Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Packaging Demonstration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

DOE SNF Packaging Demonstration Project: Worktable and Canister Loading Sleeve Design [Slides]

This presentation is a briefing for summer interns and others outside the project, to give them a summary of ongoing design activities. The DOE SNF Packaging Demonstration Project is an effort to develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed spent nuclear fuel (SNF) for road ready dry storage (RRDS). The project is to remotely load and seal two types of DOE-managed SNF from the CPP-603 facility into DOE Standard Canisters, place the sealed DOE Standard Canisters into commercial vendor over-canisters (equivalent to commercial MPCs), seal and place the over-canisters into commercial vendor storage overpacks, and place the storage system (over-canister and storage overpack) onto the CPP-2707 cask pad.

42 ENGINEERING↗

Code of Record: DOE Standard Canister (DOESC)

The United States Department of Energy (DOE) Spent Nuclear Fuel (SNF) Packaging Demonstration seeks to develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE SNF for road-ready dry storage (RRDS); and establish the processes that will be used in a future production facility. The Packaging Demonstration will utilize the DOE Standard Canister (DOESC) for packaging select DOE-managed SNF types for interim storage, transportation and disposal as part of RRDS. Placing DOE-managed SNF into RRDS is part of the strategic framework for SNF on the Idaho National Laboratory (INL) site. To comply with DOE, INL and Nuclear Regulatory Commission (NRC) requirements, this Code of Record establishes the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC), Section III, Division 3 as the Code that will govern DOESC and internal support structure constructioni, with certain clarifications. This Code of Record establishes a rationale for proceeding without construction certification of the DOESC (i.e., “N-stamping) and the extent to which a Registered Professional Engineer is required for the DOE Spent Fuel Packaging Demonstration. Given the (i) standard industry practice to pursue independent licensure of commercial storage casks and transportation packages by the NRC in lieu of ASME certification and (ii) guidance provided by 10 CFR 830, DOESC construction activities need not be certified (i.e., “stamped”) to the ASME BPVC. However, additional quality assurance requirements will apply as outlined in this Code of Record.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Considerations for Managing DOE Standard Canisters within an Over-canister as Part of an Integrated Waste Management System PPT

To better enable informed decision making regarding the back-end of the nuclear fuel cycle, the Integrated Waste Management Program within the U.S. Department of Energy, Office of Nuclear Energy (DOE-NE) has been sponsoring research into a comprehensive integrated waste management system (IWMS) that considers all major back-end aspects of the nuclear fuel cycle (i.e., transportation, storage, and disposal). An important aspect of the IWMS is DOE-managed Spent Nuclear Fuel (SNF). DOE and its predecessor agencies have generated, transported, received, stored, and reprocessed SNF at DOE facilities nationwide, and DOE is responsible for managing the SNF currently in its possession. These fuels come from a wide range of reactor types that employ various cladding materials, fuel materials, and enrichments. To enable interim, road-ready dry storage (RRDS) of the wide variety of SNF types found in the DOE inventory, a standardized canister system (i.e., the DOE Standard Canister) was proposed for the packaging demonstration. This robust, welded canister system is designed to confine radionuclides, prevent criticality by precluding content moderation, and satisfy other requirements as part of a larger storage, transportation, and disposal system. While SNF has yet to be loaded into a DOE Standard Canister, DOE Standard Canister designs were included in past storage facility and disposal facility design licensing endeavors. In a renewed effort to evaluate packaging SNF at Idaho National Laboratory (INL) in a RRDS configuration, researchers are planning the RRDS Packaging Demonstration. This demonstration is supplemented by analytical structural, criticality, and material compatibility evaluations that support management of SNF in DOE Standard Canisters, taking advantage of past analysis work to the extent possible. One of the largest differences between the current Packaging Demonstration and past analytical evaluations is the inclusion of an over-canister containing multiple DOE Standard Canisters. For the Packaging Demonstration, DOE Standard Canisters loaded with SNF are planned to be placed in a larger diameter over-canister. The sealed over-canister could then be placed in a storage overpack for onsite storage, or in a transportation overpack for shipment to an offsite storage location or disposal site once one becomes available. This paper examines the relevant considerations and provides a preliminary evaluation of integrating the over-canister configuration into the storage, transportation, and disposal processes of the overall waste management system. For storage and transportation, the over-canister can be considered analogous to a multi-purpose canister (MPC) for commercial SNF. For disposal, the DOE Standard Canisters could be removed from the over-canister and placed in a co-disposal waste package with canisters containing vitrified high-level radioactive waste (HLW) similar to configurations examined previously, or the sealed over-canisters might be capable of direct disposal in a waste package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Considerations for Managing DOE Standard Canisters within an Over-canister as Part of an Integrated Waste Management System

