Pioneer 7 TDS performance evaluation
Performance evaluation of near-earth and deep space tracking facilities for Pioneer 7 space probe
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Performance evaluation of near-earth and deep space tracking facilities for Pioneer 7 space probe
This paper presents performance evaluation of a new distributed energy resource management system (DERMS) algorithm via an advanced hardware-in-the-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory environment, including the accurate modeling of sub-transmission and distribution networks, the DERMS software controller, and 84 power hardware solar photovoltaic (PV) inverters, standard communication protocols, and a capacitor bank controller. The DERMS algorithm is also called, Grid-Optimization of Solar (GO-Solar) platform which includes predictive state estimation (PSE) and online multiple objective optimization (OMOO) to dispatch the legacy devices and distributed energy resources (e.g., PV). The voltage regulation performance is evaluated under three scenarios, volt-var smart inverter (baseline), and DERMS control for 100% and 30% of PV. The results show that controlling 30% of PV systems with the GO-Solar platform may provide the best balance of control performance and implementation cost.
The performance of model predictive control (MPC) can be significantly affected by different choices of controller parameters such as the time intervals for model discretization and control sampling. Due to the lack of a systematic understanding on how these parameters affect control performance, they are usually selected arbitrarily in practice.In this paper, the combined impacts of selected time intervals for model discretization and control sampling on the performance of MPC are comprehensively investigated for the first time through detailed simulations. Specifically, a typical MPC strategy is first designed to improve building operations based on a reduced-order model of building dynamics. Then, the performance of the designed MPC is evaluated against different choices of time intervals for model discretization and control sampling on a simulated office building. The detailed simulation results reveal that the time interval for model discretization has a much greater influence on the performance of MPC than the time interval for control sampling. Although the time interval for control sampling usually receives more attentions in practice, it turns out that the time interval for model discretization affects the prediction performance, cost saving, and computation time simultaneously and more significantly. Therefore, the simulation-based performance evaluation presented here sheds light on the impacts of different time intervals and facilitates their selection for practical applications of MPC to building operations
Testing system studies inertial characteristics of gyroscopic devices. System consisting of instrument support package, dynamic test table, torque control electronics, and real-time computer evaluates performance of prototype gyroscopic strapdown units in inertial-grade attitude-reference systems. System is applicable to commercial aircraft.
Space shuttle guidance, evaluating performance of strapdown and gimballed systems by nominal and abort trajectories
Federated machine learning (FL) is gaining significant popularity to develop cybersecurity solutions in power grids because of its advanced capability to support decentralized data handing at local devices, its privacy preservation, and its low-bandwidth requirement. However, the evolving adversarial machine learning (AML) threats raise significant concerns for the cybersecurity of FL architectures. The FL-based split neural network (SplitNN) achieves high performance through the decentralized training of local neural network models while preserving data privacy across multiple entities. In this paper, we propose a methodology for evaluating the performance of a vertical FLbased anomaly detector against different types of AML attacks, including denial-of-service attacks, adversarial data injection attacks, and replay attacks on the trained local models deployed in the grid network. For a case study, we consider the modified IEEE 13-bus system, and we develop SplitNN-based binary and multiclass classification models to detect, locate, and identify different types of data integrity attacks on the volt-watt control with two pooling layers: maximum pooling and AvgPool. Our experimental results, computed through performance metrics, reveal that the severity of these AML attacks varies with the integrated pooling mechanism, the type of classification model, and the nature of the cyberattack. Further, the AML attacks negatively impacted the prediction time per sample for the pretrained SplitNN during the online testing.
Not Available
A measurement-based performance evaluation technique has been used to characterize the OS performance of Cedar, a hierarchical shared-memory multiprocessor system. Thirteen OS performance meters were used to capture the operating system activities for compute-bound workloads. Three representative applications from the Perfect Benchmark Suite were used to measure the OS performance in a dedicated system and in multiprogrammed workloads. It was found that 13-23 percent of the total execution time on a dedicated system was spent in executing OS-related activities. Under multiprogramming, 12-14 percent of the total execution time was used by the OS. The impact of multiprogramming on the operating system performance meters was also measured.
TRISO Fuel Performance Evaluation outlining design and radionuclide source term, fuel performance during normal operation, fuel performance during core heatup accidents, other accident scenarios, and GenIV VHTR Fuel and Fuel Cycle PMB.
An efficient computational technique is developed to evaluate the performance of coherent receivers with noisy carrier reference and multiple antennas. The received signal is assumed to be uncoded residual carrier BPSK (binary phase shift keying), with a PLL (phase locked loop) used for extracting the carrier. Explicit relationships between the error probabilities and the various system parameters are given. Specific results are given for the performance gain of combined carrier referencing over baseband only combining when the channel alignment process is ideal. A simple asymptotic expression for the performance gain is determined when the number of antennas used is increased without bound. An example using a Block 3 Deep Space Network PLL illustrates the performance of each arraying structure. The technique used is applicable to the performance evaluation for other receivers having similar decision statistics.
