Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plugs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Commercial Building Plug Load Management System that Uses Internet of Things Technology to Automatically Identify Plugged-In Devices and Their Locations

Plug and process loads (PPLs) account for a large portion of U.S. commercial building energy use. There is a huge potential to reduce whole building consumption by targeting PPLs for energy savings measures or implementing some form of plug load management (PLM). Despite this potential, there has yet to be a widely adopted commercial PLM technology. This paper describes the Automatic Type and Location Identification System (ATLIS), a PLM system framework with automatic and dynamic load detection (ADLD). ADLD gives PLM systems the ability to automatically identify devices as they are plugged into the outlets of a building. The ATLIS framework takes advantage of smart, connected devices to identify device locations in a building, meter and control their power, and communicate this information to a central database. ATLIS includes five primary capabilities: location identification, communication, control, energy metering, and data storage. A laboratory proof of concept (PoC) demonstrated all but the energy metering capability, and these capabilities were validated using a series of system tests. The PoC was able to identify when a device was plugged into an outlet and the location of the device in the building. When a device was moved, the PoC's dashboard and database were automatically updated with the new location. The PoC implemented controls to devices from the system dashboard so that devices maintained correct schedules regardless of where they were plugged in within the building. ATLIS's primary technology application is improved PLM, but other applications include asset management, energy audits, and interoperability for grid-interactive efficient buildings. An ATLIS-based system could also be used to direct power to critical devices, such as ventilators, during a brownout or blackout. Such a framework is an opportunity to make PLM more widespread and reduce the amount of energy consumed by PPLs in current and future commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot-Scale Continuous Plug-Flow Hydrothermal Liquefaction of Food Waste for Biocrude Production

Pilot-scale hydrothermal liquefaction (HTL) of biowaste is a critical step toward commercialization of the HTL technology. Despite many HTL studies conducted with wet biomass, including food waste, few were performed with a pilot-scale continuous plug-flow reactor (PFR), with the biocrude yield and quality analysis based on dewatering (ASTM D2892 Annex X1). This paper describes the development and performance evaluation of a mobile pilot-scale HTL continuous PFR, with a processing capacity of 60 L/h of wet feedstock and 6 L/h of biocrude production. The reactor system was designed for reaction conditions of up to 325 °C and 17.25 MPa. The reactor has a volume of 28.88 L with an additional counterflow heat exchanger volume of 18.07 L. Two types of food wastes, from a food processing plant and grocery store, were processed at 280 °C for 30 min, producing biocrude oil yields of 52.19 and 47.06 wt %, energy recoveries of 68.17 and 70.77%, and carbon recoveries of 66.91 and 64.78%, respectively. Furthermore, due to its high feedstock capacity and reaction volume, large amounts of biocrude oil and post-HTL wastewater (PHW) were obtained from this pilot-scale reactor to allow downstream research on upgrading biocrude oil for transportation fuel as well as PHW treatment and nutrient recovery.

09 BIOMASS FUELS↗

ZIPPER: Zonal isolation with plug and perf in enhanced reservoirs (Final Technical Report)

Modern multistage hydraulic stimulation treatments in cased wellbores require an effective method of isolating stages between treatments. A commonly used method in the oil and gas industry, plug and perf, is not currently viable for Enhanced Geothermal Systems (EGS) due to limitations of a critical component of the system – the ball drop (flow through) frac plug. Commercially available ball drop frac plugs do not meet the temperature or wellbore diameter requirements needed for use in EGS stimulations. For example, one particular drillable bridge and frac plug line from a large tool developer is only rated to 175 °C, while another is only available up to casing sizes of 5 ½” and rated up to 204 °C. We developed, prototyped, and field tested an upgraded ball drop frac plug to meet the requirements of EGS stimulations, including high-temperature (225+ °C), differential pressure (6000+ psi), and wellbore diameters ranging from 6 5/8” to 10 5/8”. We focused on designs and materials to optimize drillability, a key cost driver in plug and perf systems. The primary objective was to upgrade a drillable frac plug (currently rated to a temperature of 175°C and a pressure of 10,000 psi in 7” casing) to withstand temperatures of 225+°C. The upgraded frac plug was tested in the laboratory as well as in a field trial at a geothermal field. Engineering design and fabrication of the new plug was completed in 2019. Lab testing, validation, and qualification of the plug was completed in 2020. Ultimately the plug was successfully run during a multistage stimulation treatment in a fully horizontal EGS well in 2022. Prior to this project, a ball-drop, flow-through stimulation plug had never been used in a geothermal well. At the conclusion of this project, three different types of zonal isolation plugs were evaluated under full-scale operating conditions across 16 stimulation treatment stages in a first-of-a-kind EGS project called Project Red. This trial included the newly designed high-temperature, large-diameter plug. The plugs met all of 5 the technical requirements for commercial viability. Project Red has since been fully commissioned and is generating electricity on the Nevada grid - the first EGS project to successfully deliver power to the grid in the US.

