Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plasma spectroscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Atomic data for beam-stimulated plasma spectroscopy in fusion plasmas

Injection of high energy atoms into a confined plasma volume is an established diagnostic technique in fusion research. This method strongly depends on the quality of atomic data for charge-exchange recombination spectroscopy (CXRS), motional Stark effect (MSE) and beam-emission spectroscopy (BES). We present some examples of atomic data for CXRS and review the current status of collisional data for parabolic states of hydrogen atoms that are used for accurate MSE modeling. It is shown that the collisional data require knowledge of the excitation density matrix including the off-diagonal matrix elements. The new datasets for transitions between parabolic states are used in an extended collisional-radiative model. The ratios between the {sigma}- and {pi}-components and the beam-emission rate coefficients are calculated in a quasi-steady state approximation. Good agreement with the experimental data from JET is found which points out to strong deviations from the statistical distribution for magnetic sublevels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Spectroscopy in ISTTOK

Plasma spectroscopy is a well established technique for impurities study in fusion plasmas. A brief description of the several spectroscopic systems which have been in operation at ISTTOK is given. In ISTTOK a passive spectroscopy diagnostic system is being used to perform spectral and spatial characterization in the 300-850 nm wavelength range. The system used to perform that work consist essentially of a cooled CCD camera coupled to a half a meter imaging spectrograph with collection optics based on a multi-fiber set to allow for enhanced spatial resolution. Experimental data is shown underlining typical plasma fusion spectral lines and specific ISTTOK characteristics. A web based data access tool is presented that allows the spectral plasma survey in specific wavelength ranges. The information provided by this survey has been used to select suitable transmission filters for a diagnostic, currently under development, to measure Zeff parameter for ISTTOK plasmas. A description of this diagnostic is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Outlook for active plasma spectroscopy with entangled two-photon absorption

Entangled two-photon absorption (ETPA) exhibits a quantum-enhanced two-photon absorption cross-section and a linear scaling with incident power that exceeds classical two-photon absorption (TPA) at low photon flux. Here, we assess the feasibility and applications of ETPA for active plasma spectroscopy. The ETPA-absorbed power for an Ar + species in a helicon plasma scenario is calculated to be as high as 0.6 nW cm −1 along the incident beam path for nondegenerate-entangled photon pairs that are near-resonant with an intermediate level. The ETPA absorption power exceeds classical TPA and Bremsstrahlung emission, a necessary condition for a feasible fluorescence measurement. Applications of ETPA plasma spectroscopy may include trace impurity detection, ground-state excitation, and continuous-wave pumping for high-bandwidth turbulence measurements. Possible benefits of plasma measurements are less harm to optical components with lower incident flux and reduced stray light that can contaminate optical diagnostics.

active plasma spectroscopy↗

An inexpensive technique for the time resolved laser induced plasma spectroscopy

We present an efficient and inexpensive method for calculating the time resolved emission spectrum from the time integrated spectrum by monitoring the time evolution of neutral and singly ionized species in the laser produced plasma. To validate our assertion of extracting time resolved information from the time integrated spectrum, the time evolution data of the Cu II line at 481.29 nm and the molecular bands of AlO in the wavelength region (450–550 nm) have been studied. The plasma parameters were also estimated from the time resolved and time integrated spectra. A comparison of the results clearly reveals that the time resolved information about the plasma parameters can be extracted from the spectra registered with a time integrated spectrograph. Our proposed method will make the laser induced plasma spectroscopy robust and a low cost technique which is attractive for industry and environmental monitoring.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The use of laser-induced shock wave plasma spectroscopy (LISPS) for examining physical characteristics of pharmaceutical products

An experimental study has been performed to examine the physical characteristics of pharmaceutical products, such as tablet, by employing an emission plasma induced by Nd-YAG laser at a low pressure of Helium gas. The hardness of tablet is one of the parameters that examined during the production process for standard quality of pharmaceutical products. In the Laser-Induced Shock Wave Plasma Spectroscopy (LISPS), the shock wave has a significant role in inducing atomic excitation. It was known that, the speed of the shock wavefront depends on the hardness of the sample, and it correlates with the ionization rate of the ablated atoms. The hardness of the tablet is examined using the intensity ratio between the ion of Mg (II) 275.2 nm and the neutral of Mg (I) 285.2 nm emission lines detected from the laser-induced plasma. It was observed that the ratio changes with respect to the change in the tablet hardness, namely the ratio is higher for the hard tablet. Besides the ratio measurements, we also measured the depth profile of a tablet by focusing 60 shots of irradiation of laser light at a fixed position on the surface of the tablet. It was found that the depth profile varies differently with the hardness of the tablet. These experiment results show that the technique of LISPS can be applied to examine the quality of pharmaceutical products.

