Use of a Multiwavelength Pyrometer in Several Elevated Temperature Aerospace Applications

A multiwavelength pyrometer was developed for applications unique to aerospace environments. It was shown to be a useful and versatile technique for measuring temperature, even when the emissivity is unknown. It has also been used to measure the surface temperatures of ceramic zircomia thermal barrier coatings and alumina. The close agreement between pyrometer and thin film thermocouple temperatures provided an independent check. Other applications of the multiwavelength pyrometer are simultaneous surface and bulk temperature measurements of a transparent material, and combustion gas temperature measurement using a special probe interfaced to the multiwavelength pyrometer via an optical fiber. The multiwavelength pyrometer determined temperature by transforming the radiation spectrum in a broad wavelength region to produce a straight line (in a certain spectral region), whose intercept in the vertical axis gives the temperature. Implicit in a two-color pyrometer is the assumption of wavelength independent emissivity. Though the two data points of a two-color pyrometer similarly processed would result immediately in a similar straight line to give the unknown temperature, the two-color pyrometer lacks the greater data redundancy of the multiwavelength pyrometer, which enables it to do so with improved accuracy. It also confirms that emissivity is indeed wavelength independent, as evidenced by a multitude of the data lying on a simple straight line. The multiwavelength pyrometer was also used to study the optical transmission properties of a nanostructured material from which a quadratic exponential functional frequency dependence of its spectral transmission was determined. Finally, by operating the multiwavelength pyrometer in a very wide field of view mode, the surface temperature distribution of a large hot surface was obtained through measurement of just a single radiation spectrum.

Ng, Daniel

Multiwavelength Pyrometer Developed for Use at Elevated Temperatures in Aerospace Applications

Researchers at the NASA Glenn Research Center have developed a unique multiwavelength pyrometer for aerospace applications. It has been shown to be a useful and versatile instrument for measuring the surface temperatures of ceramic zirconia thermal barrier coatings (TBCs) and alumina, even when their emissivity is unknown. The introduction of fiber optics into the pyrometer has greatly increased the ease of using this instrument. Direct comparison of measurements obtained using the pyrometer and thin film thermocouples on a sample provided independent verification of pyrometry temperature measurement. Application of the pyrometer has also included simultaneous surface and bulk temperature measurement in a transparent material, the measurement of combustion gas temperatures in the flames of an atmospheric burner, the measurement of the temperature distribution appearing on a large surface from the recording of just a single radiation spectrum emitted from this nonuniform temperature surface, and the measurement of some optical properties for special aeronautical materials-such as nanostructured layers. The multiwavelength pyrometer temperature is obtained from a radiation spectrum recorded over a broad wavelength region by transforming it into a straight line segment(s) in part or all of the spectral region. The intercept of the line segment(s) with the vertical axis at zero wavelength gives the inverse of the temperature. In a two-color pyrometer, the two data points are also amenable to this analysis to determine the unknown temperature. Implicit in a two-color pyrometer is the assumption of wavelength-independent emissivity. Its two (and minimum) pieces of data are sufficient to determine this straight line. However, a multiwavelength pyrometer not only has improved accuracy but also confirms that the wavelength-independent emissivity assumption is valid when a multitude of data points are shown to lie on a simple straight line.

Ng, Daniel L.

Application of the Self Calibrating Emissivity and/or Transmissivity Independent Multiwavelength Pyrometer in an Intense Ambient Radiation Environment

The NASA self calibrating multiwavelength pyrometer is a recent addition to the list of pyrometers used in remote temperature measurement in research and development. The older one-color, two-color, and the disappearing filament pyrometers, as well as the multicolor and early multiwavelength pyrometers, all do not operate successfully in situations in which strong ambient radiation coexists with radiation originating from the measured surface. In such situations radiation departing from the target surface arrives at the pyrometer together with radiation coming from another source either directly or through reflection. Unlike the other pyrometers, the self calibrating multiwavelength pyrometer can still calibrate itself and measure the temperatures in this adverse environment.