To better enable informed decision making regarding the back end of the nuclear fuel cycle, the Integrated Waste Management Program within the U.S. Department of Energy, Office of Nuclear Energy (DOE-NE) has been sponsoring the research into a comprehensive integrated waste management system (IWMS) that considers all major back-end aspects of the nuclear fuel cycle (i.e., transportation, storage, and disposal). An important aspect of the IWMS is DOE-managed SNF. DOE and its predecessor agencies have generated, transported, received, stored, and reprocessed SNF at DOE facilities nationwide, and DOE is responsible for managing the SNF currently in its possession. These fuels come from a wide range of reactor types that employ various cladding materials, fuel materials, and enrichments. To enable interim, road-ready dry storage (RRDS) of the wide variety of SNF types found in the DOE inventory, a standardized canister system (i.e., the DOE Standard Canister) was proposed. This robust, welded canister system is designed to confine radionuclides, prevent criticality by precluding content moderation, and satisfy other requirements as part of a larger storage, transportation, and disposal system. While SNF has yet to be loaded into a DOE Standard Canister, DOE Standard Canister designs were included in past storage facility and disposal facility design licensing endeavors. In a renewed effort to evaluate packaging SNF at Idaho National Laboratory (INL) in a RRDS configuration, researchers are planning the RRDS Packaging Demonstration. This demonstration is supplemented by analytical structural, criticality, and material compatibility evaluations that support management of SNF in DOE Standard Canisters, taking advantage of past analysis work to the extent possible. One of the largest differences between the current Packaging Demonstration and past analytical evaluations is the inclusion of an over-canister containing multiple DOE Standard Canisters. For the Packaging Demonstration, DOE Standard Canisters loaded with SNF are planned to be placed in a larger diameter over-canister. The sealed over-canister could then be placed in a storage overpack for onsite storage, or in a transportation overpack for shipment to an offsite storage location or disposal site once one becomes available. This paper examines the relevant considerations and provides a preliminary evaluation of integrating the over-canister configuration into the storage, transportation, and disposal processes of the overall waste management system. For storage and transportation, the over-canister can be considered analogous to a multi-purpose canister (MPC) for commercial SNF. For disposal, the DOE Standard Canisters could be removed from the over-canister and placed in a co-disposal waste package with canisters containing vitrified HLW similar to configurations examined previously, or the sealed over-canisters might be capable of direct disposal in a waste package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of 3D Plus Packaging Test Structures for NASA Goddard Space Flight Center

Environmental tests were performed on packaging test structures designed and manufactured for ESA and CNES by 3D PLus ELectronics. The design provided circuit elements that acted as thermal, mechanical and moisture sensors. Other design features showed the compatibility of the packaging with chip passives, bare electronic dice and plastic encapsulated microcircuits packaged together in an innovative, stacked multichip module. The NASA GSFC testing augmented long duration testing on the same units carried out by ESA and CNES. The NASA portion demonstrated packaging stability over temperature, in moisture, with voltage stress, in shock and in vibration environments.

