Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SU-C-16A-06: Optimum Radiation Source for Radiation Therapy of Skin Cancer

Purpose: Recently, different applicators are designed for treatment of the skin cancer such as scalp and legs, using Ir-192 HDR Brachytherapy Sources (IR-HDRS), Miniature Electronic Brachytherapy Sources (MEBXS), and External Electron Beam Radiation Therapy (EEBRT). Although, all of these methodologies may deliver the desired radiation dose to the skin, the dose to the underlying bone may become the limiting factor for selection of the optimum treatment technique. In this project the radiation dose delivered to the underlying bone has been evaluated as a function of the radiation source and thickness of the underlying bone. Methods: MC simulations were performed using MCNP5 code. In these simulations, the mono-energetic and non-divergent photon beams of 30 keV, 50 keV, and 70 keV for MEBXS, 380 keV photons for IR-HDRS, and 6 MeV mono-energetic electron beam for EEBRT were modeled. A 0.5 cm thick soft tissue (0.3 cm skin and 0.2 cm adipose) with underlying 0.5 cm cortical bone followed by 14 cm soft tissue are utilized for simulations. Results: Dose values to bone tissue as a function of beam energy and beam type, for a delivery of 5000 cGy dose to skin, were compared. These results indicate that for delivery of 5000 cGy dose to the skin surface with 30 keV, 50 keV, 70 keV of MEBXS, IR-HDRS, and EEBRT techniques, bone will receive 31750 cGy, 27450 cGy, 18550 cGy, 4875 cGy, and 10450 cGy, respectively. Conclusion: The results of these investigations indicate that, for delivery of the same skin dose, average doses received by the underlying bone are 5.2 and 2.2 times larger with a 50 keV MEBXS and EEBRT techniques than IR-HDRS, respectively.

07 ISOTOPE AND RADIATION SOURCES↗

An oil-free compact X-pinch plasma radiation source: Design and radiation performance

This paper describes a new, high-current, X-pinch radiation source recently developed and tested at Idaho State University. Our design is based on two linear transformer driver (LTD) bricks arranged in side-by-side geometry and directly coupled with an X-pinch load. The salient features of our 2-LTD-bricks are its simplicity, compactness, and portability: there is no oil, no water, and no SF6. It can be easily relocated to any place where a compact X-pinch radiation source is wanted. The driver can store up to 2.8 kJ of initial energy and can deliver more than 200-kA peak-current with less than 200-ns, 10%-90%, rise time into a short-circuit load. When the driver is coupled with an X-pinch load, it generates a very fast and bright radiation pulse. Source size measurements indicate that this radiation originates from a very small dense plasma, known as a “hot spot.”

Shapovalov, Roman V.↗

A source-attractor approach to network detection of radiation sources

Radiation source detection using a network of detectors is an active field of research for homeland security and defense applications. We propose Source-attractor Radiation Detection (SRD) method to aggregate measurements from a network of detectors for radiation source detection. SRD method models a potential radiation source as a magnet -like attractor that pulls in pre-computed virtual points from the detector locations. A detection decision is made if a sufficient level of attraction, quantified by the increase in the clustering of the shifted virtual points, is observed. Compared with traditional methods, SRD has the following advantages: i) it does not require an accurate estimate of the source location from limited and noise-corrupted sensor readings, unlike the localizationbased methods, and ii) its virtual point shifting and clustering calculation involve simple arithmetic operations based on the number of detectors, avoiding the high computational complexity of grid-based likelihood estimation methods. We evaluate its detection performance using canonical datasets from Domestic Nuclear Detection Office s (DNDO) Intelligence Radiation Sensors Systems (IRSS) tests. SRD achieves both lower false alarm rate and false negative rate compared to three existing algorithms for network source detection.