Ng, Daniel

A Self Calibrating Emissivity and/or Transmissivity Independent Multiwavelength Pyrometer

Pyrometer is a favorite method to do remote temperature measurement in research and development. One-color, two-color and the disappearing filament pyrometers are most common, multicolor and multiwavelength pyrometers are being introduced recently. All these pyrometers invariably require, in one form or another, information concerning emissivity, the medium transmissivity, their ratio at some two spectral regions, the instrument's calibration constant, etc. for their operation. This information can come from hand books, from the manufacturer or in some instances, from results of dedicated separate experiments. Often this information is sample or instrument specific. Sometimes this information, though obtained from a special experiment, is obtained using a separate sample rather than the one pursued for temperature measurement. Then, there would be the question of variability from sample to sample and variability from batch to batch in the sample used. Also, previously determined calibrations can change with time, and the only way to reduce uncertainty is to perform the calibration more frequently or even immediately before the experiment. We have developed a multiwavelength pyrometer, which eliminates the need to supply the necessary emissivity and/or transmissivity information and the instrument calibration constants ahead of time. The pyrometer calibrates itself from its first cycle data.

Ng, Daniel

A high-speed spatial (linear) scanning pyrometer: A tool for diagnostics, temperature mapping, and property determinations at high temperatures

Development of a fast spatial scanning pyrometer for temperature measurements above 1500 K is described. The salient features of the pyrometer are: (1) it measures spectral radiance temperature (at 0.65 micron) at 1024 points along a straight line (25 mm long) on the target; (2) it has no moving parts and uses a self-scanning linear array of silicon photodiodes as the detector; (3) its output is recorded digitally every 1 microsec with a full-scale resolution of about 1 part in 4000, permitting performance of a complete cycle of measurements (1024 points) in about 1 ms. Operational characteristics of the pyrometer are given. Examples of measurements of the temperature along rapidly heated (resistive self-heating) specimens (rod, tube, strip) are presented. Potential use of the pyrometer in the experiments, both ground-based and in microgravity, requiring temperature mapping and property distribution of the specimen at high temperatures is discussed.

Cezairliyan, A.

High-resolution surface temperature measurements on rotating turbine blades with an infrared pyrometer

A high-resolution pyrometer was developed and tested on a modified turbine engine. The pyrometer was used to obtain temperature profiles of the viewed surface of turbine blades in the engine at tip speeds up to 366 meters per second. The combination of coherent fiber optics, a silicon avalanche detector, and high-speed electronics enabled surface resolution of a spot diameter of 0.05 centimeter. The data, in the form of temperature profiles, was obtained in near real time as a hard copy output from a computer display terminal. Temperatures measured with the pyrometer and with thermocouples agreed within 2 percent at temperatures between 977 to 1144 K.

Uguccini, O. W.

Near-infrared two-color pyrometer for determining ignition temperatures of metals and metal alloys

A two-color pyrometer has been designed, constructed, and used to measure the ignition temperatures of metals and metal alloys. Cylindrical metal and metal alloy specimens were ignited by a focused cw CO2 laser beam in a cool, static, pure oxygen environment. The pyrometer operates in the near-infrared at two narrow spectral regions, with a nominal bandwidth of 10 nm centered at 0.9051 and 1.06 micron, and has a temperature range from 1000 to 4000 K. In the present design the temperature of a spot, about 0.5 mm in diameter, can be recorded with a maximum time resolution of 25 microseconds and with an accuracy of a few percent. Results of CO2 laser ignition of cylindrical specimens of 6061 aluminum alloy and 302 SS in a pure oxygen environment were obtained from the two-color pyrometer and were compared with those obtained from a thermocouple placed inside the specimen near the laser-irradiated surface.

Nguyen, K.

Laser Pyrometer For Spot Temperature Measurements

Laser pyrometer makes temperature map by scanning measuring spot across target. Scanning laser pyrometer passively measures radiation emitted by scanned spot on target and calibrated by similar passive measurement on blackbody of known temperature. Laser beam turned on for active measurements of reflectances of target spot and reflectance standard. From measurements, temperature of target spot inferred. Pyrometer useful for non-contact measurement of temperature distributions in processing of materials.

Elleman, D. D.

