Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Palomar”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development and test of an IR camera for astronomical observation at the Palomar 200-in. observatory using the NICMOS II array

A NICMOS II array, a NIR (0.80 - 2.6 micron) imaging system, was integrated into the California Institute of Technology Palomar Observatory camera. The Palomar camera system which consists of six discrete subsystems including a focal plane, an electrical interface, data acquisition electronics, a dewar, dewar optics, and the software is described. The performance and calibration data for each subsystem are presented. Emphasis is placed on test data on the focal plane performance.

Bruce, Carl

Three new BL Lacertae objects in the Palomar-Green survey

We have identified three BL Lacertae objects in the Palomar-Green Survey which were previously misclassified as DC white dwarfs, namely PG 1246+586, PG 1424+240, and PG 1437+398. Our reclassification is based on the detection of these objects as x-ray sources in the ROSAT all-sky survey and upon our subsequent detection of intrinsic linearly polarized and variable optical emission from these sources. As a result of the ROSAT survey, the number of identified BL Lac objects in the Palomar-Green catalog of UV excess objects has been doubled. Corrected optical positions are presented for PG 1246+586 and PG 1437+398.

Fleming, Thomas A.

The Palomar Testbed Interferometer

The Palomar Testbed Interferometer (PTI) is a long-baseline infrared interferometer located at Palomar Observatory, California. It was built as a testbed for interferometric techniques applicable to the Keck Interferometer. First fringes were obtained in 1995 July. PTI implements a dual-star architecture, tracking two stars simultaneously for phase referencing and narrow-angle astrometry. The three fixed 40 cm apertures can be combined pairwise to provide baselines to 110 m. The interferometer actively tracks the white-light fringe using an array detector at 2.2 microns and active delay lines with a range of +/-38 m. Laser metrology of the delay lines allows for servo control, and laser metrology of the complete optical path enables narrow-angle astrometric measurements. The instrument is highly automated, using a multiprocessing computer system for instrument control and sequencing.

Colavita, M. M.

Palomar and Table Mountain Observations of 9P/Tempel 1 during the Deep Impact Encounter: First Results

We present the first results of the Palomar Adaptive Optics observations taken during the Deep Impact encounter with 9P/Tempel 1 in July 2005. We have combined the Palomar near-IR imaging data with our visual wavelength images obtained simultaneously at JPL's Table Mountain Observatory to cover the total wavelength range from 0.4 to 2.3 micrometers in the B, V, R, I, J, H, and K filter bands, spanning the dates from 2005 July 03-07.We also include in our overall analysis images taken on the pre-encounter dates of June 1 and June 15, 2005. The broad wavelength range of our observations, along with high temporal resolution, near-IR sensitivity, and spatial resolution of our imaging, have enabled us to place constraints on the temperature of the impact flash and incandescent plume of greater than 700 K, and to provide mean dust velocities of order 197 +/- 16 m/s approximately 1.25 h after impact derived from our 1.64 micro observations. Our ejected dust mass estimates, as derived from our near-IR observations, are an order of magnitude less than those previously reported for visual wavelength observations.

Comet Tempel-1

A Phase-Shifting Zernike Wavefront Sensor for the Palomar P3K Adaptive Optics System

A phase-shifting Zernike wavefront sensor has distinct advantages over other types of wavefront sensors. Chief among them are: 1) improved sensitivity to low-order aberrations and 2) efficient use of photons (hence reduced sensitivity to photon noise). We are in the process of deploying a phase-shifting Zernike wavefront sensor to be used with the realtime adaptive optics system for Palomar. Here we present the current state of the Zernike wavefront sensor to be integrated into the high-order adaptive optics system at Mount Palomar's Hale Telescope.

adaptive optics

Palomar Testbed Interferometer

The Palomar Testbed Interferometer (PTI) is an infrared, phase-tracking interferometer in operation at Palomar Mountain since July 1995. It was funded by NASA for the purpose of developing techniques and methodologies for doing narrow-angle astrometry for the purpose of detecting extrasolar planets.

optical

The Palomar Adaptive Optics System

Currently under construction at the Jet Propulsion laboratory, the Palomar Adaptive Optics System (PALAO) is a Cassegrain-mounted system for infrared astronomy incorporating active laser metrology to minimize the effects of mechanical flexure.

Palomar Adaptive Optics System palomar optics PALA

Slow-Speed Supernovae from the Palomar Transient Factory: Two Channels

Since the discovery of the unusual prototype SN 2002cx, the eponymous class of low-velocity, hydrogen-poor supernovae has grown to include at most another two dozen members identified from several heterogeneous surveys, in some cases ambiguously. Here we present the results of a systematic study of 1077 hydrogen-poor supernovae discovered by the Palomar Transient Factory, leading to nine new members of this peculiar class. Moreover we find there are two distinct subclasses based on their spectroscopic, photometric, and host galaxy properties: The "SN 2002cx-like" supernovae tend to be in later-type or more irregular hosts, have more varied and generally dimmer luminosities, have longer rise times, and lack a Ti II trough when compared to the \SN 2002es-like" supernovae. None of our objects show helium, and we counter a previous claim of two such events. We also find that these transients comprise 5.6+17 -3:7% (90% confidence) of all SNe Ia, lower compared to earlier estimates. Combining our objects with the literature sample, we propose that these subclasses have two distinct physical origins.

palomar

Dynamical study of the Hilda asteroids. I - Resonant orbital motion of the PLS objects from the Palomar-Leiden Survey

Schubart's (1968) model of a planar elliptic restricted three-body problem is used to study the orbital motion of the Hilda asteroids from the Palomar-Leiden Survey. The 3:2 resonant coupling to Jupiter of some of these small asteroids is found to be stable. However, some of the small asteroids with absolute magnitude greater than 15 have large amplitude of variation in their orbital elements in one libration period. Since the lifetime scales against catastrophic collision of the Hilda asteroids are estimated to be several times larger than those of the main-belt objects, a significant portion of these resonant asteroids could be the original members of the Hilda group. From this point of view, it is suggested that such 'size dependence' of resonant orbital motions might be the result of cosmogonic effects of jet-stream accretion.