Wu, Qishi↗

Tunable terahertz radiation source

Terahertz radiation source and method of producing terahertz radiation, said source comprising a junction stack, said junction stack comprising a crystalline material comprising a plurality of self-synchronized intrinsic Josephson junctions; an electrically conductive material in contact with two opposing sides of said crystalline material; and a substrate layer disposed upon at least a portion of both the crystalline material and the electrically-conductive material, wherein the crystalline material has a c-axis which is parallel to the substrate layer, and wherein the source emits at least 1 mW of power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Source Localization Using Surrogate Models Constructed from 3-D Monte Carlo Transport Physics Simulations

Recent research has focused on the development of surrogate models for radiation source localization in a simulated urban domain. We employ the Monte Carlo N-Particle (MCNP) code to provide high- delity simulations of radiation transport within an urban domain. The model is constructed to employ a source location (x, y, z) as input and return the estimated count rate for a set of speci ed detector locations. Because MCNP simulations are computationally expensive, we develop e cient and accurate surrogate models of the detector responses. We construct surrogate models using Gaussian processes (GP) and neural networks (NN) that we train and verify using the MCNP simulations. The trained surrogate models provide an e cient framework for Bayesian inference and experimental design. We employ Delayed Rejection Adaptive Metropolis (DRAM), a Markov Chain Monte Carlo (MCMC) algorithm, to infer the location and intensity of an unknown source. The DRAM results yield a posterior probability distribution for the source's location conditioned on the observed detector count rates. The posterior distribution exhibits regions of high and low probability within the simulated environment identifying potential source locations. In this manner, we can quantify the source location to within at least one of these regions of high probability in the considered cases. Employing these methods, we are able to reduce the space of potential source locations by at least 60%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Double Q-Learning for Radiation Source Detection

Anomalous radiation source detection in urban environments is challenging due to the complex nature of background radiation. When a suspicious area is determined, a radiation survey is usually carried out to search for anomalous radiation sources. To locate the source with high accuracy and in a short time, different survey approaches have been studied such as scanning the area with fixed survey paths and data-driven approaches that update the survey path on the fly with newly acquired measurements. In this work, we propose reinforcement learning as a data-driven approach to conduct radiation detection tasks with no human intervention. A simulated radiation environment is constructed, and a convolutional neural network-based double Q-learning algorithm is built and tested for radiation source detection tasks. Simulation results show that the double Q-learning algorithm can reliably navigate the detector and reduce the searching time by at least 44% compared with traditional uniform search methods and gradient search methods.

36 MATERIALS SCIENCE↗

Network Detection of Radiation Sources Using Localization-Based Approaches

Radiation source detection is a critical problem in homeland security-related applications. Deploying a network of detectors is expected to provide improved detection due to the combined, albeit dispersed, capture area of multiple detectors. Recently, localization-based detection algorithms provided performance gains beyond the simple “aggregated” area as a result of localization being enabled by the networked detectors. We introduce the following three localization-based detection approaches: 1) source-attractor radiation detection (SRD); 2) triangulation-based radiation source detection (TriRSD); and 3) the ratio of square distance-based radiation source detection (ROSD-RSD). We use canonical datasets from Domestic Nuclear Detection Office's intelligence radiation sensors systems tests to assess the performance of these methods. Extensive results demonstrate that SRD outperforms TriRSD and ROSD-RSD, and other existing detection algorithms based on the sequential probability ratio test and maximum likelihood estimation in terms of both false alarm and detection rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic mirror cavities as terahertz radiation sources and a means of quantifying radiation friction

We propose a radiation source based on a magnetic mirror cavity. Relativistic electrons are simulated entering the cavity and their trajectories and resulting emission spectra are calculated. The uniformity of the particle orbits is found to result in a frequency comb in terahertz range, the precise energies of which are tunable by varying the electron's γ-factor. For very high energy particles, radiation friction causes the spectral harmonics to broaden and we suggest this as a possible way to verify competing classical equations of motion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Device and method for the location and identification of a radiation source

A handheld device for the location and identification of a radiation source, including: a radiation transparent housing; a radiation locator device disposed within the radiation transparent housing operable for determining the location of the radiation source, wherein the radiation locator device includes a plurality of gamma detection crystals arranged in a geometric pattern and separated by a gamma shielding material, a plurality of detectors coupled to the plurality of gamma detection crystals, and a processor module coupled to the plurality of detectors; one or more of a neutron detection crystal and a gamma spectroscopy crystal disposed within the radiation transparent housing adjacent to the radiation locator device; and one or more detectors coupled to the one or more of the neutron detection crystal and the gamma spectroscopy crystal and the processor module; wherein the one or more of the neutron detection crystal and the gamma spectroscopy crystal, the one or more detectors, and the processor module are collectively operable for identifying the radiation source.