Direct emissivity measurements on liquids and corrections to multi-color pyrometers

Optical pyrometry provides a means for non-contact temperature measurements whose accuracy depends on the accuracy with which specimen emittance is known. Two methods for obtaining the required emittance data are discussed in which the emittance is determined from measurements of the wavelength or polarization dependence of light emitted by the specimen. The spectral technique, multi-color pyrometry, yields apparent values for specimen emittance and temperature from emitted intensity measurements at two or more wavelengths. Emittance corrections cannot be eliminated by increasing the number of spectral intensity measurements required by an n-color pyrometer. Even if this were possible, the accuracy of temperature measurements by n-color pyrometry decreases with n such that pyrometers that require four intensity measurements would be impractical. In contrast, emittance values and corrections for one-color pyrometers can be accurately measured by the polarized light technique. The polarized light technique involves measurement of the degree of polarization for light emitted at an angle of 45 deg to the specimen normal. The reflectivities (r) for light polarized parallel (p) and normal (n) to the plane of emission are related by r(p) = r(n) squared. This leads to a simple relation between the intensity ratio for light emitted in the two polarized states and the emittance, i.e., e(n) = 2 - I(p)/I(n). The true specimen temperature is also obtained if absolute intensities are measured. Delvelopment of the polarized light technique in combination with one-color optical pyrometry is recommended to achieve accurate non-contact temperature measurements on liquids.

Nordine, Paul C.

IR optical fiber-based noncontact pyrometer for drop tube instrumentation

The design of a two color pyrometer with infrared optical fiber bundles for collection of the infrared radiation is described. The pyrometer design is engineered to facilitate its use for measurement of the temperature of small, falling samples in a microgravity materials processing experiment using a 100 meter long drop tube. Because the samples are small and move rapidly through the field of view of the pyrometer, the optical power budget of the detection system is severly limited. Strategies for overcoming this limitation are discussed.

May, R. G.

A sensitive time-resolved radiation pyrometer for shock-temperature measurements above 1500 K

The general design, calibration, and performance of a new high-sensitivity radiation pyrometer are described. The pyrometer can determine time-resolved temperatures (as low as 1500 K) in shocked materials by measuring the spectral radiance of light emitted from shocked solid samples in the visible and near-infrared wavelength range (0.5-1.0 micron). The high sensitivity of the radiation pyrometer is attributed to the large angular aperture (0.06 sr), the large bandwidth per channel (up to 0.1 micron), the large photodiode detection areas (1.0 sq cm), and the small number of calibrated channels (4) among which light is divided.

Boslough, Mark B.

High-speed spatial scanning pyrometer

A high-speed spatial scanning pyrometer has been designed and developed to measure spectral radiance temperatures at multiple target points along the length of a rapidly heating/cooling specimen in dynamic thermophysical experiments at high temperatures (above about 1800 K). The design, which is based on a self-scanning linear silicon array containing 1024 elements, enables the pyrometer to measure spectral radiance temperatures (nominally at 650 nm) at 1024 equally spaced points along a 25-mm target length. The elements of the array are sampled consecutively every 1 microsec, thereby permitting one cycle of measurements to be completed in approximately 1 msec. Procedures for calibration and temperature measurement as well as the characteristics and performance of the pyrometer are described. The details of sources and estimated magnitudes of possible errors are given. An example of measurements of radiance temperatures along the length of a tungsten rod, during its cooling following rapid resistive pulse heating, is presented.

Cezairliyan, A.

Temperature measurement involving nanostructured thermal barrier coating using a multiwavelength pyrometer

It has been reported that erroneous results were obtained when a conventional pyrometer was used to measure the surface temperature of turbine engine components. Temperatures discrepancies were observed in components which were identical, except that one had its measured surface covered by a nanostructured thermal barrier coating (TBC) whereas the other component's surface was not so coated. These components were placed in an identical environment, receiving identical heat fluxes. A pyrometer measured the TBC covered surface hundreds degrees lower. These coatings were about 25 (mu)m thick, consisting of hundreds of layers of finer structures. The TBC's had very low thermal conductivity, heat flux calculations indicated that the temperatures of the coated surface should exhibit much higher temperature than the uncoated surface. Because these coatings were transparent to radiation from the visible to the infrared region, the temperatures measured by the pyrometer should be the temperature of the covered surface. Turbo components' performance and service life depend critically on the temperatures that it would experience; it is therefore important to know accurately and confidently the real surface temperature. Out of these concerns, an investigation into the measurement of nanostructured material surface temperature was carried out.