15 GEOTHERMAL ENERGY↗

Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

The Assistant Secretary of the Army (Installations, Energy and Environment) tasked the Pacific Northwest National Laboratory to examine plug loads in typical Army buildings. Plug loads (also known as miscellaneous electric loads (MELs)) represent the electricity used by appliances and devices that are plugged in or hardwired and serve functions outside of a building’s core end uses. Common plug loads include computers, printers, copiers, networking devices, refrigerators, and vending machines. They also include personal electronic devices such as televisions, smart phones, tablets, and gaming systems. Examples of hardwired MELs include elevators, air compressors, and fire and security systems. The findings from this study confirm that significant energy is consumed within Army buildings by plug load devices and hardwired MEL equipment. A number of opportunities are identified for reducing unnecessary energy use that could save the Army over $5 million per year when broadly applied. Army regulations clearly spell out expectations for the purchase and operation of information technology equipment (computers, laptops, monitors, printers, and multi-function devices). However, the policies regarding the shutdown or activation of sleep and other lower power modes after 30 minutes of inactivity (15 minutes for monitors) do not appear to be consistently followed. There are many effective approaches and pathways for impacting change as it relates to improving awareness, implementing measures, and adjusting behaviors to identify and reduce plug load energy use. The Army should prioritize and consider deploying all of these to better understand and manage plug load equipment to save energy and enhance resilience across their facilities. Engaging the building occupants who use these devices daily via outreach and education should be a strong component of the strategy. The focus should be on reducing waste without sacrificing productivity or the benefits that many of these devices provide. Continued evaluation of plug loads beyond that performed here is important to gather lessons from additional building and equipment types, and to stay aware of evolving device technology and management options. This will highlight additional needs for policies, best practices, control technologies, and education of personnel to achieve real reductions in energy waste from plug load equipment. It is recommended that this study may serve as the foundation for a broader and sustained focus on plug loads and MELs, towards simultaneously enhancing the productivity, readiness, and resilience of the Army while reducing energy use and demand, and freeing up resources to better support the mission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resonant acoustic monitoring of damage in plug‐screw feeders

Abstract Plug‐screw feeders are critical in many industrial processes for compressing slurry materials via a rotating plug‐screw feeder. Over time, increasing plug‐screw feeder wear will eventually lead to catastrophic mechanical failure. Early detection of the wear state can prevent unplanned catastrophic failures resulting in operational shut‐downs, costly repairs, and most importantly the health and safety of workers. We present a theoretical basis for a noninvasive, in operando acoustic resonant technique to monitor the wear state of plug‐screw feeders. The technique is based on tracking the resonant acoustic modes of the plug‐screw feeder, which are sensitive to the plug‐screw feeder geometry, material, and operating conditions. We implemented a multivariate polynomial model to estimate the plug‐screw feeder wear state using multiple acoustic resonances by simulating the acoustic resonant modes for two categories of wear (tip and thread damage) that are common in plug‐screw feeders. Fitting multiple resonances to the polynomial model, we demonstrate accurate estimation of the total mass loss, as well as characterization of the type of damage (i.e., tip vs. thread). Current approaches for monitoring plug‐screw feeder wear rely on shutting down the operation and visually inspecting the plug‐screw feeder. The presented acoustic technique offers a noninvasive, in operando measurement approach that mitigates unplanned catastrophic failures. The acoustic resonance technique presented in the paper has a broad range of industrial applications including the Pharmaceutical, Mining, Integrated Biorefineries (IBR), and Additive Manufacturing industries, to name a few.

36 MATERIALS SCIENCE↗

Emerging Technologies for Improved Plug Load Management Systems: Learning Behavior Algorithms and Automatic and Dynamic Load Detection

Plug loads are responsible for a significant portion of the energy consumed in commercial buildings, yet their distributed and ever-changing nature makes them one of the most challenging building end uses to manage. Plug load management systems exist today that utilize smart plugs to meter and control devices at the outlet level, however, their uptake has been relatively slow in part due to the significant labor required for installation and maintenance. Learning behavior algorithms and automatic and dynamic load detection have been identified as two technology areas that could accelerate the adoption of plug load management systems by reducing these labor demands and providing additional energy efficiency and non-energy benefits. Learning behavior algorithms learn occupant behavior and adjust plug load management systems accordingly, allowing for the automatic creation of optimized control schedules. Automatic and dynamic load detection allows a plug load management system to identify devices as they are plugged in to a building and keeps the system up to date as devices are moved throughout a building. In this paper, we present our findings with respect to the current state of these two technologies based on a review of existing research and patents, as well as a series of interviews with companies working in the plug load space. We have found that, as of now, no commercialized solutions exist for these plug load technologies and that more work is needed to bring them to market. In addition, we summarize our findings related to the technology challenges, market barriers, drivers, and opportunities for these technologies moving forward.

