Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Passive Monitors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗

Laboratory investigation of hydraulic fracturing in granitic rocks using active and passive seismic monitoring

SUMMARY Knowledge of the fracturing processes can be important for the optimization of pressurized fluid injection operations in the deep underground rock mass. Active and passive seismic monitoring techniques have been used in the field for tracking or mapping the propagating hydraulic fracture. Although both these monitoring techniques provide valuable information about the generated fracture network, it is difficult for either technique to comprehensibly identify the different processes associated with hydraulic fracturing. The combined active and passive monitoring has the potential for better characterization of the complex hydraulic fracturing phenomena. In this study, laboratory hydraulic fracturing experiments with combined active and passive seismic monitoring were conducted on true triaxially loaded Barre granite cubes with different fluid injection rates. The seismic inelastic fracturing was detected by 16 passive acoustic emission sensors, where 3678 and 2370 seismic source events were detected for the high and low injection rate experiments, respectively. For active monitoring, strong variations in the attributes of signals were observed which were transmitted through four source–receiver pairs, placed both perpendicular and parallel to the generated hydraulic fracture. Positive velocity changes were observed for active sensor pairs with ray paths passing through the generated hydraulic fracture indicating fluid permeation, whereas isolated dry deformation was characterized by a slight but permanent velocity decrease. Compared to velocity, the energy of the active signals was 1–2 orders of magnitude more sensitive to different hydraulic fracturing processes. However, the sensitivity and signatures of the active signal attributes were found to be dependent on the frequency range and direction of ray path with respect to the location of the generated fracture network. Using the coupled evaluation of the active and passive signals we were able to systematically identify various hydraulic fracturing processes including: (1) aseismic deformation, (2) fracture initiation and fluid permeation, (3) pressure build-up, (4) fracture propagation and (5) pressure release and leak-off. The results of this study showed that combining the respective advantages of active and passive seismic techniques and using both of them to monitor the failure processes can facilitate a more comprehensive understanding and better control of the hydraulic stimulations in subsurface operations.

Geochemistry & Geophysics↗

An Impedance-Loaded Surface Acoustic Wave Corrosion Sensor for Infrastructure Monitoring

Passive surface acoustic wave (SAW) devices are attractive candidates for continuous wireless monitoring of corrosion in large infrastructures. However, acoustic loss in the aqueous medium and limited read range usually create challenges in their widespread use for monitoring large systems such as oil and gas (O&G) pipelines, aircraft, and processing plants. This paper presents the investigation of impedance-loaded reflective delay line (IL-RDL) SAW devices for monitoring metal corrosion under O&G pipeline-relevant conditions. Specifically, we studied the effect of change in resistivity of a reflector on the backscattered signal of an RDL and investigated an optimal range through simulation. This was followed by the experimental demonstrations of real-time monitoring of Fe film corrosion in pressurized (550 psi) humid CO 2 conditions. Additionally, remote monitoring of Fe film corrosion in an acidic solution inside a 70 m carbon steel pipe was demonstrated using guided waves. This paper also suggests potential ways to improve the sensing response of IL-RDLs.

47 OTHER INSTRUMENTATION↗

Passive Acoustic Monitoring Provides Insights into Avian Use of Energycane Cropping Systems in Southern Florida

Birds are important indicators of ecosystem health and provide a range of benefits to society. It is important, therefore, to understand the impacts of agricultural land use changes on bird populations. The cultivation of energycane (EC)—a sugarcane hybrid—for biofuel production represents one form of agricultural land use change in southern Florida. We used passive acoustic monitoring (PAM) to examine bird community use of experimental EC fields and other agricultural land uses at two study sites in southern Florida. We deployed 16 acoustic recorders in different study plots and used the automatic species identifier BirdNET to identify 40 focal bird species. We found seasonal differences in daily avian species diversity and richness between EC experimental plots and reference agricultural fields (corn fields, orchards, pastureland), and between time periods (pre-planting, post-planting). Daily avian species diversity and richness were lower in the EC experimental plots during Fall and Winter months when plants reached maximum height (>400 cm in some areas). Despite seasonal differences in daily measures of species diversity and richness, we found no differences in cumulative species richness, suggesting that there may be little overall (season-long) effects of EC production. These findings could provide insight to avian seasonal habitat preferences and underscore the potential limitations of PAM in areas experiencing dynamic vegetation changes. More research is needed to better understand if utilization of EC cropping systems results in positive or negative effects on avian populations (e.g., foraging habitat quality, predator–prey dynamics, nest success).

