Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QCM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Gas Dynamics, Characterization, and Calibration of Fast Flow Flight Cascade Impactor Quartz Crystal Microbalances (QCM) for Aerosol Measurements

During recent high altitude flights, we have tested the aerosol section of the fast flow flight cascade impactor quartz crystal microbalance (QCM) on loan to Howard University from NASA. The aerosol mass collected during these flights was disappointingly small. Increasing the flow through the QCM did not correct the problem. It was clear that the instrument was not being operated under proper conditions for aerosol collect ion primarily because the gas dynamics is not well understood. A laboratory study was therefore undertaken using two different fast flow QCM's in an attempt to establish the gas flow characteristics of the aerosol sections and its effect on particle collection, Some tests were made at low temperatures but most of the work reported here was carried out at room temperature. The QCM is a cascade type impactor originally designed by May (1945) and later modified by Anderson (1966) and Mercer et al (1970) for chemical gas analysis. The QCM has been used extensively for collecting and sizing stratospheric aerosol particles. In this paper all flow rates are given or corrected and referred to in terms of air at STP. All of the flow meters were kept at STP. Although there have been several calibration and evaluation studies of moderate flow cascade impactors of less than or equal to 1 L/rein., there is little experimental information on the gas flow characteristics for fast flow rates greater than 1 L/rein.

Grant, J.R.↗

Structural Analysis of the QCM Aboard the ER-2

As a result of recent supersonic transport (SST) studies on the effect they may have on the atmosphere, several experiments have been proposed to capture and evaluate samples of the stratosphere where SST's travel. One means to achieve this is to utilize the quartz crystal microbalance (QCM) installed aboard the ER-2, formerly the U-2 reconnaissance aircraft. The QCM is a cascade impactor designed to perform in-situ, real-time measurements of aerosols and chemical vapors at an altitude of 60,000 - 70,000 feet. The ER-2 is primarily used by NASA for Earth resources to test new sensor systems before they are placed aboard satellites. One of the main reasons the ER-2 is used for this flight experiment is its capability to fly approximately twelve miles above sea level (can reach an altitude of 78,000 feet). Because the ER-2 operates at such a high altitude, it is of special interest to scientists interested in space exploration or supersonic aircraft. Some of the experiments are designed to extract data from the atmosphere around the ER-2. For the current flight experiment, the QCM is housed in a frame that is connected to an outer pod that is attached to the fuselage of the ER-2. Due to the location of the QCM within the housing frame and the location of the pod on the ER-2, the pod and its contents are subject to structural loads. In addition to structural loads, structural vibrations are also of importance because the QCM is a frequency induced instrument. Therefore, a structural analysis of the instrument within the frame is imperative to determine if resonance and/or undesirable deformations occur.

Jones, Phyllis D.↗

Quartz Crystal Microbalance (QCM) monitor of contamination for LES-8/9

A Quartz Crystal Microbalance (QCM) was used to monitor condensable contamination during the launching of two Lincoln Laboratory Experimental Satellites--LES-8 and LES-9. The QCM was installed on the dispenser truss and measured contamination by means of a frequency shift of a quartz crystal oscillator. By using a special crystal cut and a second reference quartz crystal, the sensor had extreme sensitivity and remarkable temperature independence. A 1-Hz frequency shift, which corresponds to 3.5 x 10 to the -9th power g/sq cm was resolved by the flight instrumentation.

Lynch, J. T.↗

Performance of a flight qualified, thermoelectrically temperature controlled QCM sensor with power supply, thermal controller and signal processor

A thermoelectrically temperature controlled quartz crystal microbalance (QCM) system was developed for the measurement of ion thrustor generated mercury contamination on spacecraft. Meaningful flux rate measurements dictated an accurately held sensing crystal temperature despite spacecraft surface temperature variations from -35 C to +60 C over the flight temperature range. An electronic control unit was developed with magentic amplifier transformer secondary power supply, thermal control electronics, crystal temperature analog conditioning and a multiplexed 16 bit frequency encoder.

