for this automated NDA, the opportunity is to apply this to many sizes and robot forms for addressing holdup deposit NDA throughout the D and D community. (authors)
Titanium thin films of different thicknesses were prepared by direct current magnetron sputtering to study modulated infrared (IR) radiometry as a tool for analyzing film thickness. Thickness was varied by regularly increasing the deposition time, keeping all the other deposition parameters constant. The influence of film thickness on morphological, structural, and electrical properties of the titanium coatings also was investigated. The experimental results revealed a systematic grain growth with increasing film thickness, along with enhanced film crystallinity, which led to increased electrical conductivity. Using the results obtained by modulated IR radiometry, the thickness of each thin film was calculated. These thickness values were then compared with the coating thickness measurements obtained by scanning electron microscopy. The values confirmed the reliability of modulated IR radiometry as an analysis tool for thin films and coatings, and for determining thicknesses in the micrometer range, in particular.
Purpose: Radiofrequency (RF) radiometry uses thermal noise detected by an antenna to measure the temperature of objects independent of medical imaging technologies such as magnetic resonance imaging (MRI). Here, an active interventional MRI antenna can be deployed as a RF radiometer to measure local heating, as a possible new method of monitoring device safety and thermal therapy. Methods: A 128 MHz radiometer receiver was fabricated to measure the RF noise voltage from an interventional 3 T MRI loopless antenna and calibrated for temperature in a uniformly heated bioanalogous gel phantom. Local heating (ΔT) was induced using the antenna for RF transmission and measured by RF radiometry, fiber-optic thermal sensors, and MRI thermometry. The spatial thermal sensitivity of the antenna radiometer was numerically computed using a method-of-moment electric field analyses. The gel’s thermal conductivity was measured by MRI thermometry, and the localized time-dependent ΔT distribution computed from the bioheat transfer equation and compared with radiometry measurements. A “H-factor” relating the 1 g-averaged ΔT to the radiometric temperature was introduced to estimate peak temperature rise in the antenna’s sensitive region. Results: The loopless antenna radiometer linearly tracked temperature inside a thermally equilibrated phantom up to 73 °C to within ±0.3 °C at a 2 Hz sample rate. Computed and MRI thermometric measures of peak ΔT agreed within 13%. The peak 1 g-average temperature was H = 1.36 ± 0.02 times higher than the radiometric temperature for any media with a thermal conductivity of 0.15–0.50 (W/m)/K, indicating that the radiometer can measure peak 1 g-averaged ΔT in physiologically relevant tissue within ±0.4 °C. Conclusions: Active internal MRI detectors can serve as RF radiometers at the MRI frequency to provide accurate independent measures of local and peak temperature without the artifacts that can accompany MRI thermometry or the extra space needed to accommodate alternative thermal transducers. A RF radiometer could be integrated in a MRI scanner to permit “self-monitoring” for assuring device safety and/or monitoring delivery of thermal therapy.
Here, an experimental methodology using photothermal radiometry is developed for the accurate measurement of bulk thermal diffusivity of nuclear fuels and materials irradiated to high doses. Under these conditions, nuclear fuels, such as uranium oxide, and moderator materials, such as graphite, become friable, which requires characterization techniques that can accommodate irregularly shaped fragments. Photothermal radiometry, a good candidate for this application, involves locally heating a sample by using a laser and measuring the temperature field by monitoring blackbody radiation. The interaction volume for this study, less than a millimeter, is carefully chosen to sample a statistically significant number of large-scale structural features, such as pores and gas filled bubbles, and is small enough that the sample fragments can be treated as a thermal half-space. The thermal diffusivity standards considered in this study cover a range of thermal diffusivities representative of both fresh and spent nuclear fuels. We also consider a sample having a porous microstructure representative of large-scale structures found in materials irradiated to high doses. Our measurement methodology circumvents complex thermal wave models that address optical diffraction, nonlinear transfer function associated with blackbody radiation, and finite sample size effects. Consequently, the large measurement uncertainty associated with modeling these effects can be avoided. While the emphasis here is on nuclear fuels and materials, this measurement approach is well suited to measure thermal transport in a variety of technologically important materials associated with advanced synthesis techniques. Examples range from small, exotic single crystals grown using hydrothermal growth techniques to additively manufactured components having complex geometries.
COMPASS tokamak has started its operation in IPP Prague recently. A new 16-channel radiometry system has been designed and manufactured for the electron Bernstein/cyclotron wave emission (EBE/ECE) experiments. For EBE studies, based on EBW-X-O mode conversion, radiometry in Ka-band (26.5-40 GHz will be used which corresponds to the fundamental EC harmonics for the low-B{sub t}(B{sub o}{approx}1.2 T) tokamak operation. Alternatively, an E-band antenna and front-end (60-73.5/76.5-90 GHz) will be used with the same 16-channel receiver for the conventional second harmonics ECE diagnostics. In the contribution the design of the system is described as well as the initial testing measurements on tokamak COMPASS.
