Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phasor measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analytical Identification Method of Generalized Short‐Circuit Ratio Using Phasor Measurement Units

This paper introduces a novel analytical approach for the identification of the admittance matrix and the generalized short-circuit ratio (gSCR) in power systems integrated with renewable energy sources. The proposed method leverages voltage and current measurements from phasor measurement units (PMUs) to construct a least squares objective function, which is then solved using matrix calculus and partial derivatives. Unlike conventional optimization algorithms, this approach provides an analytical solution that substantially reduces data requirements, enabling the efficient and accurate identification of the gSCR with smaller datasets. Additionally, its fixed computational complexity allows for real-time updates as new data are collected, ensuring continuous refinement of the system of equations and enabling rapid, precise gSCR calculations. The method also exhibits strong robustness against measurement noise, making it well-suited for practical applications in dynamic power systems. The combination of reduced data requirements, real-time adaptability, noise robustness and fixed computational load establishes this method as a highly efficient and reliable tool for real-time power system stability analysis. Case studies on an EPRI 36-bus system demonstrate the method's effectiveness, highlighting its accuracy in closely matching true gSCR values, even under diverse disturbances and noisy conditions.

Han, Zelei [Hohai University, Nanjing (China)] (OR↗

Precise synchronization of phasor measurements in electric power systems

Phasors representing positive sequence voltages and currents in a power network are in the most important parameters in several monitoring, control, and protection functions in interconnected electric power networks. Recent advances in computer relaying have led to very efficient and accurate phasor measurement systems. When the phasors to be measured are separated by hundreds of miles, it becomes necessary to synchronize the measurement processes, so that a consistent description of the state of the power system can be established. Global Positioning System (GPS) transmissions offer an ideal source for synchronization of phasor measurements. The concept and implementation of this technique are described. Several uses of synchronized phasor measurements are also described. Among these are improved state estimation algorithms, state estimator enhancements, dynamic state estimates, improved control techniques, and improved protection concepts.

Phadke, Arun G.↗

Offline Power Systems Applications Enabled by Phasor Measurement Units: Technical Assistance to the Power Sectors of Southeast Asia

This report provides a brief overview of several offline (non-real-time) applications facilitated by high-resolution time-synchronized measurements recorded by phasor measurement units (PMUs). The high reporting rate and time-synchronization of PMU records provide a detailed view of power system dynamics, enabling electric utilities to obtain a better understanding of their systems. In this report, the following applications have been reviewed: Power plant model validation, System model validation, Ringdown oscillation analysis, Frequency response analysis, Postmortem analysis of disturbance events Along with a brief technical background of the applications above, applicable North American Electric Reliability Corporation (NERC) standards have been discussed, and examples of implementation in North American organizations have been provided. Implementing several of the discussed applications may need a preliminary stage of data gathering from multiple entities, and several frameworks and process flows have been formulated by organizations around the world for this purpose. However, the data-gathering stage has not been considered in the scope of the present report.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

GPS Spoofing Mitigation and Timing Risk Analysis in Networked Phasor Measurement Units via Stochastic Reachability

To address phasor measurement unit (PMU) vulnerability to spoofing, we propose the use of a set-valued state estimation technique known as stochastic reachability (SR)-based distributed Kalman filter (DKF) that computes secure global positioning system (GPS) timing across a network of receivers. Utilizing SR, we estimate not only GPS time but also its stochastic reachable set, which is parameterized by probabilistic zonotope (p-Zonotope). While requiring known measurement error bounds in only non-spoofed conditions, we designed a two-tiered approach. We first performed measurement-level spoofing mitigation via deviation of a measurement innovation from its expected p-Zonotope. We then performed state-level timing risk analysis via a determination of the intersection probability of the estimated p-Zonotope with an unsafe set that violates IEEE C37.118.1a-2014 standards. Finally, we validated our SR-DKF algorithm by subjecting it to a simulated receiver network to coordinate signal-level spoofing. We demonstrate improved timing accuracy and successful spoofing mitigation via the use of our SR-DKF algorithm. We also validated the robustness of the estimated timing risk as the number of receivers were varied.

