Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Penetrator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cloud-based Testbed for Adaptive Under-Frequency Load Shedding with High DER Penetration

Increasing penetration of distributed energy resources and behind-the-meter renewables may soon disrupt the efficacy of critical protection schemes, such as under-frequency load shedding (UFLS). Improved data exchange and coordination across the transmission-distribution boundary will be required to maintain reliability of bulk electric system. Standards-based data integration platforms using agreed-upon semantic vocabularies, such as the Common Information Model, will be key to enabling adaptive protection schemes requiring synthesized data from both the bulk power system and behind-the-meter resources. This paper introduces a cloud-based open-source data integration environment and UFLS clustering algorithm being developed to enable adaptive relay coordination between transmission and distribution utilities in the state of Vermont.

Anderson, Alexander A.

On how avalanches penetrate the SOL and broaden heat loads

Recent experiments reported a correlation between power law core temperature spectra and Dα emission, suggesting that heat avalanches penetrate the SOL. This paper derives a threshold criterion for avalanche penetration using a reduced model. Avalanches with ($\bigtriangledown$$\tilde{T}$) rms > $\bigtriangledown$$\tilde{T}$ crit at the separatrix are predicted to penetrate, and so broaden the SOL and heat load distribution. $\bigtriangledown$$\tilde{T}$ crit is ~ 1/$τ$ ∥ , where $τ$ ∥ is the parallel heat flow time through the SOL. Penetration occurs when avalanches are strong enough to steepen sufficiently to shock at the separatrix. A positive correlation is found between the nonlinear drive for steepening and the penetration depth. In particular, penetration depth exceeds that of the heuristic drift limit when shocks form. Implications for numerical and physical experiments are also discussed.

SOL heat load

Precise Linker Length and Dynamic Bond Exchange Control Penetrant Diffusion in Dense Vitrimers

Polymer networks with dynamic covalent bonds have been investigated for their self-healing ability, recyclability, and potential as more sustainable materials. Recent results have indicated that in some cases, bond exchange can enhance the transport of penetrants in dense networks, pointing to their potential for separations of membranes. Here, imine dynamic bonds in ethylene oxide (EO) networks with precise linker lengths were synthesized to investigate the transport of N,N′-bis(2,5-di-tert-butylphenyl)-3,4,9,10-perylenedicarboximide (BTBP), a large, anisotropic dye molecule. Networks with mesh sizes smaller than, comparable to, and greater than the size of the penetrant axes were investigated to probe the effects of bond exchange and network confinement on transport. Mesh sizes, which ranged from 0.5 to 1.62 nm, were determined from shear rheology, glass transitions by calorimetry, and probe diffusion coefficients by fluorescence recovery after photobleaching. Permanent networks with identical EO chain lengths were prepared as control samples, and up to a 3 orders of magnitude increase in diffusion coefficient is observed in the dynamic systems for short linkers containing 13 backbone atoms. The longest linkers with 71 backbone atoms show no difference between the permanent and dynamic networks. Linkers shorter than 11 backbone atoms, corresponding to a mesh size smaller than the penetrant small axis, diffusion is no longer observable on the experimental time scale, indicating a sharp cutoff attributed to the precise linkers and narrow mesh size distribution. The dynamic imine exchange time scales were compared to the diffusive hopping times of penetrants and indicate that exchange can occur during a diffusive displacement. Furthermore, these findings provide insights into the factors affecting penetrant transport in dense polymers and inspire the development of next-generation selective polymer membranes.

Diffusion

Mechanism of ion pairing–induced co-ion penetration into the stern layer

In classical electric double layer (EDL) theory, co-ions—ions carrying the same charge as the electrode—are assumed to be excluded from the Stern layer because of electrostatic repulsion. However, ion pairing with adsorbed counterions may enable co-ions to access the EDL, a phenomenon that remains underexplored. Key questions therefore remain unresolved, including how deeply co-ions penetrate, how ion-specific properties govern them, and how ion pairing within the EDL differs from bulk solution. Here, in this study, we employ molecular dynamics simulations combined with well-tempered metadynamics to quantify co-ion penetration and ion-pairing thermodynamics at positively charged Mg-Al layered double hydroxide interfaces (σ = +20.6 μC/cm 2 ) in aqueous chloride electrolytes across 0.005–3 M range. We reveal a concentration-driven crossover: at dilute conditions, counterion–co-ion contact ion pairing (CIP) is thermodynamically unfavorable or only weakly favorable (ΔG CIP = +0.12 kcal/mol for Li + to −0.42 kcal/mol for K + ), leading to co-ion exclusion. As concentration increases (≥0.5 M), enhanced screening reduces surface repulsion and stabilizes CIP thermodynamics (ΔG CIP = −0.89 kcal/mol for Li + to −1.05 kcal/mol for K + at 3 M), enabling monovalent co-ions to penetrate the Stern layer following the hydration hierarchy K + > Na + > Li + , while divalent co-ions (Mg 2+ , Ca 2+ ) remain in the diffuse layer, forming only solvent-separated pairs. Comparison with bulk solution shows interfacial ion pairing is suppressed at low concentrations but converges to bulk-like thermodynamics at high concentrations, indicating surface effects vanish under strong screening. These results establish a quantitative framework linking ion-pairing thermodynamics to co-ion penetration and providing strategies to design electrochemical interfaces.

