Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Plenoptic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Plenoptic Imager for Automated Surface Navigation

An electro-optical imaging device is capable of autonomously determining the range to objects in a scene without the use of active emitters or multiple apertures. The novel, automated, low-power imaging system is based on a plenoptic camera design that was constructed as a breadboard system. Nanohmics proved feasibility of the concept by designing an optical system for a prototype plenoptic camera, developing simulated plenoptic images and range-calculation algorithms, constructing a breadboard prototype plenoptic camera, and processing images (including range calculations) from the prototype system. The breadboard demonstration included an optical subsystem comprised of a main aperture lens, a mechanical structure that holds an array of micro lenses at the focal distance from the main lens, and a structure that mates a CMOS imaging sensor the correct distance from the micro lenses. The demonstrator also featured embedded electronics for camera readout, and a post-processor executing image-processing algorithms to provide ranging information.

Zollar, Byron

Simultaneous Conventional and Plenoptic Background Oriented Schlieren Imaging

Plenoptic Background Oriented Schlieren (BOS) is an emerging schlieren technique that is capable of providing 3D qualitative and quantitative information about density gradients present in a wide range of fluid dynamics problems. In this work, the fundamental concepts of plenoptic BOS are reviewed before discussing an open-air experiment with a buoyant plume where both conventional BOS and plenoptic BOS measurements were acquired simultaneously. Both cameras had the same field-of-view for all experiments, and three different focal plane arrangements were explored: (1) the focal plane was set to the background positions and the plume varied between 11 different positions relative to this focal plane, (2) the focal plane was set to 635- millimeters in front of the background position, and (3) the nominal focal plane varied while the position of the plume remained fixed. Such discussion will provide insight on how the two techniques compare, and what additional work is required to better understand the results provided by these two imaging systems.

Klemkowsky, Jenna N.

NASA Tech Briefs, September 2010

Topics covered include: Instrument for Measuring Thermal Conductivity of Materials at Low Temperatures; Multi-Axis Accelerometer Calibration System; Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems; Autonomous System for Monitoring the Integrity of Composite Fan Housings; A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation; Adaptation of the Camera Link Interface for Flight-Instrument Applications; High-Performance CCSDS Encapsulation Service Implementation in FPGA; High-Performance CCSDS AOS Protocol Implementation in FPGA; Advanced Flip Chips in Extreme Temperature Environments; Diffuse-Illumination Systems for Growing Plants; Microwave Plasma Hydrogen Recovery System; Producing Hydrogen by Plasma Pyrolysis of Methane; Self-Deployable Membrane Structures; Reactivation of a Tin-Oxide-Containing Catalys; Functionalization of Single-Wall Carbon Nanotubes by Photo-Oxidation; Miniature Piezoelectric Macro-Mass Balance; Acoustic Liner for Turbomachinery Applications; Metering Gas Strut for Separating Rocket Stages; Large-Flow-Area Flow-Selective Liquid/Gas Separator; Counterflowing Jet Subsystem Design; Water Tank with Capillary Air/Liquid Separation; True Shear Parallel Plate Viscometer; Focusing Diffraction Grating Element with Aberration Control; Universal Millimeter-Wave Radar Front End; Mode Selection for a Single-Frequency Fiber Laser; Qualification and Selection of Flight Diode Lasers for Space Applications; Plenoptic Imager for Automated Surface Navigation; Maglev Facility for Simulating Variable Gravity; Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection; High-Speed Operation of Interband Cascade Lasers; 3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events; Charge-Spot Model for Electrostatic Forces in Simulation of Fine Particulates; Hidden Statistics Approach to Quantum Simulations; Reconstituted Three-Dimensional Interactive Imaging; Determining Atmospheric-Density Profile of Titan; Digital Microfluidics Sample Analyzer; Radiation Protection Using Carbon Nanotube Derivatives; Process to Selectively Distinguish Viable from Non-Viable Bacterial Cells; and TEAMS Model Analyzer.

Source record

TPSAS-NF1676L-33668-DND

A three-color pyrometer has been developed based on plenoptic imaging technology. Three bandpass filters placed in front of the camera lens allows separate 2D images to be obtained at three different wavelengths. Images were obtained of different black- or grey-bodies including a calibration furnace, a radiation heater, a sooting butane flame and a luminous sulfur match flame. The images were processed to determine 2D temperature distributions. Calibration results in the furnace showed that the instrument could measure temperature with an accuracy and precision of 10 Kelvins between 1100 and 1350 K. Time-resolved 2D measurements of the radiation heater, flame and match are shown.