36 MATERIALS SCIENCE↗

Laser-Plasma Spectroscopy of Hydroxyl with Applications

This article discusses laser-induced laboratory-air plasma measurements and analysis of hydroxyl (OH) ultraviolet spectra. The computations of the OH spectra utilize line strength data that were developed previously and that are now communicated for the first time. The line strengths have been utilized extensively in interpretation of recorded molecular emission spectra and have been well-tested in laser-induced fluorescence applications for the purpose of temperature inferences from recorded data. Moreover, new experiments with Q-switched laser pulses illustrate occurrence of molecular recombination spectra for time delays of the order of several dozen of microseconds after plasma initiation. The OH signals occur due to the natural humidity in laboratory air. Centrifugal stretching of the Franck-Condon factors and r-centroids are included in the process of determining the line strengths that are communicated as a Supplementary File. Laser spectroscopy applications of detailed OH computations include laser-induced plasma and combustion analyses, to name but two applications. This work also includes literature references that address various diagnosis applications.

47 OTHER INSTRUMENTATION↗

Calibrating Curved Crystals Used for Plasma Spectroscopy

The throughput and resolving power of an X-ray spectrometer that uses a curved crystal as the diffraction element is determined primarily by the crystal X-ray reflectivity properties. This poster presents a measurement technique for these crystal parameters using a simple diode source to produce a narrow spectral band. The results from measurements on concave elliptical polyethylene terephthalate (PET) crystals and convex potassium acid phthalate (KAP) crystals show large variations in the key parameters compared to those from the flat crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transversely Excited Atmospheric CO{sub 2} Laser-Induced Plasma Spectroscopy for the Detection of Heavy Metals in Soil

A rapid detection of heavy metals in soil was presented by the metal-assisted gas plasma method using specific characteristics of a pulsed, transversely excited atmospheric (TEA) CO{sub 2} laser. The soil particles were placed in a hole made of acrylic plate. The sample was covered by a to prevent the soil particles from being blown off. The mesh also functioned to initiate a luminous plasma. When a TEA CO{sub 2} laser (1500 mJ, 200 ns) was focused on the soil sample, passing through the metal mesh, some of the laser energy was used to generate the gas plasma on the mesh surface, and the remaining laser energy was employed to ablate the soil particles. The fine, ablated soil particles moved into the gas plasma region to be dissociated and excited. Using this technique, analysis can be made with reduced sample pretreatment, and therefore a rapid analysis can be performed efficiently. The results proved that the signal to noise ratio (S/N) of the emission spectral lines is much better for the case of the present method (mesh method) compared to the case of standard laser-induced breakdown spectroscopy using the pellet method. Rapid detection of heavy metal elements in soil has been successfully carried out. The detection limits of Cu and Hg in soil were estimated to be 3 and 10 mg/kg, respectively. The present method has good potential for rapid and sensitive detection of heavy metals in soil samples.

54 ENVIRONMENTAL SCIENCES↗

New focusing multilayer structures for X-ray plasma spectroscopy

New focusing short-period multilayer structures are developed which opens up wide possibilities for X-ray and VUV spectroscopy. Multilayer structures are deposited on a flat surface of a mica crystal which is then bent to a small-radius cylinder. The use of this structure in a von Hamos spectrometer for X-ray laser plasma diagnostics is demonstrated. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temporally and spatially resolved plasma spectroscopy in pulsed laser deposition of ultra-thin boron nitride films