Wallace, D. A.↗

QCM Thermo-Gravimetric Analysis (QTGA) Comparisons

The ASTM E-1559 apparatus has been used for years at NASA/Goddard Space Flight Center (GSFC) to determine in situ outgassing rate information, as well as pertinent in situ TML and multiple VCM values. The apparatus also affords the opportunity to experimentally compute the evaporation rates of molecular species that are reemitted as the Quartz Crystal Microbalances (QCMs) are gradually warmed up at some controlled temperature. Typically the molecular mass that accumulates onto the test QCMs are a compilation of species that are outgassing from the sample due to their respective activation energies and the desorption processes that the sample undergoes at various tested temperatures. It has been speculated that if there is too much molecular buildup of condensed water vapor (ice) onto the QCM crystal that a significantly higher temperature would be needed to break these "ice" bonds. ASTM E-1559 data plots will be used to demonstrate the thermogravimetric effects of water and other miscible molecular species with various water/ice thicknesses and at different evaporation rates.

Rosecrans, Glenn↗

ASTM E 1559 method for measuring material outgassing/deposition kinetics has applications to aerospace, electronics, and semiconductor industries

The American Society for Testing and Materials has published a new standard test method for characterizing time and temperature-dependence of material outgassing kinetics and the deposition kinetics of outgassed species on surfaces at various temperatures. This new ASTM standard, E 1559(1), uses the quartz crystal microbalance (QCM) collection measurement approach. The test method was originally developed under a program sponsored by the United States Air Force Materials Laboratory (AFML) to create a standard test method for obtaining outgassing and deposition kinetics data for spacecraft materials. Standardization by ASTM recognizes that the method has applications beyond aerospace. In particular, the method will provide data of use to the electronics, semiconductor, and high vacuum industries. In ASTM E 1559 the material sample is held in vacuum in a temperature-controlled effusion cell, while its outgassing flux impinges on several QCM's which view the orifice of the effusion cell. Sample isothermal total mass loss (TML) is measured as a function of time from the mass collected on one of the QCM's which is cooled by liquid nitrogen, and the view factor from this QCM to the cell. The amount of outgassed volatile condensable material (VCM) on surfaces at higher temperatures is measured as a function of time during the isothermal outgassing test by controlling the temperatures of the remaining QCM's to selected values. The VCM on surfaces at temperatures in between those of the collector QCM's is determined at the end of the isothermal test by heating the QCM's at a controlled rate and measuring the mass loss from the end of the QCM's as a function of time and temperature. This reevaporation of the deposit collected on the QCM's is referred to as QCM thermogravimetric analysis. Isothermal outgassing and deposition rates can be determined by differentiating the isothermal TML and VCM data, respectively, while the evaporation rates of the species can be obtained as a function of temperature by differentiating the QCM thermogravimetric analysis data.

Garrett, J. W.↗

Cost Models for MMC Manufacturing Processes

The quality cost modeling (QCM) tool is intended to be a relatively simple-to-use device for obtaining a first-order assessment of the quality-cost relationship for a given process-material combination. The QCM curve is a plot of cost versus quality (an index indicating microstructural quality), which is unique for a given process-material combination. The QCM curve indicates the tradeoff between cost and performance, thus enabling one to evaluate affordability. Additionally, the effect of changes in process design, raw materials, and process conditions on the cost-quality relationship can be evaluated. Such results might indicate the most efficient means to obtain improved quality at reduced cost by process design refinements, the implementation of sensors and models for closed loop process control, or improvement in the properties of raw materials being fed into the process. QCM also allows alternative processes for producing the same or similar material to be compared in terms of their potential for producing competitively priced, high quality material. Aside from demonstrating the usefulness of the QCM concept, this is one of the main foci of the present research program, namely to compare processes for making continuous fiber reinforced, metal matrix composites (MMC's). Two processes, low pressure plasma spray deposition and tape casting are considered for QCM development. This document consists of a detailed look at the design of the QCM approach, followed by discussion of the application of QCM to each of the selected MMC manufacturing processes along with results, comparison of processes, and finally, a summary of findings and recommendations.

