Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PV reliability testing and standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Reducing module soiling with scalable and robust photocatalytic coatings

The air-glass interface at the front of a photovoltaic (PV) module reflects approximately 4% of incident light, decreasing the potential power output of the module by the same amount. Today’s modules reduce this loss by adding a low-refractive-index (1.25-1.30) SiO2 coating to the sunward side of the module glass; this antireflection coating recovers approximately 3% of the 4% light that would otherwise be lost. While such antireflection coatings work very well on clean, new modules, they do not inhibit soiling—the accumulation of soilants such as dust, pollen, soot, or other foreign material—on the module glass, and soilants reflect and scatter incident light. An improved coating would serve provide not only an antireflection effect, but also an anti-soiling effect. The goal of this project was to develop such a coating and provide a path for it to be manufactured in the U.S. The project successfully designed and fabricated coatings that provided >3% transmittance gain compared to bare glass (matching the performance of commercial antireflection coatings) and displayed anti-soiling behavior in standard laboratory soiling effects. This was achieved by using a Swift Coat proprietary coating deposition technique, aerosol impact-driven assembly (AIDA), to control the porosity and thus refractive index of coatings of photocatalytic materials—such as TiO2—that would otherwise increase (instead of decrease) reflection. These combined antireflection/anti-soiling coatings passed PV industry standard module reliability tests as well as coating-specific abrasion tests, showing that they have the durability needed for decades in the field. Swift Coat scaled the AIDA hardware and deposition process to make mini-modules that were monitored for nearly two years during field tests administered by a third party, as well as demonstrated scaling to the widths of full-sized modules. The fielded mini-modules outperformed reference modules (with commercial antireflection coatings) in two locations, providing a 1% absolute average performance boost and larger increases during periods of heavier soiling. Swift Coat’s cost analysis indicated a coating manufacturing cost below the sales price of today’s antireflection coatings. More than five module manufacturers sampled and assessed the coatings, and three provided letters of support. The coating developed in this project increases the energy output of PV modules, thereby decreasing the cost per kilowatt-hour of solar energy generated. Cheaper solar electricity benefits the public by accelerating the transition to a stable, affordable, carbon-free energy economy. In addition, for select applications in which PV modules are highly visible—such as on residential rooftops—the coating provides an aesthetic benefit because it stays cleaner than today’s modules. Finally, Swift Coat and its prospective customers are U.S. companies, and successful commercialization of this technology will provide U.S. jobs and a secure solar supply chain.

14 SOLAR ENERGY

Uniform Mechanical Loading Can Test for Nonuniform Loading Durability

In this work, we present a method to evaluate the equivalency between any module mechanical loading conditions. The method is developed to address the specific failure mode of glass fracture and is based on Weibull analysis and weakest link theory. It considers the varying stress profile across the module to calculate the probability of glass fracture, which is used as the metric of equivalency. An idealized nonuniform loading scheme is employed to demonstrate the method and introduce the concept of the equivalent uniform load factor: a factor applied to the maximum pressure of the nonuniform load to obtain the equivalent uniform load value. It is demonstrated that this factor is less than unity for all nonuniform load cases considered, including snow and various characters of wind loading. These significant results suggest that uniform loading may be reliably, and practically, employed to evaluate photovoltaic module glass for nonuniform loading durability.

14 SOLAR ENERGY

R&D to Ensure a Scientific Basis for Qualification Tests and Standards (Final Report)

Project return on investment in a photovoltaic (PV) system depends increasingly on maintaining high energy yields, and the system lifetime is a major factor in levelized cost of electricity (LCOE). Thus, the rate of PV deployment and the success of these assets depends upon reliable long-term power generation. The overarching objective of this program is to improve photovoltaic (PV) module reliability via development of tests and standards. Where reliability problems or risk are discovered, we can design tests to ensure that these liabilities don't affect future generations of products. Customers can use these tests to understand which products are susceptible to certain degradation mechanisms, and manufacturers can use the tests to design unwanted characteristics out of their products. The work under this program identifies PV reliability needs, performs characterization that provides scientific understanding of targeted degradation mechanisms, and translates those data into practical and predictive test protocols and standards. Major accomplishments include: A model for polarization-type potential induced degradation (PID-p) was developed and validated against experimental data. NREL is currently leading a new edition of IEC 62804-1 for PID detection. PID-p can cause large losses in current and voltage for some module designs on cloudy days. Finite element modeling (FEM) and experiment was used to determine when cells crack in a module. It was shown that cells in landscape orientation are much more likely to crack than those on portrait orientation. Shortly thereafter, the first products with portrait-oriented cells were introduced. Studies of how to test for light and elevated temperature degradation (LeTID) culminated with the publication of IEC TS 63342. Software to predict the progression of LeTID was developed, validated, and made publicly available. Field validated tests and international standards for durability of PV module coatings abrasion, backsheets, and encapsulants were developed. Examples are IEC 62788-1-1, IEC 62788-2 ED2, IEC TS 62788-7-2, IEC 62788-7-3 ED1, IEC 63209-2. NREL led the development a high-temperature testing technical specification, and published guidelines that enable installers to determine whether higher-temperature testing is needed, simply based on location and mounting configuration. In a number of our case studies, variations in the bills of materials or workmanship have been associated with variations in reliability. These observations emphasize the importance of quality assurance to reliability. A framework for criticality (i.e. Pareto) analysis was developed and published. The framework helps us and other researchers determine what problems should be addressed for reliability research to have the biggest industry impact. NREL continues to participate actively in international standards development and stakeholder engagement activities, including organizing an annual PV Reliability Workshop. These activities are important for ensuring we address issues that are relevant and timely, and that we convey our results to those who may benefit.

