Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QCM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Gas Dynamics, Characterization, and Calibration of Fast Flow Flight Cascade Impactor Quartz Crystal Microbalances (QCM) for Aerosol Measurements

During recent high altitude flights, we have tested the aerosol section of the fast flow flight cascade impactor quartz crystal microbalance (QCM) on loan to Howard University from NASA. The aerosol mass collected during these flights was disappointingly small. Increasing the flow through the QCM did not correct the problem. It was clear that the instrument was not being operated under proper conditions for aerosol collect ion primarily because the gas dynamics is not well understood. A laboratory study was therefore undertaken using two different fast flow QCM's in an attempt to establish the gas flow characteristics of the aerosol sections and its effect on particle collection, Some tests were made at low temperatures but most of the work reported here was carried out at room temperature. The QCM is a cascade type impactor originally designed by May (1945) and later modified by Anderson (1966) and Mercer et al (1970) for chemical gas analysis. The QCM has been used extensively for collecting and sizing stratospheric aerosol particles. In this paper all flow rates are given or corrected and referred to in terms of air at STP. All of the flow meters were kept at STP. Although there have been several calibration and evaluation studies of moderate flow cascade impactors of less than or equal to 1 L/rein., there is little experimental information on the gas flow characteristics for fast flow rates greater than 1 L/rein.

Grant, J.R.↗

Structural Analysis of the QCM Aboard the ER-2

As a result of recent supersonic transport (SST) studies on the effect they may have on the atmosphere, several experiments have been proposed to capture and evaluate samples of the stratosphere where SST's travel. One means to achieve this is to utilize the quartz crystal microbalance (QCM) installed aboard the ER-2, formerly the U-2 reconnaissance aircraft. The QCM is a cascade impactor designed to perform in-situ, real-time measurements of aerosols and chemical vapors at an altitude of 60,000 - 70,000 feet. The ER-2 is primarily used by NASA for Earth resources to test new sensor systems before they are placed aboard satellites. One of the main reasons the ER-2 is used for this flight experiment is its capability to fly approximately twelve miles above sea level (can reach an altitude of 78,000 feet). Because the ER-2 operates at such a high altitude, it is of special interest to scientists interested in space exploration or supersonic aircraft. Some of the experiments are designed to extract data from the atmosphere around the ER-2. For the current flight experiment, the QCM is housed in a frame that is connected to an outer pod that is attached to the fuselage of the ER-2. Due to the location of the QCM within the housing frame and the location of the pod on the ER-2, the pod and its contents are subject to structural loads. In addition to structural loads, structural vibrations are also of importance because the QCM is a frequency induced instrument. Therefore, a structural analysis of the instrument within the frame is imperative to determine if resonance and/or undesirable deformations occur.

Jones, Phyllis D.↗

Quartz Crystal Microbalance (QCM) monitor of contamination for LES-8/9

A Quartz Crystal Microbalance (QCM) was used to monitor condensable contamination during the launching of two Lincoln Laboratory Experimental Satellites--LES-8 and LES-9. The QCM was installed on the dispenser truss and measured contamination by means of a frequency shift of a quartz crystal oscillator. By using a special crystal cut and a second reference quartz crystal, the sensor had extreme sensitivity and remarkable temperature independence. A 1-Hz frequency shift, which corresponds to 3.5 x 10 to the -9th power g/sq cm was resolved by the flight instrumentation.

Lynch, J. T.↗

Application of Multiharmonic QCM-D for Detection of Plasmin at Hydrophobic Surfaces Modified by β-Casein