47 OTHER INSTRUMENTATION↗

Extended real-time voltage instability identification method based on synchronized phasor measurements

This paper presents an extended adaptive approach designed to accurately estimate the Thévenin equivalent parameters using phasor measurements at a given bus for measurements lying in any of four quadrants of the PQ-plane. The improvement is achieved by using a new condition to properly update the estimated parameters after an initial guess. Based on an adaptive philosophy, the proposed approach can correctly account for the intrinsic nonlinearities of a power system, can provide a real-time estimation of Thévenin parameters, and does not require network topology knowledge. The method is validated using the Kundur 2-area system, showing estimation improvements compared to the current adaptive approach and the classical recursive least-squares method. The proposed approach is able to estimate both sides of the system with respect to the measurement bus. In addition, a data-driven voltage stability index is developed. To illustrate the performance of the proposed approach in a larger power system, a voltage stability assessment is carried out on the IEEE 39-bus system, considering the action of overexcitation limiters of generators and nonlinear loads. The proposed approach is suitable for applications that require an accurate Thévenin equivalent estimation in real-time, such as for voltage stability assessment. The new approach provides a reliable tool for the system operators to make proper and timely decisions.

42 ENGINEERING↗

Inverter Model Validation and Calibration Using Phasor Measurement Unit Data

As the penetration of inverter-based renewable energy resources increases in the power grid, especially at the distribution and microgrid levels, the need to accurately represent them in planning studies increases as well. However, due to the lack of well-established standard procedures, and vendor reluctance towards the detailed sharing of proprietary models, automated dynamic model validation and parameter calibration tools for inverter based resources (IBRs) remain scarce. This work presents a model validation and parameter calibration platform for representing IBRs with generic phasor-domain models. Phasor measurements of power system events are used for continuous validation using the data playback method, and model parameters are re-calibrated if a significant mismatch between measurements and model response is observed. Unique features of the proposed platform include- (a) an iterative Bayesian optimization approach towards parameter calibration to address a possible mismatch between the structures of generic models implemented in simulation softwares and actual commercial inverters, (b) error metrics designed to account for a possible mismatch between the time resolution of simulation and measurements, and (c) analysis of the measurement-simulation mismatch to provide guidance to engineering personnel regarding model shortcomings. The performance of the platform has been illustrated using both simulated data and field measurements to validate/calibrate inverter models in GridLAB-D.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online Monitoring Applications Enabled by Phasor Measurement Units: Technical Assistance to the Power Sectors of Southeast Asia

In this report, an overview of several online applications enabled by PMU measurements is provided. Besides a brief technical background for each application, the report also discusses control room displays and alarming methodologies used by North American organizations, and applicable standards set by the North American Electric Reliability Corporation (NERC). The five applications discussed herein are inertia monitoring, linear state estimation, voltage stability monitoring, small-signal stability monitoring, and forced oscillation monitoring.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inertia Estimation and Trend Analysis of the United States Power Grid Interconnections

The transition from conventional to modern power systems is causing an increase in integration of inverter-based resources (IBRs). This generally leads to a decrease in total system inertia, which in-turn increases the system’s rate-of-change-of-frequency (RoCoF) during disturbances. This poses a threat to the frequency stability of the system and may falsely trigger protective devices. To monitor system status and plan for integrating renewable energy sources like photovoltaic, wind, and energy storage systems, a realistic study of inertia estimation and analysis in the United States (US) over the past decade is needed. This paper uses field-measured phasor measurement unit (PMU) data collected throughout the US from 2013 to 2023 via the Frequency Monitoring Network (FNET/GridEye) operated by the University of Tennessee, Knoxville (UTK) and Oak Ridge National Laboratory (ORNL). The collected PMU frequency data is utilized to estimate the system inertia of the three US interconnections: Eastern, Western, and Texas. Various RoCoF time windows are investigated for estimating the inertia of each interconnection by maximizing the correlation coefficient between the measured RoCoF and power mismatch. The resulting inertia trends over the past decade show approximately a 6% decline in inertia in the Eastern interconnection, a 15% decline in inertia in the Western interconnection, and a 16% increase in inertia in Texas. Key insights into how inertia is changing amidst the complex energy landscape are extracted using the fuel mix trend data. This provides valuable information for future energy strategies and planning.