14 SOLAR ENERGY

Surface Stress Characterization and Trends in Thermally Strengthened Photovoltaic Module Glass

Simultaneous changes in photovoltaic (PV) module architecture-such as increased area, replacing the polymeric backsheet with a glass backsheet, and reducing glass thickness from 3.2 to 2.0 mm-have resulted in a novel failure called spontaneous glass breakage. Spontaneous glass breakage results in front and/or rear glass failure without any obvious cause. The resulting low-energy fracture patterns have raised concerns about the thermal strengthening in 2.0-mm glass. We present validation of a nondestructive method for measuring the glass surface stress in PV modules. We use a scattered light polariscope to examine the glass properties of 11 modules from 6 solar fields, with and without spontaneous glass breakage. Based on a Mann-Whitney test p-value of 1.4 x 10-6, we conclude that there is a correlation between lower surface stress and susceptibility to spontaneous breakage. A Kendall's Tau test p-value of 2.0 x 10-4 indicates a correlation between increased module area and lower surface stress. We find that 2.0-mm glass can be, and often is, fully tempered (surface stress ≥69 MPa), but inspecting the fracture pattern is not a reliable way to assess the amount of thermal strengthening. A combination of factors, not just surface stress, influences glass breakage.

14 SOLAR ENERGY

Different Damp-Heat-Induced Series Resistance Degradation Behaviors in Fielded Crystalline Silicon Photovoltaic Modules Due to Difference in Bill of Materials

This case study investigates mono-crystalline silicon modules from underperforming portions of a utility-scale photovoltaic power plant. Field-collected I-V curves and electroluminescence imaging suggested that increased series resistance was a primary factor driving module degradation. Selected modules were removed from the field for further analysis, including incremental damp heat accelerated testing, which confirmed a progression in series resistance degradation. Two distinct cell degradation behaviors became apparent during the investigation. Cross-sectional scanning electron microscopy (with elemental analysis) and scanning spreading resistance microscopy identified key differences between the two degradation mechanisms, primarily grid finger width and contact resistance. Additionally, the study highlights the reliability implications of retest requirements in International Electrotechnical Commission 61215 for material changes and how they may have mitigated the degradation observed at this site.

14 SOLAR ENERGY

2024 Photovoltaic Inverter Reliability Workshop Summary Report & Proceedings

The National Renewable Energy Laboratory (NREL) organized the 2024 Photovoltaic Inverter Reliability Workshop on April 11-12, 2024, hosted at NREL's South Table Mountain campus in Golden, Colorado. The workshop was organized around seven key topics, including the present state of inverter reliability; solutions for reliability challenges; life cycle cost and ownership issues; testing, standards, performance, and reliability metrics; data reporting, analytics, and sharing; and the future of PV inverter reliability research. Participants included inverter manufacturers, national laboratory researchers, academics, independent testing laboratories, and more. Over the course of the two-day workshop, attendees arrived at several key priorities and conclusions. This report summarizes these conclusions and then collects presentations from the workshop into a record of the workshop's proceedings.

14 SOLAR ENERGY

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY

Impacts of PV Module Connector Failures on Cost and Performance of Utility Scale Photovoltaic Systems