Plante, Jeannette↗

Preliminary investigation of a sealed, remotely activated silver-zinc battery

Methods necessary to provide a remotely activated, silver zinc battery capable of an extended activated stand while in a sealed condition were investigated. These requirements were to be accomplished in a battery package demonstrating an energy density of at least 35 watt hours per pound. Several methods of gas suppression were considered in view of the primary nature of this unit and utilized the electroplated dendritic zinc electrode. Amalgamation of the electrode provided the greatest suppression of gas at the zinc electrode. The approach to extending the activated stand capability of the remotely activated battery was through evaluation of three basic methods of remote, multi-cell activation; 1) the electrolyte manifold, 2) the gas manifold and 3) the individual cell. All three methods of activation can be incorporated into units which will meet the minimum energy density requirement.

Wheat, C. G.↗

Deployable antenna demonstration study

A demonstration system and shuttle flight program was defined to demonstrate packaging, transportation, erection, and structural integrity of a large deployable antenna concept. An analysis of deployable antenna requirements indicates that (1) erectable structures are clearly applicable to very high precision (above 50 GHz) antennas (10 to 30 m); (2) deployable structures are light weight, applicable to moderate precision (below 14 GHz) large antennas (up to 300 m); and (3) both deployable and erectable apply to small and large antenna platforms with common utilities.

Thompson, W.↗

JT8D-15/17 High Pressure Turbine Root Discharged Blade Performance Improvement

The JT8D high pressure turbine blade and seal were modified, using a more efficient blade cooling system, improved airfoil aerodynamics, more effective control of secondary flows, and improved blade tip sealing. Engine testing was conducted to determine the effect of these improvements on performance. The modified turbine package demonstrated significant thrust specific fuel consumption and exhaust gas temperature improvements in sea level and altitude engine tests. Inspection of the improved blade and seal hardware after testing revealed no unusual wear or degradation.

Janus, A. S.↗

Determination and representation of electric charge distributions associated with adverse weather conditions

Algorithms are presented for determining the size and location of electric charges which model storm systems and lightning strikes. The analysis utilizes readings from a grid of ground level field mills and geometric constraints on parameters to arrive at a representative set of charges. This set is used to generate three dimensional graphical depictions of the set as well as contour maps of the ground level electrical environment over the grid. The composite, analytic and graphic package is demonstrated and evaluated using controlled input data and archived data from a storm system. The results demonstrate the packages utility as: an operational tool in appraising adverse weather conditions; a research tool in studies of topics such as storm structure, storm dynamics, and lightning; and a tool in designing and evaluating grid systems.

Rompala, John T.↗

Regrowth-Free Mid-Infrared Distributed Feedback Quantum Cascade Lasers with Sub-Watt Power Consumption

We report on room-temperature, continuous-wave operation of single-mode quantum cascade lasers designed for minimal threshold power consumption in the 4 to 10 µm spectral range. Narrow-ridge distributed feedback lasers were developed with plasma-etched sidewall corrugations and infrared-transparent dielectric cladding, enabling fabrication without any epitaxial steps beyond the initial growth of the planar laser wafer. The devices exhibit single-mode emission with stable, mode-hop-free tuning and side-mode suppression greater than 25 dB. We demonstrate packaged single-mode devices with continuous-wave threshold power consumption near 1 W above room temperature.

