Engineering PapersSearch

SEARCH · Engineering Papers

Results for “RADIOBIOLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Updated Results of the Nuclear Accident Dosimetry Intercomparison at the Armed Forces Radiobiology Research Institute’s TRIGA Reactor (IER-602 CED-4a Report)

The IER-602 3b document (Angus, et al. 2024) reported the initial, 24-hour results of the international nuclear accident intercomparison, which took place at the Armed Forces Radiobiological Research Institute during June 24-28, 2024. This report provides updated results and further analysis of the intercomparison.

61 RADIATION PROTECTION AND DOSIMETRY

Initial Results of the Nuclear Accident Dosimetry Intercomparison at the Armed Forces Radiobiology Research Institute's TRIGA Reactor

This report presents the initial results for IER-602, the international nuclear accident dosimetry intercomparison performed at the Armed Forces Radiobiology Research Institute (AFRRI). Ten groups participated (six DOE laboratories, three international groups, and one DOD group) in a week-long exercise in late June 2024. Two additional groups observed the exercise (one DOE laboratory, one university). Three days of irradiations were performed, and participants reported results within 24 hours of the irradiations. Results were compared to the reference values and performance criteria established by IER-484 AFRRI ER1 Dosimetry Characterization and ANSI/HPS N13.3-2013, respectively. Passing performance varied from 17% to 100%, with an average of 67%.

61 RADIATION PROTECTION AND DOSIMETRY

On the Necessity of Adopting Irradiation Protocols Recommended by the Compatibility in Irradiation Research Protocols Expert Roundtable (CIRPER) in Published Research and Why It Matters to Health Physicists

The National Nuclear Security Administration (NNSA) seeks to assist and support all partners in the fields of radiobiology, health physics, radiation physics, and related areas to transition from cesium-137 chloride-based technologies that can potentially be used in an act of terrorism to X-ray technologies. The absence of information on experimental procedures, equipment, and irradiation parameters directly and negatively impacts the reproducibility and translatability of a sizable portion of radiation biology studies. It also discourages researchers from adopting new tools that eliminate the risks of a radiological dispersal device.

Stern, Warren [Brookhaven National Laboratory (BNL

Non-DNA radiosensitive targets that initiate persistent behavioral deficits in rats exposed to space radiation

Predicting future CNS risks for astronauts during deep-space missions will rely substantially on ground-based rodent data with space-relevant ions and behaviors. For rats, the accumulated evidence indicates that less densely ionizing radiation, such as 4 He and 12 C ions, induce behavior deficits at lower doses than densely ionizing ions, such as 48 Ti and 56 Fe. However, this observation conflicts with standard somatic radiobiology, in which densely ionizing ions are generally more effective than less densely ionizing ions, and where the DNA/nucleus is the accepted target for radiation-induced tumorigenesis, cytogenetic aberrations, genetic mutations, and reproductive cell death. To gain deeper insight into the subcellular nature of the radiation targets for behavior risks, we compared the effects of dose, fluence, and linear energy transfer (LET) of 4 He and 56 Fe particles using existing datasets for four distinct behavioral outcomes in rats: elevated plus maze (EPM-anxiety), novel object recognition (NOR-memory), operant responding (OR-response to environmental stimuli), and attentional set-shifting (ATSET-cognitive flexibility). We confirmed that less densely ionizing particles (except protons) showed ~100-fold lower threshold doses than densely ionizing particles for behavioral deficits (0.1–1 cGy for 4 He vs. 15–100 cGy for 56 Fe). However, when analyzed by fluence the behavioral responses converged, indicating that 4 He and 56 Fe were equally effective on a per-track basis. When analyzed by LET, there were ~100-fold differences in the LET for maximum effectiveness for behavioral deficits and DNA endpoints (~1 vs ~100 keV/μm, respectively). These unique features of radiation-induced behavioral deficits (high sensitivity to particles in the 1-keV/μm range, insensitivity to protons in the 0.2 keV/μm range, and isofluence dependence for particles with LET>1 keV/μm) provide evidence in support of a new hypothesis of sub-micron sized radiosensitive targets for behavioral effects consistent with the thickness of plasma membranes and/or small subcellular structures, smaller than a whole synapse. Like our behavior findings, mouse immature oocyte killing which is known to have a plasma membrane target was also better explained by fluence, rather than dose. In contrast, fluence analyses for DNA/nuclear endpoints in somatic cells (e.g., tumor induction, chromosome aberrations) showed opposite results, suggesting that behavior targets are not DNA. Our findings raise questions regarding the identity of subcellular targets and the multi-cellular functional unit for behavior risks, low-dose susceptibility, and generalizability from rat to other species and astronauts.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN

Integrating chromosome conformation and DNA repair in a computational framework to assess cell radiosensitivity

