Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Perennial stream”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nonintrusive Diagnostic Strategies for Arcjet Stream Characterization

In the previous lecture, the issues related to arcjet flow modeling were introduced, and the limitations of conventional instrumentation in addressing these issues were discussed. The general level of understanding of the arcjet flows was seen to preclude the use of arcjets as aerothermodynamic test facilities beyond the current role in aerothermal material testing, despite their long test duration capability. In this section, the focus will be on new developments in spectroscopic instrumentation and techniques that can be brought to bear on the fundamental problem of arcjet stream characterization. Although a wide selection of arcjet facilities were introduced in the previous section, the discussion of nonintrusive diagnostic instrumentation will be restricted to the large-scale, segmented, constricted-arc heater facilities that are most widely used in thermal protection material testing for aerospace applications. After a brief review of the important features of arcjet flows, the topic of nonintrusive, optical diagnostics is introduced with a discussion of some of the basic aspects of radiative transitions. The lecture is then organized into two sections covering emission measurements and laser-induced fluorescence measurements. Emission measurements are presented next for different regions of arcjet flows, while the fluorescence measurements are presented for the free stream region only. Summaries are given for each of the two main sections, and observations on arcjet characterization by optical diagnostics in general are given at the end.

Douglas G Fletcher

Design and Performance of an Experimental Annular Turbojet Combustor With High-Velocity-Air Admission Through One Wall

An experimental, annular, turbojet combustor was designed to eliminate the conventional combustor-inlet diffuser. Instead, high-velocity air was supplied directly to the combustor. This stream was split into two parts: (1) the primary in which combustion was sustained, and (2) the secondary in which the stream momentum was used to facilitate mixing with the hot primary gases. The air was admitted through only one wall of the combustor liner except for approximately 5 percent that was used to cool the inner combustor surfaces. By integrating the inlet and outlet diffuser design with the combustion chamber, an overall reduction in length of 30 percent was obtained over conventional configurations. A rectangular segment of this combustor was tested with vaporized propane fuel.

Annular Flow

A Coaxial Flow Reactor - A Gaseous Nuclear-Rocket Concept

Aspects of a new gaseous nuclear-rocket concept are considered. The principle of this type of cavity reactor is one of maintaining the separation of two coaxial streams - fuel within propellant - rather than attaining the separation of fuel propellant gases within the cavity. An acceptably low uranium consumption rate is possible if the fuel stream can be maintained at an axial velocity which is 1/100 to 1/1000 of the propellant velocity. An elementary hydrodynamic analysis for laminar incompressible flow indicates that the average uranium core velocity may only reach 2 to 11 times the initial core velocity for a typical reactor. The results of a 1-D criticality analysis for a D2O/(235)U system show that the effect of shrinking the fuel region within the reactor cavity is not serious; the effects of moderator heating and structural materials on critical mass are also shown. Overall rocket performance calculations are made for reasonable operating conditions; these results indicate that thrusts from 25,000 to 50,000 pounds and accelerations from 10(exp -1) to 3 g are possible.

Herbert Weinstein

Numerical Modeling of the Transient Chilldown Process of a Cryogenic Propellant Transfer Line

Before cryogenic fuel depots can be fully realized, efficient methods with which to chill down the spacecraft transfer line and receiver tank are required. This paper presents numerical modeling of the chilldown of a liquid hydrogen tank-to-tank propellant transfer line using the Generalized Fluid System Simulation Program (GFSSP). To compare with data from recently concluded turbulent LH2 chill down experiments, seven different cases were run across a range of inlet liquid temperatures and mass flow rates. Both trickle and pulse chill down methods were simulated. The GFSSP model qualitatively matches external skin mounted temperature readings, but large differences are shown between measured and predicted internal stream temperatures. Discrepancies are attributed to the simplified model correlation used to compute two-phase flow boiling heat transfer. Flow visualization from testing shows that the initial bottoming out of skin mounted sensors corresponds to annular flow, but that considerable time is required for the stream sensor to achieve steady state as the system moves through annular, churn, and bubbly flow. The GFSSP model does adequately well in tracking trends in the data but further work is needed to refine the two-phase flow modeling to better match observed test data.

Temperature Sensors

The 60-MW Shuttle Interaction Heating Facility

An arc-heated wind-tunnel system described in the present paper will simulate aerodynamic heating in large-scale tests of the thermal protection system of the Shuttle Orbiter Vehicle during entry. The system provides for large-scale subsystem tests in high-enthalpy streams with boundary layer flows at high Reynolds numbers and for large test-body sizes in stagnation flows. The discussion covers the design concept of the arc-jet systems, the extensive hardware developments of the arc heater to provide reliable operation, and verification and performance measurements of the system's operating envelopes.

