Large-scale fire suppression modeling of corrugated cardboard boxes on wood pallets in rack-storage configurations

In this study, the fire growth and suppression models in FireFOAM were validated for rack-storage commodities consisting of two solid fuels, namely corrugated cardboard boxes and hardwood pallets, which are referred to as Class 2 commodity. Validation experiments included two fire-growth and two fire-suppression configurations with different rack-storage array heights (3 and 5 tiers). In the suppression study, standard-response upright ceiling sprinklers (K-factor of 160 lpm/bar1/2) were used. The time-resolved chemical heat release rates obtained from the experiments were used to validate the fire growth model. The observed sprinkler activations and fire-spread patterns were used to validate the suppression model. This study identified that lateral flame spread is primarily enabled by flames impinging on the commodity's bottom surfaces. This study also showed that obstructions, such as wood pallets, can significantly impede convective and radiative heat transfer to the underside of the commodity, reducing the lateral flame spread rate. Fire-suppression modeling revealed that both surface water transport and lateral flame spread rates are important when predicting fire-suppression behavior. Therefore, as the rack-storage array height increases, so does the water transport time, which results in the fire becoming more difficult to control. Likewise, as the lateral spread rate increases, e.g., as occurs in the absence of wood pallets, fire-suppression also becomes more difficult.

Engineering↗

Fuel consumption impacts of auto roof racks

The after-market roof rack is one of the most common components attached to a vehicle for carrying over-sized items, such as bicycles and skis. It is important to understand these racks' fuel consumption impacts on both individual vehicles and the national fleet because they are widely used. We estimate the national fuel consumption impacts of roof racks using a bottom-up approach. Our model incorporates real-world data and vehicle stock information to enable assessing fuel consumption impacts for several categories of vehicles, rack configurations, and usage conditions. In addition, the model draws on two new data-gathering techniques, on-line forums and crowd-sourcing. The results show that nationwide, roof racks are responsible for 0.8‰ of light duty vehicle fuel consumption in 2015, corresponding to 100 million gallons of gasoline per year. Sensitivity analyses show that results are most sensitive to the fraction of vehicles with installed roof racks but carrying no equipment. Here, the aerodynamic efficiency of typical roof racks can be greatly improved and reduce individual vehicle fuel consumption; however, government policies to minimize extensive driving with empty racks--if successful--could save more fuel nationally.

30 DIRECT ENERGY CONVERSION↗

Innovative Ballasted Flat Roof Solar PV Racking System

The objective of this project was to reduce the cost of racking for PV solar on flat commercial rooftops. Cost reductions would come from both labor savings and material savings related to the installation process. The rack would need to accommodate the majority of modules available on the market. Cascade Engineering has a long history of converting traditional metal type applications over to plastic. Injection molding of plastics have numerous advantages including selection of resin for the application, placing the material exactly where it is needed, designing in features that will speed up the installation process, and weight reduction of the array. A plastic rack would need to meet the requirements of UL2703, Mounting systems, mounting devices, clamping/retention devices, and ground lugs for use with flat-plate photovoltaic modules and panels. Comparing original data to the end of project racking design, racking material costs were reduced 50% and labor costs reduced 64%. The racking product accommodates all 60 and 72 cell panels on the market, meets UL2703 requirements, contributes only 1.3 pounds per square foot of weight to the array, requires little ballast to secure the array, automatically grounds the module when the module is secured, stacks/nests well for shipping/fewer lifts to the roof, provides integrated wire routing, allows water to drain on the roof, and accommodates various seismic roof connections. Project goals were achieved as noted in the original funding application.

14 SOLAR ENERGY↗

Agrivoltaic Racking Design Optimization Based on Wind and Snow Loading Finite Element Analysis

The racking structure of photovoltaic (PV) systems plays a critical role in ensuring the PV panels generate power properly as it provides integral structural support and sometimes even solar tracking ability. Distinct applications of PV systems require variations of racking structure designs, which yield different mechanical performances under external loading conditions from the environment, such as heavy wind and snow. Past works, such as Reddy et al. [1], have analyzed the pressure effects of wind and snow loading on the racking structure of conventional rooftop and utility PV systems, but there is little knowledge of how various agrivoltaic racking systems perform, in terms of stress and strain, under the same loading conditions. There is also a knowledge gap in the industry on a set of optimized agrivoltaic racking design standards. This study investigates the mechanical performance of various existing racking systems and proposes novel designs that are optimized for agrivoltaics applications under wind and snow loading.