Objective. The arrangement of chromosomes in the cell nucleus has implications for cell radiosensitivity. The development of new tools to utilize Hi-C chromosome conformation data in nanoscale radiation track structure simulations allows for in silico investigation of this phenomenon. We have developed a framework employing Hi-C-based cell nucleus models in Monte Carlo radiation simulations, in conjunction with mechanistic models of DNA repair, to predict not only the initial radiation-induced DNA damage, but also the repair outcomes resulting from this damage, allowing us to investigate the role chromosome conformation plays in the biological outcome of radiation exposure. Approach. In this study, we used this framework to generate cell nucleus models based on Hi-C data from fibroblast and lymphoblastoid cells and explore the effects of cell type-specific chromosome structure on radiation response. The models were used to simulate external beam irradiation including DNA damage and subsequent DNA repair. The kinetics of the simulated DNA repair were compared with previous results. Main results. We found that the fibroblast models resulted in a higher rate of inter-chromosome misrepair than the lymphoblastoid model, despite having similar amounts of initial DNA damage and total misrepairs for each irradiation scenario. Significance. This framework represents a step forward in radiobiological modeling and simulation allowing for more realistic investigation of radiosensitivity in different types of cells.

59 BASIC BIOLOGICAL SCIENCES

EM Physics

Geant4 provides a comprehensive set of electromagnetic (EM) processes and models for electron/positron, gamma and long-lived charged particles, spanning energies from 100 eV to 100 TeV. Covering diverse energy regions often requires multiple models, which can be constructed using pre-packaged or user-defined EM physics constructors. Geant4 also supports detailed low-energy EM physics through models like Livermore, Penelope, and ICRU73, offering extensive data for elements across a wide energy range (250 eV–100 GeV). Application domains include space, medical, and radiobiology simulations. Additionally, Geant4 provides robust options for simulating complex optical photon production and transportation processes, enhancing its versatility in physics research and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Reevaluation of Radiation-Protection Standards for Workers and the Public Based on Current Scientific Evidence

President Trump’s recent executive orders to “Usher in a Nuclear Renaissance,” coupled with the global pledge to triple nuclear energy capacity by 2050, underscore nuclear energy’s importance to national security and economic prosperity. This renewed interest has prompted efforts to spur nuclear-energy deployment, including assessing factors impeding it. One issue that has previously been identified as adding to the cost of nuclear energy is excessively conservative requirements, including those related to radiation protection. This technical review, therefore, examines current radiation-protection standards that were established decades ago when more limited data were available and nuclear-energy expansion was not a national priority. The review focuses on scientific evidence regarding the health effects of ionizing radiation at annual doses of 10,000 mrem or less. The review evaluates epidemiological studies, radiobiological research, and positions of relevant professional organizations to assess whether such doses result in discernable or observable increases in negative health outcomes. The review also surveys the literature related to economic and practical implications of current radiation-protection standards and practices. Based on this assessment, we propose maintaining an annual occupational whole-body dose limit of 5,000 mrem/yr and eliminating all “as low as reasonably achievable” requirements and limits below this threshold. This change could potentially reduce radiation-protection costs by millions of dollars annually for each reactor, as well as decrease the overall costs and correct misconceptions about the risks associated with all nuclear technologies. The evidence further supports future consideration of a 10,000 mrem/yr limit that would maintain appropriate safety margins while further reducing protection costs. Similarly, given the data and that the average annual radiation dose per person in the U.S. is 620 mrem, we believe the public dose limits of 100 mrem/yr are unnecessarily restrictive; increasing to 500 mrem/yr would maintain substantial safety margins—a factor of 10 below the occupational limit—while reducing regulatory burdens and associated bureaucracy. While we acknowledge ongoing scientific debate and encourage continued research on the health effects of ionizing radiation, our review indicates current frameworks are overly conservative. These overly stringent limits not only impose unnecessary economic burdens without corresponding health benefits but also divert safety focus and resources from more important considerations. Although this study was motivated by nuclear-power considerations, reforms to radiation-protection requirements have significant positive implications for other areas, such as nuclear medical applications, environmental remediation, nuclear-waste management and disposal, and industrial applications of nuclear technologies.

61 RADIATION PROTECTION AND DOSIMETRY

Logistics for the 2026 International Nuclear Accident Dosimetry Intercomparison Exercise

The purpose of this exercise is to test participants’ nuclear accident dosimeters (NADs) and personnel to the requirements established by American National Standards Institute (ANSI), Health Physics Society (HPS) standard ANSI/HPS-N13.3-2013 (R2025) Dosimetry for Criticality Accidents. IER-634 is the second nuclear accident dosimetry exercise taking place at the Armed Forces Radiobiology Research Institute (AFRRI) in Bethesda, MD, a Department of Defense (DOD) facility. This effort continues use of the high-dose neutron exposure test bed maintained by the DOD and represents the continued collaboration between the DOD and Department of Energy (DOE). Previous work at AFRRI included a reactor characterization (IER 484) in 2023 and a nuclear accident intercomparison exercise (IER-602) in 2024.

61 RADIATION PROTECTION AND DOSIMETRY

Thermal Performance of Neutron Sensor Qualification Device

The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND