Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Plastic scintillators,”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Epoxy resins produce improved plastic scintillators

Plastic scintillator produced by the substitution of epoxy resins for the commonly used polystyrene is easy to cast, stable at room temperature, and has the desirable properties of a thermoset or cross-linked system. Such scintillators can be immersed directly in strong solvents, an advantage in many chemical and biological experiments.

Markley, F. W.

Transition effect of air shower particles in plastic scintillators

The transition effect of air shower particles in the plastic scintillators near the core was measured by scintillators of various thickness. The air showers selected for the measurement were of 10,000. Results obtained are as follows: (1) the multiplication of shower particles in the scintillators is less than 20% for that of 50 mm thickness; (2) dependence of the transition effect on age parameter is not recognized within the experimental errors.

Asakimori, K.

Plastic scintillation counters with an area of 2 sq m

Two designs of plastic scintillation counters with an area of 2 sq m scanned in each case by a single photomultiplier of the FEU-49 type are described. The radial dependence of their light collection at the place of the path of the detected particle does not exceed 10% while the half width of the differential distribution of the pulse amplitudes from nonfiltered cosmic radiation at sea level is 90 to 95%, and 65%, the plastic thickness being 5 cm and 10 cm, respectively. The temperature coefficient of the counter is 0.32% per 1 C.

Yegorov, T. A.

Plastic scintillator block as photon beam monitor for EGRET calibration

The EGRET (Energetic Gamma Ray Experiment Telescope) detector has been calibrated at SLAC (Stanford Linear Accelerator) and, to a lesser degree, at the MIT Bates Linear Accelerator Center. To monitor the photon beams for the calibration, a plastic scintillator block, 5 cm x 5 cm in cross section, 15 cm in length, and viewed by a single photomultiplier tube, was used for the entire beam energy range of 15 MeV to 10 GeV. The design operation, and method of analysis of the beam intensity are presented. A mathematical framework has been developed to treat the general case of a beam with multiphoton beam pulses and with a background component. A procedure to deal with the fluctuations of the beam intensity over a data-taking period was also developed. The photon beam monitor is physically sturdy, electronically steady, simple to construct, and easy to operate. Its major merits lie in its sheer simplicity of construction and operation and in the wide energy range it can cover.

Lin, Y. C.

Plastic scintillators in coincidence for the study of multi-particle production of sea level cosmic rays in dense medium

Cosmic ray particles at sea level penetrate a thick layer of dense medium without appreciable interaction. These penetrating particles are identified with muons. The only appreciable interaction of muons are by knock on processes. A muon may have single, double or any number of knock on with atoms of the material so that one, two, three or more particles will come out from the medium in which the knock on processes occur. The probability of multiparticle production is expected to decrease with the increase of multiplicity. Measurements of the single, double, and triple particles generated in a dense medium (Fe and Al) by sea level cosmic rays at 22.42 N. Lat. and 114.20 E. Long. (Hong Kong) are presented using a detector composed of two plastic scintillators connected in coincidence.

Chuang, L. S.

Scintillating plastic fibers as light pipes for a cosmic ray hodoscope: Feasibility calculations and measured attenuation characteristics

A candidate hodoscope uses arrays of scintillator fibers, followed by an image intensifier and imaging system such as that proposed for the X-ray shadowgraph. A literature search was performed to ascertain the experience of other workers with hodoscopes using this or similar principles. Calculations were performed to determine the feasibility of candidate systems and some laboratory experiments were performed to attempt to check these numbers.

Source record

High Efficiency Plastic Scintillator Detector with Wave-Length Shifting Fiber Readout for the GLAST Large Area Telescope

This paper describes the design and performance studies of the scintillator tile detectors for the Anti-Coincidence Detector (ACD) of the Large Area Telescope (LAT) on the Gamma ray Large Area Space Telescope (GLAST), scheduled for launch in early 2008. The scintillator tile detectors utilize wavelength shifting fibers and have dual photomultiplier tube (PMT) readout. The design requires highly efficient and uniform detection of singly charged relativistic particles over the tile area and must meet all requirements for a launch, as well as operation in a space environment. We present here the design of three basic types of tiles used in the ACD, ranging in size from approx.450 sq cm to approx.2500 sq cm, all 1 cm thick, with different shapes, and with photoelectron yield of approx. 20 photoelectrons per minimum ionizing particle (mip) at normal tile incidence, uniform over the tile area. Some tiles require flexible clear fiber cables up to 1.5 m long to deliver scintillator light to remotely located PMT.

Moiseev, A. A.

EGRET - The high energy gamma ray telescope for NASA's Gamma Ray Observatory

The EGRET high energy gamma-ray telescope under development for NASA's Gamma Ray Observatory will have an energy range of approximately 12 to 30,000 MeV, energy resolution of about 15 percent FWHM over most of that range, an effective area of about 2000 sq cm at high energies, and single photon angular accuracy of approximately 2 deg at 100 MeV, less than 0.1 deg above 5 GeV. This instrument can locate strong sources to an accuracy of about 5 arc min. The instrument utilizes a set of digital spark chambers interleaved with tantalum foils for detection and identification of gamma-ray events, and a large NaI(Tl) scintillator for energy determination. The system is triggered by a coincidence matrix using two arrays of plastic scintillation counters and a large plastic scintillator anticoincidence dome that rejects incident charged particles.

Fichtel, C. E.

The UCSD high energy X-ray timing experiment cosmic ray particle anticoincidence detector

The HEXTE, part of the X-Ray Timing Explorer (XTE), is designed to make high sensitivity temporal and spectral measurements of X-rays with energies between 15 and 250 keV using NaI/CsI phoswich scintillation counters. To achieve the required sensitivity it is necessary to provide anticoincidence of charged cosmic ray particles incident upon the instrument, some of which interact to produce background X-rays. The proposed cosmic ray particle anticoincidence shield detector for HEXTE uses a novel design based on plastic scintillators and wavelength-shifter bars. It consists of five segments, each with a 7 mm thick plastic scintillator, roughly 50 cm x 50 cm in size, coupled to two wavelength-shifter bars viewed by 1/2 inch photomultiplier tubes. These segments are configured into a five-sided, box-like structure around the main detector system. Results of laboratory testing of a model segment, and calculations of the expected performance of the flight segments and particle anticoincidence detector system are presented to demonstrate that the above anticoincidence detector system satisfies its scientific requirements.

Hink, P. L.

Electron showers of high primary energy in lead.

The development of electron cascade showers in a lead-scintillator sandwich of 8 plastic scintillators in about 20 radiation lengths of lead has been investigated. This detector, which was used for cosmic-ray studies, has been calibrated with electrons with energies from 2 to 15 GeV at SLAC. Measured shower profiles are presented, and expressions are given which allow an extrapolation of the measured data up to energies around 1000 GeV. The results are compared with analytical shower theories and Monte Carlo calculations.

Mueller, D.

A balloon measurement of the cosmic ray element abundances

The experiment described was flown from Thompson, Canada in August, 1973 to measure the cosmic ray element abundances in the atmosphere. All particles used in the analysis, including approximately 25,000 oxygen and 1600 iron nuclei, had sufficient energy at the top of the atmosphere to trigger the Cerenkov counter. Nuclei between beryllium and nickel were identified, using two plastic scintillators and an acrylic plastic Cerenkov counter. The relative composition and fluxes are determined. Agreement with earlier measurements in the atmosphere is within 5%; however, larger differences appear in composition extrapolated to the top of the atmosphere. In particular, the nitrogen abundance is almost 20% higher and the iron abundance is 20% lower than the generally accepted values.

Ormes, J. F.

Cosmic-ray cascades photographed in scintillator

Light produced by nuclear-electromagnetic cascades in a plastic scintillator can be photographed, and the resulting images on film used to measure both the energy content of the cascades and also the positions at which the cascades passed through the scintillator. The energy content of a cascade can be measured to 20% and its position determined to plus or minus 0.8 cm in each scintillator. Techniques for photographing the cascades and analyzing the film are described. Sample data are presented and discussed.

Barrowes, S. C.