Plasma Assisted Combustion and Chemical Processing: Chapter 9 - Plasma Diagnostics

Plasma dynamics and chemistry have a broad range of timescales from picoseconds to milliseconds. In addition, it involves nonequilibrium energy transfer between electrons, ions, electronically and vibrationally excited states, radicals, intermediate species, and reactants and products as well as surface charges and chemistry. To understand plasma physics and chemistry, it is essential to conduct time and space resolved, quantitative detection of nonequilibrium temperature distributions, electron energy and number density, electric field, and species concentrations. There are enormous publications and review articles on this subject. The focus of this chapter is to be placed on the most recent progress in gas phase plasma properties and chemistry, especially on optical emission spectroscopy, laser absorption spectroscopy, Faraday rotational spectroscopy, Raman and Thompson scattering, femtosecond and picosecond (fs/ps) coherent anti-Stokes Raman scattering (CARS) spectroscopy, and electric field-induced second harmonic generation methods.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fluorescence and absorption spectroscopy for warm dense matter studies and ICF plasma diagnostics

The burning core of an inertial confinement fusion (ICF) plasma produces bright x-rays at stagnation that can directly diagnose core conditions essential for comparison to simulations and understanding fusion yields. These x-rays also backlight the surrounding shell of warm, dense matter, whose properties are critical to understanding the efficacy of the inertial confinement and global morphology. In this work, we show that the absorption and fluorescence spectra of mid-Z impurities or dopants in the warm dense shell can reveal the optical depth, temperature, and density of the shell and help constrain models of warm, dense matter. This is illustrated by the example of a high-resolution spectrum collected from an ICF plasma with a beryllium shell containing native iron impurities. Lastly, analysis of the iron K-edge provides model-independent diagnostics of the shell density (2.3 × 10 24 e/cm 3 ) and temperature (10 eV), while a 12-eV red shift in Kβ and 5-eV blue shift in the K-edge discriminate among models of warm dense matter: Both shifts are well described by a self-consistent field model based on density functional theory but are not fully consistent with isolated-atom models using ad-hoc density effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spacelab 2 Plasma Diagnostics Package

The Plasma Diagnostics Package is a small, deployable satellite designed to study the interaction of the Space Shuttle Orbiter with the ionospheric environment as well as to be used in joint experiments with the plasma depletion and the vehicle charging and potential investigations during the Spacelab 2 mission. This paper provides a brief description of the small spacecraft, its instrumentation and operation, and the scientific objectives of the investigations. A brief summary of the scientific results obtained thus far is also presented.

Kurth, W. S.↗

Proposed framework for applying squeezed light to multi-photon absorption plasma diagnostics

We propose a quantum-enhanced plasma diagnostic based on squeezed states of light. Squeezed light can exhibit super-Poissonian photon statistics, leading to enhanced multiphoton absorption cross-sections compared to classical light. This effect enables improved sensitivity for two-photon excitation of high-energy atomic transitions such as ground-state excitation, and results in increased absorbed power and fluorescence in a plasma. We consider two methods of generating squeezed states and evaluate their advantages and limitations in the context of plasma absorption diagnostics. By comparing with and extending previous theoretical work, we predict an enhancement of the absorption signal by up to seven orders of magnitude at low intensities (10 1 W/m 2 ), with diminishing enhancement persisting up to high intensities (10 10 W/m 2 ). These results suggest that squeezed-light sources offer a viable pathway toward quantum-enhanced plasma diagnostics.

imaging↗

Structured light approaches in laser-based plasma diagnostics

There is a growing demand for plasma diagnostics suitable for industrial plasma reactors employed in semiconductor nanofabrication, especially relevant to microelectronics and quantum information systems. Such reactors typically have limited optical access and pose considerable diagnostic challenges, including intense background emission, significant thermal loads, and contamination of optical viewports. In this study, we outline research into structured light techniques (laser beams with tailored spatial, temporal, or phase characteristics) that effectively overcome these issues using laser-induced fluorescence (LIF) as an example. The focus of presented diagnostics is on ion kinetics analysis within an industrial plasma source, although this approach is broadly applicable to other plasma systems and diagnostic contexts. We present a confocal LIF implementation using an axicon-generated Bessel annular beam, achieving spatial resolutions of approximately 5 mm at a focal distance of 300 mm, with potential improvements to about 1 mm. This approach matches conventional orthogonal LIF performance but requires only one optical port. Wavelength-modulation LIF employs nonlinear laser wavelength tuning to measure spectral line derivatives, suppressing background emission and enhancing details of spectral line shape. Additionally, we present new results on applying vortex beams (laser beams carrying orbital angular momentum, OAM) for LIF measurements in an industrial plasma device. These measurements enable simultaneous axial and tangential velocity determination using a single laser beam and have been tested with xenon ion transition. Initial quantification of results was performed. Together, these structured-light approaches provide robust, background-resilient, multi-dimensional diagnostics for complex plasma environments.

