At least 19 records

Medium-Scale Methanol Pool Fire Model Validation

In this work, medium scale (30 cm diameter) methanol pool fires were simulated using the latest fire modeling suite implemented in Sierra/Fuego, a low Mach number multiphysics reacting flow code. The sensitivity of model outputs to various model parameters was studied with the objective of providing model validation. This work also assesses model performance relative to other recently published large eddy simulations (LES) of the same validation case. Two pool surface boundary conditions were simulated. The first was a prescribed fuel mass flux and the second used an algorithm to predict mass flux based on a mass and energy balance at the fuel surface. Gray gas radiation model parameters (absorption coefficients and gas radiation sources) were varied to assess radiant heat losses to the surroundings and pool surface. The radiation model was calibrated by comparing the simulated radiant fraction of the plume to experimental data. The effects of mesh resolution were also quantified starting with a grid resolution representative of engineering type fire calculations and then uniformly refining that mesh in the plume region. Simulation data were compared to experimental data collected at the University of Waterloo and the National Institute of Standards and Technology (NIST). Validation data included plume temperature, radial and axial velocities, velocity temperature turbulent correlations, velocity velocity turbulent correlations, radiant and convective heat fluxes to the pool surface, and plume radiant fraction. Additional analyses were performed in the pool boundary layer to assess simulated flame anchoring and the effect on convective heat fluxes. This work assesses the capability of the latest Fuego physics and chemistry model suite and provides additional insight into pool fire modeling for nonluminous, non-sooting flames.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Highly silanized cellulose biocomposites for sustainable insulation materials

Microfibrillated lignocellulose networks, derived from agricultural byproducts, represent an environmentally friendly biogenic material production due to their abundant availability to circular bioeconomy and inherent carbon sink in life cycle analysis. Yet, its vulnerability to moisture and flammability, coupled with challenges in creating highly reinforced insulation materials, poses challenges for the carbon-zero green building sector. Here we address these challenges with a new concept of in-situ grafting polymerization of nanoporous silica in pre-formed lignocellulosic fiber networks. The seamlessly integrating nanoporous silica with cellulose through hydrogen bonding networks enabled us to prepare highly reinforced biogenic composites for green building insulations. A high reinforcement biocomposite with hierarchal arrangements of nanoporous silica within the cellulose network exhibits remarkable attributes. It boasts a thermal conductivity of 24.2 mW·m –1 ·K –1 , a flexural modulus of 942 MPa, and soundproofing with a 20.8 % noise reduction, as well as the fire resistance characterized by an extended time to ignition and a reduced peak heat release rate of 144 kW·m –2 at 35 kW·m –2 of incident radiant heat flux. Furthermore, it demonstrates a reduced water absorption capacity, dropping from 5.12 g·g –1 to 0.75 g·g –1 . Altogether, this study opens the new pathways towards sustainable carbon-zero building materials in the context of circular bioeconomy.

36 MATERIALS SCIENCE↗

Modeling Thermal Interactions between Buildings in an Urban Context

Thermal interactions through longwave radiation exchange between buildings, especially in a dense urban environment, can strongly influence a building’s energy use and environmental impact. However, these interactions are either neglected or oversimplified in urban building energy modeling. We developed a new feature in EnergyPlus to explicitly consider this term in the surface heat balance calculations and developed an algorithm to batch calculating the surrounding surfaces’ view factors using a ray-tracing technique. We conducted a case study with a district in the Chicago downtown area to evaluate the longwave radiant heat exchange effects between urban buildings. Results show that the impact of the longwave radiant effects on annual energy use ranges from 0.1% to 3.3% increase for cooling and 0.3% to 3.6% decrease for heating, varying among individual buildings. At the district level, the total energy demand increases by 1.39% for cooling and decreases 0.45% for heating. We also observe the longwave radiation can increase the exterior surface temperature by up to 10 °C for certain exterior surfaces. These findings justify a detailed and accurate way to consider the thermal interactions between buildings in an urban context to inform urban planning and design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental validation of multiphysics model simulations of the thermal response of a cement clinker rotary kiln at laboratory scale

