Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pool boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

Enhanced pool boiling heat transfer using novel inverted trapezoid microgroove structures

Pool boiling heat transfer improvements with enhanced surfaces have been extensively studied for various hydrofluorocarbon (HFC) refrigerants. However, there is a limited number of studies in the open literature that focus on the pool boiling heat transfer characteristics of hydrofluoroolefin (HFO) refrigerants on enhanced surfaces. This study aims to address this gap by analyzing the pool boiling behavior of HFO refrigerants, specifically R1234yf and R1234ze(E). Experiments were conducted on both plain surfaces and novel inverted trapezoid microgroove structures. Further, the experimental results indicate that the microgroove structures can improve heat transfer coefficients by up to 80% compared to plain surfaces. Additionally, the performance of R1234yf and R1234ze(E) was compared to that of R134. It was observed that R1234yf exhibited comparable performance to R134a, while R1234ze(E) showed slightly lower performance. To assess the influence of saturation temperature on pool boiling heat transfer, tests were conducted at different saturation temperatures of 15℃, 25℃, and 35℃. The findings revealed that the pool boiling heat transfer coefficient increases with rising saturation temperature.

42 ENGINEERING↗

Interface Capturing Simulations on Pool Boiling Performance With Multiple Nucleation Sites

High-fidelity pool boiling simulations can provide a numerical database for improving mechanistic boiling models by allowing for specific evaluation of interactions among bubbles. Previously published pool boiling simulations investigated two nucleation sites in which bubble growth at one site suppressed nucleation at the other site. Based on previous study results, more complicated interface-capturing simulations on pool boiling were conducted using PHASTA code with locally refined unstructured mesh.First, different boundary conditions (BCs) were assessed to support robustness and reproducibility of the boiling model. Then, a scale study was conducted at a larger domain with nine nucleation sites, four of which were activated. Involving more nucleation sites increased the complexity of bubble interactions from surrounding sites. Finally, bubble departure behavior influenced by wall heat flux was investigated. When heat flux was increased, the order of bubble departure changed, but diagonal bubbles always departed after one another. The departure time interval between the first and second bubble reduced as heat flux increased. The corresponding frequency was almost linearly proportional to the heat flux. In addition, bubble departure behavior was found to be greatly influenced by the nucleation site pattern. Multiple nucleation sites resulted in superimposed inhibitive effects from surrounding sites to each bubble, which extensively delayed the departure.The work presented here provides new insight on the fundamental understanding of boiling phenomena, contributes to the development of a 3D multiphase computational fluid dynamics (M-CFD) model, and provides a more comprehensive database for data-driven pool boiling studies.

Fan, Joy↗

Enhanced Pool Boiling of Low-Pressure Refrigerants on Round Tubes- An Experimental Evaluation

Pool boiling heat transfer is one of the most effective heat transfer methos and crucial for several energy conversion processes such as electronic cooling, steam generation, water purification and thermal management. Enhancing boiling heat transfer around the tubes enables higher heat flux, which can improve the efficiency and lead to compact heat exchangers. Delaying the onset of critical heat flux (CHF) allows for higher CHFs and protects equipment during anomalous transient conditions. Growing interest in process intensification and delayed CHF has motivated the current study. An experimental approach has been deployed to investigate a potential technique to enhance the pool boiling performance around small diameter tubes by open cell metal foams. The findings for nucleate pool boiling of Novec HFE 7000 on the externally enhanced and smooth tubes are reported. The enhanced tube comprised of compressed aluminum foam brazed around. All the samples were horizontally oriented, and the experiments were performed under ambient pressure conditions. The heat transfer measurements for the smooth tubes were compared with several existing correlations and established the baseline. The preliminary results showed that the aluminum foam effectively enhanced the heat transfer coefficient and delayed the onset of critical heat flux. In addition, the pool boiling process around the round tube sample was visualized from both side and front views to comprehend the heat transfer mechanisms underlying substantial enhancement observed during experiments.

Yang, Cheng-Min↗

Augmentation of pool boiling heat transfer on tube bundles using metal foam

Pool boiling on a tube bundle is one of the most important heat transfer modes in several industrial applications, including steam generators, shell and tube heat exchangers for waste heat recovery, and desalination. Although several enhanced tubes (e.g., external micro-finned tubes) have been extensively studied and commercialized, the studies that pertain to the metal foam enhanced tube bundles are limited in the open literature. The objective of the present study is to perform an experimental study to analyze the pool boiling heat transfer characteristics of a metal foam tube bundle and compare its performance with that of a tube bundle with no enhancement. The performance of the metal foam tube bundles with different porosities (81%, 75%, and 62%) is compared against the conventional bare tube bundle. The results showed that the heat transfer coefficients of the metal foam tube bundles are 100–212% higher than those of the bare tube bundle. Among the different porosities, metal foam with 75% porosity showed a higher heat transfer coefficient. Furthermore, the wall temperature of the metal foam tubes is nearly 5–14⁰C lower than that of the bare tubes. In conclusion, when compared with a tube pitch of 25.4 mm, a tube pitch of 19.05 mm showed a maximum of 9% and 14% enhancement in bare and metal foam tube bundles, respectively.