infrared absorption spectroscopy↗

Criticality Analysis of FSV Spent Nuclear Fuel in the DOE Standard Canister

The U.S. Department of Energy (DOE) is responsible for managing over 300 types of spent nuclear fuel (SNF). To manage this large variety of fuel types, DOE plans to employ standardized canisters for the transportation, long-term storage, and eventual disposal of SNF. Idaho National Laboratory is currently supporting DOE’s SNF Packaging Demonstration Project, in which Fort Saint Vrain (FSV) fuel assemblies will be loaded into a DOE Standard Canister. This paper presents criticality calculations demonstrating that all four or five FSV fuel assemblies loaded into the DOE Standard Canister will remain subcritical in any expected normal or credible abnormal conditions. Previous criticality analyses were performed for one FSV fuel assembly and 12 Peach Bottom Core 2 fuel elements loaded into a DOE Standard Canister. This paper covers the criticality analysis performed for loading both four and five FSV fuel assemblies into a DOE Standard Canister. Various intact and degraded mode configurations were modeled in conducting the criticality calculations. This analysis encompassed three different configurations: (1) a single DOE Standard Canister loaded into a concrete storage overpack, (2) seven DOE Standard Canisters loaded into a concrete storage overpack, and (3) nine DOE Standard Canisters loaded into a concrete storage overpack. The overpack dimensions were varied for each of the three configurations, and transport, storage, and disposal scenarios were analyzed for each configuration. For transport scenarios, a pair of degradation cases was analyzed. In the first case, the fuel compacts became degraded and were removed from the fuel block, then deposited at the bottom of a horizontally placed canister, thereby simulating a drop event. The canister was considered to remain intact. In the second case, the spacing between horizontally placed canisters in a nine-canister overpack was reduced such that the canisters were piled on top of each other, simulating a drop event. For this case, no degradation of the canister internals or fuel was considered. For storage scenarios, the water moderator location in the system was varied to enable identification of the most reactive configurations. Dry and wet conditions were analyzed for the fuel materials, canister, and overpack. For disposal scenarios, two degradation cases were analyzed. In the first, the stainless-steel internals of the canister degraded to either hematite or goethite under both dry and wet conditions. In the second case, degraded FSV fuel formed a uranium-water slurry that filled the coolant/void holes. None of the cases presented exceeded the application specific upper subcritical limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration of a Packaged Capacitive Pressure Sensor System Suitable for Jet Turbofan Engine Health Monitoring

In this paper, the development and characterization of a packaged pressure sensor system suitable for jet engine health monitoring is demonstrated. The sensing system operates from 97 to 117 MHz over a pressure range from 0 to 350 psi and a temperature range from 25 to 500 deg. The sensing system consists of a Clapp-type oscillator that is fabricated on an alumina substrate and is comprised of a Cree SiC MESFET, MIM capacitors, a wire-wound inductor, chip resistors and a SiCN capacitive pressure sensor. The pressure sensor is located in the LC tank circuit of the oscillator so that a change in pressure causes a change in capacitance, thus changing the resonant frequency of the sensing system. The chip resistors, wire-wound inductors and MIM capacitors have all been characterized at temperature and operational frequency, and perform with less than 5% variance in electrical performance. The measured capacitive pressure sensing system agrees very well with simulated results. The packaged pressure sensing system is specifically designed to measure the pressure on a jet turbofan engine. The packaged system can be installed by way of borescope plug adaptor fitted to a borescope port exposed to the gas path of a turbofan engine.

Harsh environment↗

MPC solution for optimal load shifting for buildings with ON/OFF staged packaged units: Experimental demonstration, and lessons learned

Small and medium-sized commercial buildings (SMCB) are significant demand response resources, and it is important to develop grid-responsive control algorithms that exploit those resources and create financial benefits for building owners and HVAC service providers. Furthermore, unlike large-sized commercial buildings, there is an opportunity to have universally applicable control solutions for many SMCBs since those buildings have a consistent HVAC system configuration: SMCBs are commonly served by multiple-staged air conditioning units controlled by their own thermostats. Despite the demand response potential and scalability, however, very few control solutions are available for SMCBs. Typical model predictive control (MPC) and heuristic control approaches for cooling load shifting that lower thermostat setpoints before an electric price jump are suitable mainly for large-sized commercial buildings where a continuous capacity modulation is possible, e.g., via dampers in variable air volume terminal units. However, those approaches can cause undesired, high peaks for SMCBs due to the nature of ON/OFF unit staging and narrow thermostat deadbands. This could discourage the use of advanced grid-responsive controls for SMCBs due to the concern of high demand charges, and has to be resolved. This paper presents a MPC solution that overcomes this challenge. It has a hierarchical MPC structure where an upper level MPC is responsible for electrical load shifting in response to an electric price signal while a lower level MPC is responsible for coordinating compressor stages to eliminate unnecessary peaks and follows the setpoints determined by the upper level MPC. In this work, two one-month, comprehensive laboratory tests have been carried out to demonstrate load shifting and cost savings for the algorithm. Interesting trade-offs between energy efficiency and load flexibility were observed and are discussed, and lessons learned for applying MPCs for SMCBs are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review of Pump Package Assembly Anomalies and Demonstration to Gain Motor Controller Replacement Capability