Abstract An increasing demand for buildings, transportation systems and civil infrastructure development has driven expansion of cement consumption world‐wide, producing a significant increase in related global energy demand. With approximately 7% of the world‐wide industrial energy consumption (10.7 exajoules [EJ]), the cement industry is the third most energy intensive industrial processes and a key component for concrete, the most consumed composite material in the global construction industry. In cement manufacturing, the cement kiln accounts for most of the energy consumption in the production process. As the heart of a cement plant, the cement kiln is where the kiln feed primarily containing calcium oxide (CaO), silica (SiO 2 ), alumina (Al 2 O 3 ), and iron (Fe 2 O 3 ) are thermally and chemically transformed into clinker minerals. The presented work developed a multiphysics model, designed and built a laboratory‐scale rotary cement clinker kiln, and produced cement clinker at laboratory‐scale. The model was developed to study the interaction between the various thermal, fluid dynamic and chemical interactions involved in the sintering process used to form Portland cement clinker in an effort to reduce energy use. The analytical model was validated through experimental testing using a unique laboratory‐scale rotary cement kiln developed during the investigation. Also demonstrated was the feasibility of producing clinker at laboratory scale. This modeling and lab scale tests were designed to better understand the clinker sintering process so that operational and quality decisions can be made to optimize energy consumption without compromising cement clinker quality. The computational fluid dynamics modeling was developed in COMSOL Multiphysics 6.0. The characteristics of the combustion fluid flow, concentration of species, temperature and heat transfer were studied for a turbulent flow of methane (CH 4 ) gas and oxygen (O 2 ). Theory suggests that heat transfer impacts the cement production process but the multiphysics model more accurately describes the convection, conduction, and radiant heat transfer in the kilning process and thus allows for a better understanding of the energy exchange driving the chemical reactions that produce Portland cement. Clinker minerals were formed because of appropriate burning conditions implemented during experimental model validation.

Tabares, Juan David↗

Performance Assessment of the Overall Building Envelope Thermal Performance—Building Envelope Performance (BEP) Metric

Today, to describe the thermal performance of the building envelope and its components we use a variation of metrics; such as, R-value, ACH (air exchange rate per hour), SHGC (solar heat gain coefficient) of windows, U-factor etc. None of these performance indicators is meant to represent the overall thermal performance. In this paper, such a metric is introduced, the BEP (building envelope performance) value. Unlike the thermal resistance, typically expressed as an R-value, the BEP-value considers additional elements of heat transfer that affect the energy demand of the building because of exterior and interior (solar) thermal loads: conductive and radiant heat transfer, and air infiltration. To demonstrate BEP’s utility, validation studies were carried out by comparing the BEP-value to theoretical results using whole building energy simulation tools such as EnergyPlus and WUFI Plus. Results show that BEP calculations are comparable to calculations made using these simulation tools and that unlike other similar metrics, the BEP-value accounts for all heat transfer mechanisms that are relevant for the overall energy performance of the building envelope. The BEP-value thus allows comparing envelopes of buildings with different use types in a fair and realistic manner.

42 ENGINEERING↗

How Can Floor Covering Influence Buildings’ Demand Flexibility?

Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal deflection in neutron scattering sample environments at Oak Ridge National Laboratory

The neutron sources at Oak Ridge National Laboratory use a wide suite of sample environment equipment to deliver extreme conditions for a number of experiments. Much of this instrumentation focuses on extremes of temperature, such as cryostats, closed-cycle refrigerators in both low and high temperature configurations, and radiant heating furnaces. When the temperature is controlled across a large range, thermal deflection effects can notably move the sample and affect its alignment in the beam. Here, we combine these sample environments with neutron imaging and machine vision to determine the motion of a representative sample with respect to the neutron beam. We find vertical sample displacement on the order of 1–2 mm and horizontal displacement that varies from near-negligible to 1.2 mm. While these deflections are not relevant for some of the beamlines at the first target station at the spallation neutron source and the high flux isotope reactor, they will become critical for upcoming instrumentation at the second target station, as well as any instruments targeting sub-mm samples, as neutron sources and optics evolve to smaller and more focused beams. We discuss mitigation protocols and potential modifications to the environment to minimize the effect of misalignment due to thermal deflection.