BirdNET↗

Digital twin framework for PIP-II linac: AI-driven multi-scale modeling from ion source to 800 MeV

The PIP-II superconducting linac at Fermilab is designed to deliver multi-megawatt proton beams for neutrino physics and other high-intensity applications. To expedite commissioning and enhance operational reliability, we have developed an EPICS-based data flow framework that seamlessly integrates digital twins (DT) with physical twins (PT). These digital twins comprise high-fidelity beam dynamics models or data-driven surrogate models connected to their physical counterparts through real-time diagnostics and advanced machine-learning algorithms.Central to this framework is Linac_Gen, an accelerated simulation tool that incorporates convolutional neural networks, random forests, and genetic algorithms to provide up to a tenfold speedup in optimizing the accelerator geometry model. An EPICS translator layer ensures interoperability by efficiently mapping lattice parameters across diverse simulation platforms.Our EPICS-based framework supports multiple operational modes—monitoring, passive learning, closed-loop control, and online learning—covering the entire machine lifecycle. By leveraging HPC resources and multi-objective optimization techniques, the digital twin enables adaptive trajectory correction, real-time fault detection, and predictive modeling of beam stability. This comprehensive approach paves the way for robust, high-intensity operation and data-driven accelerator R&D at Fermilab.

Pathak, Abhishek [Fermilab]↗

Passive Acoustic Monitoring of a Riverine Turbine with Stationary Hydrophones

In this study, we characterize the sound generated by a cross-flow riverine turbine in the Kvichak River near Igiugig, Alaska, United States. To do this, we follow the International Electro-technical Commission (IEC) technical specification for characterization of the acoustic emissions from marine energy converters. While marine mammals do not inhabit the test site, the U.S. National Marine Fisheries Service (NMFS) guidelines for assessing the effects of anthropogenic sound on marine mammal hearing were implemented to provide context for the deployment of similar turbines in other areas. The results indicate that turbine sound at the measurement locations was not predicted to be harmful to marine mammals. Results also provide insight into the acoustic characteristics of current energy converters and the complex acoustic propagation in rivers.

13 HYDRO ENERGY↗

Benchmark Analysis for the Optical Dilatometry Method Using Silicon Carbide Temperature Monitors

The main objective of this project was to conduct a benchmark analysis for the optical dilatometry method by using NSUF’s SiC temperature monitors: two (2) SiC temperature monitors provided by NSUF’s BSU-8242 experiment and two (2) SiC temperature monitors provided by NSUF’s GE-Hitachi experiment. Per the BSU-8242 experiment, KGT-3597 and KGT-3591 had a design temperature of 400°C and an exposure of 3 dpa. Per the GE-Hitachi experiment, KGT-3341 and KGT-3336 had a design temperature of 290°C +/- 50°C and an exposure of 0.5–1 dpa. The KGT-3336 SiC monitor was split into two pieces during the decontamination process, making the dilatometry method the only way to analyze both those pieces. The BSU-8242 monitors revealed peak irradiation temperatures under the design temperature, and the GE-Hitachi monitors revealed peak irradiation temperatures within the design temperature range. The optical dilatometry method measured the peak irradiation temperature of BSU-8242 KGT-3597 to be 330°C, while the resistivity method measured the peak irradiation temperature of BSU-8242 KGT-3591 to be 320°C +/- 20°C. The optical dilatometry method measured the peak irradiation temperatures of the pieces of GE-Hitachi KGT-3336 to be 260°C (for the larger piece) and 220°C (for the smaller piece), while the resistivity method measured the peak irradiation temperature of GE-Hitachi KGT-3341 to be 300°C, with an accuracy range of -50°C to +20°C. Both methods of SiC temperature monitor analysis produced very similar peak irradiation temperatures for each pair of SiC passive monitors from the two experiments, BSU-8242 and GE-Hitachi. The results show dilatometry method to be a reliable and less time-intensive process for determining irradiation temperatures from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Material and Design Optimization of Printed Melt Wire Arrays