Liao, Quanhuan↗

A Case For Intra-rack Resource Disaggregation in HPC

The expected halt of traditional technology scaling is motivating increased heterogeneity in high-performance computing (HPC) systems with the emergence of numerous specialized accelerators. As heterogeneity increases, so does the risk of underutilizing expensive hardware resources if we preserve today’s rigid node configuration and reservation strategies. This has sparked interest in resource disaggregation to enable finer-grain allocation of hardware resources to applications. However, there is currently no data-driven study of what range of disaggregation is appropriate in HPC. To that end, we perform a detailed analysis of key metrics sampled in NERSC’s Cori, a production HPC system that executes a diverse open-science HPC workload. In addition, we profile a variety of deep-learning applications to represent an emerging workload. We show that for a rack (cabinet) configuration and applications similar to Cori, a central processing unit with intra-rack disaggregation has a 99.5% probability to find all resources it requires inside its rack. In addition, ideal intra-rack resource disaggregation in Cori could reduce memory and NIC resources by 5.36% to 69.01% and still satisfy the worst-case average rack utilization.

97 MATHEMATICS AND COMPUTING↗

Furniture Rack Corrosion Coupon Surveillance - 2012 Update

Under the L Basin corrosion surveillance program furniture rack coupons immersed for 14 years (FY2009 coupons) and 16 years (FY2011 coupons) were analyzed and the results trended with coupons exposed for shorter times. In addition, a section harvested from an actual furniture rack that was immersed for 14 years was analyzed for pitting in the weld and heat-affected-zone (HAZ) regions. The L Basin operations maintained very good water quality over the entire immersion period for these samples. These results for FY2009 and FY2011 coupons showed that the average pit depths for the 6061 and 6063 base metal are 1 and 2 mils, respectively, while those for the weld and HAZ are 3 and 4 mils, respectively. The results for the weld and HAZ regions are similar to coupons removed during the period of FY2003 to FY2007. These similarities indicate that the pit development occurred quickly followed by slow kinetics of increase in pit depth. For the actual furniture rack sample average pits of 5 and 2 mils were measured for the HAZ and weld, respectively. These results demonstrate that pitting corrosion of the aluminum furniture racks used to support the spent fuel occurs in waters of good quality. The corrosion kinetics or pit depth growth rate is much less that 1 mil/year, and would not impact long-term use of this material system for fuel storage racks in L Basin if good water quality is maintained.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Eligibility Assessment of Items in the TA-60 Rack Assembly and Alignment Complex Legacy Storage Yard

The U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office (NA-LA), documented and evaluated seven structures in the Technical Area 60 (TA-60) Rack Assembly and Alignment Complex (RAAC) legacy storage yard at Los Alamos National Laboratory (LANL or Laboratory) for listing in the National Register of Historic Places (National Register). This documentation and evaluation was conducted in compliance with Section 106 of the National Historic Preservation Act of 1966, as amended; the Code of Federal Regulations (36 CFR 800); the Programmatic Agreement among the U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office, the New Mexico State Historic Preservation Office and the Advisory Council on Historic Preservation Concerning Management of the Historic Properties at Los Alamos National Laboratory, Los Alamos New Mexico (PA)1; and A Plan for the Management of the Cultural Heritage at Los Alamos National Laboratory, New Mexico (LANL’s Cultural Resources Management Plan (2017). NA-LA makes the following National Register eligibility determinations: la cuna; the rack transporter (jeep, rack trailer, and steering dolly); the Mexia diagnostic rack; the Mexia device canister; the Mexia device mounting stand; and the Mexia target stand are eligible for listing in the National Register, and the second steering dolly is not eligible for listing in the National Register. This National Register evaluation was completed because LANL proposes to develop a consolidated waste facility in TA-60 next to the former RAAC. Across 3.56 acres, LANL proposes to construct an 8,000-square-foot, pre-engineered waste storage building; a 1,500-square-foot office/warehouse building; and 28,500 square feet of covered storage. The development will also include access control features and fencing, parking spaces, and utilities. Additionally, the Laboratory will continue to use the southern part of TA-60-0017 and reuse TA-60-0086 and TA-60-0324 in the development. The consolidated waste facility will operate as a central accumulation area—storing universal waste, mixed low-level (radioactive) waste, hazardous chemicals, and New Mexico special waste—until the waste can be shipped off site.