Physical vapor deposition (PVD) has recently been investigated as a viable, alternative growth technique for two-dimensional materials with multiple benefits over other vapor deposition synthesis methods. The high kinetic energies and chemical reactivities of the condensing species formed from PVD processes can facilitate growth over large areas and at reduced substrate temperatures. In this study, chemistry, kinetic energies, time of flight data, and spatial distributions within a PVD plasma plume ablated from a boron nitride (BN) target by a KrF laser at different pressures of nitrogen gas were investigated. Time resolved spectroscopy and wavelength specific imaging were used to identify and track atomic neutral and ionized species including B{sup +}, B*, N{sup +}, N*, and molecular species including N{sub 2}*, N{sub 2}{sup +}, and BN. Formation and decay of these species formed both from ablation of the target and from interactions with the background gas were investigated and provided insights into fundamental growth mechanisms of continuous, amorphous boron nitride thin films. The correlation of the plasma diagnostic results with film chemical composition and thickness uniformity studies helped to identify that a predominant mechanism for BN film formation is condensation surface recombination of boron ions and neutral atomic nitrogen species. These species arrive nearly simultaneously to the substrate location, and BN formation occurs microseconds before arrival of majority of N{sup +} ions generated by plume collisions with background molecular nitrogen. The energetic nature and extended dwelling time of incident N{sup +} ions at the substrate location was found to negatively impact resulting BN film stoichiometry and thickness. Growth of stoichiometric films was optimized at enriched concentrations of ionized boron and neutral atomic nitrogen in plasma near the condensation surface, providing few nanometer thick films with 1:1 BN stoichiometry and good thicknesses uniformity over macroscopic areas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noninvasive, real-time measurements of plasma parameters via optical emission spectroscopy

Plasma process control applications require acquisition of diagnostic data at a rate faster than the characteristic timescale of perturbations to the plasma. Diagnostics based on optical emission spectroscopy of intense emission lines permit rapid noninvasive measurements with low-resolution ({approx}1 nm), fiber-coupled spectrographs, which are included on many plasma process tools for semiconductor processing. Here the authors report on rapid analysis of Ar emissions with such a system to obtain electron temperatures, electron densities, and metastable densities in argon and argon/mixed-gas (Ar/N{sub 2}, Ar/O{sub 2}, Ar/H{sub 2}) inductively coupled plasmas. Accuracy of the results (compared to measurements made by Langmuir probe and white-light absorption spectroscopy) are typically better than {+-}15% with a time resolution of 0.1 s, which is more than sufficient to capture the transient behavior of many processes, limited only by the time response of the spectrograph used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of local thermodynamic equilibrium of laser induced Al{sub 2}O{sub 3}–TiC plasma in argon by spatially resolved optical emission spectroscopy

Plasma plume of Al{sub 2}O{sub 3}–TiC is generated by third harmonic Q-switched Nd:YAG nanosecond laser. It is characterized using Optical Emission Spectroscopy (OES) at different argon background gas pressures 10, 10{sup 2}, 10{sup 3}, 10{sup 4} and 10{sup 5} Pa. Spatial evolution of excitation and ionic temperatures is deduced from spectral data analysis. Temporal evolution of Ti I emission originated from different energy states is probed. The correlation between the temporal behavior and the spatial temperature evolution are investigated under LTE condition for the possibility to use the temporal profile of Ti I emission as an indicator for LTE validity in the plasma.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser Ablation Plasmas and Spectroscopy for Nuclear Applications

