Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quadrupole”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of combined function dipole-quadrupole PMQs magnets for NSLS-II upgrade

This paper focuses on the R&D performed for the development of permanent magnets-based dipoles-quadrupoles combined function magnets (PMQs) for the future NSLSII upgrade “complex bend” lattice (CB). This new lattice uses PMQs that provide both bending (dipole) and strong focusing (quadrupole) magnetic field on the electron beam. The permanent magnet (PM) technology is suitable for the high magnetic field strengths (0.5 T, 130 T/m) required for such combine function magnets. PM technology leads to a compact magnet design that is essential in realizing the complex bend lattice concept, as well as a passive magnet solution which does not require electrical power supply reducing power consumption by ~ 80% (from 1.7 MW to 0.3 MW for NSLS-II). Two PMQs magnets designs are under consideration: A hybrid design that use both PM and soft iron poles, and Halbach type that is a pure PM design. Both PMQs designs present challenges in achieving the specified magnetic field quality due to their higher sensitivity to errors (mechanical tolerances and PM properties). This paper presents cost-effective designs and prototypes results for hybrid and Halbach PMQs, addressing various technical challenges while meeting the field requirements of the complex bend lattice for the NSLS-II upgrade.

N'gotta, Patrick [Brookhaven]↗

Online multi-objective Bayesian optimization of injection efficiency and beam lifetime with skew quadrupoles at NSLS-II

At NSLS-II, the vertical emittance of electron beam is typically blown up to ~30 pm with a coupling wave to increase beam lifetime during user operation. As more and more insertion devices are added to the storage ring, injection efficiency to the ring drops noticeably in certain machine states, apparently due to degraded dynamic apertures. To help alleviate this issue, we have recently performed online multi-objective Bayesian optimization to increase injection efficiency while maintaining beam lifetime, by adjusting the strengths of 15 skew quadrupoles in non-dispersive sections. We report the results of this optimization effort.

Hidaka, Yoshiteru [Brookhaven]↗

Study of Quadrupole Fringe Fields in the Interaction Region of the Hadron Storage Ring of the Electron Ion Collider

Fringe fields in quadrupole magnets are usually neglected in studies of beam dynamics at accelerators. However, the extreme optical parameters present in the final focus of a collider such as the Electron–Ion Collider (EIC) may give rise to effects that should not be overlooked. The calculation of quadrupole fringe fields presented in this study follows the procedure outlined in Ref. [1], specialized to the case of a straight reference orbit (i.e., with no dipole field component). A right-handed Cartesian coordinate system is employed, with the $z$-axis aligned with the quadrupole axis and $x$ and $y$ denoting the horizontal and vertical transverse coordinates, respectively. The magnetic quadrupole field gradient, $G = \partial B_y / \partial x$, transitions from its peak value inside the quadrupole—where it is nearly independent of the longitudinal coordinate $z$—to zero at some distance beyond the magnet edge. Consequently, $G$ is treated as a function of $z$. The region over which this variation occurs is defined as the quadrupole fringe field region. The study begins with the development of a description of the magnetic field in the fringe region using a power-series expansion in the transverse coordinates $x$and $y$, consistent with the longitudinally varying gradient. A model for the $z$-dependence of the gradient is then proposed and adjusted to reproduce magnetic field data obtained from three-dimensional field calculations. To evaluate the impact of the fringe fields on beam dynamics, the corresponding vector potential is derived and incorporated into a Hamiltonian formulation of particle motion. The significance of the fringe fields is quantified by calculating the amplitude-dependent tune shift from the Hamiltonian. Using linear beam optics parameters of the Hadron Storage Ring (HSR) of the EIC, the tune shift due to the fringe fields of all quadrupole magnets in the IR-6 interaction region is evaluated. Finally, the resulting tune shifts are compared with those arising from other nonlinear field components present in the HSR.

