The High Luminosity Large Hadron Collider is a planned upgrade to the LHC that will allow it to take up to 7 times as much data. Upgrades to all detector systems, including the Outer Tracker, are necessary to allow them to handle the increased radiation and pileup. Fermilab has been tasked with assembling modules for the Outer Tracker system. This presentation discusses the QA tests performed on these modules and the integration procedure required to ensure all modules work in sync. The QA tests include sensor IV curves, MaPSA testing, visual inspection, skeleton testing, and module testing. There are additional tests that can only be performed on integrated modules that are working in sync, and developing an understanding of the timing and latency of the modules is necessary to perform this synchronization.
The High Luminosity Large Hadron Collider is a planned upgrade to the LHC that will allow it to take up to 7 times as much data. Upgrades to all detector systems, including the Outer Tracker, are necessary to allow them to handle the increased radiation and pileup. Fermilab has been tasked with assembling modules for the Outer Tracker system. This presentation discusses the QA tests performed on these modules and the integration procedure required to ensure all modules work in sync. The QA tests include sensor IV curves, MaPSA testing, visual inspection, skeleton testing, and module testing. There are additional tests that can only be performed on integrated modules that are working in sync, and developing an understanding of the timing and latency of the modules is necessary to perform this synchronization.
To investigate fully balanced steady-state free precession (bSSFP) with optimized acquisition protocols for magnetic resonance imaging (MRI)-based postimplant quality assessment of low-dose-rate (LDR) prostate brachytherapy without an endorectal coil (ERC).
Flexible PCB quench antennas have been very useful in providing high-quality high-resolution data in low temperature superconducting magnet tests. Similar multi-sensor arrays have been employed recently to cover a high temperature superconductor magnet tested at FNAL. In the present work, data taking conditions and magnet features to support the analysis framework are discussed. Then observations made during complete magnet powering cycles are described and analysis of quench antenna data are presented. Based on results, improvements to instrumentation and data taking are debated. Views on the future of flexible quench antenna sensors for HTS magnet diagnostics and operational support are shared.
The Sandia National Laboratories (SNL) staff is meeting the requirements of Nuclear Fuel Cycle and Supply Chain (NFCSC) Quality Assurance Program Document (QAPD). Each of the NFCSC FY 19 packages for SNL were reviewed. Minor errors were identified with regard to one package for the previous version of this report. Those are being rectified and future instances will indicate the appropriate entries. Aside from the minor discrepancies noted, there were no quality assurance findings this fiscal year for the NFCSC program. In particular, all of the Quality Rigor Level (QRL) level assignments were confirmed to be appropriate.
The Sandia National Laboratories (SNL) staff is meeting the requirements of the Nuclear Fuel Cycle and Supply Chain (NFCSC) Quality Assurance Program Document (QAPD)1. Each of the 46 SFWD FY 19 packages for SNL were reviewed. Six of the 46 packages had incorrect QRL categories, but technical reviews were always found to be appropriate. No major corrective actions are assigned, but recommendations have been made to adjust the identified QRL items. Additional and minor PICS:NE checkbox errors are recognized. Future training will be geared to ensure proper QRL categorizations and other check box entries in future cases
The Sandia National Laboratories (SNL) staff is meeting the requirements of the Nuclear Fuel Cycle and Supply Chain (NFCSC) Quality Assurance Program Document (QAPD). Each of the 5 NFCSC FY 20 packages for SNL were reviewed. None of the 5 packages had incorrect QRL categories. No major corrective actions are assigned. Additional and minor PICS:NE checkbox errors may exist, but none were identified in this assessment. Training is now also geared to encourage WPMs to take credit for optional technical reviews by considering setting the QRL level to 3. This is because when the level is set to 4, the PICS:NE system does not provide fields for review information. Finally, training in the NFCSC QAPD has been delivered as always to WPMs.
The purpose of this Packaging and Transportation Safety Functional Area (PTSFA) procedure is to describe the process in which the PTSFA Quality Assurance Engineer (QAE) or designee reviews and approves the documentation associated with the procurements of containers to be used for onsite transfer or off-site transportation of hazardous materials and waste.
Flexible PCB quench antennas have been very useful in providing high-quality high-resolution data in low temperature superconducting magnet tests. Similar multi-sensor arrays have been employed recently to cover a high temperature superconductor magnet tested at FNAL. In the present work, data taking conditions and magnet features to support the analysis framework are discussed. Then observations made during complete magnet powering cycles are described and analysis of quench antenna data are presented. Based on results, improvements to instrumentation and data taking are debated. Views on the future of flexible quench antenna sensors for HTS magnet diagnostics and operational support are shared.
Explore the source record for details and available documents.
INL performed targeted oxidation tests to measure oxidation rates for samples of ET-10 and ETU-10 graphite under CRADA No. 21CRA22 Mod. 3, Annex A, “Tritium Testing to Support Kairos Power Advanced Reactor Demonstration” (04/02/2024). All testing was conducted within INL’s Carbon Characterization Laboratory (CCL) using test standard ASTM D7542-21 "Standard Test Method for Air Oxidation of Carbon and Graphite in the Kinetic Regime" [ASTM International, 2021]. Kairos Power provided all test specimens through its graphite vendor Ibiden, Inc. to INL and ASTM specimen specified dimensions. Information within this report only provides the Arrhenius oxidation rate plots as a function of temperature for each graphite grade tested. The raw mass loss per time data will be provided on the Nuclear Data Management and Analysis System (NDMAS) portal located on the INL information system.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high-coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.