Paul M Danehy

A Plenoptic Multi-Color Imaging Pyrometer

A three-color pyrometer has been developed based on plenoptic imaging technology. Three bandpass filters placed in front of a camera lens allow separate 2D images to be obtained on a single image sensor at three different and adjustable wavelengths selected by the user. Images were obtained of different black- or grey-bodies including a calibration furnace, a radiation heater, and a luminous sulfur match flame. The images obtained of the calibration furnace and radiation heater were processed to determine 2D temperature distributions. Calibration results in the furnace showed that the instrument can measure temperature with an accuracy and precision of 10 Kelvins between 1100 and 1350 K. Time-resolved 2D temperature measurements of the radiation heater are shown.

Danehy, Paul M.

Design of a Multi-Color Plenoptic Camera for Snapshot Hyperspectral Imaging

The design of a custom camera lens including: a two-lens optical system, filter array, and iris has been developed enabling a greyscale plenoptic camera to acquire full field-of-view, 2D, instantaneous hyperspectral measurements. This work focuses on the use of 7 discrete color filters and their effect on the image quality. It was determined that the placement of the filters inside the aperture plane of the camera was paramount to mitigating image artifacts. In addition, design rules were developed such that the optimal optical parameters (image distance, working distance, and focal length) can be easily determined from a few charts.

Fahringer, Timothy W., Jr.

Recent Progress and Development of Self-Aligned Focusing Schlieren

A broad range of developments and applications of self-aligned focusing schlieren (SAFS)systems is presented. The replacement of the Ronchi ruling (RR) with a𝜇LCD was demonstrated with digital SAFS, which provides the ability to modulate the pattern and orientation without physical intervention. Additionally, replacement of the traditional RR with spectral-spatial filters was demonstrated to yield the ability to simultaneously image horizontal and vertical index of refraction gradients using two separate wavelengths. The application of the Scheimpflug principle to SAFS systems enables off-axis imaging and allowed for extended fields-of-view to be captured using a two-camera system. The addition of a plenoptic camera to a baseline SAFS system enables refocusing capabilities, which is demonstrated on two jets offset along the optical axis. Furthermore, application of an event-based camera to SAFS was shown to enable acquisition of sparse, spatio-temporal data. Beyond the listed developments, SAFS was applied to difficult and constraining facilities, such as the National Full-Scale Aerodynamics Complex(NFAC) 80- by 120-ft Wind Tunnel and the Thermal Acoustic Engines (TAE) rig at NASA Ames Research Center and NASA Glenn Research Center, respectively. Behavior of Ronchi rulings, Rochon prisms, and the use of quarter-wave plates versus quarter-wave films are evaluated to provide insight for future experimental design of SAFS-systems.

Self-Aligned Focusing Schlieren

Recent Progress and Development of Self-Aligned Focusing Schlieren

A broad range of developments and applications of self-aligned focusing schlieren (SAFS)systems is presented. The replacement of the Ronchi ruling (RR) with a𝜇LCD was demonstrated with digital SAFS, which provides the ability to modulate the pattern and orientation without physical intervention. Additionally, replacement of the traditional RR with spectral-spatial filters was demonstrated to yield the ability to simultaneously image horizontal and vertical index of refraction gradients using two separate wavelengths. The application of the Scheimpflug principle to SAFS systems enables off-axis imaging and allowed for extended fields-of-view to be captured using a two-camera system. The addition of a plenoptic camera to a baseline SAFS system enables refocusing capabilities, which is demonstrated on two jets offset along the optical axis. Furthermore, application of an event-based camera to SAFS was shown to enable acquisition of sparse, spatio-temporal data. Beyond the listed developments, SAFS was applied to difficult and constraining facilities, such as the National Full-Scale Aerodynamics Complex(NFAC) 80- by 120-ft Wind Tunnel and the Thermal Acoustic Engines (TAE) rig at NASA Ames Research Center and NASA Glenn Research Center, respectively. Behavior of Ronchi rulings, Rochon prisms, and the use of quarter-wave plates versus quarter-wave films are evaluated to provide insight for future experimental design of SAFS-systems.

Self-Aligned Focusing Schlieren