Plasmin protease plays an important role in many processes in living systems, including milk. Monitoring plasmin activity is important for control of the nutritional quality of milk and other dairy products. We designed a biosensor to detect the proteolytic activity of plasmin, using multiharmonic quartz crystal microbalance with dissipation (QCM-D). The β-casein immobilized on the hydrophobic surface of 1-dodecanethiol on the AT-cut quartz crystal was used to monitor plasmin activity. We demonstrated detection of plasmin in a concentration range of 0.1–20 nM, with the limit of detection about 0.13 ± 0.01 nM. The analysis of viscoelastic properties of the β-casein layer showed rapid changes of shear elasticity modulus, μ, and coefficient of viscosity, η, at plasmin sub-nanomolar concentrations, followed by modest changes at nanomolar concentrations, indicating multilayer architecture β-casein. A comparative analysis of viscoelastic properties of β-casein layers following plasmin and trypsin cleavage showed that the higher effect of trypsin was due to larger potential cleavage sites of β-casein.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Delineating Confinement Regimes for Nafion Thin Films via Simultaneous QCM-D and Spectroscopic Ellipsometry

Proton-conducting ionomers used in electrodes of electrochemical devices form nanometer-scale films covering metallic catalyst surfaces, wherein they experience confinement and interfacial effects absent in the bulk polymer. This confinement alters the physical properties of the ionomer film, which is postulated to increase the density and is attributed to the transport limitations observed in fuel-cell electrodes. Despite studies showing reduced swelling, no systematic measurement has validated this phenomenon by demonstrating both densification and stiffening as the film gets thinner. Here, this study aims to fill this gap by reporting the humidity-driven changes in swelling, mass uptake, and density of Nafion ionomer films cast at varying thicknesses (10–320 nm) onto a gold-plated sensor. The films were simultaneously probed during humidification using spectroscopic ellipsometry (SE) and a quartz crystal microbalance with dissipation (QCM-D), which allowed for determination of the density and shear stiffness. The effects of confinement were prominently observed below ∼30 nm, with films showing increased density along with decreased swelling and mass uptake during hydration. In addition, the confined films show a negative excess volume upon initial water sorption, implying a larger proportion of absorbed water might bound to ionic groups in accord with notion of localized densification.

Espinet, Kevin B. [University of California, Berke↗

Performance of a flight qualified, thermoelectrically temperature controlled QCM sensor with power supply, thermal controller and signal processor

A thermoelectrically temperature controlled quartz crystal microbalance (QCM) system was developed for the measurement of ion thrustor generated mercury contamination on spacecraft. Meaningful flux rate measurements dictated an accurately held sensing crystal temperature despite spacecraft surface temperature variations from -35 C to +60 C over the flight temperature range. An electronic control unit was developed with magentic amplifier transformer secondary power supply, thermal control electronics, crystal temperature analog conditioning and a multiplexed 16 bit frequency encoder.

Wallace, D. A.↗

QCM Thermo-Gravimetric Analysis (QTGA) Comparisons

The ASTM E-1559 apparatus has been used for years at NASA/Goddard Space Flight Center (GSFC) to determine in situ outgassing rate information, as well as pertinent in situ TML and multiple VCM values. The apparatus also affords the opportunity to experimentally compute the evaporation rates of molecular species that are reemitted as the Quartz Crystal Microbalances (QCMs) are gradually warmed up at some controlled temperature. Typically the molecular mass that accumulates onto the test QCMs are a compilation of species that are outgassing from the sample due to their respective activation energies and the desorption processes that the sample undergoes at various tested temperatures. It has been speculated that if there is too much molecular buildup of condensed water vapor (ice) onto the QCM crystal that a significantly higher temperature would be needed to break these "ice" bonds. ASTM E-1559 data plots will be used to demonstrate the thermogravimetric effects of water and other miscible molecular species with various water/ice thicknesses and at different evaporation rates.

Rosecrans, Glenn↗

ASTM E 1559 method for measuring material outgassing/deposition kinetics has applications to aerospace, electronics, and semiconductor industries