Elzey, Dana M.↗

Structural Loading on the QCM/SAW Instrument Aboard the ER-2 Used for Atmospheric Testing

Several experiments have been proposed to capture and evaluate samples of the atmosphere where SST's travel. One means to achieve this is to utilize the quartz crystal microbalance (QCM) / surface acoustical wave (SAW) instrument installed aboard the ER-2, formerly the U-2 reconnaissance aircraft. The QCM is a cascade impactor designed to perform in-situ, real-time measurements of aerosols and chemical vapors at an altitude of 60,000-70,000 feet. The primary use of the ER-2 is by NASA for Earth resources to test new sensor systems before being placed aboard satellites. One of the main reasons the ER-2 is used for this flight experiment is its capability to fly approximately twelve miles above the sea level (can reach an altitude of 78,000 feet). Because the ER-2 operates at such a high altitude, it is of special interest to scientists interested in space exploration or supersonic aircraft. The purpose of some of the experiments is to extinct data from the atmosphere around the ER-2. For the current CSTEA flight experiment, the housing of the QCM is in a frame that connects to an outer pod that attaches to the fuselage of the ER-2. Due to the location of the QCM within the housing frame and the location of the pod on the ER-2, the pod and its contents are subject to structural loads. In addition to structural loads, structural vibrations are also of importance because the QCM output data is based on the determination of beat frequencies between a pair of oscillators (one coated, the second uncoated, according to the chemical reaction being monitored). A structural analysis of this system can indicate whether potential resonances may exist between the (higher) structural modal frequencies and the beat frequencies. In addition undesirable deformations may result due to maximum expected static or dynamic loads during typical flight conditions. If the deformations are excessive they may adversely affect the accuracy the instrumentation output.

Bainum, Peter M.↗

Post-flight analyses of the crystals from the M0003-14 quartz crystal microbalance experiment

Quartz Crystal Microbalances constructed by QCM Research were flown on the leading and trailing edges of the Long Duration Exposure Facility (LDEF) as one of the sub-experiments of M0003. Response of the crystals coated with 150 A of IN2O3ZnS was recorded during the first 424 days of the mission. A second QCM with crystals coated with 150 A was also flown but not monitored. The flight data and temperature profiles will be presented. After the flight, the QCM's were disassembled and analyzed. The samples included the crystals from the leading and trailing edge samples of both types of coatings along with the reference crystals which were inside the QCM housing. Analyses were performed by scanning electron microscopy, energy dispersive x ray analysis, x ray photoelectron spectroscopy, ion microprobe mass analysis, and reflectance spectroscopy in the infrared and ultraviolet/visible region. The crystals were contaminated predominantly with silicone compounds. The contamination is higher on the leading edge than on the trailing edge, and higher on the exposed crystal than on the reference crystals. No significant differences in composition of the In2O3 crystals were noted. Differences in the reflectance and surface analysis of the Zns crystals will be discussed.

Stuckey, W. K.↗

Post-flight analyses of the crystals from the M0003-14 quartz crystal microbalance experiment

Quartz Crystal Microbalances constructed by QCM Research were flown on the leading and trailing edges of LDEF as one of the sub-experiments of M0003. Response of the crystals coated with 150 A of In2O3 was recorded during the first 424 days of the mission. A second QCM with crystals coated with 150 A of ZnS was also flown but not monitored. After the flight, the QCM's were disassembled and analyzed in The Aerospace Corporation laboratories. The samples included the crystals from the leading and trailing edge samples of both types of coatings along with the reference crystals, which were inside the QCM housing. Analyses were performed by scanning electron microscopy, energy dispersive x-ray analyses, x-ray photoelectron spectroscopy, ion microprobe mass analysis, and reflectance spectroscopy in the infrared and UV/visible regions. The crystals are contaminated predominantly with silicone compounds. The contamination is higher on the leading edge than on the trailing edge and higher on the exposed crystals than on the reference crystals.

Stuckey, W. K.↗

Mass Loading Characteristics of Crystal Clock Oscillators

The 10-MHz piezoelectric quartz-crystal microbalance (QCM) has been used extensively for stratospheric aerosol sampling. We have undertaken laboratory studies of the QCM response to mass loading by trace gases. However, this device requires dual oscillator circuitry and the mass sensitivity can often be affected by the electronics. The coatings on the quartz crystals are sometimes difficult to remove after they have reacted with a particular gas and a disposable crystal system would be desirable. The cost of the dual oscillator-based QCM makes this a prohibitive option. Since our goal is to develop a cost-effective microbalance system with stable electronics we have begun testing of crystal clock oscillators, which are assembled with their own circuitry. We have been using chemically specific coatings for ozone to determine if the sensitivity and mass-frequency ratios are comparable to that of the 10-MHz QCM.