43 PARTICLE ACCELERATORS↗

Quadrupole wiggler for a collinear wakefield accelerator

A quadrupole wiggler consisting of a row of alternating-polarity permanent magnet-excited quadrupoles is used in a collinear wakefield accelerator under development at Argonne National Laboratory. Fine translational and angular adjustment mechanisms are implemented in all quadrupoles to obtain a better than 1−μ⁢m precision in the alignment of quadrupole wiggler assemblies. The quadrupole’s magnetic and mechanical designs are described. Two wiggler prototypes were fabricated, aligned, and characterized performing pulsed wire magnetic measurements. The sensitivity of the quadrupole wiggler alignment to the ambient temperature was measured.

43 PARTICLE ACCELERATORS↗

Understanding the Quadrupole Mass Filter and Testing a High-Resolution QMS RGA for ITER

A common type of residual gas analyzer is the quadrupole mass spectrometer. One of the main components within this instrument is a mass filter known as the quadrupole. It is responsible for the selective throughput of the ionized gas particles - by ascending mass number - prior to ion impacts on the analyzer (or detector) surface from which the ion current signal is generated for processing. However, the quadrupole is not fully described in relation to the electric field characteristics and the function as an ion mass separator. This paper describes the basic origins of the electrical design, the intricate assembly criteria, and performance of the quadrupole within the spectrometer. A specialized quadrupole mass spectrometer is part of a configuration for a diagnostic gas analyzer system planned for ITER, a fusion research machine. It has a verified capability, essential as a diagnostic criterion for this reactor project, to successfully deconvolute the mass signals of Helium-4 and deuterium (reactor fuel exhaust gases, separated by only 0.026 atomic mass units), down to a relative three-percent concentration of the former gas. The associated preliminary testing, performed at the Oak Ridge National Laboratory, is also addressed. Finally, one of the key parameters used to express gas concentration, the relative sensitivity factor, will be explained, including an evaluation of dependency on other variables.

Marcus, Chris [ORNL] (ORCID:0000000190139636)↗

Spectroscopic quadrupole moments in 124 $\mathrm{Xe}$

The Xe isotopic chain with four valence protons above the Z=50 shell closure is an ideal laboratory for the study of the evolution of nuclear deformation. At the N=82 shell closure, 136 Xe presents all characteristics of a doubly closed shell nucleus with a spherical shape. In the very neutron-deficient isotopes close to N=50, the α-decay chain of Xe was investigated to probe the radioactive decay properties near the drip-line and the magicity of 100 Sn. Additionally, the Xe isotopes present higher order symmetries in the nuclear deformation such as the octupole degree of freedom near N=60 and N=90 or O(6) symmetry in stable isotopes. The relevance of the O(6) symmetry has been investigated by measuring the spectroscopic quadrupole moment of the first excited states in 124 Xe. In the O(6) symmetry limit, the spectroscopic quadrupole moment of collective states is expected to be null. A stable 124 Xe beam with energies of 4.03A MeV and 4.11 A MeV was used to bombard a nat W target at the GANIL facility. Excited states were populated via the safe Coulomb excitation reaction. The collision of the heavy ions with a large Z at low energy make this reaction sensitive to the diagonal E2 matrix element of the excited states. The recoils were detected in the VAMOS++ magnetic spectrometer and the γ rays in the AGATA tracking array. The least squares fitting code gosia was used for the analysis to extract both E2 and M1 transitional and E2 diagonal matrix elements. The rotational ground state band was populated up to the 8$^{+}_{1}$ state as well as the 2$^{+}_{2}$ and 4$^{+}_{2}$ states. Using high precision spectroscopic data to constrain the gosia fit, the spectroscopic quadrupole moments of the 2$^{+}_{1}$, 4$^{+}_{1}$, and 6$^{+}_{1}$ states were determined for the first time. The spectroscopic quadrupole moments were found to be negative, large, and constant in the ground state band underlining the prolate axially deformed ground state band of 124 Xe. Here, the present experimental data confirm that the O(6) symmetry is substantially broken in 124 Xe .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electric field gradients at rubidium sites in rubidium uranyl nitrate and quadrupole moments of 85 Rb and 87 Rb