Computer performance evaluation techniques
The performance of rechargeable batteries is fundamentally influenced by the physicochemical properties and microstructural features of their key material components. Recent experimental advancements have highlighted the potential of single-crystal (SC) morphologies to address inherent limitations of polycrystalline (PC) electrodes and solid-state electrolytes, offering tunable charge transport kinetics and improved cell cycling performance. Here, this review examines how state-of-the-art computational modeling, from atomistic and mesoscale to continuum-level approaches, including machine learning methodologies, has been utilized to investigate the critical factors governing the electrochemical behavior of SC battery materials. We explore how predictive modeling can elucidate the processing–structure–property–performance relationships of SC cathodes, anodes, and solid-state electrolytes, with a focus on unique SC characteristics such as crystallographic anisotropy, size effects, and facet-dependent properties. Additionally, we identify limitations in commonly used modeling techniques and discuss strategies to address these challenges. By integrating high-fidelity simulations with experimental insights, this review aims to outline a clear path for the rational design and optimization of SC battery components, paving the way for accelerated advancements in energy storage technologies.
The results of S190A sensor performance evaluation are summarized based on data presented by all contributors to the sensor performance evaluation interim reports. Techniques used in sensor performance evaluation are discussed. Topics discussed include: performance degradation identified during the Skylab missions, S190A and EREP system anomalies that affected S190A performance, and the performance achieved, in terms of pertinent S190A parameters. Additional analyses include final performance analyses completed after submittal of the SL4 interim sensor performance evaluation reports, including completion of detailed analyses of basic performance parameters initiated during the interim report periods and consolidation analyses to reduce independent mission data (SL2, SL3, and SL4) to determine overall performance realized during all three Skylab missions.
The results are summarized of S193 altimeter sensor performance evaluation based on data presented to the sensor performance evaluation interim reports. The results of additional analyses of S193 altimeter performance are presented, and techniques used in sensor performance evaluation are described. Significant performance degradation identified during the Skylab missions and the performance achieved are described in terms of pertinent S193 altimeter parameters. The additional analyses include final performance analyses completed after submittal of the SL4 interim sensor performance evaluation reports, including completion of detailed analyses of basic performance parameters initiated during the interim report periods.
In this study, we evaluated the performance of the United States Geological Survey velocity model developed for the San Francisco Bay Area (SFBA), version 21.1. The evaluation was performed through high-resolution three-dimensional physics-based ground motion simulations of seven small-magnitude earthquakes (ranging from magnitude 3.8 to 4.4) that occurred on the eastern side of the San Francisco Bay. The simulations were performed in the frequency range from 0 to 5 Hz with a minimum shear-wave velocity of 250 m/s, which allowed the capture of wave propagation effects of the near-surface soft materials that characterize local basins. Based on the direct comparison of Fourier amplitude spectra between recorded and simulated ground motions for more than 250 stations, we found that the velocity model generally performs well in the frequency range of 0.2–5 Hz. The median value of the Fourier amplitude residuals was found to be near zero for all seven earthquakes. The slight over-prediction of 0.2 log-natural units at frequencies above 3 Hz in our simulations was attributed to the potentially inaccurate representation of the source radiation pattern by a double-couple point source model, and simple representation of shallow small-scale underground structural complexity in the velocity model. Maps of spectral amplitude differences between the simulated and recorded data were used to identify areas responsible for systematic ground motion over-predictions or under-predictions. For example, while some sub-domains over soft sediments show over-prediction patterns, the block east of the Hayward fault is prone to exhibit patterns of under-prediction. These maps can be used to guide future refinements of the SFBA velocity model. Since our simulation methodology allows for the decoupling of the source and wave propagation effects, the ground motion data generated by our simulations can also be used to quantify the epistemic uncertainty due to the velocity model, in empirically based ground motion estimates for the SFBA.
A remote manipulator performance evaluation test was developed to test certain tool mating configurations not possible with the standard peg-in-hole type of test. The test attempted to evaluate robot manipulator performance over a full range of six degrees of freedom of motion between a tool and its intended receptacle. The test consists primarily of four different tool geometries and three different receptacle geometries which provide for a progressive reduction in the degrees of freedom of motion, and a progressive increase in the degrees of constraint (DOC) over motion, between the tool and the receptacle. The manipulation times of actual tools and couplings would be predicted by the times for the test tool most like it geometrically. In addition, the influence of four different transmission delays was tested. The results indicate that tool manipulation time can vary by a factor of about four depending on the degrees of constraint over final tool positioning.
Performance evaluation of GEOS-2 spacecraft operation and geodetic systems
Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.