At least 19 records

Assessment of passively actuated in-situ cyclic surveillance test specimens for advanced non-light water reactors

The use of surveillance specimens was identified in a roadmap (Sims, 2010, ASME HTGR Code Development Roadmap, STP-NU-045, American Society of Mechanical Engineers, New York, NY) developed for the U.S. Nuclear Regulatory Commission for non-light water reactors that are intended to have very long design lives on the order of 500,000 hours. Creep rupture, long term strain accumulation, creep-fatigue damage, and their interaction with environmental effects require significant extrapolation from shorter term tests. Surveillance specimens provide a means for confirmation of these extrapolations in-situ. The effects of cyclic service on creep-fatigue damage would be particularly challenging based on conventional mechanical testing. Proposed herein is a passive cyclic testing methodology that lends itself well to in-situ surveillance applications. The concept is based on utilizing the difference in the thermal expansion coefficient of candidate materials to generate cyclic loading based on operational thermal transients. Prototypical specimen designs are proposed and their in-situ response to representative plant operation are evaluated.

Messner, M. C.↗

Materials Surveillance Development

This presentation is to update DOE at the Molten Salt Program review in May on the work at INL and Argonne National Laboratory on surveillance specimen development. This includes thermal-mechanical testing and test article designs.

36 MATERIALS SCIENCE↗

Preliminary Procedures and Acceptance Criteria for in-situ Structural Materials Surveillance for MSR

This report describes the initial development of the technical basis for a materials surveillance technology that, when fully developed and validated, can be used by stakeholders to develop and implement a materials surveillance program to manage materials degradation during reactor operations. The procedures described in this report aim to bound the detrimental effects of the reactor environment on the creep-fatigue life of the reactor components through materials surveillance. Specifically, the report describes procedures for selecting critical locations within the reactor components for surrogate materials surveillance and the sizing and placements of passively-actuated materials surveillance test articles under development by the US Department of Energy, Advanced Reactor Technologies Program. These test articles apply cyclic thermomechanical load to a surrogate sample of the component structural material passively through thermal expansion mismatch within the articles, without requiring any penetrations in the reactor coolant boundary. The procedures can be used to size materials surveillance test articles so that they will fail before the corresponding structural component. These articles would be exposed to the component operating environment, located to experience a bounding radiation fluence and representative coolant exposure. They can be monitored during reactor operations to ensure that they have not failed under the combination of creep-fatigue damage and environmental degradation. The report describes the key technical decisions and the corresponding rational for using these procedures to provide advanced warning of any impending material failure. An appendix describes the technical basis and the procedure for sizing a family of passively-actuated test articles. Finally, the report describes future work needed to complete the technical basis underlying this materials surveillance technology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fabrication and Testing of Two Passively Actuated Creep-Fatigue Surveillance Test Articles

This report describes the fabrication, testing, and analysis of two families of passively-actuated creep-fatigue test articles. These test articles induce cyclic mechanical load in a test section actuated solely through a mismatch in the thermal expansion coefficient of two materials and driven by a change in the specimen temperature. Test articles of this type could provide material degradation data for a materials surveillance program in future operating molten salt reactors, where variations in the reactor temperature caused by normal or upset cycles would provide the temperature change in the sample. The purpose of the current experimental campaign is to demonstrate the feasibility of fabricating realistically-sized test articles, test the articles under repeated thermal cycling to assess their robustness, particularly the reliability of the bimetallic welds, and collect strain data from instrumented samples to validate the methods used to size the test articles to match key features of the mechanical response of operating reactor components. The thermal cycling tests are ongoing but the test data to date suggests the current test article design is viable, robust, and can be successfully designed to match a target mechanical response. Finally, the report describes preliminary work on welding refractory alloys to 316H stainless steel. Replacing the test article driver material, currently Alloy 617, with a refractory would increase the coefficient of thermal expansion mismatch and support further miniaturization of the test articles.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Corrosion Evaluation of CoCrFeMnNi High-Entropy Alloys (HEAs) for Corrosion Protection of Natural Gas Transmission Pipelines

High-entropy alloys (HEAs), are multicomponent alloys composed of at least five elements with compositions of 5-35 atomic % for each element. These alloys are being investigated for corrosion protection of natural gas transmission pipelines by studying their behavior under aqueous acidic conditions. Electrochemical and immersion experiments were carried out in 3.5 weight % NaCl solution at pH 4 and 40°C. Oxygen was purged out from the solution by using CO2 as stripping gas. The electrochemical experiments included potentiodynamic and electrochemical impedance spectroscopy tests, used to calculate corrosion rates. Potentiodynamic polarization curves, including cyclic voltammograms, were used to explain active, active-passive, and passive regions of these alloys and susceptibility to localized corrosion. Surface characterization of the corroded samples were performed using scanning electron microscopy (SEM) and x-ray diffraction (XRD). The results of the immersion and electrochemical testing indicate that some of the HEAs have better corrosion performance than commercial alloys UNS N10276, UNS K03014, and UNS 31600.