Recent work conducted by the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory resulted in the establishment of in-house capabilities for fabricating and testing new advanced manufactured sensors for measuring irradiation temperatures inside a nuclear test reactor. Though current methods of real-time temperature monitoring (e.g., thermocouples) can still be used, the complexity of the feedthroughs and attachments needed for collecting real time measurements greatly increases the experiment-related costs. On the other hand, passive monitoring techniques can be used for collecting post irradiation temperature measurements by inferring reactor temperatures, based on the melting points of well-characterized materials (i.e., standard melt wires). However, challenges have arisen due to the limited space available for including instrumentation in experiments. To resolve this issue, the ASI program expanded its temperature detection capabilities to include advance manufactured melt wires for post-irradiation temperature measurements. These melt wires can determine reactor temperatures while also accommodating space limitations in irradiation experiments. To improve performance reliability and enhance melt wire readability following irradiation, FY-22 efforts have focused on optimizing the materials used in the encapsulation and printed melt wire array. This report details the design and fabrication tasks, along with the subsequent x ray computed tomography (XCT) evaluation process. The melt wire array consisted of indium with a melting point of 157°C, indium/silver (96/4 at%) with a melting point of 219°C, and tin with a melting point of 230°C. The encapsulation disc was made of vanadium due to its low activation properties and radiation resistance when deployed in nuclear reactors. Additionally, the melt wire design consisted of a ceramic sublayer (alumina disc) to further enhance the XCT post melting images of the printed melt wires. However, when sealing the vanadium container, all three melt wires melted, reflecting the temperature limitations that must be considered when employing metal containers in the sealing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Geophysical Signatures of Crack Network Coalescence in Rocks at Multiple Length Scales

The main goal of the research project was to identify the geophysical signatures of fracture growth in natural rocks by utilizing novel geophysical techniques. The research objectives were to (a) investigate the potential for geophysical methods to determine when cracks initiate, the types and locations of propagated cracks, and the coalescence of networks of cracks in natural rocks at multiple scales, (b) determine how damage at the microscale evolved into damage at the macroscale and then link the microscopic and macroscopic observations, (c) quantify crack coalescence in rocks under realistic stress conditions using coupled mechanical-geophysical-optical visualization, and (d) identify the precursors in geophysical signals to crack coalescence. The following research thrusts were explored to achieve the research objectives: (1) uniaxial compression testing of rock specimens with and without a set of pre‐existing flaws and (2) triaxial compression testing of natural rock specimens. These thrusts allowed for exploring fracturing in rocks under realistic in situ environments and at multiple scales. This project provided educational opportunities for nine graduate and undergraduate students and resulted in 27 peer-reviewed publications. This first research thrust focused on investigating the micromechanics of fractures in rocks through uniaxial compression testing combined with advanced geophysical and imaging techniques, specifically acoustic emission (AE) monitoring, ultrasonic imaging, and 2-dimensional Digital Image Correlation (2D-DIC). By examining damage processes under time-independent and time-dependent loading conditions, insights into damage localization, crack initiation, and fracturing mechanisms were gained. It was observed that the AE signals and the strain-based measurements directly reflect the state of damage in the rock specimen and could be used to identify the cracking levels, such as the crack initiation (CI) and crack damage (CD), and the mode of deformation. A novel calibration apparatus was developed to enhance the accuracy of AE sensors, allowing for the estimation of key parameters such as magnitude, source dimension, stress drop, and radiated seismic energy associated with the fractures. The findings highlighted significant variations in the temporal evolution of AE source parameters during the primary, secondary, and tertiary stages of creep, identifying tensile cracking as the primary deformation mode. The second research thrust focused on enhancing the understanding of fracturing processes in natural rocks through triaxial compression testing, real-time AE monitoring, and ultrasonic monitoring. We investigated the impact of various factors such as fracture propagation regimes, injection parameters, rock types, and pre-existing conditions on the hydraulic fracture (HF) behavior using scaled true-triaxially loaded specimens of Barre granite and Lyons sandstone. Custom sensor housing facilitated concurrent active and passive monitoring to analyze hydro-mechanical responses and microseismicity associated with different HF scenarios. A coupled investigation of passive microseismicity and active signal attributes permitted a detailed comprehension of the various HF processes (aseismic deformation, fracture initiation and propagation, fluid permeation, and leak-off) and their dependence on the specific rock type. The findings of this research demonstrated the effectiveness of AE monitoring techniques in providing valuable insights into the impact of various factors on the behavior and dynamics of HF processes. The advancements in monitoring techniques, offering a more thorough and precise approach, represent a significant step towards optimizing HF practices and ensuring sustainable resource extraction.