30 DIRECT ENERGY CONVERSION↗

Spatio-Temporal Deep Graph Network for Event Detection, Localization, and Classification in Cyber-Physical Electric Distribution System

This work proposes a deep graph learning framework to identify, locate, and classify power, cyber, and cyber power events at the distribution system level. The proposed algorithm jointly exploits spatial, temporal, and node-level cyber and physical data features. The developed graph neural network, together with a deep autoencoder, utilizes physical measurements from distribution level phasor measurement units and cyber data from communication network logs. The spatial structure of the synchrophasor measurements and network is incorporated through a weighted adjacency matrix. The temporal structure is incorporated by defining a spatial operation in the gated recurrent unit. This spatio-temporal learning element resides inside a power event detection, localization, and classification module that provides the degree of confidence for an event label. To accurately pinpoint the location of an event to the nearest bus equipped with a measurement unit, a combination of squared error and proximity score is utilized. Also included is a cyber event detection module that employs heteroskedasticity to analyze the significance of various cyber features during different types of attacks. Finally, a dual-bit cyber-power decision table determines the nature of the event. The proposed method is validated on two distribution systems modeled in OPAL-RT/Hypersim with limited phasor measurement units for different possible physical and cyber events. Further analyses include comparison with other state-of-the-art methods and validation in the presence of measurement noise. As a result, our method outperforms existing approaches and achieves an average detection accuracy of 97.97%, F1-score of 96.88%, precision of 96.53%, and recall of 98.57%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precise time dissemination and applications development on the Bonneville Power Administration system

The Bonneville Power Administration (BPA) uses IRIG-B transmitted over microwave as its primary system time dissemination. Problems with accuracy and reliability have led to ongoing research into better methods. BPA has also developed and deployed a unique fault locator which uses precise clocks synchronized by a pulse over microwaves. It automatically transmits the data to a central computer for analysis. A proposed system could combine fault location timing and time dissemination into a Global Position System (GPS) timing receiver and close the verification loop through a master station at the Dittmer Control Center. Such a system would have many advantages, including lower cost, higher reliability, and wider industry support. Test results indicate the GPS has sufficient accuracy and reliability for this and other current timing requirements including synchronous phase angle measurements. A phasor measurement system which provides phase angle has recently been tested with excellent results. Phase angle is a key parameter in power system control applications including dynamic braking, DC modulation, remedial action schemes, and system state estimation. Further research is required to determine the applications which can most effectively use real-time phase angle measurements and the best method to apply them.

K. E. Martin↗

Synchrophasors-based Master State Awareness Estimator for Cybersecurity in Power Grid: Testbed Implementation & Field Demonstration

The integration of distributed energy resources(DERs) and expansion of complex network in the distribution grid requires an advanced distributed state estimator to monitor the grid health at micro-level. The distribution state estimator will improve the situational awareness and resiliency of distributed power system. This paper proposes a synchrophasors-based master state awareness (MSA) estimator to enhance the cybersecurity in distribution grid by providing a real-time estimation of system operating states to control center operators. In this paper, the proposed MSA estimator utilizes only phasor measurements, bus magnitudes and angles, from phasor measurement units (PMUs),deployed in local substations, to estimate the system states and also detects data integrity attacks, such as load tripping attack that disconnects the load. To validate the proof of concept, we implement the proposed methodology in cyber-physical testbed environment at the Idaho National Laboratory (INL) Electric Grid Security Testbed. Further, to address the “valley of death” and support technology commercialization, field demonstration is also performed at the Critical Infrastructure Test Range Complex(CITRC) at the INL. Our experimental results reveal a promising performance in detecting load tripping attack and providing an accurate situational awareness through an alert visualization dashboard in real-time

42 ENGINEERING↗

Changes Required in the PMU standards

The Phasor Measurement Unit (PMU) is a representational measuring instrument that gives time-stamped measurements of the power system on the assumption that the measurand can be represented as sinusoidal. However, two standards defining the measured quantities unnecessarily corrupt the results and limit the capabilities of the PMU, and are beginning to tax communications systems. This paper examines the two mistakes in the PMU standards, and proposes a solution.

PMU measurement, phase, phasor, measurement theory↗

Online Output-Based Inertia Estimation of Modern Power Systems

The overall inertia of modern power systems is drastically impacted by the penetration level of converter-based resources (CBRs). The intermittent output of CBRs and their dependence on the weather conditions affirm the need for a realtime inertia estimation approach. This can help the transmission system operators(TSOs) to be continuously aware of the changes in the system inertia and to take suitable control actions. This paper is a step forward to a totally data-driven framework for power system inertia estimation using the available measurements from the phasor measurement units (PMUs). This inertia estimation is done based on the spectral analysis of the so-called Koopman linear operator. Koopman operator considers the relationship between the system's inertia and its dynamical response to slight disturbances in the load. Simulation results show that Koopman operator can approximate the system behavior in a reconstructed linear space hence inertia constant is estimated accurately.