The American Society for Testing and Materials has published a new standard test method for characterizing time and temperature-dependence of material outgassing kinetics and the deposition kinetics of outgassed species on surfaces at various temperatures. This new ASTM standard, E 1559(1), uses the quartz crystal microbalance (QCM) collection measurement approach. The test method was originally developed under a program sponsored by the United States Air Force Materials Laboratory (AFML) to create a standard test method for obtaining outgassing and deposition kinetics data for spacecraft materials. Standardization by ASTM recognizes that the method has applications beyond aerospace. In particular, the method will provide data of use to the electronics, semiconductor, and high vacuum industries. In ASTM E 1559 the material sample is held in vacuum in a temperature-controlled effusion cell, while its outgassing flux impinges on several QCM's which view the orifice of the effusion cell. Sample isothermal total mass loss (TML) is measured as a function of time from the mass collected on one of the QCM's which is cooled by liquid nitrogen, and the view factor from this QCM to the cell. The amount of outgassed volatile condensable material (VCM) on surfaces at higher temperatures is measured as a function of time during the isothermal outgassing test by controlling the temperatures of the remaining QCM's to selected values. The VCM on surfaces at temperatures in between those of the collector QCM's is determined at the end of the isothermal test by heating the QCM's at a controlled rate and measuring the mass loss from the end of the QCM's as a function of time and temperature. This reevaporation of the deposit collected on the QCM's is referred to as QCM thermogravimetric analysis. Isothermal outgassing and deposition rates can be determined by differentiating the isothermal TML and VCM data, respectively, while the evaporation rates of the species can be obtained as a function of temperature by differentiating the QCM thermogravimetric analysis data.

Garrett, J. W.↗

Cost Models for MMC Manufacturing Processes

The quality cost modeling (QCM) tool is intended to be a relatively simple-to-use device for obtaining a first-order assessment of the quality-cost relationship for a given process-material combination. The QCM curve is a plot of cost versus quality (an index indicating microstructural quality), which is unique for a given process-material combination. The QCM curve indicates the tradeoff between cost and performance, thus enabling one to evaluate affordability. Additionally, the effect of changes in process design, raw materials, and process conditions on the cost-quality relationship can be evaluated. Such results might indicate the most efficient means to obtain improved quality at reduced cost by process design refinements, the implementation of sensors and models for closed loop process control, or improvement in the properties of raw materials being fed into the process. QCM also allows alternative processes for producing the same or similar material to be compared in terms of their potential for producing competitively priced, high quality material. Aside from demonstrating the usefulness of the QCM concept, this is one of the main foci of the present research program, namely to compare processes for making continuous fiber reinforced, metal matrix composites (MMC's). Two processes, low pressure plasma spray deposition and tape casting are considered for QCM development. This document consists of a detailed look at the design of the QCM approach, followed by discussion of the application of QCM to each of the selected MMC manufacturing processes along with results, comparison of processes, and finally, a summary of findings and recommendations.

Elzey, Dana M.↗

Edge fluctuation measurements in EDA H-mode and QCE plasmas in ASDEX Upgrade using the correlation electron cyclotron emission diagnostic

The requirement of a plasma solution without large edge-localized modes (ELMs) for future fusion devices motivates the study of plasmas without Type I ELMs. The enhanced D–α (EDA) and quasi-continuous exhaust (QCE) scenarios are two such Type I ELM free plasmas, but their underlying physics principles are not fully understood. A database of EDA and QCE plasmas from ASDEX Upgrade was compiled and analyzed using the correlation electron cyclotron emission diagnostic in order to study differences between properties of the quasi-coherent mode (QCM) between these two regimes. Investigations into measured spectral properties of the QCM, radiated temperature fluctuations δT rad /T rad , and radial correlation lengths L c showed no differences between the two regimes. Spectral properties using the cross-power spectral density, G xy were similar between regimes, with the values measured to be a central frequency, $f$ $QCM$ ≈ 20 - 50 kHz; spectral width, Δ $f$ ≈ 5 - 40 kHz; δT rad /T rad ≈ 4-6%; and L c ≈ 1-2 cm. Investigations into a quantity representing the relative bandwidth Δ$f$/$f$ $QCM$ revealed differences between EDA and QCE plasmas when plotted radially, suggesting some type of interaction between the QCM in QCE plasmas with the surrounding broadband turbulence that is not present in EDA phases. Additionally, investigations into various drive terms for hypothesized instability drivers for the QCM are performed showing no difference in the parameter spaces of collisionality and the ion temperature, electron temperature, or electron pressure scale lengths between each regime indicating that there is no observable difference between the drive behind the QCM in each regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ELM-free enhanced D α H-mode with near zero NBI torque injection in DIII-D tokamak