Co-ion penetration

A mechanistic, multiscale model for predicting Pd penetration in TRISO fuels using BISON

TRistructural ISOtropic (TRISO) particles use silicon carbide (SiC) as the primary structural member and barrier against metallic fission product (FP) release. palladiums (PDs), produced by fission in the fuel kernel, can diffuse to and chemically interact with the SiC layer, degrading its structural integrity and ability to contain radioactive FPs. Existing temperature-dependent correlations for predicting Pd penetration rely on experimental data with significant scatter due to varying conditions, potentially complicating ongoing fuel qualification and licensing efforts for advanced reactors that would subject TRISO fuels to operating conditions outside of those examined in the experiments. A mechanistic model of Pd production, transport, and reaction is developed in this work to better understand and predict PD attack of SiC in TRISO particles. molecular dynamicss (MDs) simulations are utilized to calculate the Pd diffusivity in SiC grain bulk and grain boundaries. A mesoscale phase-field diffusion model, informed by the MD diffusivities, is used to develop a reduced order model (ROM) for the effect of SiC microstructure on the Pd penetration rate. The engineering scale BISON model calculates Pd production and transport, utilizing the ROM to predict penetration rates consistent with experimental data. This novel mechanistic ROM captures the effect of temperature, microstructure, and irradiation history on Pd penetration. In conclusion, these new capabilities are expected to support ongoing qualification and licensing efforts associated with near-term TRISO-fueled reactor applications.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY

Modeling Sepsis: Establishment and Validation of a 72-Hour Swine Model of Penetrating Abdominal Trauma

Background/Objectives: Fecal peritonitis following penetrating abdominal trauma is a serious condition that often results in sepsis and organ failure. The aim of our study was to develop a novel conscious porcine model of sepsis and organ dysfunction caused by multiple penetrating injuries to the small and large intestines. Methods: Twelve female Yorkshire pigs (average weight 50.6 ± 6.5 kg) were divided into two groups: Penetrating Abdominal Trauma (PAT) (n = 8) and Control (n = 4). All surgical procedures were performed under anesthesia with adequate analgesia. In the PAT group, the small and large intestines were punctured, and feces mixed with saline were introduced into the abdominal cavity to induce peritonitis. The Control group received sham surgery with only saline solution. The animals were observed in a conscious state over a period of 72 h, vital parameters were recorded, and blood samples were taken regularly. We adapted a pig-specific SOFA score and developed pig-specific SIRS criteria and NEWS2 score to assess organ function. The model was validated by independent investigators. Results: The survival rate in the PAT group was 75%, with an average survival time of 58.5 h, while all animals in the Control group survived to euthanasia. Monitoring showed pathophysiological changes, such as tachycardia, leucopenia, and thrombocytopenia, indicative of sepsis and organ dysfunction. Blinded investigators independently confirmed the model’s validity. Conclusions: A new swine model of penetrating abdominal trauma and sepsis has been successfully developed that demonstrates significant physiological and immunologic changes comparable to human sepsis. This new model provides a realistic platform for future research into sepsis, its diagnostics, and the evaluation of therapeutic strategies.