30 DIRECT ENERGY CONVERSION↗

Large-scale inflatable structures for tunnel protection: a review of the Resilient Tunnel Plug project

The protection of underground civil infrastructure continues to be a high priority for transportation and transit security agencies. In particular, rail transit tunnels running under bodies of water are susceptible to disruptions due to flooding caused by extraordinary climatic events such as hurricanes or other events resulting from human activities. Several events have taken place in the past decades that have demonstrated the need to mitigate vulnerabilities or, at least, minimize the consequences of catastrophic events. Although it is impossible to prevent all situations that can lead to flooding, damage can be substantially decreased by reducing the area affected by the event. To minimize the effects of an event, a possible approach is to compartmentalize the tunnel system by creating temporary barriers that can contain the propagation of flooding until a more permanent solution can be implemented. One way to create a temporary barrier is by the deployment of a large-scale inflatable structure, also known as an inflatable plug. In such an application, the inflatable structure is prepared for placement, either permanently or temporally, and maintained ready for deployment, inflation, and pressurization when needed. The internal plug pressure imparts a normal force against the tunnel wall surface with the friction between the plug and tunnel surfaces opposing axial movement of the plug. The sealing effectiveness depends on the ability of the inflatable structure to self-deploy and fit, without human intervention, to the intricacies of the perimeter of the conduit being sealed. Primary design constraints include having the plug stowed away from the dynamic envelope of the trains and being able to withhold the pressure of the flooding water. This work presents a compilation of the main aspects of the activities completed for the development of large-scale inflatable structures as part of the Resilient Tunnel Plug (RTP) Project. The main test results and lessons learned are presented to demonstrate the viability of implementing large-scale inflatable plugs for the containment of flooding in rail tunnels systems. Over 400 coupon and specimen tests, 200 reduced scale tests, and 100 full-scale tests were conducted to demonstrate the efficacy of the design of different prototypes over a 10-year research and development project. The culmination of the work was 12 large-scale flooding demonstrations where the inflatable tunnel plug was shown able to be deployed remotely and withstand a simulated flooding event.

42 ENGINEERING↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Dip leg plug formation evaluation and abatement testing in support of the H-Canyon accelerated basin de-inventory

As requested in the Technical Task Request (TTR), the Savannah River National Laboratory (SRNL) performed testing on the current typical bubbler dip leg design used in the H-Area Canyon (HCA). The TTR has a functional classification of General Services. Testing was initiated to ascertain if the plugging described in the TTR could be reproduced and, if so, to obtain general metrics on the resulting plugging dynamics, and evaluate possible mitigating methods, including design changes and cleaning/purging protocols. The bubblers were to be suspended in a simulant typical of H-Canyon solutions containing aluminum nitrate and silica at a temperature of 25°C using a nominal bubbler air flowrate of 7.5 SCFH. Emphasis was placed on minimizing equipment changes necessary to accomplish the mitigations, as equipment changes in the existing facility would be costly. Testing evolved into four (4) phases, concluding that plugging could indeed be reproduced (believed to be attributed to localized evaporation and bridging of crystals in the dip legs). During testing, plug formation information was obtained, including time, pressure, and temperature traces leading to plugging were defined; solution compositions leading to plugging were determined, and various physical characteristics (visual and mechanical) of the crystallized plug were obtained.