99 GENERAL AND MISCELLANEOUS↗

Rack assembly for mounting solar modules

A rack assembly is provided for mounting solar modules over an underlying body. The rack assembly may include a plurality of rail structures that are arrangeable over the underlying body to form an overall perimeter for the rack assembly. One or more retention structures may be provided with the plurality of rail structures, where each retention structure is configured to support one or more solar modules at a given height above the underlying body. At least some of the plurality of rail structures are adapted to enable individual rail structures o be sealed over the underlying body so as to constrain air flow underneath the solar modules. Additionally, at least one of (i) one or more of the rail structures, or (ii) the one or more retention structures are adjustable so as to adapt the rack assembly to accommodate solar modules of varying forms or dimensions.

Plaisted, Joshua Reed↗

Rack assembly for mounting solar modules

A rack assembly is provided for mounting solar modules over an underlying body. The rack assembly may include a plurality of rail structures that are arrangeable over the underlying body to form an overall perimeter for the rack assembly. One or more retention structures may be provided with the plurality of rail structures, where each retention structure is configured to support one or more solar modules at a given height above the underlying body. At least some of the plurality of rail structures are adapted to enable individual rail structures to be sealed over the underlying body so as to constrain air flow underneath the solar modules. Additionally, at least one of (i) one or more of the rail structures, or (ii) the one or more retention structures are adjustable so as to adapt the rack assembly to accommodate solar modules of varying forms or dimensions.

14 SOLAR ENERGY↗

Rack assembly for mounting solar modules

A rack assembly is provided for mounting solar modules over an underlying body. The rack assembly may include a plurality of rail structures that are arrangeable over the underlying body to form an overall perimeter for the rack assembly. One or more retention structures may be provided with the plurality of rail structures, where each retention structure is configured to support one or more solar modules at a given height above the underlying body. At least some of the plurality of rail structures are adapted to enable individual rail structures o be sealed over the underlying body so as to constrain air flow underneath the solar modules. Additionally, at least one of (i) one or more of the rail structures, or (ii) the one or more retention structures are adjustable so as to adapt the rack assembly to accommodate solar modules of varying forms or dimensions.

14 SOLAR ENERGY↗

Lessons Learned "Establishing an Electrically Safe Work Condition" Specifically related to Racking Electrical Breakers

During low voltage electrical equipment maintenance, a bad breaker was identified. The breaker was racked out from the substation cubicle without following the hazardous energy control process identified in the Integrated Work Document (IWD). The IWD required the substation to be in an electrically safe work condition prior to racking the breaker. Per NFPA 70E requirements, electrical equipment shall be put into an electrically safe work condition before an employee performs work on or interacts with equipment in a manner that increases the likelihood of creating an arc flash. Racking in or out a breaker on an energized bus may increase the likelihood of creating an arc flash dependent on equipment conditions. A thorough risk assessment must be performed prior to performing such a task. The risk assessment determines the risk control measures to be put in place prior to performing the work. Electrical Safety Officers (ESO) can assist in performing risk assessments and incorporating risk control measures.

30 DIRECT ENERGY CONVERSION↗

Server rack for improved data center management

Methods and systems for data center management include collecting sensor data from one or more sensors in a rack; determining a location and identifying information for each asset in the rack using a set of asset tags associated with respective assets; communicating the sensor and asset location to a communication module; receiving an instruction from the communication module; and executing the received instruction to change a property of the rack.

