Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantitative Phase Imaging (QPI)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Data supporting manuscript from L. Sheneman, G. Stephanopoulos, A.E. Vasdekis titled "Deep learning classification of lipid droplets in quantitative phase images" as currently under review at PLOS ONE. This includes: 1) raw and binary labeled Quantitative Phase Images (QPI) of Y. lipolytica cells used in the analyses described within the manuscript. 2) various derived data including classifier scores, etc.

Data supporting manuscript from L. Sheneman, G. Stephanopoulos, A.E. Vasdekis titled "Deep learning classification of lipid droplets in quantitative phase images" as currently under review at PLOS ONE. This includes: 1) raw and binary labeled Quantitative Phase Images (QPI) of Y. lipolytica cells used in the analyses described within the manuscript. 2) various derived data including classifier scores, etc.

ANN↗

Multispectral Quantitative Phase Imaging Using a Diffractive Optical Network

As a label‐free imaging technique, quantitative phase imaging (QPI) provides optical path length information of transparent specimens for various applications in biology, materials science, and engineering. Multispectral QPI measures quantitative phase information across multiple spectral bands, permitting the examination of wavelength‐specific phase and dispersion characteristics of samples. Herein, the design of a diffractive processor is presented that can all‐optically perform multispectral quantitative phase imaging of transparent phase‐only objects within a snapshot. The design utilizes spatially engineered diffractive layers, optimized through deep learning, to encode the phase profile of the input object at a predetermined set of wavelengths into spatial intensity variations at the output plane, allowing multispectral QPI using a monochrome focal plane array. Through numerical simulations, diffractive multispectral processors are demonstrated to simultaneously perform quantitative phase imaging at 9 and 16 target spectral bands in the visible spectrum. The generalization of these diffractive processor designs is validated through numerical tests on unseen objects, including thin Pap smear images. Due to its all‐optical processing capability using passive dielectric diffractive materials, this diffractive multispectral QPI processor offers a compact and power‐efficient solution for high‐throughput quantitative phase microscopy and spectroscopy.

36 MATERIALS SCIENCE↗

Quantitative phase microscopy monitors subcellular dynamics in single cells exposed to nanosecond pulsed electric fields

A substantial body of literature exists to study the dynamics of single cells exposed to short duration (<1 μs), high peak power (~1 MV/m) transient electric fields. Much of this research is limited to traditional fluorescence-based microscopy techniques, which introduce exogenous agents to the culture and are only sensitive to a single molecular target. Quantitative phase imaging (QPI) is a coherent imaging modality which uses optical path length as a label-free contrast mechanism, and has proven highly effective for the study of single-cell dynamics. In this work, we introduce QPI as a useful imaging tool for the study of cells undergoing cytoskeletal remodeling after nanosecond pulsed electric field (nsPEF) exposure. In particular, we use cell swelling, dry mass and disorder strength measurements derived from QPI phase images to monitor the cellular response to nsPEFs. We hope this demonstration of QPI's utility will lead to a further adoption of the technique for the study

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative phase imaging by gradient retardance optical microscopy

Abstract Quantitative phase imaging (QPI) has become a vital tool in bioimaging, offering precise measurements of wavefront distortion and, thus, of key cellular metabolism metrics, such as dry mass and density. However, only a few QPI applications have been demonstrated in optically thick specimens, where scattering increases background and reduces contrast. Building upon the concept of structured illumination interferometry, we introduce Gradient Retardance Optical Microscopy (GROM) for QPI of both thin and thick samples. GROM transforms any standard Differential Interference Contrast (DIC) microscope into a QPI platform by incorporating a liquid crystal retarder into the illumination path, enabling independent phase-shifting of the DIC microscope's sheared beams. GROM greatly simplifies related configurations, reduces costs, and eradicates energy losses in parallel imaging modalities, such as fluorescence. We successfully tested GROM on a diverse range of specimens, from microbes and red blood cells to optically thick (~ 300 μm) plant roots without fixation or clearing.

47 OTHER INSTRUMENTATION↗

Visualizing bleb mass dynamics in single cells using quantitative phase microscopy

Understanding biological responses to directed energy (DE) is critical to ensure the safety of personnel within the Department of Defense. At the Air Force Research Laboratory, we have developed or adapted advanced optical imaging systems that quantify biophysical responses to DE. One notable cellular response to DE exposure is the formation of blebs, or semi-spherical protrusions of the plasma membrane in living cells. In this work, we demonstrate the capacity of quantitative phase imaging (QPI) to both visualize and quantify the formation of membrane blebs following DE exposure. QPI is an interferometric imaging tool that uses optical path length as a label-free contrast mechanism and is sensitive to the non-aqueous mass density, or dry mass, of living cells. Blebs from both CHO-K1 and U937 cells were generated after exposure to a series of 600 ns, 21.2 kV/cm electric pulses. These blebs were visualized in real time, and their dry mass relative to the rest of the cell body was quantified as a function of time. It is our hope that this system will lead to an improved understanding of both DE-induced and apoptotic blebbing.

Steelman, Zachary A.↗

Fusing Quantitative-Phase Imaging with Airy Light- Sheet Microscopy

We report the integration of quantitative-phase imaging (QPI) with light-sheet (LS) fluorescent microscopy on to a standard inverted microscope that retains compatibility with microfluidics. QPI enables label-free imaging and number-density quantification of single cells and their organelles. Conversely, LS yields considerable speed and phototoxicity gains in quantifying the 4D dynamics of gene-encoded fluorescent biomarkers. We will detail the system design that relied on spatial light interferometry for QPI and an accelerating Airy- beam light-sheet for fluorescence, its performance, as well as results of a representative multivariate imaging analysis of single-cell metabolism.

imaging, lattice light sheet, Yarrowia lipolytica,↗

Transport of intensity equation: a tutorial

When it comes to “phase measurement” or “quantitative phase imaging”, many people will automatically connect them with “laser” and “interferometry”. Indeed, conventional quantitative phase imaging and phase measurement techniques generally rely on the superposition of two beams with a high degree of coherence: complex interferometric configurations, stringent requirements on the environmental stabilities, and associated laser speckle noise severely limit their applications in optical imaging and microscopy. On a different note, as one of the most well-known phase retrieval approaches, the transport of intensity equation (TIE) provides a new non-interferometric way to access quantitative phase information through intensity only measurement. Despite the insufficiency for interferometry, TIE is applicable under partially coherent illuminations (like the Köhler’s illumination in a conventional microscope), permitting optimum spatial resolution, higher signal-to-noise ratio, and better image quality. In this tutorial, we give an overview of the basic principle, research fields, and representative applications of TIE, focus particularly on optical imaging, metrology, and microscopy. The purpose of this tutorial is twofold. It should serve as a self-contained introduction to TIE for readers with little or no knowledge of TIE. On the other hand, it attempts to give an overview of recent developments in this field. These results highlight a new era in which strict coherence and interferometry are no longer prerequisites for quantitative phase imaging and diffraction tomography, paving the way toward new generation label-free three-dimensional microscopy, with applications in all branches of biomedicine.

42 ENGINEERING↗