42 ENGINEERING↗

High-fidelity pool boiling simulations on multiple nucleation sites using interface capturing method

Boiling has proved to be one of the most efficient means for heat transfer and is a very important phenomenon during severe accident scenarios in light water reactors. High-fidelity pool boiling simulations can provide a numerical database for improving mechanistic boiling models by allowing for specific evaluation of interactions among bubbles. Previously published pool boiling simulations investigated two nucleation sites in which bubble growth at one site suppressed nucleation at the other site. Based on previous study results, more complicated interface-capturing simulations on pool boiling were conducted using PHASTA code with locally refined unstructured mesh. First, different boundary conditions (BCs) were assessed to support robustness and reproducibility of the boiling model. Then, a scale study was conducted at a larger domain with nine nucleation sites where either nine or four nucleation sites are activated. Involving more nucleation sites increased the complexity of bubble interactions from surrounding sites. Finally, bubble departure behavior influenced by wall heat flux was investigated. In this work, when heat flux was increased, the order of bubble departure changed, but diagonal bubbles always departed after one another. The departure time interval between the first and second bubble reduced as heat flux increased. The corresponding frequency was almost linearly proportional to the heat flux. In addition, bubble departure behavior was found to be greatly influenced by the nucleation site pattern. Multiple nucleation sites resulted in superimposed inhibitive effects from surrounding sites to each bubble, which extensively delayed the departure. This new observation was not discussed in previously published works. The work presented here provides new insight on the fundamental understanding of boiling phenomena, contributes to the development of a 3D multiphase computational fluid dynamics (M-CFD) model, and provides a more comprehensive database for data-driven pool boiling studies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced pool boiling heat transfer with metal foam tubes in inline tube bundle configuration

Flooded evaporators, commonly known as shell-and-tube heat exchangers, are widely used in large-scale industrial refrigeration and air-conditioning systems due to their high pool boiling heat transfer efficiency. However, their bulky configuration requires a large refrigerant inventory, which poses safety challenges—particularly when employing next-generation A2L refrigerants that are mildly flammable. Here, to address this issue, the development of compact heat exchangers with enhanced heat transfer performance is essential. In this study, a novel metal foam tube design is proposed to augment pool boiling heat transfer. Experiments were conducted at a saturation temperature of 20 °C and across a heat flux range of 7–60 kW m −2 . The tests were conducted for both smooth and metal foam tubes with an inline tube bundle configuration and for a pitch–to–diameter (P/D) ratios of 1.3 and 1.5. Pool boiling performance was evaluated for next-generation hydrofluoroolefin (HFO) refrigerants, R1234yf and R1234ze(E), with R134a serving as the baseline fluid. The results indicate that the heat transfer coefficient (HTC) of R1234yf is comparable to R134a, while R1234ze(E) shows slightly lower performance. Importantly, the metal foam tubes achieved up to a 217% enhancement in HTC compared to smooth tubes.

Metal foam tubes↗

Alteration of pool boiling heat transfer on metallic surfaces by in situ oxidation

The critical heat flux during pool boiling has been investigated for a range of applications including electrical power generation and thermal management. Reported experimental CHF values during pool boiling of water on flat metallic surfaces, however, show a large discrepancy across studies. Here, we address this discrepancy in CHF values by accounting for oxidation of metallic surfaces during boiling. We studied the effect of in situ oxidation on flat Cu and Ni surfaces by changing the duration that samples were held in saturated water before conducting boiling experiments. The morphology and chemical composition of surfaces after the boiling experiments were analyzed by atomic force microscopy and X-ray photoelectron spectroscopy, respectively. Cu surfaces showed gradually increasing CHF values as the duration in saturated water increased, which could be attributed to the increase in roughness due to the formation of Cu 2 O nanostructures. Conversely, Ni surfaces showed relatively stable CHF and morphology as a nearly flat layer of NiO formed, with one exception: formation of a highly wetting hydroxide, Ni(OH) 2 , on a Ni coupon held in saturated water for 24 h resulted in a uniquely high CHF value, signifying the importance of surface chemistry in addition to morphology. Finally, the fundamental mechanisms resulting in the wide spread of CHF values on metallic surfaces elucidated in this work will lead to more accurate estimation of CHF as well as a deeper mechanistic understanding of CHF values on engineered surfaces.