Romadanov, Ivan [Princeton Plasma Physics Laborato↗

Recoverable Plasma Diagnostics Package (RPDP)

The recoverable plasma diagnostics package (RPDP) is an ejectable and recoverable satellite with flight and ground support systems so that it can be utilized in three modes: attached to an remote manipulator system; tethered; or as a subsatellite. The satellite is well instrumented with particle and field diagnostic as well as optical sensors to: investigate the dynamics of the natural environment or ejected perturbations from particle beams; measure the characteristics and propagation of electrostatic and electromagnetic waves; study wave particle interactions; and study natural properties of the magnetosphere, ionosphere, and upper atmosphere.

Roberts, W. T.↗

Recoverable Plasma Diagnostics Package (RPDP)

The recoverable plasma diagnostics package (RPDP) is an ejectable and recoverable satellite with flight and ground support systems so that it can be utilized in three modes: attached to an remote manipulator system; tethered; or as a subsatellite. The satellite is well instrumented with particle and field diagnostic as well as optical sensors to: investigate the dynamics of the natural environment or ejected perturbations from particle beams; measure the characteristics and propagation of electrostatic and electromagnetic waves; study wave particle interactions; and study natural properties of the magnetosphere, ionosphere, and upper atmosphere.

Roberts, B.↗

Interpretation of plasma diagnostics package results in terms of large space structure plasma interactions

The Plasma Diagnostics Package (PDP) is a spacecraft which was designed and built at The University of Iowa and which contained several scientific instruments. These instruments were used for measuring Space Shuttle Orbiter environmental parameters and plasma parameters. The PDP flew on two Space Shuttle flights. The first flight of the PDP was on Space Shuttle Mission STS-3 and was a part of the NASA/Office of Space Science payload (OSS-1). The second flight of the PDP was on Space Shuttle Mission STS/51F and was a part of Spacelab 2. The interpretation of both the OSS-1 and Spacelab 2 PDP results in terms of large space structure plasma interactions is emphasized.

Kurth, William S.↗

Additive Manufacture of Plasma Diagnostic Components Final Report Phase II

There is now a well-established set of plasma diagnostics (see e.g. [3]), but these remain some of the most expensive assemblies in fusion systems since for every system they have to be custom built, and time for diagnostic development can pace the project. Additive manufacturing (AM) has the potential to decrease production cost and significantly lower design time of fusion diagnostic subsystems, which would realize significant cost reduction for standard diagnostics. In some cases, these basic components can be additively manufactured for less than 1/100th costs of conventional manufacturing.In our DOE Phase II SBIR, we examined the impact that AM can have on plasma diagnostic cost by taking 15 separate diagnostics through an engineering design using Conventional Manufacturing (CM) techniques, then optimizing the design to exploit the benefits of AM. The impact of AM techniques on cost is found to be in several areas. First, the cost of materials falls because AM parts can be manufactured with little to no waste, and engineered to use less material than CM. Next, the cost of fabrication falls for AM parts relative to CM since the fabrication time can be computed exactly, and often no post-processing is required for the part to be functional. We find that AM techniques are well suited for plasma diagnostics since typical diagnostic complexity comes at no additional cost. Cooling channels, for example, can be builtin to plasma-facing components at no extra cost. Fabrication costs associated with assembly are lower for AM parts because many components can be combined and printed as monoliths, thereby mitigating the need for alignment or calibration. Finally, the cost of engineering is impacted by exploiting AM design tools that allow standard components to be customized through web-interfaces. Furthermore, we find that concept design costs can be impacted by scripting interfaces for online engineering design tools.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

STS-3/OSS-1 Plasma Diagnostics Package (PDP) measurements of the temperature pressure and plasma

Designed to withstand the thermal extremes of the STS-3 mission through the use of heaters and thermal blankets, the plasma diagnostics package sat on the release/engagement mechanism on the OSS-1 payload pallet without a coldplate and was attached to the RMS for two extended periods. Plots show temperature versus mission elapsed time for two temperature sensors. Pressure in the range of 10 to the -3 power torr and 10 to the -7 power torr, measured 3 inches from the skin of the package is plotted against GMT during the mission. The most distinctive feature of the pressure profile is the modulation at the obit period. It was found that pressure peaks when the atmospheric gas is rammed into the cargo bay. Electric and magnetic noise spectra and time variability due to orbiter systems, UHF and S-band transmitter field strengths, and measurements of the ion spectra obtained both in the cargo bay and during experiments are plotted.