Cobb, Janel↗

Material Outgassing, Identification and Deposition, MOLIDEP System

The outgassing tests are performed employing a modified vacuum operated Cahn analytical microbalance, identified as the MOLIDEP system. The test measures under high vacuum, the time varying Molecular mass loss of a material sample held at a chosen temperature; it Identifies the outgassing molecular components using an inline SRS 300 amu Residual Gas Analyzer (RGA) and employs a temperature controlled 10 MHz Quartz Crystal Microbalance (QCM) to measure the condensable DEPosits. Both the QCM and the RGA intercept within the conductive passage the outgassing products being evacuated by a turbomolecular pump. The continuous measurements of the mass loss, the rate of loss, the sample temperature, the rate of temperature change, the QCM temperature and the QCM recorded condensable deposits or rate of deposits are saved to an Excel spreadsheet. A separate computer controls the RGA.

Scialdone, John J.↗

Use of the quartz crystal microbalance to determine the monomeric friction coefficient of polyimides

When a thin film of polymer is coated on to a quartz crystal microbalance (QCM), the QCM can be used to detect the rate of increase in weight of the polymer film as the volatile penetrant diffuses into the polymer. From this rate information the diffusion coefficient of the penetrant into the polymer can be computed. Calculations requiring this diffusion coefficient lead to values which approximate the monomeric friction coefficient of the polymer. This project has been concerned with the trial of crystal oscillating circuits suitable for driving polymer coated crystals in an atmosphere of penetrant. For these studies done at room temperature, natural rubber was used as an easily applied polymer that is readily penetrated by toluene vapors, qualities anticipated with polyimides when they are tested at T(g) in the presence of toluene. Three quartz crystal oscillator circuits were tested. The simplest circuit used +/- 5 volt dc and had a transistor to transistor logic (TTL) inverter chip that provides a 180 deg phase shift via a feed back loop. This oscillator circuit was stable but would not drive the crystal when the crystal was coated with polymer and subjected to toluene vapors. Removal of a variable resistor from this circuit increased stability but did not otherwise increase performance. Another driver circuit tested contained a two stage differential input, differential output, wide band video amplifier and also contain a feed back loop. The circuit voltage could not be varied and operated at +/- 5 volts dc; this circuit was also stable but failed to oscillate the polymer coated crystal in an atmosphere saturated with toluene vapors. The third oscillator circuit was of similar construction and relied on the same video amplifier but allowed operation with variable voltage. This circuit would drive the crystal when the crystal was submerged in liquid toluene and when the crystal was coated with polymer and immersed in toluene vapors. The frequency readings obtained when using this oscillating circuit are highly variable. This circuit requires further modification to stabilize frequency readings before its use in studies to determine the diffusion coefficient of penetrant molecules into a polymer film coated on a QCM.

Bechtold, Mary M.↗

Cost Models for MMC Manufacturing Processes

Processes for the manufacture of advanced metal matrix composites are rapidly approaching maturity in the research laboratory and there is growing interest in their transition to industrial production. However, research conducted to date has almost exclusively focused on overcoming the technical barriers to producing high-quality material and little attention has been given to the economical feasibility of these laboratory approaches and process cost issues. A quantitative cost modeling (QCM) approach was developed to address these issues. QCM are cost analysis tools based on predictive process models relating process conditions to the attributes of the final product. An important attribute, of the QCM approach is the ability to predict the sensitivity of material production costs to product quality and to quantitatively explore trade-offs between cost and quality. Applications of the cost models allow more efficient direction of future MMC process technology development and a more accurate assessment of MMC market potential. Cost models were developed for two state-of-the art metal matrix composite (MMC) manufacturing processes: tape casting and plasma spray deposition. Quality and Cost models are presented for both processes and the resulting predicted quality-cost curves are presented and discussed.