42 ENGINEERING↗

Heat transfer and visual observation of pool boiling of next-generation low-pressure refrigerant: R1336mzz(Z)

R1336mzz(Z) is a non-flammable and non-toxic hydrofluoroolefin (HFO), which is a potential alternative working fluid for multiple applications such as centrifugal chillers, industrial high temperature heat pumps, and Organic Rankine Cycles. Pool boiling is one of the primary heat transfer modes in shell-and-tube evaporators, and there is limited data for R1336mzz(Z) due to its recent introduction. This study investigated the pool boiling characteristics of R1336mzz(Z) using a closed-loop apparatus. Heat transfer coefficients on a smooth aluminum surface were measured at various heat fluxes with a heating block, and the results were compared to predictions from various correlations. Additionally, a high-speed camera was employed to visualize and analyze the pool boiling behavior of this next-generation low-pressure refrigerant.

Yang, Cheng-Min [ORNL]↗

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opal (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10 ..mu..m thick CuIOs with 4.8 ..mu..m diameter, covering silicon substrate of area 11 mm x 11 mm, with various heated areas ranging from 2.5 mm x 2.5 mm to 10 mm x 10 mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 Wcm -2 for 3-to-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5 mm x 2.5 mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 Wcm -2 with a superheat ~ 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition (ALD) aluminum oxide (Al 2 O 3 ) in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures: Preprint

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opals (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10-micrometer-thick CuIOs with 4.8-micrometer diameter, covering silicon substrate of area 11-mm by 11-mm, with various heated areas ranging from 2.5-mm by 2.5-mm to 10-mm by 10-mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 watts per square cm for 3-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5-mm by 2.5-mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 watts per square cm with a superheat of approximately 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition of aluminum oxide in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Unified descriptor for enhanced critical heat flux during pool boiling of hemi-wicking surfaces

Boiling heat transfer is dictated by interfacial phenomena at the three-phase contact line where vapor bubbles form on the surface. Structured surfaces have shown significant enhancement in critical heat flux (CHF) during pool boiling by tailoring interfacial phenomena. This CHF enhancement has been primarily explained by two structural effects: roughness, which extends the contact line length at the bubble base, and wickability, the ability to imbibe liquid through surface structures by capillary pumping. Here, in this work, we show that CHF enhancement on structured surfaces cannot be described by roughness or wickability alone. This result was confirmed using systematically designed micropillar surfaces with controlled roughness and wickability. Further, we performed a scaling analysis and derived a unified descriptor, which represents the combined effects of thin film density and volumetric wicking rate. This unified descriptor shows a reasonable correlation with CHF values with our experiments and literature data. This work provides important insights in understanding the role of surface structures on CHF enhancement, thereby providing guidelines for the systematic design of surface structures for enhanced pool boiling heat transfer.

42 ENGINEERING↗

Multi-GPU porting of a phase-change cascaded lattice Boltzmann method for three-dimensional pool boiling simulations

The Lattice Boltzmann method (LBM) has proven effective in simulating phase-change phenomena, such as melting, solidification, evaporation, and boiling. In this work, we develop a highly parallelized multi-GPU implementation of LBM for three-dimensional pool boiling simulations. The code is based on the OpenACC programming model, which enables the code to be deployed efficiently on multi-core CPUs, GPUs, and potentially other accelerators, without the need for architecture-specific rewrites. To support large-scale simulations, the domain is decomposed and distributed across multiple compute nodes using MPI. We demonstrate that the code exhibits excellent scaling properties, with ideal strong-scaling running with up to 256 GPUs on the MareNostrum5 cluster.

97 MATHEMATICS AND COMPUTING↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

Pool boiling heat transfer characteristics of low-GWP refrigerants in a horizontal tube bundle configuration

Heat transfer enhancement techniques have been adapted on the shell side to improve the overall performance of the flooded evaporators, such as finned tubes. In recent years, it has been demonstrated that the metal foam structure can offer enhanced heat transfer performance under pool boiling conditions. However, there are not much research in the open literature that examine the feasibility of metal foam embedded tubes in horizontal tube bundle configurations. Therefore, this paper proposed a novel metal foam embedded tube (i.e., foam embedded outside the tube) to improve the heat transfer behavior of flooded evaporators. Further, the experiments were performed on a horizontal tube bundle with a staggered arrangement. Moreover, the performance of low global warming potential (GWP) refrigerants (R-1234yf and R-1234ze(E)) is compared against R-134a for both plain tubes and metal foam tubes with porosities of 81%, 75%, and 62%. The results showed that a metal foam tube with a porosity of 62% showed a maximum heat transfer coefficient (HTC) enhancement of 291% compared to the plain tube. As compared with R-134a, the HTCs of R-1234yf and R-1234ze(E) are nearly 10% higher and 5% lower, respectively.

42 ENGINEERING↗