data-driven↗

Bi-Level Linear Programming Model for Automatic Load Shedding: A Distributed Wide-Area Measurement System-based Solution

Load shedding is currently implemented as a two-step based approach. In the first step, manual load shedding is taken place, were system operators, using estimates, inform distribution utilities of predicted stressful conditions. Information provided include the potential use of energy reserves, as well as load shedding amount. In a second step, automatic load shedding is done. The latter is realized using protection relays. While considering frequency variation, pre-defined values of load to be shed and correspondent number of stages for such to be realized are transformed into relay settings. Under-frequency protection relays use only local measurements towards decision making, thus operate in a decentralized architecture. Decision making is done in milliseconds plus breaker time. While this approach has provided much system reliability, considering the new smart grid paradigm, where system dynamics are much faster due to increasing renewable resources penetration, in some operating conditions it will generate sub-optimal solutions, such as islanding. Phasor measurement units provide a source of information which can be useful for this problem. Centralized architecture-based solutions for automatic load shedding, as present in the state-of-the-art, require though total processing times which are not acceptable for real-life implementation. In this work, considering the above, a bi-level linear programming model is presented. The model is implemented considering a distributed architecture while leveraging phasor measurement units data. The upper-level model estimates the current system state. Results of this model are embedded in a lower-level model, which decision variables are the location and load value to be shed. Easy-to-implement model, built-on the classic weighted least squares solution, highlight potential aspects towards real-life applications.

Bretas, Arturo Suman↗

Optimal PMU design based on sampling model and sensitivity analysis

The precise measurements of the synchrophasor and frequency from phasor measurement units (PMUs) are widely used in power grid applications. With the improvement of the technique, applications always require stable dynamic performance and higher accuracy for the synchrophasor and frequency measurements, which is challenging for PMU development. To evaluate the contribution of PMU hardware to measurement accuracy, this paper proposes a general-purpose sampling model to analyze the measurement error. In the proposed sampling model, a strict mathematical derivation is derived, where its error is purely determined by the parameters of the PMU hardware. The sensitivity analysis is carried out by three methods, including mathematical analysis, computer simulation, and variance-based sensitivity analysis. Through the sensitivity analysis, this paper establishes the systematic formulation and the inclusion of synchrophasor, frequency, and ROCOF. Experimental results based on the real-world testbench involving distribution-level PMUs match the mathematical analysis conclusion, which verifies the correctness of the general-purpose sampling model. Furthermore, a strategy for the optimal PMU design is proposed, which could guide PMU design in the future.

42 ENGINEERING↗

Proactive Frequency Stability Scheme via Bayesian Filters and Synchrophasors

Underfrequency (UF) load shedding schemes are traditionally implemented in two ways: One approach is based on manual load shedding, with system operators requesting loads to be shed ahead of anticipated stressful operating conditions. Manual load shedding is usually done through phone calls. The second method is automatic load shedding via underfrequency relays. Using static static settings, these schemes can be designed to operate in stages and drop previously identified loads. The main limitation of traditional load shedding schemes is that they are reactive and leave little room for optimized corrective actions. This work presents a proactive and automatic underfrequency load shedding solution for power systems. Measurements are captured via phasor measurement units (PMUs) at relatively low sampling rates of 30 Hz. These measurements are then processed by particle filters who predict the future state of the system's frequency. Based on these predictions excess load is determined and shed. Comparative case studies are performed in simulated environments. Easy-to-implement models, without hard-to-derive parameters, highlight potential aspects for real-life implementation.

Paramo, Gian↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

With the increased requirements of real-time grid monitoring, disturbance location, and situation awareness, Phasor Measurement Units (PMUs) have become more critical for the Wide Area Measurement System (WAMS). However, the vulnerability of PMUs has not been well studied, especially under electromagnetic pulse (EMP) scenarios. The stable operation of the power system will be affected directly once EMP damages them. Therefore, studying their immunity to EMP events is urgent and necessary. In this paper, the effective impedance measurement scheme and pulsed current injection (PCI) testing are proposed for the port impedance measurement and immunity levels of PMUs. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then, the circuit of the pulsed current generator is set to generate a damping sinusoid, and the double exponential wave is applied to the port. Finally, using measured impedance as a generator load, the voltage and current responses of different ports are calculated in the PCI testing simulation. In conclusion, results reveal the characteristics of port impedance, waveforms of voltage and current, and distribution of accumulative energy. The relation between port impedance and the waveforms is discussed.

42 ENGINEERING↗