Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Passive Peak Temperature Monitors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Status of the Optical Dilatometer Method of Evaluating the Peak Irradiation Temperatures of SiC Passive Monitors

The main objective of this project was to conduct a comparative assessment between the optical dilatometer method and resistivity method, using all 10 SiC temperature monitors provided by two Nuclear Science User Facility experiments: BSU-8242 and General Electric Hitachi. Unfortunately, due to multiple delays in acquiring, shipping, and cleaning the SiC temperature monitors, the project was only able to process one (1) SiC temperature monitor during this period. SiC temperature monitor KGT-3357 was evaluated via the optical dilatometer method to determine its peak irradiation temperature. The KGT-3357 sample was from the BSU-8242 experiment and designed for a temperature of 300°C and an exposure of 1 dpa. The optical dilatometer measurements indicated that the KGT-3357 SiC temperature monitor’s peak irradiation temperature range was 240–267°C, with sensitivity of approximately ±20°C. Additionally, this temperature range falls within the evaluated melt wire temperature range of 238.6–271.5 °C. The remaining six (6) SiC temperature monitors from the BSU-8242 experiment and three (3) from the General Electric Hitachi experiment will be used in the future work to further validate the optical dilatometer method for measuring SiC peak irradiation temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Additive Manufacturing of Miniaturized Peak Temperature Monitors for In-Pile Applications

Passive monitoring techniques have been used for peak temperature measurements during irradiation tests by exploiting the melting point of well-characterized materials. Recent efforts to expand the capabilities of such peak temperature detection instrumentation include the development and testing of additively manufactured (AM) melt wires. In an effort to demonstrate and benchmark the performance and reliability of AM melt wires, we conducted a study to compare prototypical standard melt wires to an AM melt wire capsule, composed of printed aluminum, zinc, and tin melt wires. The lowest melting-point material used was Sn, with a melting point of approximately 230 °C, Zn melts at approximately 420 °C, and the high melting-point material was aluminum, with an approximate melting point of 660 °C. Through differential scanning calorimetry and furnace testing we show that the performance of our AM melt wire capsule was consistent with that of the standard melt-wire capsule, highlighting a path towards miniaturized peak-temperature sensors for in-pile sensor applications.

36 MATERIALS SCIENCE↗

Benchmark Analysis for the Optical Dilatometry Method Using Silicon Carbide Temperature Monitors

The main objective of this project was to conduct a benchmark analysis for the optical dilatometry method by using NSUF’s SiC temperature monitors: two (2) SiC temperature monitors provided by NSUF’s BSU-8242 experiment and two (2) SiC temperature monitors provided by NSUF’s GE-Hitachi experiment. Per the BSU-8242 experiment, KGT-3597 and KGT-3591 had a design temperature of 400°C and an exposure of 3 dpa. Per the GE-Hitachi experiment, KGT-3341 and KGT-3336 had a design temperature of 290°C +/- 50°C and an exposure of 0.5–1 dpa. The KGT-3336 SiC monitor was split into two pieces during the decontamination process, making the dilatometry method the only way to analyze both those pieces. The BSU-8242 monitors revealed peak irradiation temperatures under the design temperature, and the GE-Hitachi monitors revealed peak irradiation temperatures within the design temperature range. The optical dilatometry method measured the peak irradiation temperature of BSU-8242 KGT-3597 to be 330°C, while the resistivity method measured the peak irradiation temperature of BSU-8242 KGT-3591 to be 320°C +/- 20°C. The optical dilatometry method measured the peak irradiation temperatures of the pieces of GE-Hitachi KGT-3336 to be 260°C (for the larger piece) and 220°C (for the smaller piece), while the resistivity method measured the peak irradiation temperature of GE-Hitachi KGT-3341 to be 300°C, with an accuracy range of -50°C to +20°C. Both methods of SiC temperature monitor analysis produced very similar peak irradiation temperatures for each pair of SiC passive monitors from the two experiments, BSU-8242 and GE-Hitachi. The results show dilatometry method to be a reliable and less time-intensive process for determining irradiation temperatures from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive Temperature Sensors for Nuclear Applications