Ng, Daniel

Temperature Measurement of a Glass Material Using a Multiwavelength Pyrometer

Temperature measurement of a substance that is transparent using the traditional 1-color, 2-color and other pyrometers has been difficult. The radiation detected by pyrometers do not come from a well defined location in the transparent body. The multiwavelength pyrometer developed at the NASA Lewis Research Center can measure the surface temperature of many materials. We show in this paper that it also measures the surface and a bulk subsurface temperature of transparent materials like glass.

Ng, Daniel

Temperature Measurement of Ceramic Materials Using a Multiwavelength Pyrometer

The surface temperatures of several pure ceramic materials (alumina, beryllia, magnesia, yittria and spinel) in the shape of pellets were measured using a multiwavelength pyrometer. In one of the measurements, radiation signal collection is provided simply by an optical fiber. In the other experiments, a 4.75 inch (12 cm) parabolic mirror collects the signal for the spectrometer. Temperature measurement using the traditional one- and two-color pyrometer for these ceramic materials is difficult because of their complex optical properties, such as low emissivity which varies with both temperature and wavelength. In at least one of the materials, yittria, the detected optical emission increased as the temperature was decreased due to such emissivity variation. The reasons for such changes are not known. The multiwavelength pyrometer has demonstrated its ability to measure surface temperatures under such conditions. Platinum electrodes were embedded in the ceramic pellets for resistance measurements as the temperature changed.

Ng, Daniel

Two-Step Calibration of a Multiwavelength Pyrometer for High Temperature Measurement Using a Quartz Lamp

There is no theoretical upper temperature limit for pyrometer application in temperature measurements. NASA Glenn's multiwavelength pyrometer can make measurements over wide temperature ranges. However, the radiation spectral response of the pyrometer's detector must be calibrated before any temperature measurement is attempted, and it is recommended that calibration be done at temperatures close to those for which measurements will be made. Calibration is a determination of the constants of proportionality at all wavelengths between the detector's output (voltage) and its input signals (usually from a blackbody radiation source) in order to convert detector output into radiation intensity. To measure high temperatures, the detectors are chosen to be sensitive in the spectral range from 0.4 to 2.5 micrometers. A blackbody furnace equilibrated at around 1000 C is often used for this calibration. Though the detector may respond sensitively to short wavelengths radiation, a blackbody furnace at 1000 C emits only feebly at very short wavelengths. As a consequence, the calibration constants that result may not be the most accurate. For pyrometry calibration, a radiation source emitting strongly at the short wavelengths is preferred. We have chosen a quartz halogen lamp for this purpose.

Ng, Daniel

Pyrometer

A non-contact pyrometer and method for calibrating the same are provided. The pyrometer includes a radiation sensor configured to measure at least a portion of a radiance signal emitted from a target medium and output a voltage that is a function of an average of the absorbed radiance signal, and an optical window disposed proximate the radiation sensor and configured to control a wavelength range of the radiance signal that reaches the radiation sensor. The pyrometer may further include a reflective enclosure configured to receive the target medium therein, wherein the radiation sensor and the optical window are disposed within the reflective enclosure, an amplifier in communication with an output of the radiation sensor, and a data acquisition system in communication with an output of the amplifier.

Quince, Asia N.

Infrared pyrometer for high resolution surface temperature measurement on rotating turbine blades

A high resolution pyrometer was developed and used to obtain temperature profiles of rotating turbine blades at tip speeds up to 366 meters per second. Surface temperature variations from 920 to 1250 K can be measured and variations over distances of 0.05 cm can be resolved. Temperature profiles were obtained in near real time as hard copies from a computer display terminal. Temperatures measured with the prototype pyrometer and with thermocouples agreed to within 2 percent over the temperature range from 977 to 1144.

Uguccini, O. W.