The reliability, cost and performance of electrical connectors are a concern in all types of electrical systems, and demands on connectors used on photovoltaic (PV) systems include that connectors maintain electrical conductivity and physical strength, endure ultraviolet sunlight and high ambient temperature, and resist moisture and chemical intrusion over a very long (>25 year) performance period. Connector failures increase operation and maintenance (O&M) costs and reduce plant production, but connector failure can also cause safety and liability problems, which are of greater concern. This work results from a three-year collaboration between Sandia National Laboratories (SNL), the Electric Power Research Institute (EPRI), and the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) Solar Energy Technology Office (SETO) under Agreements #39035 and #38531 "Connector Reliability Across the US Solar Sector." a multi-pronged investigation of PV connector health across the US (see https://energy.sandia.gov/pvconnectors/). This report presents derivation of a Techno-Economic Analysis (TEA) that models failure modes and frequencies (how often failure occurs), estimates O&M costs and lost production associated with connector failures, and then calculates the effect that PV module connectors can have on Levelized Cost of Energy (LCOE). The model is informed with initial data from quantitative assessment of failure rates, root causes and mechanisms, in-situ diagnostics and data collection, lab-based forensics, and interviews with PV connector manufacturers and plant operators. SNL conducted site inspections at multiple utility-scale sites in different climates and subjected field samples of new, used, and degraded connectors to visual and electrical characterization. EPRI conducted metallurgical analysis of the pin and sleeve conductors to study failure-induced morphological and compositional changes. There is in general a shortage of statistically valid data, but data from PVROM database maintained by SNL was sufficient to ascertain failure rates and lost production as well as provide qualitative insight in its curated maintenance records. This report details the structure of the mathematical model but the sources of data to inform the model will continue to evolve. Analysis of a 100 MW PV plant is provided as an example of the use of the model, with results indicating that connectors are responsible for Annualized O&M Costs of $\$$71,933/year; Annualized Unit O&M Costs of $\$$0.72/kW/year; that a Reserve Account of $\$$187,220 should be available to fund repairs related to connectors; that connectors add $\$$1,494,004 to the Net Present Value of the O&M Costs (project life); and that O&M related to connectors adds about $\$$0.00088/kWh to the Levelized Cost of Energy. The impact of this model is to provide a tool to make the US solar sector more robust by quantifying and monetizing the reliability risks to utility-scale PV systems posed by poorly installed, mismatched and/or poorly designed and manufactured connectors. The TEA provides a model incorporating failure statistics, O&M cost data, and lost production into a single figure of merit, informing decisions and enabling practitioners to optimize cost and performance trade-offs. Stakeholders include connector manufacturers, system designers and equipment specifiers, standards bodies, installers and O&M providers, investors and insurance underwriters. This report supports continued growth of PV predicated on assurances that properly installed and maintained PV system connectors are safe and reliable. The project team is proposing future work including accelerated testing of connectors and expanding the approach taken here to other PV system components, such as TEA for rapid shut-down devices.

14 SOLAR ENERGY

Standardized nomenclature for photovoltaic connectors

Photovoltaic (PV) systems rely on discrete connectors for the efficient and safe flow of power from module to module and from strings to combiner boxes and inverters. Despite their functional importance, no common nomenclature for PV connectors currently exists, resulting in confusion and miscommunication. Misunderstood terms like "MC4 compatible", "cross-mating", "intermating", "female", and "male" can lead to installation and maintenance errors and compromise system reliability. We believe a standardized terminology will reduce confusion, help support installation best practices, aid in maintenance and repair, inform next-generation designs, and provide a technical basis for improved codes and standards. To that end, we are proposing a standardized glossary for 4 mm PV connectors (the most common type of connector used in PV applications) based on, and validated by, a Sandia National Laboratories' investigation that included the following sources: 1) a comprehensive review of official documents from 20 connector manufacturers, including schematics, datasheets, installation manuals, and catalogs, as well as relevant patents; 2) two rounds of surveys distributed to stakeholders, including connector manufacturers, engineers, asset owners, test labs, and researchers; and 3) visual examination of 25 different models of 4 mm single-pole DC PV connectors to document variations in design and functionality. This work provides a foundation for establishing a clear and consistent terminology for PV connectors that will in turn enable progress toward greater reliability and collaboration across the industry.

14 SOLAR ENERGY

Lessons from the IEC Durability of Adhesion Accelerated Test Sequence

The IEC 62788-1-1 and IEC 63209-2 standards use aging sequences for durability of adhesion in photovoltaic (PV) modules, which may be evaluated using the single cantilever beam (SCB) test. Because the encapsulant forms critical interfaces with the front glass and solar cells, degradation at those interfaces under ultraviolet (UV) exposure, elevated temperature, and humidity can lead to interfacial delamination - compromising the long-term reliability. In this work, adhesion durability of UV-transmitting poly(ethylene-co-vinyl acetate) (EVA) encapsulant to glass and to silicon solar cells is evaluated after sequenced UV and damp heat aging (85C/85%RH). Laminates were prepared using StarPhire solar front glass with thin glass or PERC cells, and two EVA formulations with different concentrations of siloxane coupling agent. Adhesion was quantified by measuring critical debond energy using the SCB method. Both formulations exhibit similar qualitative trends, while different adhesion is observed at the periphery despite the use of low-shrink manufacturing. The results show that while glass/EVA adhesion remains stable or increases after UV exposure and shows only moderate changes after damp heat, the EVA/cell interface exhibits an irreversible loss of adhesion following UV and then damp heat exposure. Although glass/EVA interfaces generally exhibit lower debond energies, the EVA/cell interface is significantly more vulnerable to UV-driven degradation, identifying it as the dominant reliability risk location through early- and intermediate-module life. These results demonstrate that accelerated aging sequences can expose large, interface-specific losses in adhesion durability and underscore the importance of interface engineering for long-term PV module reliability.