47 OTHER INSTRUMENTATION↗

Comparing land surface temperature and mean radiant temperature for urban heat mapping in Philadelphia

Many cities are experiencing more frequent extreme heat during hot summers. With the rise of global temperature, the thermal comfort in urban areas become even worse. Quantitative information of the spatial distributions of urban heat has become increasingly important for resilience and adaptation to climate change in cities. This study compares satellite-derived land surface temperature (LST) and urban microclimate modeling-based mean radiant temperature (Tmrt) for mapping the urban heat distributions in Philadelphia, Pennsylvania, USA. Here, the LST was estimated based on Landsat 8 thermal imagery with a spatial resolution of around 100 m, while the Tmrt was simulated based on high resolution LiDAR and national aerial imagery program multispectral aerial imageries with a spatial resolution of 1 m. Result shows that both LST and Tmrt show a similar general pattern of the urban heat across the study area, while the Tmrt presents much more details of the heat variations street by street and neighborhood by neighborhood. The LST tends to have a stronger relationship with the Tmrt on building roofs, which are usually not the place for human activities. This studyprovides evidence for choosing more appropriate metrics in urban heat-related studies.

54 ENVIRONMENTAL SCIENCES↗

Radiant boiler for pressurized oxy-combustion and method of radiant trapping to control heat flux in high temperature particle-laden flows at elevated pressure

A boiler has a shell surrounding a vertical centerline. The shell defines an inner surface having an inner diameter and an inner length extending between an upper upstream end and a lower downstream end. The inner surface defines a hollow interior, the boiler having a pre-combustion zone, a combustion zone downstream from the pre-combustion zone, and a post-combustion zone downstream from the combustion zone. The shell is tapered outward along its length in at least a portion of the combustion zone. An oxidizer inlet is in fluid communication with the pre-combustion zone, and a fuel nozzle introduces fuel into the combustion zone. A tube assembly is mounted in the hollow interior of the shell for transferring heat to fluid flowing through the tube assembly. A flue duct is in fluid communication with the post-combustion zone for transporting flue gases from the hollow interior.

20 FOSSIL-FUELED POWER PLANTS↗

TESS Observations of the WASP-121 b Phase Curve

We study the red-optical photometry of the ultrahot Jupiter WASP-121 b as observed by the Transiting Exoplanet Survey Satellite (TESS) and model its atmosphere through a radiative transfer simulation. Given its short orbital period of ∼1.275 days, inflated state, and bright host star, WASP-121 b is exceptionally favorable for detailed atmospheric characterization. Toward this purpose, we use allesfitter to characterize its full red-optical phase curve, including the planetary phase modulation and secondary eclipse. We measure the day- and nightside brightness temperatures in the TESS passband as 3012{sub −42}{sup +40} and 2022{sub −602}{sup +254} K, respectively, and do not find a statistically significant phase shift between the brightest and substellar points. This is consistent with inefficient heat recirculation on the planet. We then perform an atmospheric retrieval analysis to infer the dayside atmospheric properties of WASP-121 b, such as its bulk composition, albedo, and heat recirculation. We confirm the temperature inversion in the atmosphere and suggest H{sup −}, TiO, and VO as potential causes of the inversion, absorbing heat at optical wavelengths at low pressures. Future Hubble Space Telescope and James Webb Space Telescope observations of WASP-121 b will benefit from its first full phase curve measured by TESS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Additive Approximation for Heat Transfer and for Stability Calculations in a Multi-filamentary Superconductor - part A