97 MATHEMATICS AND COMPUTING↗

Electronics rack with compliant heat pipe

An electronics rack comprising a first cage, a first heat sink positioned at a rear and in thermal communication with the first cage, a second cage positioned above the first cage, and a second heat sink in thermal communication with the second cage. In another aspect, the present invention provides an electronics rack comprising a frame, a cage, a heat sink positioned at a rear of the frame, and a compliant thermal collector operatively positioned between the cage and the heat sink. The compliant thermal collector can comprise a heat pipe having a non-linear shape that facilitates flexing of the heat pipe to change the length of the thermal collector. The thermal collector advantageously includes a plurality of heat pipes and a contact bar coupling the plurality of heat pipes. Preferably, the rack further includes an adjusting mechanism (e.g., threaded rods) for adjusting a position of the contact bar.

Bilski, Jr., Walter John↗

Server rack for improved data center management

Methods and systems for data center management include collecting sensor data from one or more sensors in a rack; determining a location and identifying information for each asset in the rack using a set of asset tags associated with respective assets; communicating the sensor and asset location to a communication module; receiving an instruction from the communication module; and executing the received instruction to change a property of the rack.

Bermudez Rodriguez, Sergio A.↗

Server rack for improved data center management

Methods and systems for data center management include collecting sensor data from one or more sensors in a rack; determining a location and identifying information for each asset in the rack using a set of asset tags associated with respective assets; communicating the sensor and asset location to a communication module; receiving an instruction from the communication module; and executing the received instruction to change a property of the rack.

Bermudez Rodriguez, Sergio↗

The cross-aisle seismic performance of storage rack base connections

Steel storage racks used in retail stores and warehouses are seismically designed as moment resisting frames in the down-aisle direction, and braced frames in the cross-aisle direction. While their down-aisle response is relatively well understood, there is little understanding of their cross-aisle response, especially as it pertains to the desired mode of inelastic deformation and associated design methods. In this paper, results are presented from six full scale tests on braced frames representing storage racks in the cross-aisle direction. These tests investigate the base plate thickness and dimensions, and the upright (column) cross section. The experiments indicate that inelastic deformation in the base plate provides stable hysteretic response with significant ductility and energy dissipation. Ductile tearing is also observed in welds connecting the base plate to the upright. However, it does not appear to negatively influence the hysteretic response. The tests are complemented by Finite Element (FE) simulations of the base connections. These simulations provide insights into internal force distributions within the connections. Based on these insights, analytical equations are proposed for characterizing the backbone curve of the hysteretic response, for use in displacement based design methods. It is determined that the current approach for characterizing design forces in the anchors is unconservative, since it does not incorporate the effects of strain hardening or the membrane action as the base plate undergoes large deformations. A new approach which incorporates these phenomena is presented, and determined to be significantly more accurate. Finally, limitations of the study are outlined and directions for future work are identified.

36 MATERIALS SCIENCE↗

Analysis of an existing spent fuel pool storage rack using current practices and updated depletion bias and uncertainty values - 14458

In accordance with NRC Information Notice 2011-03: Nonconservative Criticality Safety Analysis for Fuel Storage, a US nuclear power plant reviewed their analysis of record (AOR) for possible nonconservative technical specifications related to the criticality safety of fuel storage. During this review, it was determined that some legacy fuel assemblies did not meet all the assumptions of the AOR, but did meet the plant Technical Specifications. The plant entered into an Operability Evaluation in order to evaluate the moderator temperature and boron concentration assumptions used in the AOR, as well as evaluate the impact of including additional biases and depletion uncertainties for the non-borated case. As this study was part of a response to the NRC Information Notice, a full assessment was not conducted. A re-analysis of the spent fuel rack in accordance with current practices was performed. This analysis used the bounding core conditions, and included all biases and depletion uncertainties. The results challenged the 10CFR50.68(b) requirement that 'the k-effective must remain below 1.0 (subcritical), at a 95 percent probability, 95 percent confidence level, if flooded with un-borated water'. Credits for additional reactivity offsets were then analyzed. Previous assumptions for the measurement uncertainty were evaluated and subsequently reduced. New values for the depletion bias and uncertainty were applied. More detailed, realistic modeling was used to remove conservatisms. The results showed that the storage racks met the 10CFR50.68(b) criteria for the un-borated case. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