This paper presents the development of instrumentation for the measurement of high-temperature thermal conductivity of bulk and coatings using a modulated photothermal radiometry (MPR) method, where a sample is heated by an intensity-modulated laser to probe into different layers of the sample. While MPR has been previously established, most of the previous studies only focus on the measurement at room temperature. The MPR has not been well studied for measurements of bulk and coating materials at high temperatures, which are increasingly important for a multitude of applications, such as materials used in the concentrating solar power (CSP) plants and the nuclear reactors. MPR is a non-contact technique that utilizes the intrinsic thermal emission from the specimens for thermometry, which is favorable for measurements at high temperatures in harsh environment. The authors designed and utilized a sample holder suitable for high temperature measurement up to 973 K with good temperature uniformity within the sample. The high-temperature MPR setup was validated by measuring bulk materials with known thermal conductivity. The setup and technique were then extended to the measurement of black solar-absorbing coatings of 10 to 50 μm thick on various substrates by modulating the frequency of the laser heating beam and the thermal penetration depth. Here, the studies showed that thermal conductivities of typical solar-absorbing coatings are 0.4 ~ 0.8 W m -1 K -1 , indicating a possibly large temperature drop within the coating under high solar irradiation flux, such as over 1000-sun for central solar towers in CSP plants.
In situ thermal transport measurement of flowing fluid could be useful for the characterization and diagnosis of practical thermal systems such as fluid heat exchangers and thermal energy storage systems. Despite abundant reports on the ex-situ thermal conductivity measurement of stagnant fluids, a suitable technique for the thermal conductivity measurement of flowing fluid has been rarely reported. Here, this paper presents the thermal conductivity measurement of flowing fluid within a pipe using a non-contact modulated photothermal radiometry (MPR) technique, where the surface of the pipe is heated by an intensity-modulated laser and the heat diffuses into the fluid with suitable modulation frequency. We design a tube section with small wall thickness suitable for the MPR measurements to maximize the sensitivity of the thermal response to the fluid properties while minimizing the lateral heat spreading effect. Intrinsic thermal conductivity of different fluids was obtained within a proper range of frequency and flow velocity where the forced convection effect is negligible. The forced convection effect became prominent at high flowing velocity and at low modulation frequency, leading to higher effective thermal conductivity of the fluid. It is found that the intrinsic thermal conductivity could be obtained when the flow velocity is less than 100 mm/sec and Re D 1/2 Pr 1/3 < 100 for DI water and Xceltherm oil under the specified experimental conditions, where Re D is the Reynolds number and Pr is the Prandtl number.
Molten salts are being used or explored for thermal energy storage and conversion systems in concentrating solar power and nuclear power plants. Thermal conductivity of molten salts is an important thermophysical property dictating the performance and cost of these systems, but its accurate measurement has been challenging, as evidenced by wide scattering of existing data in literature. The corrosive and conducting nature of these fluids also leads to time consuming sample preparation processes of many contact-based measurements. Here, in this work, we report the measurement of thermal conductivity of molten salts using a modulated photothermal radiometry (MPR) technique, which is a laser-based, non-contact, frequency-domain method adopted for molten salts for the first time. By unitizing the advantages of front side sensing of frequency-domain measurements and the vertical holder orientation, the technique can minimize the natural convection and salt creeping effects, thus yielding accurate molten salt thermal conductivity . The MPR technique is first calibrated using standard molten materials including paraffin wax and sulfur. It is then applied on measuring pure nitrate salts (NaNO 3 and KNO 3 ), solar salt (NaNO 3 –KNO 3 mixture), and chloride salt (NaCl–KCl–MgCl 2 ). The measurement results are compared with data from literature, especially those obtained from laser flash analysis (LFA). Our results demonstrate that the MPR is a convenient and reliable technique of measuring thermal conductivity of molten salts. Accurate thermal conductivity data of molten salts will be valuable in developing the next-generation high-temperature thermal energy storage and conversion systems.
Millimeter wave (MMW) radiometry can be used for simultaneous measurement of emissivity and temperature of materials under extreme environments (high temperature, pressure, and corrosive environments). The state-of-the-art dual channel MMW passive radiometer with active interferometric capabilities at 137 GHz described here allows for radiometric measurements of sample temperature and emissivity up to at least 1600 °C with simultaneous measurement of sample surface dynamics. These capabilities have been used to demonstrate dynamic measurement of melting of powders of simulated lunar regolith and static measurement of emissivity of solid samples. The paper presents the theoretical background and basis for the dual-receiver system, describes the hardware in detail, and demonstrates the data analysis. Post-experiment analysis of emissivity versus temperature allows further extraction from the radiometric data of millimeter wave viewing beam coupling factors, which provide corroboratory evidence to the interferometric data of the process dynamics observed. Finally, these results show the promise of the MMW system for extracting quantitative and qualitative process parameters for industrial processes and access to real-time dynamics of materials behavior in extreme environments.