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Passive Temperature Sensors for Nuclear Applications

In April 2007, the Department of Energy (DOE) designated the Advanced Test Reactor (ATR) a National Scientific User Facility (NSUF) to advance US leadership in nuclear science and technology. By attracting new users from universities, laboratories, and industry, this program supports basic and applied nuclear research to help address the nation's energy security needs. In support of this program, the Idaho National Laboratory (INL) established in-house capabilities to develop, fabricate, test, and qualify new and enhanced temperature sensors for irradiation testing. This effort is continuing today through the DOE?s Advanced Sensors and Instrumentation (ASI) program. Although most efforts emphasize sensors capable of providing real-time data, selected tasks have been completed to enhance passive sensors for irradiations where instrumentation leads cannot be included. These sensors include silicon carbide (SiC) monitors, melt wires and the sublime temperature monitor. SiC monitors are available to detect peak irradiation temperatures between 200°C and 800°C in reactor locations where instrumentation leads cannot be used. SiC monitors may be evaluated using specialized equipment installed at INL?s Measurement Sciences Laboratory (MSL). A melt wire inventory is also maintained at MSL. This inventory contains wires for specific use in irradiation experiments ranging in temperatures from 30°C to 1500°C. Melt wires and SiC monitors have had decades of research and application. Recent research has produced a passive monitor known as the sublime temperature monitor. This passive sensor has the capability of recording temperature gradients. This paper will discuss passive temperature sensors currently being researched and implemented under the ASI program.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Underwater thermomagnetic generator for remote marine thermal energy harvesting and sensing

Thermomagnetic generators offer a promising approach for sustainable power generation in remote marine environments. Here, this study presents the design, thermal modeling, and experimental validation of a passively driven underwater thermomagnetic generator developed for powering ocean observation and monitoring sensors. The generator was evaluated under varying working fluids, thermal boundary conditions, and extended operation to assess real-world applicability. Two fluids, deionized water and silicone-based Thermal C5, were tested under simulated shallow- and deep-ocean conditions. Deionized water outperformed Thermal C5, especially in colder environments (~5°C), achieving a peak output of 2.7 mW due to larger temperature gradients and enhanced convective-evaporative heat transfer. Long-duration tests revealed a transient evaporation-condensation cycle that temporarily reduced rotor immersion and performance before stabilizing. The generator powered commercial marine sensors for over 6 h without external batteries, demonstrating the viability of compact, passively cooled thermomagnetic systems for autonomous, off-grid marine sensing.

13 HYDRO ENERGY↗

Development of Bismuth and Platinum Bi-Metallic Nanoparticles to Enhance Melt Wire Temperature Resolution

Advanced manufacturing (AM) based on direct-write (DW) technologies has emerged as the predominant enabler for the fabrication of active and passive sensors to be deployed in harsh operating environments seen in a nuclear reactor. Recently, Idaho National Laboratory and Boise State University have recently established capabilities to incorporate advanced manufacturing (AM) methods to accelerate, modernize and enhance functionality of nuclear sensors and instrumentation to achieve the goal of enhancing the safety and efficiency of nuclear reactors. A significant thrust of this work includes the development of nuclear relevant feedstock materials compatible with a variety of direct-write processes for the development, fabrication and testing of AM sensors for peak temperature detection and neutron flux monitoring. For this report, bismuth and bismuth/platinum (BiPt) bi-metallic nanoparticles were synthesized using wet chemical approaches to develop bi-metallic feedstock materials to enhance the sensitivity of melt wires for peak temperature detection. Nanoparticle characterization was performed with Transmission Electron Microscopy (TEM) for nanoparticle composition and size, Transmission X-Ray Diffraction Fluorescence (TXRF) for nanoparticle composition, and Differential Scanning Calorimetry to elucidate the melting point of BiPt bi-metallic nanoparticles. Preliminary results indicate bi-metallic BiPt nanoparticles as a viable pathway for fabricating high resolution AM melt wires.

