Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pellicles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Dye laser tuning with pellicles.

Thin nitrocellulose membranes (pellicles) are shown to exhibit properties which make them suitable for intracavity tuning elements in high-energy pulsed dye lasers. Uncoated pellicles of 2-micron and 8-micron thickness with surface figures of lambda/1 are shown to closely approximate the properties of low-finesse etalons with wide free spectral ranges. Pellicles of 8-micron thickness, coated on both surfaces with 50% reflectivity multilayer dielectrics, are shown to be effective as spectral narrowing elements with peak transmission greater than 80% and resultant laser linewidths of 0.57 nm full width at half-maximum.

Mumola, P. B.↗

Imaging Fluid Flow

Electro-optical system allows simultaneous viewing of schlieren, shadowgraph and interferometric images of volume of fluid under test. In imaging system cube beam splitters replaced by plate-type beam splitters or pellicle beam splitters.

Witherow, W. K.↗

Optical Mounts for Cryogenic Beam Splitters

Spring-loaded optical mounts maintain flatness and alinement of rigid, framed, or pellicle beam splitters over wide temperature range, despite differences in thermal expansion amoung materials. Mounts permit optical adjustments at ambient temperature even though optical system operated subsequently within few degrees of absolute zero. Mounts useful as holders for integrated-circuit master patterns, survey targets, vibrating membranes, noise- or pressure-sensing membranes, osmosis filters, and fuel-cell elements.

Rudman, A. A.↗

A device for applying plastic film antireflection coatings to optical elements

To simplify the process of thermally bonding thin plastic films to optical elements and to help eliminate the source of the flaws, a film-application device (FAD) is developed. Any plastic film may be used to make the coatings, but thin polyethylene is particularly useful for this application since it is readily available. If more than one layer of polyethylene is required, several layers may be applied, one layer at a time. The coatings may be used for protecting optical elements or to reduce surface reflection of radiation with wavelengths greater than 20 microns. When the FAD is used without the central plate it may be used to stretch single sheets of plastic material to make pellicles or beam-splitters for many applications.

Augason, G. C.↗

Device Applies Films to Optical Elements

Clamping device applies protective or antireflective dielectric coating to lenses or other optical elements. Alternative version of device applies thin sheet of dielectric film to ring or stretches it for clamping in holder to form pellicle or beam splitter. Defects avoided by new apparatus, which uniformly stretches dielectric films in radial direction and creates vacuum between them before thermally bonded to optical element.

Augason, Gordon C.↗

Method and apparatus for making an optical element having a dielectric film

A film-application device (FAD) comprising a pair of exterior, tapered, O-ring bearing plate members and a central plate member for simplifying the process of thermally bonding a thin dielectric film to a substrate comprising an optical element are discussed. In use, the film is sandwiched between the O rings and stretched across the optical element by squeezing the exterior plates together before bonding to the element. The film may be used for protecting the optical element or to reduce surface reflection of radiation. The FAD may also be used without the center plate to stretch a dielectric film prior to its attachment to or insertion in a holder to make pellicles or beam-splitters.

Augason, Gordon C.↗

Spectrogoniometer for measuring planetary surface materials at small phase angles

This paper describes an instrument, termed spectrogoniometer, which was designed to measure the bidirectional reflectance properties of planetary surface analogs at very small phase angles. By using a pellicle beam splitter, a highly collimated laser light source, and a carefully aligned apparatus it was possible to measure the reflectance properties of geologic samples under any viewing geometry: the angles of incidence and emission ranging from 0 to 90 deg, and the azimuthal angle ranging from 0 to 360 deg. The results on the effect of porosity are demonstrated by comparing measurements on a compact sample (with a void space of 25 percent) and a fluffy sample (with a void space of 90 percent). The fluffy sample exhibited a 30-percent increase in intensity between 10 and 0 deg, whereas the compact sample exhibited only a 20-percent increase.

Buratti, Bonnie J.↗

Evaluation of an Anaerobic Digestion System for Processing CELSS Crop Residues for Resource Recovery

Three bioreactors, connected in series, were used to process CELSS potato residues for recovery of resources. The first stage was an anaerobic digestor (8 L working volume; cow rumen contents inoculum; fed-batch; 8 day retention time; feed rate 25 gdw/day) that converted 33% of feed (dry weight loss) to CO2 and "volatile fatty acids" (vfa, 83:8:8 mmolar ratio acetic:propionic:butyric). High nitrate-N in the potato residue feed was absent in the anaerobic effluent, with a high portion converted to NH4(+)-N and the remainder unaccounted and probably lost to denitrification and NH4(+) volatilization. Liquid anaerobic effluent was fed to an aerobic, yeast biomass production vessel (2 L volume; Candida ingens inoculum; batch [pellicle] growth; 2 day retention time) where the VFAs and some NH4(+)-N were converted into yeast biomass. Yeast yields accounted for up to 8% of potato residue fed into the anaerobic bioreactor. The third bioreactor (0.5 L liquid working volume; commercial nitrifier inoculum; packed-bed biofilm; continuous yeast effluent feed; recirculating; constant volume; 2 day hydraulic retention time) was used to convert successfully the remaining NH4(+)-N into nitrate-N (preferred form of N for CELSS crop production) and to remove the remaining degradable soluble organic carbon. Effluents from the last two stages were used for partial replenishment of minerals for hydroponic potato production.

Strayer, R. F.↗

Remote Measurement of Atmospheric Temperatures By Raman Lidar

The Raman shifted return of a lidar, or optical radar, system has been utilized to make atmospheric temperature measurements. These measurements were made along a horizontal path at temperatures between -20 C and +30 C and at ranges of about 100 meters. The temperature data were acquired by recording the intensity ratio of two portions of the Raman spectrum which were simultaneously sampled from a preset range. The lidar unit employed in this testing consisted of a 4 joule-10ppm laser operating at 694.3 nm, a 10-inch Schmidt-Cassegrain telescope, and a system of time-gated detection and signal processing electronics. The detection system processed three return signal wavelength intervals - two intervals along the rotational Raman scattered spectrum and one interval centered at the Rayleigh-Mie scattered wavelength. The wavelength intervals were resolved by using a pellicle beam splitter and three optical interference filters. Raman return samples were taken from one discrete range segment during each test shot and the signal intensities were displayed in digital format. The Rayleigh-Mie techniques. The test site utilized to evaluate this measurement technique encompassed a total path length of 200 meters. Major components of the test site included a trailer-van housing the lidar unit, a controlled environment test zone, and a beam terminator. The control zone which was located about 100 meters from the trailer was 12 meters in length, 2.4 meters in diameter, and was equipped with hinged doors at each end. The temperature of the air inside the zone could be either raised or lowered with respect to ambient air through the use of infrared heaters or a liquid-nitrogen cooling system. Conditions inside the zone were continuously monitored with a thermocouple rake assembly. The test path length was terminated by a 1.2 meter square array of energy absorbing cones and a flat black screen. Tests were initially conducted at strictly ambient conditions utilizing the normal outside air temperatures as a test parameter. These tests provided a calibration of the Raman intensity ratio as a function of' temperature for the particular optical-filter arrangement used in this system while also providing a test of' the theoretical prediction formulated in the design of the system. Later tests utilized zone temperatures above and below ambient to provide temperature gradient data. These tests indicate that ten shots, or one minute of' data acquisition, from a 100 meter range can provide absolute temperature measurements with an accuracy of + 30 C and a range resolution of about 5 meters. Because this measurement accuracy compares well with that predicted for this particular unit, it is suggested that a field-application system could be built with signif'icant improvements in both absolute accuracy and range.

Salzman, Jack A.↗