The International Space Station (ISS) generates heat within the US modules from systems used to operate the station, maintain crew health, and conduct science experiments in the orbiting laboratory. The Internal Thermal Control System (ITCS) collects this heat in water loops and transfers it to the external ammonia system for rejection to space. The ITCS uses six Pump Package Assemblies (PPA) as the motive force to circulate the water within the Lab, Node 2, and Node 3 (Node 1 is parasitic to the Lab and Node 3 ITCS loops). In the life of ISS, 3 PPAs have had to be replaced and 2 PPAs are currently showing signs of degradation. The first PPA to fail in 2003 was due to early coolant chemistry issues; the remaining pump failures and current pump degradations are determined to be related to the Pump/Fan Motor Controller (PFMC), with their individual signatures all being unique to this point. The PFMC of one of the failed PPAs was returned and testing confirmed its sub-components to be the root cause of the PPA failure. Due to the relative size and weight of the standalone PFMC in comparison to the integrated assembly, it is desired, from a launch and on-orbit stowage perspective, to replace the PFMC component of the degraded PPA instead of the entire PPA. The PPA was not designed for this capability, so on the ground demonstrations are planned using crew tools to show that the PFMC can be replaced on-orbit while maintaining full functionality. This paper will focus on the signatures of the two most recent PPA failures and the two PPAs showing signs of degradation, in addition to presenting the findings from the PFMC demonstration effort.

Aaron Rodriguez↗

A Review of Pump Package Assembly Anomalies and Demonstration to Gain Motor Controller Replacement Capability

The International Space Station (ISS) generates heat within the US modules from systems used to operate the station, maintain crew health, and conduct science experiments in the orbiting laboratory. The Internal Thermal Control System (ITCS) collects this heat in water loops and transfers it to the external ammonia system for rejection to space. The ITCS uses six Pump Package Assemblies (PPA) as the motive force to circulate the water within the Lab, Node 2, and Node 3 (Node 1 is parasitic to the Lab and Node 3 ITCS loops). In the life of ISS, 3 PPAs have had to be replaced and 2 PPAs are currently showing signs of degradation. The first PPA to fail in 2003 was due to early coolant chemistry issues; the remaining pump failures and current pump degradations are determined to be related to the Pump/Fan Motor Controller (PFMC), with their individual signatures all being unique to this point. The PFMC of one of the failed PPAs was returned and testing confirmed its sub-components to be the root cause of the PPA failure. Due to the relative size and weight of the standalone PFMC in comparison to the integrated assembly, it is desired, from a launch and on-orbit stowage perspective, to replace the PFMC component of the degraded PPA instead of the entire PPA. The PPA was not designed for this capability, so on the ground demonstrations are planned using crew tools to show that the PFMC can be replaced on-orbit while maintaining full functionality. This paper will focus on the signatures of the two most recent PPA failures and the two PPAs showing signs of degradation, in addition to presenting the findings from the PFMC demonstration effort.

Aaron Rodriguez↗

DOE Packaging Certification Program Engineering Class Demonstration Tests

On Thursday August 11, 2022, a series of explosive demonstration tests were conducted at the Sandia National Laboratories 9920 Test Complex for the 2022 DOE Packaging Certification Program Explosives Engineering class. Class participants included both SNL engineering student interns as well as SNL and LANL staff members. The test series was designed by the class instructor, W. Gary Rivera Org. 6626, and 9920 site test engineer, Marissa Martinez Org. 6648, with help from Michelle Chatter Org 6514 and Luke Gilbert Org 6815.

36 MATERIALS SCIENCE↗