This paper addresses the applicability of the “additive approximation” of total thermal conductivity in heat transfer and in superconductor stability calculations. If cases (a), (b) and (c) denote total (conductive plus radiative), or only conductive or only radiative heat flux, respectively, each flux q-dot calculated with Fourier’s conduction law using the corresponding thermal conductivity (λ{sub a}, λ{sub b}, λ{sub c}), the additive approximation would be confirmed if the heat flux difference Δ q-dot = q-dot {sub a}− q-dot {sub b}− q-dot {sub c}, at any position of an investigated object, and at any time, converges to zero. This is not trivial because of the strong, non-linear temperature dependence of the radiation component. Heat transfer calculations including radiative transfer are presented in this paper, first for simple, homogeneous, thin film test samples and later for a multi-filamentary BSCCO 2223 superconductor. The simulated heat sources either result from a sudden increase of conductor boundary temperature or from flux flow and Ohmic resistances in the superconductor under a disturbance (like transport current exceeding critcal current density). The conductors, though very thin, are non-transparent to mid-IR radiation. Validity of the additive approximation is critical for superconductor stability against quench. Based on the applied numerical scheme, a hypothesis is suggested concerning correlation of the results of the simulation (the “numerical space”) with the experimental situation (the “physical reality”): Non-convergence of the numerical scheme might tightly be correlated with occurrence of a quench in the simulated superconductor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spectroscopic and Photometric Monitoring of a Poorly Known Highly Luminous OH/IR Star: IRAS 18278+0931

We present the time-dependent properties of a poorly known OH/IR star, IRAS 18278+0931 (hereafter IRAS 18+09), toward the Ophiuchus constellation. We have carried out long-term optical/near-infrared photometric and spectroscopic observations to study the object. From optical R- and I-band light curves, the period of IRAS 18+09 is estimated to be 575 ± 30 days and the variability amplitudes range from ΔR ∼ 4.0 mag to ΔI ∼ 3.5 mag. From the standard period–luminosity relations, the distance (D) to the object, 4.0 ± 1.3 kpc, is estimated. Applying this distance in the radiative transfer model, the spectral energy distribution is constructed from multiwavelength photometric and IRAS-LRS spectral data, which provide the luminosity, optical depth, and gas mass-loss rate of the object to be 9600 ± 500 L {sub ⊙}, 9.1 ± 0.6 at 0.55 μm, and 1.0 × 10{sup −6} M {sub ⊙} yr{sup −1}, respectively. The current mass of the object is inferred to be in the range 1.0−1.5 M {sub ⊙} assuming solar metallicity. Notably, the temporal variation of atomic and molecular features (e.g., TiO, Na i, Ca i, CO, H{sub 2}O) over the pulsation cycle of the OH/IR star illustrates the sensitivity of the spectral features to the dynamical atmosphere as observed in pulsating AGB stars.

36 MATERIALS SCIENCE↗

The Anatomy of an Unusual Edge-on Protoplanetary Disk. I. Dust Settling in a Cold Disk

As the earliest stage of planet formation, massive, optically thick, and gas-rich protoplanetary disks provide key insights into the physics of star and planet formation. When viewed edge-on, high-resolution images offer a unique opportunity to study both the radial and vertical structures of these disks and relate this to vertical settling, radial drift, grain growth, and changes in the midplane temperatures. In this work, we present multi-epoch Hubble Space Telescope and Keck scattered light images, and an Atacama Large Millimeter/submillimeter Array 1.3 mm continuum map for the remarkably flat edge-on protoplanetary disk SSTC2DJ163131.2–242627, a young solar-type star in ρ Ophiuchus. We model the 0.8 μm and 1.3 mm images in separate Markov Chain Monte Carlo (MCMC) runs to investigate the geometry and dust properties of the disk using the MCFOST radiative transfer code. In scattered light, we are sensitive to the smaller dust grains in the surface layers of the disk, while the submillimeter dust continuum observations probe larger grains closer to the disk midplane. An MCMC run combining both data sets using a covariance-based log-likelihood estimation was marginally successful, implying insufficient complexity in our disk model. The disk is well characterized by a flared disk model with an exponentially tapered outer edge viewed nearly edge-on, though some degree of dust settling is required to reproduce the vertically thin profile and lack of apparent flaring. A colder than expected disk midplane, evidence for dust settling, and residual radial substructures all point to a more complex radial density profile to be probed with future, higher-resolution observations.

47 OTHER INSTRUMENTATION↗