The electronic structure along the axial direction of the uranyl ion in rubidium uranyl nitrate (RbUO 2 (NO 3 ) 3 ) has been studied by nuclear quadrupole resonance and nuclear magnetic resonance measurements of 85 Rb and 87 Rb quadrupole couplings. Here, the parameter of interest in these experiments is the electric field gradient at the Rb sites, which may be compared with values com- puted by various theoretical approaches. From this analysis an accurate ratio of the quadrupole moments of 85 Rb and 87 Rb has also been obtained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quadrupole Effects in the Photoionisation of Sodium 3s in the Vicinity of the Dipole Cooper Minimum

A procedure to obtain relativistic expressions for photoionisation angular distribution parameters using the helicity formulation is discussed for open-shell atoms. Electric dipole and quadrupole transition matrix elements were considered in the present work, to study the photoionisation dynamics of the 3s electron of the sodium atom in the vicinity of the dipole Cooper minimum. We studied dipole–quadrupole interference effects on the photoelectron angular distribution in the region of the dipole Cooper minimum. Interference with quadrupole transitions was found to alter the photoelectron angular distribution, even at rather low photon energies. The initial ground and final ionised state discrete wavefunctions of the atom were obtained in the present work using GRASP, and we employed RATIP with discrete wavefunctions, to construct continuum wavefunctions and to calculate transition amplitudes, total cross-sections and angular distribution asymmetry parameters.

74 ATOMIC AND MOLECULAR PHYSICS↗

A survey of nuclear quadrupole deformation in order to estimate the nuclear MQM and its relative contribution to the atomic EDM: Searching for the best candidate to focus on an atomic EDM measurement: A nuclear physics perspective

Abstract Measurement of a non-zero permanent electric dipole moment (EDM) in fundamental particles, such as in an electron or a neutron, or in nuclei or atoms, can help us gain a handle on the sources of Charge-Parity (CP) violation, both in the Standard Model (SM) and beyond. The nuclear magnetic quadrupole moment (MQM), the central topic of this work, is also CP, P, and T violating. Nucleons and nuclei have a non-zero MQM from sources within the SM, but the nuclear MQM is dramatically enhanced if the nuclei are structurally quadrupole deformed. Multiple sources contribute to an atomic EDM namely: (i) nuclear EDM through its Schiff moment, which is enhanced by nuclear octupole deformation, (ii) CP violating interactions between the electrons and the nuclei, and (iii) the nuclear MQM that contributes to the atomic EDM in atoms with an unpaired valence electron. Our survey of nuclear quadrupole deformation identified 48 isotopes as ideal systems in which to search for a CP violating EDM via their enhanced nuclear MQM. Of these candidates, $$^{223,225}$$ 223 , 225 Fr, $$^{223}$$ 223 Ra, $$^{223,225,227}$$ 223 , 225 , 227 Ac, $$^{229}$$ 229 Th, and $$^{229}$$ 229 Pa also have maximally enhanced nuclear Schiff moment contribution due to their octupole deformation. Laser cooling of the isotopes of Fr and Ra, among a few others, has already been demonstrated, making $$^{223,225}$$ 223 , 225 Fr and $$^{223}$$ 223 Ra some of the best systems in which to measure an EDM.

MohanMurthy, Prajwal↗

Effect of CLIQ on Training of HL-LHC Quadrupole Magnets

The high-luminosity LHC upgrade requires stronger than LHC low-beta quadrupole magnets to reach the luminosity goals of the project. The project is well advanced and HL-LHC quadrupole magnets are currently being commissioned in US Labs (MQXFA magnets) and CERN (MQXFB magnets). Those are the first Nb 3 Sn magnets to be used in any large particle accelerator. At development stages, many Nb 3 Sn accelerator sub-scale models showed relatively slow training and MQXFA magnets were projected to have low tens of quenches before reaching operational field. Recently it was shown that dedicated capacitor-based de-vices can affect Nb 3 Sn magnet training, and it was suggested that CLIQ, a capacitor-based device intended for quench protection, can do too. Here, the present paper investigates effects on training likely induced by CLIQ, using the base fact that only half the coils in a quadrupole experience upward current modulation at quench because of capacitor discharge. The study encompasses all MQXFA production magnets trained at BNL to date. No other high-statistics data from identical magnets (series) with CLIQ protection exist so far. Implications and opportunities stemming from data analysis are discussed and conclusions drawn.