Enhanced D α H-mode (EDA H-mode), an ELM-free H-mode regime, and the concomitant quasi-coherent mode (QCM) are explored in neutral beam heated, lower single null plasmas with near zero external torque injection. This regime exhibits good energy confinement (H 98y2 ~ 1) with β N ~ 2, high density, regime access at low input power, and no ELMs. New time–resolved measurements of electron and ion density, temperature, plasma rotation, and radial electric field as well as turbulence, flows, thermal and particle transport, and linear instability calculations examining the dynamics of the QCM are presented. Measurements using multiple fluctuation diagnostics reveal the QCM to be a separatrix spanning mode, peaking just inside the separatrix, existing in a wide range of k ⊥ ρ s ~ 0.1–1.2 with multiple harmonics, and propagating with a very small phase velocity in the plasma frame, where k ⊥ is the binormal wavenumber and ρ s is the ion sound radius. Linear gyrokinetic simulations of this EDA H-mode discharge with CGYRO indicate that the trapped electron mode (TEM) and electron temperature gradient mode are the dominant instabilities in the radial region where QCM is also unstable. Qualitative analysis indicates that the properties of TEM are consistent with the experimentally observed characteristics of the QCM. These similarities suggest that the QCM is consistent with a TEM instability existing in the edge region of the EDA H-mode plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Remote quantum state transfer for qubits with different frequencies

A quantum communication system includes a first quantum transceiver, a second quantum transceiver, and a quantum communication mediator (QCM) system. The transceivers have different resonant frequencies or physical systems. The QCM system receives an initial quantum signal from the first quantum transceiver. The QCM system transfers a quantum state of the initial quantum signal to a first mechanical signal and then from the first mechanical signal to a first pair of optical signals by way of a first three-wave mixing process. The QCM transfers the quantum state to a second pair of optical signals from the first pair by way of a four-wave mixing process. The QCM transfers the quantum state from the second pair of optical signals to a second mechanical signal by way of a second three-wave mixing process. The QCM transfers the quantum state from the second mechanical signal to a final quantum signal by mechanical transduction.

Soh, Daniel Beom Soo↗

Structural Loading on the QCM/SAW Instrument Aboard the ER-2 Used for Atmospheric Testing

Several experiments have been proposed to capture and evaluate samples of the atmosphere where SST's travel. One means to achieve this is to utilize the quartz crystal microbalance (QCM) / surface acoustical wave (SAW) instrument installed aboard the ER-2, formerly the U-2 reconnaissance aircraft. The QCM is a cascade impactor designed to perform in-situ, real-time measurements of aerosols and chemical vapors at an altitude of 60,000-70,000 feet. The primary use of the ER-2 is by NASA for Earth resources to test new sensor systems before being placed aboard satellites. One of the main reasons the ER-2 is used for this flight experiment is its capability to fly approximately twelve miles above the sea level (can reach an altitude of 78,000 feet). Because the ER-2 operates at such a high altitude, it is of special interest to scientists interested in space exploration or supersonic aircraft. The purpose of some of the experiments is to extinct data from the atmosphere around the ER-2. For the current CSTEA flight experiment, the housing of the QCM is in a frame that connects to an outer pod that attaches to the fuselage of the ER-2. Due to the location of the QCM within the housing frame and the location of the pod on the ER-2, the pod and its contents are subject to structural loads. In addition to structural loads, structural vibrations are also of importance because the QCM output data is based on the determination of beat frequencies between a pair of oscillators (one coated, the second uncoated, according to the chemical reaction being monitored). A structural analysis of this system can indicate whether potential resonances may exist between the (higher) structural modal frequencies and the beat frequencies. In addition undesirable deformations may result due to maximum expected static or dynamic loads during typical flight conditions. If the deformations are excessive they may adversely affect the accuracy the instrumentation output.