58 GEOSCIENCES↗

Artificial Intelligence-Assisted Daytime Video Monitoring for Bird, Insect, and Other Wildlife Interactions with Photovoltaic Solar Energy Facilities

Studying bird, insect, and other wildlife interactions with photovoltaic (PV) solar energy facilities is difficult due to limited multi-season, multi-site data. Researchers can address such data gaps by combining passive monitoring and artificial intelligence (AI). As a part of the development of AI-enabled avian–solar monitoring software, we collected over 19,000 h of daytime videos at five PV sites across three U.S. regions between 2019 and 2024. We applied a moving object detection and tracking (MODT Version 1) AI model we developed earlier to 4373 h of the footage to extract moving objects in video frames, and human reviewers interpreted the model output and identified 68,646 bird, 25,968 insect, and 169 other wildlife instances to generate the training/validation dataset. We analyzed the data by site, region, and season, considering ground cover and landscapes. Songbirds were most common, with raptors as the next most frequent group. Most notably, no bird collisions were confirmed in our observations collected from the videos. Birds most often flew over or near panels, with the highest observations in the Midwest and Northeast (approximately 30 observations per hour on average) and fewer in the desert Southwest. Other behaviors included perching, foraging, and nesting. Bird abundance peaked during breeding and migration seasons. AI-assisted video monitoring proved effective for non-invasively studying flying wildlife at solar facilities to inform ecologically mindful energy development.

avian mortality↗

Eddy covariance towers as sentinels of abnormal radioactive material releases

Ensuring accurate detection and attribution of abnormal releases of radioactive material is critical for protecting human health and safety. Most commonly, such detection is accomplished via active monitoring approaches involving the collection of physical samples. Further, this is labor intensive and limits the temporal and spatial resolution of any detected events to a relatively coarse level. As an alternative first step towards passive monitoring, we developed an approach using eddy flux tower data records to identify signals from a known abnormal release and quantify the extent to which that signal also occurs at other times in the data record. Through two case studies, one of which targeted the Fukushima nuclear disaster and the other targeting an abnormal release event at a radioisotope production facility in Fleurus, Belgium, we tested our approach and identified several potential heretofore unidentified abnormal events that were consistent with atmospheric circulation patterns and/or wind direction from known release sites. Because our approach is relatively simple and is resistant to systematic errors in the observational record, it has broad applicability beyond specific constituents and ecosystem types to identify a wide variety of limited-duration anomalies in flux tower data to ensure human health and industrial safety.

54 ENVIRONMENTAL SCIENCES↗

Powering mCDR with Marine Renewable Energy

This presentation is for a panel that James Niffenegger was invited to speak at called "Powering Marine Carbon Dioxide Removal" (mCDR), which is focused on how marine renewable energy could be used to power the emerging coastal and offshore mCDR industry. James's presentation is focused on the power needs in this field and the areas were marine energy could be advantageous such as in high latitude ocean monitoring, passive seawater pump systems, and powering electrodialysis based mCDR, which can handle highly variable power inputs like those from wave energy.

16 TIDAL AND WAVE POWER↗

Passive Temperature Sensors for Nuclear Applications

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heat pulse testing at monitoring wells to estimate subsurface fluid velocities in geological CO 2 storage

Monitoring the injected CO 2 during geological CO 2 storage (GCS) is essential to assure containment and identify CO 2 leakage. Here in this work, a new approach is introduced to estimate the evolution of the downhole fluid velocity at a monitoring well and identify CO 2 arrival time using in-well heat pulse/tracer test. The proposed technique involves using a downhole heater to generate a series of heat pulses and measuring their corresponding temperature response. The surface temperature of the downhole heater is controlled by the supplied electrical power and the heat loss by convection to the surroundings. Convective heat transfer is well described using Newton's law of cooling in which the temperature difference between the heater and the surrounding fluids drives the heat transfer, for which the convection heat transfer coefficient (h) controls the magnitude of heat loss. Among various factors that control h, it depends on the type of the flowing fluid and its velocity. Through analyzing the measured temperature at different heat pulses, the changes in h - due to mobilization of the in-situ brine or CO 2 arrival - can be estimated. Consequently, the velocity of the flowing fluid across the heater can be obtained. Since heat transfer by convection is sensitive to the type of the surrounding fluid, intrusion of CO 2 can be detected from the relatively higher surface temperature obtained at CO 2 arrival. Churchill and Bernstein (1977)'s correlation is adopted to estimate the change of fluid velocity in terms of the change in h. To demonstrate the validity of the proposed technique, the results are applied and validated against those of COMSOL Multiphysics simulation tool for single-phase brine (before CO 2 arrival) and single-phase CO 2 (after CO 2 arrival). The observed temperature heating is sensitive to the flowing fluid velocity and fluid type. The temperature signal observed at CO 2 arrival is large and easily detectable using temperature monitoring tool which provides reliable indication for tracking CO 2 arrival at monitoring wells compared with passive temperature monitoring. The results obtained using the proposed technique agree very well with the numerical results obtained from the simulation tool with a maximum estimation error of 7 percent.

02 PETROLEUM↗