Elzey, Dana M.↗

Stability Enhancement of Polymeric Sensing Films Using Fillers

Experiments have shown the stability enhancement of polymeric sensing films on mixing the polymer with colloidal filler particles (submicron-sized) of carbon black, silver, titanium dioxide, and fumed silicon dioxide. The polymer films are candidates for potential use as sensing media in micro/nano chemical sensor devices. The need for stability enhancement of polymer sensing films arises because such films have been found to exhibit unpredictable changes in sensing activity over time, which could result in a possible failure of the sensor device. The changes in the physical properties of a polymer sensing film caused by the sorption of a target molecule can be measured by any of several established transduction techniques: electrochemical, optical, calorimetric, or piezoelectric, for example. The transduction technique used in the current polymer stability experiments is based on piezoelectric principles using a quartz-crystal microbalance (QCM). The surface of the QCM is coated with the polymer, and the mass uptake by the polymer film causes a change in the oscillating frequency of the quartz crystal. The polymer used for the current study is ethyl cellulose. The polymer/ polymer composite solutions were prepared in 1,3 dioxolane solvent. The filler concentration was fixed at 10 weight percent for the composites. The polymer or polymer composite solutions were cast on the quartz crystal having a fundamental frequency of about 6 MHz. The coated crystal was subjected to a multistage drying process to remove all measurable traces of the solvent. In each experiment, the frequency of oscillation was measured while the QCM was exposed to clean, dry, flowing air for about 30 minutes, then to air containing a known concentration of isopropanol for about 30 minutes, then again to clean dry air for about 30 minutes, and so forth. This cycle of measurements for varying isopropanol concentrations was repeated at intervals for several months. The figure depicts some of the sensing film stability results for ethyl cellulose polymer, ethyl cellulose-carbon black, and ethyl cellulose-silicon dioxide composite systems. An ethyl cellulose film exhibited a marked decline in response in the first few months of study and settled to a steady average response after about four months. However, response varied widely around the average response for ethyl cellulose film. In contrast, ethyl cellulose- carbon black and ethyl cellulose-silicon dioxide composites also declined in the early months, but showed more repeatable sensing film activity after the initial decline. Similar trends were observed in experiments for ethyl cellulose-titanium dioxide and ethyl cellulose-silver composites.

Lin, Brian↗

Plume mass flow and optical damage distributions for an MMH/N2O4 RCS thruster

The data obtained from two recent experiments conducted in a continuing series of experiments at the Lewis Research Center into the contamination characteristics of a 5-pound thrust MMH/N2O4 engine are presented. The primary objectives of these experiments were to establish the angular distribution of condensible exhaust products within the plume and the corresponding optical damage angular distribution of transmitting optical elements attributable to this contaminant. The plume mass flow distribution was measured by five quartz crystal microbalances (QCM's) located at the engine axis evaluation. The fifth QCM was located above the engine and 15 deg behind the nozzle exit plane. The optical damage was determined by ex-situ transmittance measurements for the wavelength range from 0.2 to 0.6 microns on 2.54 cm diameter fused silica discs also located at engine centerline elevation. Both the mass deposition and optical damage angular distributions followed the expected trend of decreasing deposition and damage as the angle between sensor or sample and the nozzle axis increased. A simple plume gas flow equation predicted the deposition distribution reasonably well for angles of up to 55 degrees. The optical damage measurements also indicated significant effects at large angles.

Spisz, E. W.↗

Skylab electronic technological advancements

The present work describes three electronic devices designed for use in the Skylab airlock module: the teleprinter system, the quartz crystal microbalance contamination monitor (QCM), and the speaker. Design considerations, operation, characteristics, and system development are described for these systems, with accompanying diagrams, graphs, and photographs. The teleprinter is a thermal dot printer used to produce hard copy messages by electrically heating print elements in contact with heat-sensitive paper. The QCM was designed to estimate contamination buildup on optical surfaces of the earth resources experiment package. A vibrating quartz crystal is used as a microbalance relating deposited mass to shifts in the crystal's resonant frequency. Audio devices provide communication between crew members and between crew and STDN, and also provide audible alarms, via the caution and warning system, of out-of-limit-conditions.

Hornback, G. L.↗

Correlation of an optical system degradation with contamination on a critical surface

The loss of sensitivity of a radiantly cooled radiometer during space operation was investigated. A quartz crystal microbalance (QCM), mounted in the proximity of the instrument filter lens and held at its temperature, measured the contaminant at the location during a vacuum test. The temperature cycling of the lens and the QCM verified the contamination of the lens as the cause of the deterioration. Data on the instrument performance in space and in the chamber allowed estimation of the rate of contaminant accretion on the lens in space service. That rate was used to estimate the contaminant partial pressure. The nature of material was inferred by comparison of the partial pressures and the saturated vapor pressures of materials at the temperature of the contaminated surface. These data, in conjunction with data on fields of view of the lens, are used to identify the sources of contamination.

Scialdone, J. J.↗