36 MATERIALS SCIENCE↗

Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗

WIRE-21 Sensor Irradiation Experiment Ready for HFIR Insertion

The ability to deploy new nuclear fuels for current or future reactor concepts requires a wealth of data regarding fuel performance during normal operation, anticipated operational occurrences, and design-basis accidents. Most of these data have historically been collected during experiments in materials test reactors, ideally with online instrumentation to collect as much data as possible. However, advanced instrumentation could also allow for in situ monitoring of fuel operating conditions during commercial reactor operation to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator understanding of limiting peaking factors. The latter approach would complicate fuel handling, particularly during refueling, unless the instrumentation could be placed inside the fuel rods and transmitted wirelessly to a receiver located outside the fuel’s primary pressure boundary. To this end, Westinghouse Electric Company (WEC) developed wireless sensors based on inductive coupling that can transmit information regarding fuel centerline temperatures and rod internal pressures wirelessly from within a fuel rod to a nearby instrument thimble. After testing these sensors in lower-power university research reactors, the next step is to perform high neutron fluence testing to characterize the performance of these wireless sensors under conditions that are more representative of the intended application—in this case, light-water reactors (LWRs). The removable Be (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) provide the neutron flux, experiment volume, and access to instrument leads required to achieve these sensor testing goals. This report summarizes the design, analysis, and assembly of the Wireless Instrumented RB Experiment 2021 (WIRE-21). This is the most highly instrumented irradiation experiment ever performed in HFIR. The experiment will use seven different sensing techniques to measure temperature, pressure, neutron flux, and neutron fluence during reactor operation. In addition to WEC’s wireless temperature and pressure sensors, WIRE-21 includes an array of thermocouples, self-powered neutron detectors, spatially distributed fiber optic temperature sensors, passive SiC temperature monitors, and flux wires. The design of WIRE-21 and the cabling that was installed in HFIR also provide the infrastructure to enable accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting component temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) that would be expected in the plenum region of LWR fuels, except for the active sensing region of the wireless temperature sensor, which is targeting LWR fuel centerline temperatures (~800–1,100°C). WIRE-21 was successfully assembled, passed all nondestructive examination, and was delivered to HFIR for insertion during upcoming cycle 498 (April 2022).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Frequency‐Locked Wireless Multifunctional Surface Acoustic Wave Sensors

Abstract Surface acoustic waves (SAWs) have shown great potential for developing sensors for structural health monitoring (SHM) and lab‐on‐a‐chip (LOC) applications. Existing SAW sensors mainly rely on measuring the frequency shifts of high‐frequency (e.g., >0.1 GHz) resonance peaks. This study presents frequency‐locked wireless multifunctional SAW sensors that enable multiple wireless sensing functions, including strain sensing, temperature measurement, water presence detection, and vibration sensing. These sensors leverage SAW resonators on piezoelectric chips, inductive coupling‐based wireless power transmission, and, particularly, a frequency‐locked wireless sensing mechanism that works at low frequencies (e.g., <0.1 GHz). This mechanism locks the input frequency on the slope of a sensor's reflection spectrum and monitors the reflection signal's amplitude change induced by the changes of sensing parameters. The proof‐of‐concept experiments show that these wireless sensors can operate in a low‐power active mode for on‐demand wireless strain measurement, temperature sensing, and water presence detection. Moreover, these sensors can operate in a power‐free passive mode for vibration sensing, with results that agree well with laser vibrometer measurements. It is anticipated that the designs and mechanisms of the frequency‐locked wireless SAW sensors will inspire researchers to develop future wireless multifunctional sensors for SHM and LOC applications.

Bo, Luyu↗