General & Internal Medicine

Utility Perspective on Protection Challenges with High IBR Penetration [Slides]

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY

Pursuing small-scale measures of penetration resistance in Ti-5553 alloy

This work was originally proposed to illustrate the performance of a particular set of differently processed Ti-5553 plates under dynamic threats. It became clear that the larger question, at present, is whether the small-scale shaped charge design of an RP-4 detonator can be employed to efficiently explore the dynamic penetration resistance of representative test articles. The initial penetration testing that employed three variants of thermomechanical processing of Ti-5553 plates appeared to demonstrate that there was a noticeable difference in their performance. The remaining pertinent question was regarding the variation in the shaped charge performance and how it compares to the variation from the three titanium plate tests. Based on the limited testing presented here the RP-4 shaped charge detonator appears to have an average depth of penetration in 6061 aluminum of 90mm with a 1.5CD stand off.

shaped charge penetration

Symmetry structure of a Riccati equation appearing in penetration mechanics

In the design of projectile penetration experiments a matter of considerable interest is scaling: that is, the potential relevance of small-scale experiments to their full-scale counterparts, in a manner analogous to that most often encountered in the context of fluid mechanics. From the theoretical standpoint, phenomena associated with scaling and scalability can be assessed using the well-established tools of dimensional analysis and the Buckingham-Pi Theorem. However, the familiar precepts of dimensional analysis are themselves a specific manifestation of the broader group invariance properties or symmetries of a mathematical model. Here, this work explores these notions – that is, dimensional analysis, the conditions for realizing complete similarity, and any additional symmetry structures – in the context of a Riccati differential equation appearing in the context of penetration mechanics. The aim of the investigation is twofold: 1) to complement existing empirical considerations with a concrete theoretical basis, and 2) to provide a deeper theoretical understanding of the projectile penetration model and its many implications.

97 MATHEMATICS AND COMPUTING

Impact of Penetrating Kelvin Waves on MJO Rainfall Propagation Through Deep Convection Modulation

The Madden‐Julian Oscillation (MJO) is a dominant intraseasonal oscillation in the tropics. As MJOs propagate over the Indian Ocean, some of them can be penetrated by fast‐moving equatorial Kelvin waves originating to the west of the MJOs. Through a series of sensitivity experiments, we demonstrate that these penetrating Kelvin waves can modulate the eastward propagation speed of MJO rainfall. Deep convection in the western MJO rainfall envelope initiates more frequently and produces greater lifetime rainfall when a convectively active Kelvin phase is present, while the opposite occurs during a convectively suppressed Kelvin phase. This alteration in deep convection activity can lead to notable changes in the propagation of the large‐scale MJO rainfall envelope. The modulation of deep convection lifetime rainfall by penetrating Kelvin waves primarily occurs through their impact on deep convection rainfall area, which is closely related to the variations in lower‐tropospheric moisture induced by the Kelvin waves.

Chen, Xingchao [Pennsylvania State Univ., Universi

A scaling law of the neutral penetration length and Balmer- α wing shape in high-temperature plasmas

Hydrogen atoms penetrating deep inside high-temperature magnetically confined plasmas by repetitive charge-exchange collisions result in a particle source of the plasma, which affects the plasma transport significantly. In this paper, we present an approximate solution of the fluid equations for neutral transport and an analytical representation of the neutral penetration length, in a simplified plasma geometry. This analysis predicts a power-law decay in the Balmer-α line wings which reflects the velocity distribution of the neutral atoms, with the power-law exponent analytically represented as well. These scaling laws are compared with a simple Monte–Carlo simulation and spectroscopic observations of Large Helical Device plasmas. Since the Balmer-α line wings are experimentally accessible, our formulation opens the possibility to quickly estimate the neutral penetration length from spectroscopic observations.

neutral opacity

Clustering Interval Load with Weather to Create Scenarios of Behind-the-Meter Solar Penetration

Forecasting load at the feeder level has become increasingly challenging with the penetration of behind-the-meter solar, as this self-generation is only visible to the utility as aggregated net-load. This work proposes a methodology for creation of scenarios of solar penetration at the feeder level for use by forecasters to test the robustness of their algorithm to progressively higher penetrations of solar. The algorithm draws on publicly available observations of weather condition (e.g., rainy/cloudy/fair) for use as proxies to sky clearness. These observations are used to mask and weight the interval deviations of similar native usage profiles from which average interval usage is calculated and subsequently added to interval net generation to reconstruct interval total generation. This approach improves the estimate of annual energy generation by 23%; where the net generation signal currently reflects 52% of total annual gener- ation, now 75% is captured. This methodology for creation of forecast testing scenarios is data driven and extensible to service territories which lack information on irradiance measurements and geocoordinates.