42 ENGINEERING↗

Screening and qualification methodology for SiC end plug processing methods

Deployment of SiC-ceramic-based fuel cladding for light water reactors requires a hermetic end plug–to–cladding joint that can withstand neutron irradiation during normal operation and maintain integrity during design-basis accidents. Reactor experiments have shown that some SiC composite tubes with SiC end plugs can retain hermeticity after irradiation. However, achieving consistent joint performance under irradiation remains a key challenge. Resolving this issue is essential to enable integral irradiation testing and to demonstrate fuel integrity under commercial-reactor irradiation conditions. This report aims to: (1) provide guidance for designing radiation-tolerant end plug joints for SiC cladding; (2) demonstrate experimental methods to detect processing defects that are unstable under neutron irradiation at light-water-reactor-relevant temperatures and doses; and (3) outline a step-by-step approach for designing and conducting reactor experiments to screen joining methods. The resulting data will be used to improve joint processing and to define critical defect types and sizes that must be detected and eliminated through non-destructive evaluation for quality assurance. Based on prior irradiation experiments at the High Flux Isotope Reactor, differential swelling among the cladding, bonding layer, and end plug was identified as an underlying mechanism for irradiation-induced joint degradation. Accordingly, this effect must be considered in the design of radiation-tolerant joining techniques. In this work, miniature SiC end plug joint specimens irradiated during the previous project were analyzed using X-ray computed tomography to characterize the joint microstructure. Digital volume correlation of the tomography data quantified radiation-induced microstructural changes and enabled evaluation of defect-related risks. Finally, ongoing neutron irradiation efforts using larger specimen volumes are presented. These efforts aim to statistically assess joint performance and to build a microstructure–performance (e.g., leak-tightness) dataset to inform processing improvements and quality control.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Barriers to Balcony Solar and Plug-In Distributed Energy Resources in the United States

Plug-in distributed energy resources (DERs), such as balcony solar, backfeed power to the home through a standard plug. These systems may represent the future of residential solar and storage, particularly as recent net metering policies have reduced the economic appeal of rooftop solar. While plug-in DERs have seen widespread success in Europe, their U.S. market is stagnant. This paper reviews the technical, interconnection, and regulatory barriers hindering the adoption of plug-in DERs. We first discuss the technical barriers, which include touch safety, breaker masking, and bidirectional ground-fault circuit interrupters. We then examine utility perspectives on plug-in DERs and strategies for navigating interconnection challenges. Finally, we discuss regulatory hurdles related to UL standards and the National Electrical Code.

Gerber, Daniel L. (ORCID:0000000219720679)↗

Utah FORGE: Optimization of a Plug-and-Perf Stimulation (Fervo Energy)

Information around the plug-and-perf treatment design at Utah FORGE by Fervo Energy. Objective and Purpose: - Develop a multistage hydraulic stimulation approach designed specifically to target the top three factors that control the technical and commercial viability of an EGS system: i) Achieving sufficient injectivity to support high cross-well flow rates ii) Distributing flow evenly across the wellbore and reservoir to maximize heat mining efficiency, ensure sustained heat transfer, and mitigate thermal breakthrough iii) Overcoming the effects of stress heterogeneity, stress shadowing, and variations in natural fracture properties during the stimulation treatment, leading to a more predictable stimulated reservoir volume and offset well placement - The following activities will be performed: i) Design, plan, and execute a multistage plug-and-perf stimulation treatment at a Fervo site with data acquisition and well testing activities aimed at addressing key technical aspects of the issues above ii) Perform data processing and interpretation of field results to translate the results form the Fervo site to a site-specific design at the Utah FORGE site iii) Design, plan, and execute a multistage plug-and-perf stimulation treatment design at the Utah FORGE site Methods and Approach: - Design a detailed data acquisition plan to maximize learning around: i) DFIT testing ii) Petrophysical logging, image logging iii) Permanent DAS/DTS fiber optic monitoring iv) Deep borehole microseismic monitoring v) Shallow borehole induced seismicity monitoring vi) Injection/production testing (RTA analysis, tracer testing) vii) Integrated numerical modeling and production forecasting

15 GEOTHERMAL ENERGY↗

Emerging Plug Load Management Technologies that Save Energy and Time

This fact sheet introduces two emerging technologies that could streamline plug load management (PLM) for increased energy savings for building owners: learning behavior algorithms (LBA) and automatic and dynamic load detection (ADLD). Plug loads are responsible for 47% of the energy consumed in commercial buildings, yet their distributed and ever-changing nature makes them challenging to manage. PLM systems exist today that use smart plugs to meter and control devices at the outlet level, but their uptake has been relatively slow in part because of the significant labor required for installation and maintenance. LBA and ADLD may address these challenges and provide additional energy efficiency and nonenergy benefits.