Ip, W.-H.

The Palomar planet-crossing asteroid survey, 1973-1978

Photographic coverage of about 80,000 sq deg of sky with the Palomar 46-cm Schmidt camera has yielded 12 new planet-crossing asteroids as well as many objects in the main asteroid belt. The estimated population of planet-crossing asteroids includes approximately 100 Atens, 700 + or- 300 Apollos, 1000-2000 Amors, 10,000 + or- 5000 Mars crossers, and approximately 5000 Mars grazers.

Helin, E. F.

Care, feeding, and use of charge-coupled device /CCD/ imagers at Palomar observatory

The paper describes the optical, mechanical, and electronic properties of the TI and RCA CCDs which have been applied to two-dimensional photometry and spectroscopy at Palomar. The drive, processing, and recording techniques are also discussed, and consideration is given to a focal conversion optical system, the Prime Focus Universal Extragalactic Instrument (PFUEI), which is used to more optimally match the Hale 5 meter plate scale. Calibration and data analysis are also examined.

Gunn, J. E.

Hot subdwarfs in detached binary systems and thick-disk cataclysmic variables from the Palomar-Green survey

A total of 19 stars from the Palomar Green (PG) survey which were found to show composite spectra, generally with a hot subdwarf primary and a cool main-sequence secondary star, are discussed. The primary components have Teff values between 27,000 and 38,000 K (Mv = +5 to +7) and log g = about 6.5, while the secondaries generally show spectral types G8 to K4.5; however, these ranges are undoubtedly limited by selection effects, and extremely helium-rich subdwarfs were excluded as well. Aproximately half of all the PG subdwarfs could be in undetected binaries. Only two thick-disk cataclysmic variables with predominantly absorption-line spectra were found in the PG survey, which provides strong evidence that this kind of cataclysmic variable is luminous and confined to the Galactic plane (Population I). On the other hand, a few of the detached binaries show evidence for spectroscopic variations. Those which are close enough for a significant reflection effect on the secondary star may be progenitors to cataclysmic variable systems.

Ferguson, D. H.

Spectrophotometric and model-atmosphere analyses of the hot DO and DAO white dwarfs from the Palomar-Green survey

Recent optical and spectrophotometric observations of all currently known DAO and DO hot white dwarf candidates from the Palomar-Green Survey are presented. The optical observations were carried out using the Kitt Peak National Observatory Intensified Image Dissector Scanner (IIDS) system, the Multiple Mirror Telescope (MMT), and two photon-counting Reticon systems. Ultraviolet spectrophotometry was obtained using the International Ultraviolet Explorer (IUE) short-wavelength and long-wavelength cameras. The following spectroscopic subgroups were identified in the observations: the cool DO stars with spectra showing H I features together with He II + H blends; the hot DO stars, with spectra exhibiting weak He II (+H) lines; and hydrogen-rich DAO stars with broad H lines and sharp H II lines at 4686 A. A fourth subgroup of stars resembling PG 1159 with He at He II lines at 4686, and a C, N ion blend in the optical spectrum were also found. The spectroscopic data were analyzed in terms of a grid of hot, high-gravity LTE model atmospheres composed of a mixture of hydrogen and helium, and atmospheric parameters are deduced for each class of objects. On the basis of the model atmosphere analysis, the local space density of the DO stars is estimated to be 1.9-3.0 x 10 to the -7th per cubic pc, depending on the scale height.

Wesemael, F.

The Palomar wedge sensitometer

A simple sensitometer for use in providing intensity calibration on photographic plates, which has been in use for many years at Palomar Observatory, is described. External comparison between reduced photographic aperture magnitudes for galaxies and CCD photometry for the same objects shows that use of this device results in proper intensity scales. The intensity scale produced using this instrument also agrees well with that produced by the KPNO spot sensitometers.

Hoessel, J. G.

A catalog of galaxies in Hercules from the Palomar Sky Survey and the Minnesota Automated Plate Scanner

The development of galaxies catalogs from the Palomar Sky Survey using the Minnesota Automated Plate Scanner (APS) is examined. The design and operation of APS are described. The algorithm used to distinguish stars from galaxies is discussed, and the completeness and confusion of the algorithm as a function of magnitude are estimated. The quality of the photometric calibration for galaxy magnitudes and surface-brightness thresholds is evaluated. The relation between the distribution of colors and morphological types is studied. The luminosity functions for Hercules galaxies are calculated and presented. The catalog generated using the APS is 80 percent complete; photometry good to 0.23 mag rms is possible; and J-F colors are good to 0.17 mag rms.

Dickey, John M.