Vencelj, Matjaz↗

Indirect detection of radiation sources through direct detection of radiolysis products

A system for indirectly detecting a radiation source by directly detecting radiolytic products. The radiation source emits radiation and the radiation produces the radiolytic products. A fluid is positioned to receive the radiation from the radiation source. When the fluid is irradiated, radiolytic products are produced. By directly detecting the radiolytic products, the radiation source is detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of an image jitter of an extended incoherent radiation source

A scheme of an image jitter measuring device, which uses an extended incoherent source as a radiation source, is presented. The efficiency of the measuring device is analysed analytically and numerically in order to justify the operation of the adaptive optical system that does not require special creation or formation of a reference source. The features of the formed image of incoherent radiation are considered, in particular from the point of view of its possible application for measuring the phase fluctuations of optical waves propagating in a turbulent atmosphere (the adaptive system monitors the image of a self-luminous object illuminated by extraneous sources). The possibility of utilising a Shack – Hartmann wavefront sensor in adaptive systems using the image of an arbitrary object (or its fragment) as a reference source is shown. (optical images)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total Residual Radiation Source Term Produced by the Hiroshima Detonation

Residual radiation from a nuclear detonation consists of fission products and activation products produced by the excess neutrons released during the explosion. The ability to accurately predict nuclear fallout begins with a calculation of the residual radiation source term. The intent of this paper is to define the residual radiation source term for the Hiroshima detonation. The calculation was performed using the Livermore Weapon Activation Code (LWAC), which is a simplified three-region model that estimates the residual radiation associated with the fission products, the unburnt fuel, and activation products produced in the weapon components, the surrounding air, and the ground in the vicinity of ground zero. For the Hiroshima detonation, ~1200 radionuclides were produced. A time-dependent solution for the total activity of each of the major residual radiation source terms is provided in the Appendices. In addition, the timedependent exposure rates produced by the activation rings are included in the report.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Design and experimental study of a secondary hohlraum radiation source with laser focal spots blocked

A design of secondary hohlraum radiation source with laser focal spots blocked is introduced. The hard x-ray radiation such as the gold M-band emission and hot electrons from the coronal plasma were designed to be shielded using a cylindrical shield. Three-dimensional view factor analysis was carried out to optimize the shield structure to achieve higher radiation temperature. An experiment was performed at Shenguang III prototype laser facility to verify the design. Velocity Interferometer System for Any Reflector was used to measure the shock wave speed in a three-stepped Al sample driven by this radiation source and the peak radiation temperature of the radiation source was estimated to be about 90 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Seeding Coherent Radiation Sources with Sawtooth Modulation

Seed radiation sources have the ability to increase longitudinal coherence, decrease saturation lengths, and improve performance of tapering, polarization control and other FEL features. Typically, seeding schemes start with a simple sinusoidal modulation, which is manipulated to provide bunching at a high harmonic of the original wavelength. In this paper, we consider seeding from sawtooth modulations. The sawtooth creates a clean phase space structure, providing a maximal bunching factor without the need for an FEL interaction. While a pure sawtooth modulation is a theoretical construct, it is possible to approach the waveform by combining two or more of the composite wavelengths. We give examples of sawtooth seeding for HGHG, EEHG and other schemes, and note that the sawtooth modulation may aid in suppression of the microbunching instability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation Source Replacement Workshop

This report summarizes a Radiation Source Replacement Workshop in Houston Texas on October 27-28, 2010, which provided a forum for industry and researchers to exchange information and to discuss the issues relating to replacement of AmBe, and potentially other isotope sources used in well logging.

07 ISOTOPE AND RADIATION SOURCES↗

457-nm radiation source based on a diode laser for precision spectroscopy of magnesium atoms

We report on the development of a highly stable source of 457-nm radiation based on a diode laser and a tapered amplifier operating in a double-pass scheme. The diode laser frequency was stabilised by a high-Q reference Fabry – Perot interferometer and doubled in a PPSLT nonlinear crystal placed in an enhancement cavity. At a maximum output power of 200 mW at a wavelength of 457 nm, the laser linewidth was less than 5 kHz. The radiation source operation was demonstrated in experiments on precision spectroscopy of cold magnesium atoms in a magneto-optical trap. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