Plug and process loads, PPL, plug loads, plug load↗

SAM Plug-in Development (Phase I Final Report)

The DOE Office of Nuclear Energy (NE) has created an extensive set of advanced modeling and simulation tools for nuclear engineering analysis. The advanced capabilities of these newer analysis codes require more in-depth training, skills, and knowledge in order to effectively utilize them for the design, analysis, and licensing of advanced nuclear systems and experiments. A high learning curve for inexperienced users may deter organizations from incorporating these tools into their internal processes. This project involved development of a plug-in to the Symbolic Nuclear Analysis Package (SNAP) for the System Analysis Module (SAM) tool. SAM is an advanced system analysis tool for reactor transient analyses being developed at Argonne National Laboratory under the U.S. DOE Office of Nuclear Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. SAM utilizes an object-oriented application framework (MOOSE), and its underlying meshing and finite-element library (libMesh) and linear and non-linear solvers (PETSc), to leverage modern advanced software environments and numerical methods. SNAP provides a highly flexible framework for creating, modifying and documenting input for engineering analysis codes such as SAM as well as extensive functionality for submitting, monitoring, and interacting with the codes through an intuitive graphical user interface (GUI). The common user interface provided by SNAP minimizes the learning curve for engineers starting with a new analysis code and provides an intuitive framework for transitioning between different analysis codes. SNAP provides a powerful but intuitive interface to facilitate access to advanced modeling and simulation tools for inexperienced users. Unlike many “form based” GUI’s, SNAP maps each engineering code’s component input to an internal database which manages all component input parameters along with component interconnections. This level of abstraction permits SNAP to support several advanced capabilities such as renodalization, model validation and consistency checks, embedded documentation, model notebook generation, data ownership and reviewer tracking, and variable assignment for inputs to name a few. SNAP includes a built-in Python interpreter and is interfaced to several commercial and open source packages including CPython, MATLAB/OCTAVE, Microsoft Office, Open Office, and SANDIA’s DAKOTA package which provides Uncertainty Quantification analysis through the SNAP plug-ins. Phase I of this project involved development a fully functional basic SAM plug-in to SNAP. This plug-in provides the ability to import existing models, graphically construct, edit and submit models using SNAP’s extensive functionality.

99 GENERAL AND MISCELLANEOUS↗

Wall plug efficiency analysis of a compact SRF industrial accelerator [Poster]

Superconducting radiofrequency cavities offer extremely high (>90%) RF-to-beam energy conversion efficiency. Recent breakthroughs in the Nb 3 Sn SRF cavity technology, successful demonstration of the conduction cooling technique, and the availability of high cooling capacity cryocoolers has made possible the use of SRF for industrial particle accelerators. However, the overall wall plug-to-beam efficiency of such an SRF accelerator can be limited by the wall plug-to-RF power efficiency of the RF source powering this accelerator. The present study quantifies the wall plug-to-beam efficiency of a conduction-cooled SRF accelerator considering several different choices of the RF power source. The study concludes that the wall plug efficiency of the accelerator is indeed limited by that of the power source.

43 PARTICLE ACCELERATORS↗

Wall plug efficiency analysis of a compact SRF industrial accelerator [Poster]

Superconducting radiofrequency cavities offer extremely high (>90%) RF-to-beam energy conversion efficiency. Recent breakthroughs in the Nb 3 Sn SRF cavity technology, successful demonstration of the conduction cooling technique, and the availability of high cooling capacity cryocoolers has made possible the use of SRF for industrial particle accelerators. However, the overall wall plug-to-beam efficiency of such an SRF accelerator can be limited by the wall plug-to-RF power efficiency of the RF source powering this accelerator. The present study quantifies the wall plug-to-beam efficiency of a conduction-cooled SRF accelerator considering several different choices of the RF power source. The study concludes that the wall plug efficiency of the accelerator is indeed limited by that of the power source.

43 PARTICLE ACCELERATORS↗

High-Temperature SiC Cladding End Plug Irradiation Design and HFIR Readiness

This report documents the design of a High Flux Isotope Reactor (HFIR) irradiation experiment intended to evaluate irradiation effects on the hermeticity of silicon carbide (SiC) end plug specimens under a radial fast neutron flux gradient at representative light-water reactor (LWR) temperatures of approximately 300 °C. The overarching goal of this work is to statistically evaluate SiC end plug hermeticity and mechanical properties following irradiation using the high-throughput irradiation capability discussed here. Each specimen consists of a short section of SiC fiber–reinforced SiC (SiC/SiC) tube with a single monolithic SiC end plug joined to one end. The experiment allows up to 66 specimens to be irradiated in six different stacks within a dry, sealed irradiation capsule derived from the previously developed high-temperature SiC/SiC cladding bowing experiment. The neutronics basis, thermal analysis, and HFIR readiness of the experiment are discussed in this report for two possible design cases. The first design case is based on existing approval documentation and components that are on hand and approved for use, so the experiment insertion would require only specimen receipt, specimen pre-irradiation characterization, experiment assembly, and final fabrication package approval. The second design case provides improved thermal robustness and the preferred end plug geometry but requires fabrication of a modified holder and revisions to the HFIR approval documentation, in addition to the other activities required for the first design case, before insertion.

Hott, Daniel [Oak Ridge National Laboratory (ORNL)↗