03 NATURAL GAS↗

Thermography inspection for detection and tracking of composite cylinder damage during load testing

Two thermography techniques, passive and active, are used to detect damage initiation and progression in a cyclically loaded composite cylinder. The passive thermography tracks damage progression in real time during cyclic loading. Active flash thermography, using a flash tube enclosed within the cylinder, images delaminations. A differential thermography processing technique eliminates normal material variations and improves sensitivity to and sizing of delaminations. The thermography results were compared to non-immersion ultrasonic results.

42 ENGINEERING↗

Thermography Inspection for Detection and Tracking of Composite Cylinder Damage During Load Testing

Two thermography techniques, passive and active, are used to detect damage initiation and progression in a cyclically loaded composite cylinder. The passive thermography tracks damage progression in real time during cyclic loading. Active flash thermography, using a flash tube enclosed within the cylinder, images delaminations in a cylinder under different loads. A differential thermography processing technique eliminates normal material variations and improves sensitivity to and sizing of delaminations. The thermography results were compared to nonimmersion ultrasonic results.

Zalameda, J. N.↗

Fatigue Life of Postbuckled Structures with Indentation Damage

The fatigue life of composite stiffened panels with indentation damage was investigated experimentally using single stringer compression specimens. Indentation damage was induced on one of the two flanges of the stringer. The experiments were conducted using advanced instrumentation, including digital image correlation, passive thermography, and in-situ ultrasonic scanning. Specimens with initial indentation damage lengths of 37 millimeters to 56 millimeters were tested in fatigue and the effects of cyclic load amplitude and damage size were studied. A means of comparison of the damage propagation rates and collapse loads based on a stress intensity measure and the Paris law is proposed.

Davila, Carlos G.↗

Fatigue Life of Postbuckled Structures with Indentation Damages

The fatigue life of composite stiffened panels with indentation damage was investigated experimentally using single stringer compression specimens. Indentation damage was induced on one of the two flanges of each stringer. The experiments were conducted using advanced instrumentation, including digital image correlation, passive thermography, and in-situ ultrasonic scanning. Specimens with initial indentation damage lengths of 32 millimeters to 56 millimeters were tested quasi-statically and in fatigue, and the effects of cyclic load amplitude and damage size were studied. A means of comparison of the damage propagation rates and collapse loads based on a stress intensity measure and the Paris law is proposed.

Davila, Carlos G.↗

Fatigue Life and Damage Tolerance of Postbuckled Composite Stiffened Structures with Indentation Damage

The fatigue life and damage tolerance of composite stiffened panels with indentation damage are investigated experimentally using single-stringer compression specimens. The indentation damage was induced to one of the two flanges of the stringer of every panel. The advantages of indentation compared to impact are the simplicity of application, less dependence on boundary conditions, better controllability, and repeatability of the imparted damage. The tests were conducted using advanced instrumentation, including digital image correlation, passive thermography, and in situ ultrasonic scanning. Specimens with initial indentation damage ranging between 32 and 56 mm in length were tested quasi-statically and in fatigue, and the effects of cyclic load amplitude and damage size were studied. A means of comparison of the damage propagation rates and collapse loads based on a stress intensity measure and the Paris law is proposed. The stress intensity measure provides the means to compare the collapse loads of specimens with different damage types and damage sizes, while the Paris law is used to compare the damage propagation rates in specimens subjected to different cyclic loads. This approach enables a comparison of different tests and the potential identification of the effects that influence the fatigue lives and damage tolerance of postbuckled structures with defects.

Davila, Carlos G.↗

Initial development of an in-situ, passive material surveillance test article for monitoring high temperature reactor structural components

This report describes the development of a family of passively-actuated surveillance test articles, suitable for use in an in-situ reactor test program monitoring the degradation in structural material properties caused by the reactor environment. The test articles apply creep-fatigue-type cyclic load to a test section driven by changes in the reactor coolant temperature converted to mechanical force by differential thermal expansion. The report describes three types of test articles, all of which apply the load to a 316H test section using Alloy 617 as the driver material. The three types of specimens each serve a unique purpose: (1) initial proof-of-concept, (2) validation of the models used to size the specimens to achieve a given strain range, and (3) demonstration that the articles can be miniaturized for use in an actual operating reactor. In addition to the specimen design, fabrication, and testing, this report describes the outline of two types of in-situ monitoring programs, using the test article. Monitoring programs such as these could be a critical component in gaining regulator acceptance for Molten Salt Reactor (MSR) designs using structural materials for which there is little long-term experimental environmental testing or operating experience available for calibrating the component structural design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Passive eddy-current damping as a means of vibration control in cryogenic turbomachinery

Lateral shaft vibrations produced by a rotating unbalance weight were damped by means of eddy currents generated in copper conductors that were precessing cyclicly in the gap formed by the pole faces of C-shaped, permanent magnets. The damper assembly, which was located at the lower bearing support of a vertically oriented rotor was completely immersed in liquid nitrogen during the test run. The test rotor was operated over a speed range from 800 to 10,000 rpm. Three magnet/conductor designs were evaluated. Experimental damping coefficients varied from 180 to 530 N sec/m. Reasonable agreement was noted for theoretical values of damping for these same assemblies. Values of damping coefficients varied from 150 to 780 N sec/m. The results demonstrate that passive eddy-current damping is a viable candidate for vibration control in cryogenic turbomachinery.