solar, load

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY

SMR Containment Cable and Electrical Penetration Assembly System

GAIN Project CRADA Number NFE-21-08839, entitled “SMR Containment Cable and EPA System” was initiated by the partnership of Oak Ridge National Laboratory (ORNL) and Engineered Solutions Group (ESG) to test an ESG-designed Electrical Penetration Assembly and Containment Cabling System Qualified for not only SMR technologies, but also Advanced Reactors design. An Electrical Penetration Assembly (EPA) is a component used to allow electrical power and signal conductors as well as optical fiber through the nuclear reactor’s containment structure while maintaining a pressure barrier. The EPA ensures the containment's integrity both during the normal operation and also accident conditions by providing a sealed passage for power and signals. This project was undertaken to fill the equipment gap of EPA and Cabling Systems that require much more severe environmental requirements than legacy plant applications present due to their smaller containment volumes that result in high energy densities compared to legacy designs. This high energy density results in severe accident environments and also more severe normal operating conditions.This document describes cost effective approaches to qualify a unique EPA for Small Modular Reactor (SMR) technologies as legacy LWR EPA technologies will likely have inherent material performance insufficiencies. The DBA profiles for SMRs (and some Advanced Reactor Technologies) are more severe than the legacy qualification requirements making the design of the qualification testing system challenging as the temperatures and pressures can approach the limits permitted by ASME Pressure Vessel Code, as well as accident temperatures exceeding the capability of polymeric gaskets and dielectrics. Small Modular Reactors are designed to have, as the name suggests, modularity which implies sized for factory fabrication and subsequent assembly at the power plant site. SMR containment is much smaller than a legacy Light Water Reactor containment. The containment walls are likely to be comprised of stainless steel. Qualifying Electrical Penetration Assemblies (EPAs) through these steel vessels are of interest in this work. Methods are presented here that discuss critical safety and cost effectiveness for these SMR EPA’s test systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Engineered Solutions Group's SMR Containment Cable and Electrical Penetration Assembly System

GAIN Project CRADA Number NFE-21-08839, entitled “SMR Containment Cable and EPA System” was initiated by the partnership of Oak Ridge National Laboratory (ORNL) and Engineered Solutions Group (ESG) to test an ESG-designed Electrical Penetration Assembly and Containment Cabling System Qualified for not only legacy LWR designs, but also Small Modular Reactors designs currently being designed by several different suppliers. This project was undertaken to fill the equipment gap of EPA and Cabling Systems that require much more severe environmental requirements than legacy plant applications present due to their smaller containment volumes that result in high energy densities compared to legacy designs. This high energy density results in severe accident environments and more severe normal operating conditions as well. We developed two approaches to qualify Electrical Penetration Assembly (EPA) and Containment Cabling Systems for SMRs and Advanced Reactors. We take into consideration the more severe environmental parameters found with SMR designs. The system will need to meet a qualification test program addressing wear/cyclic aging, potential radiation exposure, thermal aging, vibration aging, thermal cycling, seismic qualification, electrical fault testing (per IEEE 317) and accident simulation. The equipment must meet the requirements of 10CFR50.49, GDC 50 in 10CFR50 Appendix A, and 10CFR50 Appendix J. NRC Regulatory Guides (RGs) identify an acceptable way of meeting regulatory requirements. RGs frequently endorse a standard for meeting these requirements. Specific to this review, equipment would be qualified in accordance with the following IEEE Standards. • IEEE 317-2013 (Electrical Penetration Assemblies), which is endorsed by RG 1.63, Rev. 3, • IEEE 323-2003 and the more current IEC/IEEE 60780-323 (Environmental Qualification of 1E Equipment) which is endorsed by RG 1.89. IEEE 323-2003 is endorsed by RG 1.209, • IEEE 344-2020 (Seismic Qualification. The 2013 version endorsed by RG 1.100, Rev. 4, with exceptions), • IEEE 383-2015 (Electrical Cables) (which is endorsed by RG 1.189 Rev. 4 and the -2003 version endorsed by RG 1.211 rev. 0), • IEEE 572-2019 (Electrical Connectors and Assemblies), which is endorsed by 1.156 Rev 1, and • [IEEE 1202 (endorsed by RG 1.189) would normally be applicable but the advanced cable designs are impervious to this cable flame test.] The primary goal of such a program is to provide an EPA design that can meet the qualification requirements for all legacy light water reactor plants currently operating as well as new plant designs including light water Small Modular Reactors. Thus, these requirements are applicable to plants licensed under 10CFR50 and 10CFR52. Other reactor designs may be evaluated, and this test system and qualification method applied to those applications if the requirements would satisfy the requirements of the intended plant. A secondary benefit of this work is to document some of the history and background in these requirements as there have been recent delays in an SMR licensing process due to NRC Requests for Additional Information in this subject matter area.

42 ENGINEERING