The development of measurement methodologies to detect and monitor nuclear-relevant materials remains a consistent and significant interest across the nuclear energy, nonproliferation, safeguards, and forensics communities. Optical spectroscopy of laser-produced plasmas is becoming an increasingly popular diagnostic technique to measure radiological and nuclear materials in the field without sample preparation, where current capabilities encompass the standoff, isotopically resolved and phase-identifiable (e.g., UO and UO[Formula: see text]) detection of elements across the periodic table. These methods rely on the process of laser ablation (LA), where a high-powered pulsed laser is used to excite a sample (solid, liquid, or gas) into a luminous microplasma that rapidly undergoes de-excitation through the emission of electromagnetic radiation, which serves as a spectroscopic fingerprint for that sample. This review focuses on LA plasmas and spectroscopy for nuclear applications, covering topics from the wide-area environmental sampling and atmospheric sensing of radionuclides to recent implementations of multivariate machine learning methods that work to enable the real-time analysis of spectrochemical measurements with an emphasis on fundamental research and development activities over the past two decades. Background on the physical breakdown mechanisms and interactions of matter with nanosecond and ultrafast laser pulses that lead to the generation of laser-produced microplasmas is provided, followed by a description of the transient spatiotemporal plasma conditions that control the behavior of spectroscopic signatures recorded by analytical methods in atomic and molecular spectroscopy. High-temperature chemical and thermodynamic processes governing reactive LA plasmas are also examined alongside investigations into the condensation pathways of the plasma, which are believed to serve as chemical surrogates for fallout particles formed in nuclear fireballs. Laser-supported absorption waves and laser-induced shockwaves that accompany LA plasmas are also discussed, which could provide insights into atmospheric ionization phenomena from strong shocks following nuclear detonations. Furthermore, the standoff detection of trace radioactive aerosols and fission gases is reviewed in the context of monitoring atmospheric radiation plumes and off-gas streams of molten salt reactors. Finally, concluding remarks will present future outlooks on the role of LA plasma spectroscopy in the nuclear community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emission spectroscopy of laser ablation plasma with time gating by acousto-optic modulator

The capability of acousto-optic modulator (AOM) to perform time-gated measurements for laser ablation plasma spectroscopy has been examined. Especially, we focused on the capability of the ''AOM gating'' to exclude the continuum and extremely broadened spectra usually observed immediately after the laser ablation. Final goal of the use of the AOM is to achieve considerable downsizing of the system for in situ and on-site analyses. In the present paper, it is shown that narrow and clear spectral lines can be obtained with the AOM gating even if the target is submerged in water. Also, application of this technique to the targets in air is demonstrated. It has been revealed that the AOM gating is fast enough to exclude the continuum and broadened lines, while effectively acquiring sufficiently narrow atomic lines lasting slightly longer than the continuum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applied spectroscopy in pulsed power plasmas

Applied spectroscopy is a powerful diagnostic tool for high energy density plasmas produced with modern pulsed power facilities. These facilities create unique plasma environments with a broad range of electron densities (10{sup 13}-10{sup 23} cm{sup -3}) and temperatures (10{sup 0}-10{sup 3} eV) immersed in strong magnetic (>100 T) and electric (up to 1 GV/m) fields. This paper surveys the application of plasma spectroscopy to diagnose a variety of plasma conditions generated by pulsed power sources including: magnetic field penetration into plasma, measuring the time-dependent spatial distribution of 1 GV/m electric fields, opacity measurements approaching stellar interior conditions, characteristics of a radiating shock propagating at 330 km/s, and determination of plasma conditions in imploded capsule cores at 150 Mbar pressures. These applications provide insight into fundamental properties of nature in addition to their importance for addressing challenging pulsed power science problems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Near-infrared spectroscopy for burning plasma diagnostic applications

Ultraviolet and visible (UV-VIS, 200-750 nm) atomic spectroscopy of neutral and ionized fuel species (H, D, T, and Li) and impurities (e.g., He, Be, C, and W) is a key element of plasma control and diagnosis on International Thermonuclear Experimental Reactor and future magnetically confined burning plasma experiments (BPXs). Spectroscopic diagnostic implementation and performance issues that arise in the BPX harsh nuclear environment in the UV-VIS range, e.g., degradation of first mirror reflectivity under charge-exchange atom bombardment (erosion) and impurity deposition, permanent and dynamic loss of window, and optical fiber transmission under intense neutron and {gamma}-ray fluxes, are either absent or not as severe in the near-infrared (NIR, 750-2000 nm) range. An initial survey of NIR diagnostic applications has been undertaken on the National Spherical Torus Experiment. It is demonstrated that NIR spectroscopy can be used for machine protection and plasma control applications, as well as contribute to plasma performance evaluation and physics studies. Emission intensity estimates demonstrate that NIR measurements are possible in the BPX plasma operating parameter range. Complications in the NIR range due to the parasitic background emissions are expected to occur at very high plasma densities, low impurity densities, and at high plasma-facing component temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