Cunningham, R. E.↗

Aqueous Corrosion Behavior of Cast CoCrFeMnNi Alloy

CoCrFeMnNi high-entropy alloy demonstrates good mechanical properties and can be further strengthened by thermomechanical processes. A sample alloy prepared by vacuum casting in a graphite mold was further investigated for its corrosion resistance. One-millimeter thin strips of cast alloy were used to investigate its corrosion behavior at room temperature. Linear potentiodynamic tests of the alloy in sodium chloride solution confirmed uniform corrosion property comparable to stainless steel AISI 304. However, a positive cyclic hysteresis loop indicated susceptibility to pitting corrosion. In sodium hydroxide solution, metastable pit formation was observed, while sulfuric acid solution passivated the alloy. In both cases, the alloy did not show any spontaneous pitting tendency.

36 MATERIALS SCIENCE↗

Advanced technology lightweight fuel cell program

The potential of the alkaline electrolyte fuel cell as the power source in a multi hundred kilowatt orbital energy storage system was studied. The total system weight of an electrolysis cell energy storage system was determined. The tests demonstrated: (1) the performance stability of a platinum on carbon anode catalyst configuration after 5000 hours of testing has no loss in performance; (2) capability of the alkaline fuel cell to operate to a cyclical load profile; (3) suitability of a lightweight graphite electrolyte reservoir plate for use in the alkaline fuel cell; (4) long life potential of a hybrid polysulfone cell edge frame construction; and (5) long term stability of a fiber reinforced potassium titanate matrix structure. The power section tested operates with passive water removal eliminating the requirement for a dynamic hydrogen pump water separator thereby allowing a powerplant design with reduced weight, lower parasite power, and a potential for high reliability and extended endurance. It is concluded that two perovskites are unsuitable for use as a catalyst or as a catalyst support at the cathode of an alkaline fuel cell.

Martin, R. E.↗

SORCER TEST UTQIAĠVIK DEPLOYMENT FOR IONOGRAMS (STUDI) 2021-2024

The Air Force Research Laboratory (AFRL) has developed a passive broadband radio frequency (RF) receiver, called a Sounder Receiver (SoRcer), as an ionospheric diagnostic instrument. These systems can produce ionospheric specifications to characterize the local ionosphere. The specifications from the SoRcers can then be used to inform data-assimilation models; monitor diurnal, seasonal, or other cyclical changes; and detect irregularities or abnormalities in the ionosphere, such as traveling ionospheric disturbances (TIDs), sporadic E, and spread F.

frequency↗

SoRcer Test Utqiagvik Deployment for Ionograms (STUDI) Field Campaign Report

The U.S. Air Force Research Laboratory (AFRL) has developed a passive broadband radio frequency (RF) receiver, called a Sounder Receiver (SoRcer), as an ionospheric diagnostic instrument. These systems can produce ionospheric specifications to characterize the local ionosphere. The specifications from the SoRcers can then be used to inform data assimilation models; monitor diurnal, seasonal, or other cyclical changes; and detect irregularities or abnormalities in the ionosphere, such as traveling ionospheric disturbances (TIDs), sporadic E, and spread F.

54 ENVIRONMENTAL SCIENCES↗

Dynamics of an experimental two bladed horizontal axis wind turbine with blade cyclic pitch variation

The turbine under study incorporates the combination of two features: the application of blade cyclic pitch variation; and the use of yaw angle control for rotor speed and torque regulation. Due to its emasculation by passive cyclic pitch variation the rotor can be rapidly yawed without encountering gyroscopic and aerodynamic hub moments and without noticeable out of plane excursions. The two bladed upwind rotor is vane stabilized and of very simple and rugged design. The principle was first checked out with a small scale wind tunnel model and then tested in the atmosphere with a 7.6 meter diameter experimental fully instrumented wind turbine driving a 3 phase alternator. The test results are summarized with respect to structural dynamics and yaw dynamics.

Hotenemser, K. H.↗

Electrochemical stability of LiMF6 (M = P, As, Sb) in tetrahydrofuran and sulfolane

The electrochemical stability of LiSbF6 and LiPF6 in aprotic organic solvents has been investigated. Electrochemical studies, conductivity measurements, and open-circuit stability tests were conducted on LiSbF6 in tetrahydrofuran and sulfolane. Cyclic voltammetric studies of SbF6(-) were compared with those of AsF6(-) and PF6(-) anions. Sb(V) was reduced to Sb(III), and then to Sb(0). AsF6(-) was reduced to AsF3, while no reduction of PF6(-) was observed. The reduction products of AsF6(-) and SbF6(-) passivated the glassy carbon electrode, presumably due to LiF precipitation. Peak potentials were observed to shift in the positive direction as a function of concentration. This was accounted for on the basis of a follow-up chemical reaction.

Nanjundiah, C.↗