Shawhan, S. D.↗

Description of the plasma diagnostics package (PDP) for the OSS-1 Shuttle mission and JSC plasma chamber test in conjunction with the fast pulse electron gun (FPEG)

The objectives, equipment, and techniques for the plasma diagnostics package (PDP) carried by the OSS-1 instrument payload of the STS-4 and scheduled for the Spacelab-2 mission are described. The goals of the first flight were to examine the Orbiter-magnetoplasma interactions by measuring the electric and magnetic field strengths, the ionized particle wakes, and the generated waves. The RMS was employed to lift the unit out of the bay in order to allow characterization of the fields, EM interference, and plasma contamination within 15 m of the Orbiter. The PDP will also be used to examine plasma depletion, chemical reaction rates, waves, and energized plasma produced by firing of the Orbiter thrusters. Operation of the PDP was carried out in the NASA Space Environment Simulation Laboratory test chamber, where the PDP was used to assay the fields, fluxes, wave amplitudes, and particle energy spectra. The PDP instrumentation is also capable of detecting thermal ions, thermal electrons suprathermal particles, VHF/UHF EMI levels, and the S-band field strength.

Shawhan, S. D.↗

PLASMA DIAGNOSTIC POTENTIAL OF 2p4f IN N{sup +}—ACCURATE WAVELENGTHS AND OSCILLATOR STRENGTHS

Radiative emission lines from nitrogen and its ions are often observed in nebula spectra, where the N{sup 2+} abundance can be inferred from lines of the 2p4f configuration. In addition, intensity ratios between lines of the 2p3p-2p3s and 2p4f-2p3d transition arrays can serve as temperature diagnostics. To aid abundance determinations and plasma diagnostics, wavelengths and oscillator strengths were calculated with high precision for electric dipole (E1) transitions from levels in the 2p4f configuration of N{sup +}. Electron correlation and relativistic effects, including the Breit interaction, were systematically taken into account within the framework of the multiconfiguration Dirac-Hartree-Fock method. Except for the 2p4f-2p4d transitions with quite large wavelengths and the two-electron-one-photon 2p4f-2s2p {sup 3} transitions, the uncertainties of the present calculations were controlled to within 3% and 5% for wavelengths and oscillator strengths, respectively. We also compared our results with other theoretical and experimental values when available. Discrepancies were found between our calculations and previous calculations due to the neglect of relativistic effects in the latter.

79 ASTRONOMY AND ASTROPHYSICS↗

Polarization-separated double-imaging spectroscopy for weakly-ionized plasma diagnostics

Laser Thomson scattering, which provides thermal properties of electrons, has been extensively utilized in plasma diagnostics. However, being a non-resonant linear light scattering technique, it often encounters several challenges in weakly-ionized plasma diagnostics due to spectral overlap with different scatterings induced from other existing species, including Mie, Rayleigh, and rotational Raman scatterings. To address this challenge, we propose an imaging spectroscopy technique, polarization-separated double-imaging spectroscopy (PoDIS), which selectively separates specific scatterings based on their polarization characteristics. Using an atmospheric plasma jet as a plasma source for demonstration, we show that PoDIS can effectively separate rotational Raman and Thomson scatterings from a superimposed spectrum without prior knowledge or assumptions about the thermal properties of neutrals or electrons. This separation enables independent fitting of the rotational Raman and Thomson scattering spectra, allowing for precise determination of the thermal properties of neutral particles and electrons separately.

Bak, Junhwi [Texas A&M University, College Station↗

A comparative study of electrical probe techniques for plasma diagnostics

Techniques for using electrical probes for plasma diagnostics are reviewed. Specific consideration is given to the simple Langmuir probe, the symmetric double probe of Johnson and Malter, the variable-area probe of Fetz and Oeschsner, and a floating probe technique. The advantages and disadvantages of each technique are discussed.

Szuszczewicz, E. P.↗

Millimeter-wave system-on-chip advancement for fusion plasma diagnostics

Recent advances in radio-frequency system-on-chip technology have provided mm-wave fusion plasma diagnostics with the capability to overcome major challenges such as space inefficiency, inflexible installation, sensitivity, susceptibility to EMI, and prohibitively high cost of conventional discrete component assemblies as higher imaging resolution and data accuracy are achieved by increasing the number of channels. Nowadays, shrinking transistor gate lengths on fabrication techniques have enabled hundreds of GHz operation, which is suitable for millimeter-wave diagnostics on current and future tokamaks. The Davis Millimeter Wave Research Center (DMRC) has successfully developed V-band (55-75 GHz) transmitter and receiver chips for Microwave Imaging Reflectometer (MIR) instruments. The transmitter can illuminate 8 different frequencies simultaneously within 55-75 GHz. Moreover, the receiver has the capability to amplify the reflected signal (>30 dB) while offering 10-30× reduction in noise temperature compared to current MIR instruments. Plasma diagnostics requires ultra-wideband (more than 20 GHz) operation which is approximately nine times wider bandwidth than the recent commercial impetus for communication systems. Current efforts are underway for gallium-arsenide monolithic microwave integrated circuit receiver chips at W-band (75-110 GHz) and F-band (90–140 GHz) permitting measurements at higher toroidal magnetic fields.

47 OTHER INSTRUMENTATION↗