W Winovich

Ejecta Management in a Safe Lithium Ion Battery Design

As lithium-ion battery energy densities continue to rise, managing the heat and pressure generated during failure events has become increasingly critical. Safety systems must effectively relieve pressure without releasing sparks, flames, or particulate matter, requiring robust filtration solutions. The challenge is compounded by the reduced free volume available for gas expansion in high-density designs, which increases the demands on these filters. While significant progress has been made through experimental studies and modeling efforts to understand the behavior of ejecta during battery failures, there remains a pressing need for practical, rule-of-thumb sizing parameters. These parameters would help correlate high-energy waste streams with appropriate filter design, ensuring reliable containment and safety. This talk will explore recent experimental findings in this area and discuss the potential pathways for developing these essential sizing guidelines.

Ejecta Management

Single-Drop Reactive Extraction/Extractive Reaction with Forced Convective Diffusion and Interphase Mass Transfer

An algorithm has been developed for the forced convective diffusion-reaction problem for convection inside and outside a droplet by a recirculating flow field hydrodynamically coupled at the droplet interface with an external flow field that at infinity becomes a uniform streaming flow. The concentration field inside the droplet is likewise coupled with that outside by boundary conditions at the interface. A chemical reaction can take place either inside or outside the droplet or reactions can take place in both phases. The algorithm has been implemented and results are shown here for the case of no reaction and for the case of an external first order reaction, both for unsteady behavior. For pure interphase mass transfer, concentration isocontours, local and average Sherwood numbers, and average droplet concentrations have been obtained as a function of the physical properties and external flow field. For mass transfer enhanced by an external reaction, in addition to the above forms of results, we present the enhancement factor, with the results now also depending upon the (dimensionless) rate of reaction.

Leonid S Kleinman

Single-Drop Reactive Extraction/Extractive Reaction With Forced Convective Diffusion and Interphase Mass Transfer

An algorithm has been developed for time-dependent forced convective diffusion-reaction having convection by a recirculating flow field within the drop that is hydrodynamically coupled at the interface with a convective external flow field that at infinity becomes a uniform free-streaming flow. The concentration field inside the droplet is likewise coupled with that outside by boundary conditions at the interface. A chemical reaction can take place either inside or outside the droplet, or reactions can take place in both phases. The algorithm has been implemented, and for comparison results are shown here for the case of no reaction in either phase and for the case of an external first order reaction, both for unsteady behavior. For pure interphase mass transfer, concentration isocontours, local and average Sherwood numbers, and average droplet concentrations have been obtained as a function of the physical properties and external flow field. For mass transfer enhanced by an external reaction, in addition to the above forms of results, we present the enhancement factor, with the results now also depending upon the (dimensionless) rate of reaction.

Leonid S Kleinman

Computation of three-dimensional mixed convective boundary layer flow

The paper presents the numerical solution of heat and mass transfer during cross-flow (orthogonal) mixed convection. In this class of flow, a buoyancy-driven transport in the vertical direction and a forced convective flow in the horizontal direction results in a three-dimensional boundary layer structure adjacent to the plate. The rates of heat and mass transfer are determined by a combined influence of the two transport processes. The equations for the conservation of mass, momentum, energy, and species concentration were solved along with appropriate boundary conditions to determine the distributions of velocity components, temperature, and concentration across the thickness of the boundary layer at different locations on the plate. Results were expressed in dimensionless form using Reynolds number, Richardson number for heat transfer, Richardson number for mass transfer, Prandtl number, and Schmidt number as parameters. It was found that the transport is dominated by buoyancy at smaller vertical locations and at larger distances away from the forced convection leading edge. Effects of forced convection appeared to be very strong at smaller horizontal distances from the leading edge. The cross stream forced convection enhanced the rate of heat and mass transfer by a very significant amount.

Prashandt Gadepalli

Test Data Analysis of the Thermodynamic Vent System-Augmented Top Spray Injector Liquid Nitrogen Transfer Experiments

Traditionally, a cryogenic tank must be pre-chilled to some “target” temperature before the main vent valve can be closed to attempt a non-vented fill (NVF) of cryogenic liquid propellant. This methodology is particularly attractive for performing in-space transfer of cryogens due to the unknown location of the liquid/vapor interface in microgravity and the high likelihood of venting liquid if the vent valve is opened during transfer. This paper presents in-depth test data analysis of a Thermodynamic Vent System (TVS) augmented injector used for cryogenic tank chilldown and fill experiments of a thin-walled Titanium tank. Eight tests were conducted using liquid nitrogen across a range of inlet conditions and boundary conditions, and three different chilldown/fill methods. For four of the tests, the injector sprays liquid into the tank as normal, but also uses a TVS heat exchanger to cool the metallic injector itself as well as the main incoming liquid stream. Results show that using the TVS augmented injector simplifies transfer operation via enhanced condensation at the injector surface at the cost of sacrificing only a small amount of propellant.