Flexible printed electronics is a rapidly growing field with applications in conformal and flexible devices. However, the physical properties of the films created by many state-of-the-art printing methods become highly dependent on printing parameters, resulting in varying thermal properties often differing significantly from their bulk ink components. To understand the influence of the printing process, we build upon our previous work, where a noncontact optical technique, known as modulated photothermal radiometry (MPTR), was used to measure the thermal conductivity of aerosol-jet-printed thin films. In this work, we use the method to study the thermal properties of extrusion-printed silver on glass and alumina substrates. A noise-resistant data analysis fitting technique is applied using a 2-D heat transfer model. Here, the thermal conductivity measurement is validated using the Weidemann-Franz (WF) relationship from measured electrical conductivity values.
This presentation provides an overview of the recent updates to the international standards on radiometry.
The statistical analysis of historic pressure and temperature profiles from radiosonde launches for use in the fitting of molecular oxygen line shapes is presented. As the O 2 mixing ratio is nearly constant throughout the lower atmosphere, only variations in pressure and temperature profiles will affect the fit of observed O 2 features in Laser Heterodyne Radiometry (LHR) spectra. Radiosonde temperature and pressure data are extracted from the Integrated Global Radiosonde Archive (IGRA) for a given station, date, and launch time. Data may be extracted for a single launch, for the same date over several years, and/or within a window centered on a target date. The temperature and pressure profiles are further characterized by the statistical variation in coefficients of polynomial fits in altitude. The properties of the probability distributions for each coefficient are used to constrain fits of O 2 line shapes through Nelder–Mead optimization. The refined temperature and pressure profiles are then used in the retrieval of vertically resolved mixing ratios for greenhouse gases (GHGs) measured in the same instrument. In continuous collections, each vertical profile determination may be treated as a Bayesian prior to inform subsequent measurements and provide an estimate of uncertainties.
In this review, the emerging work using a technique known as modulated photothermal radiometry (MPTR) is evaluated. As MPTR has matured, the previous discussions on theory and modeling have become increasingly limited in their applicability to the current state of the art. After a brief history of the technique, the currently used thermodynamic theory is explained, highlighting the commonly applied simplifications. The validity of the simplifications is explored via modeling. Various experimental designs are compared, and the differences are explored. New applications, as well as emerging analysis techniques, are presented to emphasize the trajectory of MPTR.
Thermal transport properties such as thermal conductivity and diffusivity, are critical parameters in the development of improved nuclear fuels and components. It is well known that thermal transport properties change temporally and spatially due to dynamic microstructural evolution as a result of neutron irradiation. Laser based photothermal techniques are an ideal candidate for thermal properties measurement of irradiated materials because they are non contact, non destructive and can be performed remotely. In this report, we present the progress in the development of a photothermal radiometry (PTR) system to measure the thermal diffusivity of solid samples. The PTR technique measures the local temperature response from a modulated heat source by detecting the sample radiation heat flux. Initially, a well developed thermal wave analytical model was fit to the data to obtain the thermal diffusivity. However, systematic errors from the diffraction effect and non linearity issues resulted in thermal diffusivity measurements higher than literature values. These effects have been studied, an improved analytical model has been developed, and the physics behind the phenomena are still under investigation. A procedure for optimizing measurements from the benchtop system has been provided.
Thermal transport properties of nuclear fuels, i.e., thermal conductivity and diffusivity, are critical parameters in the thermal design of a nuclear reactor. It is well known that thermal transport properties change temporally and spatially due to dynamic microstructural evolution as a result of neutron irradiation. A real-time instrument to monitor the local thermal property change, which can survive the harsh in-pile environment, will give researchers unprecedented access to fuel behavior during irradiation. Laser-based photothermal techniques are an ideal candidate to accomplish this specific task, because of the remote, non-contact, and non-destructive features. In this report, we present the progress in the development of a bench-top photothermal radiometry (PTR) system to measure the thermal diffusivity of solid samples, and the preliminary design of a fiber-based PTR instrument to measure the real-time, in-pile thermal diffusivity of nuclear fuels. The PTR technique measures the local temperature response from a modulated heat source by detecting the sample radiation heat flux. Initially a well-developed thermal wave analytical model was fit to the data to obtain the thermal diffusivity. However, systematic errors from the diffraction effect and non-linearity issues resulted in thermal diffusivity measurements higher than literature values. These effects have been studied and an improved analytical model has been developed, and the physics behind the phenomena are still under investigation. A procedure for optimizing measurements from the bench-top system has been provided. The experiences from the bench top measurement were then used to guide the fiber-based system.
This report documents FY20 progress in the development of a benchtop photothermal radiometry (PTR) instrument for the measurement of thermal diffusivity. A PTR system incorporating Off-Axis Parabolic (OAP) mirrors was designed and tested. Additionally, a novel analysis technique that accounts for systematic errors that affect measurement accuracy was implemented. Measurements on samples with a range of thermal diffusivities using the PTR setup along with the new analysis technique resulted in improved accuracy and repeatability. Areas for future development work are set forth.