Bainum, Peter M.↗

Post-flight analyses of the crystals from the M0003-14 quartz crystal microbalance experiment

Quartz Crystal Microbalances constructed by QCM Research were flown on the leading and trailing edges of the Long Duration Exposure Facility (LDEF) as one of the sub-experiments of M0003. Response of the crystals coated with 150 A of IN2O3ZnS was recorded during the first 424 days of the mission. A second QCM with crystals coated with 150 A was also flown but not monitored. The flight data and temperature profiles will be presented. After the flight, the QCM's were disassembled and analyzed. The samples included the crystals from the leading and trailing edge samples of both types of coatings along with the reference crystals which were inside the QCM housing. Analyses were performed by scanning electron microscopy, energy dispersive x ray analysis, x ray photoelectron spectroscopy, ion microprobe mass analysis, and reflectance spectroscopy in the infrared and ultraviolet/visible region. The crystals were contaminated predominantly with silicone compounds. The contamination is higher on the leading edge than on the trailing edge, and higher on the exposed crystal than on the reference crystals. No significant differences in composition of the In2O3 crystals were noted. Differences in the reflectance and surface analysis of the Zns crystals will be discussed.

Stuckey, W. K.↗

Post-flight analyses of the crystals from the M0003-14 quartz crystal microbalance experiment

Quartz Crystal Microbalances constructed by QCM Research were flown on the leading and trailing edges of LDEF as one of the sub-experiments of M0003. Response of the crystals coated with 150 A of In2O3 was recorded during the first 424 days of the mission. A second QCM with crystals coated with 150 A of ZnS was also flown but not monitored. After the flight, the QCM's were disassembled and analyzed in The Aerospace Corporation laboratories. The samples included the crystals from the leading and trailing edge samples of both types of coatings along with the reference crystals, which were inside the QCM housing. Analyses were performed by scanning electron microscopy, energy dispersive x-ray analyses, x-ray photoelectron spectroscopy, ion microprobe mass analysis, and reflectance spectroscopy in the infrared and UV/visible regions. The crystals are contaminated predominantly with silicone compounds. The contamination is higher on the leading edge than on the trailing edge and higher on the exposed crystals than on the reference crystals.

Stuckey, W. K.↗

Mass Loading Characteristics of Crystal Clock Oscillators

The 10-MHz piezoelectric quartz-crystal microbalance (QCM) has been used extensively for stratospheric aerosol sampling. We have undertaken laboratory studies of the QCM response to mass loading by trace gases. However, this device requires dual oscillator circuitry and the mass sensitivity can often be affected by the electronics. The coatings on the quartz crystals are sometimes difficult to remove after they have reacted with a particular gas and a disposable crystal system would be desirable. The cost of the dual oscillator-based QCM makes this a prohibitive option. Since our goal is to develop a cost-effective microbalance system with stable electronics we have begun testing of crystal clock oscillators, which are assembled with their own circuitry. We have been using chemically specific coatings for ozone to determine if the sensitivity and mass-frequency ratios are comparable to that of the 10-MHz QCM.

Cobb, Janel↗

Material Outgassing, Identification and Deposition, MOLIDEP System

The outgassing tests are performed employing a modified vacuum operated Cahn analytical microbalance, identified as the MOLIDEP system. The test measures under high vacuum, the time varying Molecular mass loss of a material sample held at a chosen temperature; it Identifies the outgassing molecular components using an inline SRS 300 amu Residual Gas Analyzer (RGA) and employs a temperature controlled 10 MHz Quartz Crystal Microbalance (QCM) to measure the condensable DEPosits. Both the QCM and the RGA intercept within the conductive passage the outgassing products being evacuated by a turbomolecular pump. The continuous measurements of the mass loss, the rate of loss, the sample temperature, the rate of temperature change, the QCM temperature and the QCM recorded condensable deposits or rate of deposits are saved to an Excel spreadsheet. A separate computer controls the RGA.

Scialdone, John J.↗