Thermodynamic Vent System

The Trash Compaction Processing Systems (TCPS) Ground Unit Control Sample Testing

The Trash Compaction Processing System (TCPS) is being developed by NASA and Sierra Space to process crew trash for long-duration missions. The system compacts and thermally processes mixed spacecraft waste to reduce volume and stabilize the material while managing gas and liquid effluents. A Ground Unit (GU) located at Sierra Space in Madison, Wisconsin was used to run a series of tests using standardized control samples representing different trash conditions, including nominal, high liquid, high cloth, benign, and foam. Gas grab samples were collected during processing and analyzed to identify the compounds present in the effluent stream and compare the concentrations to the NASA spacecraft maximum allowable concentrations (SMACs). Additional testing included odor testing at White Sands Test Facility, aerosol measurements, microbiology, and tile characterization. Overall, the compounds detected in the gas samples were well below the SMAC limits for all trash models tested. The results from this testing are being used to help guide the verification approach and test planning for the TCPS Flight Unit that is planned for on-orbit testing on the International Space Station.

Control Samples

CFD-Assisted Nodal Modeling of Sloshing in a Cryogenic Propellant Tank

During autogenous pressurization, tank sloshing causes a significant increase in pressurant consumption to maintain constant ullage pressure during draining of the tank. This increase in pressurant consumption is caused by a significant increase in condensation at the liquid-vapor interface. Sloshing strongly affects the liquid side heat transfer coefficient and thereby the condensation rate. Traditionally, sloshing is modeled by CFD code using the VOF (Volume of Fluid) method to track the liquid vapor interface during sloshing. CFD calculations require a very fine grid to accurately compute the heat and mass transfer at the interface. Therefore, computations are time consuming and prohibit performing many parametric studies often needed during the design of a new system. This paper describes an alternative approach by developing a CFD-assisted nodal model to predict system parameters more economically with reasonable accuracy. In this approach, a multi-node model of tank pressurization was developed using GFSSP. A multi-node model was needed to account for stratification. The model computes heat and mass transfer at the interface to calculate the condensation rate. The liquid side heat transfer is computed using the parameters of sloshing dynamics such as frequency, wave amplitude, and interface area. The parameters of sloshing dynamics are computed by the CFD code LOCI-Stream. The model predictions were compared with test data for several cases.

Cryogenic Tank Sloshing

Proactive Wildfire Management: A Remote Sensing and Multimodal CNN-MLP Architecture for Ignition Risk Forecasting

As the frequency and intensity of wildfires increase, with fire seasons now starting earlier and ending later than they have over the past decades, current monitoring systems, such as lookout towers and satellites, are hindered by cloud cover, low-resolution imagery, and static data gaps that fail to track vegetation moisture levels fast enough to catch rapid pre-ignition changes. This report proposes a Machine Learning-enabled Wildfire Ignition Prediction framework that combines satellite monitoring with dynamic and high-resolution remote sensing from Unmanned Aerial Vehicle (UAV) swarms. The method would use multispectral and thermal data from the Landsat program to create a baseline for vegetation health, calculating a two-band Enhanced Vegetation Index (EVI2) and the moisture content of the vegetation. These inputs will later be fused with microscale UAV weather data, including thermal hotspots found through thick canopies, hyperspectral chemical signatures of pre-visual combustion, and local weather streams. The multispectral satellite, multispectral Light Detection and Ranging (LiDAR), and thermal data would then be processed through a Convolutional Neural Network (CNN), alongside a Multilayer Perceptron (MLP) for the micro-weather telemetry. The outputs of these networks would be fused into a single feature representation and passed through a final prediction network to generate real-time ignition risk scores and hotspot alerts. Model performance would be assessed using standard classification metrics, including a Receiver Operating Characteristic - Area Under the Curve (ROC AUC) and F1 score. This system would allow first responders to identify high-risk zones and intervene before ignition occurs, improving emergency response time compared to current approaches.

machine learning

Evaluation of Low-Energy Hydrogen Separation Method Using Metal-Organic Frameworks (MOFs) for Closed-Loop ECLSS Air Revitalization (CLEAR)