43 PARTICLE ACCELERATORS↗

Benchmarking the Use of BPM Quadrupole Moments to Measure Emittance

For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer transverse emittance. By compositing many BPMs together, it becomes possible to improve the quality of the quadrupole signal. The Fermilab Booster BPM system has been used to measure these quadrupole moments in the past year and derive emittances from them. Recent benchmarks show that the derived BPM emittances show similar emittance evolution and value to IPM and Multiwire data. This approach can both supplement and complement existing non-intercepting emittance monitors in accelerators.

Balcewicz, M. A. [Fermilab]↗

Tunable Permanent Magnet Quadrupole Operating at Cryogenic Temperatures for Accelerators

The project objective is to develop a compact and tunable quadrupole using Electron Energy Corporation (EEC)’s PM materials for cryogenic accelerator applications. To achieve this objective, EEC and SLAC National Accelerator Laboratory (SLAC) will collaborate to develop a cost-effective quadrupole and optimize the conventional manufacturing process. Based on previous experience, EEC designed an innovative field adjustment capability using tuning magnets which is able to achieve all the requirements for SLAC’s cold copper collider (C3 ) application. These novel ideas enable us to develop a compact and tunable quadrupole magnet superior to the current designs. Our approach is to leverage EEC's over 50 years of experience in magnet manufacturing and SLAC’s beamline test capabilities.

42 ENGINEERING↗

Systematic Errors Induced by Dipole Component Change in Quadrupole Beam-Based Alignment Measurements for Circular Accelerators

Beam-based alignment (BBA) for quadrupole magnets is now a well-established process for circular accelerators to steer beam orbit through the magnetic centers such that beam orbit is not disturbed when the gradients of quadrupoles are changed. At some facilities, the centers estimated from BBA techniques are also used as a proxy for steering beam through the centers of nearby nonlinear magnets to minimize degradation of nonlinear dynamics caused by off-centered orbit. The random errors associated with BBA are well known, but very little attention has been paid to the systematic error generated by a dipole component change, or equivalently a shift in the magnetic center, when the quadrupole strength is varied. The analytical formulas for this error and its amplification factor (potentially a few orders of magnitude) with respect to the magnetic center motion have been derived and confirmed with simulations. We address the significance of this error as well as the part that cannot be estimated from the beam-based measurement alone. Finally, the BBA measurements obtained at NSLS-II and their systematic errors on the order of hundreds of microns are discussed.

43 PARTICLE ACCELERATORS↗

Benchmarking the Use of BPM Quadrupole Moments to Measure Emittance

For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer transverse emittance. By compositing many BPMs together, it becomes possible to improve the quality of the quadrupole signal. The Fermilab Booster BPM system has been used to measure these quadrupole moments in the past year and derive emittances from them. Recent benchmarks show that the derived BPM emittances show similar emittance evolution and value to IPM and Multiwire data. This approach can both supplement and complement existing non-intercepting emittance monitors in accelerators.