The State-of-the-Art (SOA) air revitalization architecture onboard the International Space Station (ISS) recovered approximately 50% of the oxygen (O 2 ) from metabolic carbon dioxide (CO 2 ) via the Sabatier process from 2011 to 2017. O 2 recovery is currently constrained by the limited availability of reactant hydrogen (H 2 ) preventing complete conversion of CO 2 to H 2 O. Increasing O 2 recovery within Closed-Loop ECLSS is essential to reducing resupply mass for long-duration manned missions; specifically focusing on water (H 2 O) which supplies H 2 for Sabatier via water electrolysis. Past ground test endeavors at Marshall Space Flight Center (MSFC) have attempted to recover H 2 from Sabatier-produced CH 4 using technologies such as carbon vapor deposition (CVD) and plasma pyrolysis. The byproducts of these technologies can act as a catalyst poison or reactor deadload to the Sabatier reactor. Hydrogen separation techniques must be utilized to maintain the Sabatier catalyst during gas recycling and must be scalable, non-energy intensive, and safe to operate in a habitation setting. Research indicated that metal-organic frameworks (MOFs) could meet these criteria and were tested for their capability to capture the various carbon-based gaseous products of CVD and plasma pyrolysis such as acetylene (C 2 H 2 ), ethylene (C 2 H 4 ), ethane (C 2 H 6 ), and carbon monoxide (CO) which would purify the hydrogen gas stream passing through the MOF. A sub-scale adsorption column was developed by Marshall Space Flight Center to test three MOF candidates against a synthetic gas mixture comprised of process-relevant carbonous gases and hydrogen to evaluate the separation capability of the MOFs. The results of the hydrogen separation capability, isothermal desorption capability, and demonstrated cyclic reuse of the MOF are presented in this paper.

Kagen Crawford

Evaluation of Long-Term Storage Stability and Operational Efficiency of Rapid Cycle Amine Adsorbents

With the recent incorporation of Mars Extravehicular Activity (EVA) into the 2025 NASA roadmap, Rapid Cycle Amine (RCA) technology advancement within the Exploration Extravehicular Mobility Unit (xEMU) applies to both the upcoming Lunar Artemis missions and future human exploration of Mars. The incorporation of commercial spacesuit vendors to service NASA’s crewed-space programs since 2021 has increased the demand for regenerable, RCA-based carbon dioxide (CO2) and humidity control adsorbents. The regenerable RCA subunit is the most advanced, long-term solution for CO2 removal and humidity control, enabling both lunar and Martian EVAs. The adsorbent selected for use within the RCA unit must exhibit sufficient storage stability and operational efficiency for prolonged missions. As XploSafe worked to simultaneously develop both a recirculating sub-atmospheric test rig and adsorbents for the RCA system within the xEMU, several novel adsorbents were evaluated for long-term storage stability in support of future extended-duration missions. The chosen materials were periodically evaluated by nuclear magnetic resonance (NMR) spectroscopy, thermal desorption-coupled with gas chromatography/mass spectrometry (TD-GC/MS), and CO2 adsorption to assess long-term storage efficacy across various environmental storage conditions. NMR spectroscopy was utilized by extracting the active CO2 adsorbing chemical from the solid support with deuterated solvent and comparing the spectra over time for degradation and change. The solid adsorbents were also analyzed via TD-GC/MS to reveal any potential off-gassing chemicals over time. Additionally, XploSafe’s breakthrough test rig was utilized to dose the solid adsorbents with a 585 BTU/h metabolic rate flow-equivalent CO2 stream and monitored for 0–99% CO2 breakthrough. The performance metrics from the breakthrough analysis were compared over the storage study duration for CO2 removal and humidity control. Xplo-SA9T was evaluated for 24 months, whereas two additional adsorbent variants, MMPA-Sorbent and LPEI-Sorbent, were each evaluated for 12 months.

John R Tidwell

On the isotopic signature of recent solar-wind nitrogen

One of the most intriguing discoveries yielded by the Apollo samples was evidence pointing towards a significant long-term change in the composition of the sun. Such a change, of the size inferred from the lunar sample data, is inconsistent with present theories of solar evolution. Consequently, there is much interest in exploring this phenomenon as closely as possible, to determine exactly what compositional changes have taken place and whether those changes really did take place in the sun, or whether the cause lies elsewhere. The reason why we can use the moon to analyze the elements in the sun is that the sun emits a stream of ions, known as the solar wind, whose composition, on average, is believed to be the same as that in the surface regions of the sun. When the solar-wind ions hit the surface of the moon, many of them penetrate a short distance into the dust grains lying on the lunar surface. Thus, after a grain has sat on the lunar surface for a while, it has a rim of material that is partly lunar and partly solar in composition. For most chemical elements, the difference between lunar and solar composition is so sufficiently small that the solar elements cannot be detected, but for a handful of elements that are missing from the moon, their solar 'signature' can be observed in samples of lunar soil brought back by the astronauts. Among those elements is nitrogen, the most common element in the air we breathe, but very rare indeed on the moon. Our analytical techniques are not sophisticated enough yet to enable us to analyze individual lunar soil grains for nitrogen, much less to zero in on just the nitrogen in the surface of such a grain. Consequently we are forced to analyze samples consisting of many different grains, each of which could have experienced its own individual history. This makes it difficult to identify the nitrogen implanted in grain surfaces, and also to define the age of a sample.

Kim, Y.