Balcewicz, Michael A. [Fermilab] (ORCID:0009000557↗

Performance of a MQXF Nb 3 Sn Quadrupole Magnet Under Different Stress Level

In a dipole or in a quadrupole accelerator magnet, the displacement of the coil turns induced by the electromagnetic forces can cause quenches limiting the magnet performance. For this reason, an azimuthal preload is applied to avoid azimuthal movements of the coil up to the required operational current. However, several tests showed that accelerator magnets can operate with a partial preload, i.e. that coil unloading during the ramp does not prevent reaching higher currents. This issue is particularly relevant for Nb 3 Sn magnets, where the loads applied to the Nb3Sn filaments can reach the degradation limits of critical current. In order to investigate the impact of coil preload on the quench performance, the MQXFS6 short model quadrupole for the High Luminosity Upgrade was tested under an azimuthal preload at 80% of the short sample current, reaching 93% of short sample current at 1.9 K. The preload was then released to 60%, still showing ability to operate in the range of 80-85% of short sample current as required by HL-LHC project. With this lower preload, the ability of going above 90% of short sample was lost, and a significant training appeared above 85%. When the preload was restored to the original 80% value, the magnet reached with few quenches 95% of short sample (13.4 T peak field). Magnetic measurements confirm the larger movement of the coil in the case with lower preload, and agree with finite element simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nuclear Quadrupole Resonance for Substance Detection

This review paper provides a comprehensive overview of recent advances in nuclear quadrupole resonance (NQR) spectroscopy for substance detection, highlighting its principles, methodologies, and applications. The paper elucidates the fundamental physics underlying NQR spectroscopy, emphasizing the interaction between nuclear quadrupole moments and electric field gradients. It explores the various experimental techniques and instrumentation developments that have enabled the sensitive detection and precise characterization of substances containing quadrupolar nuclei. A significant portion of the survey is dedicated to discussing the diverse applications of NQR spectroscopy, including the detection of explosives, drug pharmaceuticals, and material authentication. Furthermore, the survey examines the challenges and limitations associated with NQR spectroscopy, including issues related to signal-to-noise ratio (SNR), temperature dependency, and substance restrictions. Strategies to overcome these challenges are discussed, offering insights into the future directions of NQR spectroscopy research that includes artificial intelligence (AI), internet of things (IoT) integration, incorporating a cloud database for NQR parameter storage, and multi-modal analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assembly and Pre-Loading Specifications for the Series Production of the Nb 3 Sn MQXFA Quadrupole Magnets for the HL-LHC

We report the High Luminosity LHC (HL-LHC) Project is planning to install 16 cold-masses made with Nb 3 Sn quadrupole magnets in the LHC Interaction Regions to significantly increase its luminosity. Half of these cold masses are fabricated at BNL, FNAL, and LBNL under the US Accelerator Research Program (AUP). Each cold mass includes two identical Nb 3 Sn quadrupole magnets, called MQXFA with a magnetic length of 4.2 m. Currently, the AUP project has completed the fabrication and test of the first 5 pre-series magnets, and is working on the following 16 magnets for the series production. The brittleness and strain sensitivity of the Nb 3 Sn superconducting material requires a careful definition of the allowable maximum stress in the windings during magnet assembly and pre-load, and a tight control of their variation within the whole coil length. Therefore, a series of assembly and pre-load specifications have been defined with the goals of minimizing the risk of conductor degradation and providing the mechanical support required to reach the nominal current during powering. In this paper we present the specifications defined for the MQXFA magnets and applied during the different assembly phases and during the pre-load process of the first 5 pre-series magnets.

43 PARTICLE ACCELERATORS↗

The spectroscopic quadrupole moment of the 2 1 + state of 12 C: A benchmark of theoretical models

The spectroscopic quadrupole moment of the first 2 + state of 12 C has been measured employing the Coulomb-excitation re-orientation technique. Our result of $Q_{s} (2^{+}_{1}) = +9.3^{+3.5}_{-3.8}$ efm 2 suggests a larger oblate deformation than previously reported. Combining this with the consistently re-analyzed adopted value, we present the most precise value to date of $Q_{s} (2^{+}_{1})$ = +9.5(18) efm 2 , which is consistent with a geometrical rotor description. This simple outcome is compared to state-of-the-art shell-model, mean-field, ab initio calculations, cluster-based and geometrical-like theories, which show varying degrees of emergent quadrupole collectivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