14 SOLAR ENERGY

Cybersecurity Standards for Distributed Energy Resources: Gaps and Harmonization Strategy

This report examines cybersecurity standards for Distributed Energy Resources (DERs) in light of their rapid growth and increasing integration into energy systems. It identifies critical gaps in existing frameworks, including inadequate coverage of DER-specific challenges, complexities in implementing comprehensive standards, integration issues with legacy systems, adoption hurdles for newer standards, and a lack of harmonization across regulatory landscapes. The analysis highlights vulnerabilities such as data integrity risks, unauthorized device control, and denial-of-service attacks across various DER technologies like solar PV, wind turbines, energy storage systems, and hydrogen fuel cells. The report proposes a harmonization strategy to address these deficiencies by developing unified cybersecurity requirements, certification programs, and training resources while fostering collaboration among stakeholders such as government agencies, industry groups, DER operators, manufacturers, and research institutions. A phased roadmap is outlined to refine and implement these measures through pilot testing and widespread adoption. Ultimately, the report underscores the urgent need for coordinated efforts to enhance DER cybersecurity and ensure the reliable operation of future energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Qualification testing and electrical measurement experience: A manufacturer's view

ARCO Solar's experiences as a participant in an industry-utility-government environmental qualification team examining photovoltaic devices are discussed. Included is an assessment of the applicability, completeness and appropriateness of the testing procedures and of the acceptance criteria for megawatt-sized procurements for utilities. Like the stand-alone users, the utility industry is interested in obtaining low costs, but additional concerns exist related to reliability and durability, safety, grounding and overall system criteria including performance prediction (related to output power acceptance testing), power quality and dispatchability. For purposes of this first major purchase of photovoltaic modules and panels by the utility industry, there was a carry-over of the JPL specifications. The need exists for futher development, assessement, and selection of qualification and testing standards and evaluation criteria specifically addressing these additional concerns for utility-connected PV power-plant applications.

Arnett, J. C.

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters: Preprint

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop

Controller-Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System With Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). This CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop

Distributed Wind Monitoring Best Practices

Accessible performance and operational data have been identified as a key enabler for distributed wind energy industry advancement. While utility-scale wind turbines benefit from reliable and continuous supervisory control and data acquisition (SCADA)-based monitoring platforms, monitoring of the U.S. fleet of distributed wind (DW) turbines has been more inconsistent, unreliable, and sometime difficult to access. Without fleet monitoring data, the industry will never understand and thus work to improve turbine under-performance and reliability issues. For the DW industry to scale up, attract investors, and boost credibility, fleetwide monitoring must be robust and reliable, select data must be made accessible to stakeholders, and the data must be in a format useful to users. To help move the industry toward a more standardized, accessible stream of monitoring data, this distributed wind monitoring best practices report attempts to cover topics including key monitoring channels, hardware, communication strategies, and accessibility. Strategic engagement with DW original equipment manufacturers (OEMs), service providers, lab and university researchers, testing organization, certification bodies, end users and solar photovoltaic (PV) monitoring experts has enabled a better understanding of the current state-of-the-art of monitoring and aided in articulating this set of best practices that will guide OEMs toward harmonized monitoring strategies, aimed at a future goal of achieving accessible performance and operational data for the entire fleet of U.S. distributed wind turbines.

17 WIND ENERGY

Hardware-in-the-Loop Evaluation for Potential High Limit Estimation-Based PV Plant Active Control

This paper validates the efficacy of an artificial intelligence (AI)-based photovoltaic (PV) plant control and optimization approach in enabling PV plants as accountable grid reliability service providers. The validation is performed in a realistic laboratory controller-hardware-in-the-loop environment, leveraging accurate PV plant modeling and standard industrial communication protocols. Through simulations that account for diverse weather conditions and active control scenarios, the results highlight the superior performance of the AI-based solution in comparison to a state-of-the-art reference-control grouping-based approach. Such a finding contributes to mitigating the risk of overcurtailment and uninstructed deviations of active PV plant controls, and offers practical guidance for its field deployment. Furthermore, it establishes a standardized testing framework for comparing various PV active control strategies.

hardware-in-the-loop

Screening Metal Halide Perovskite Solar Modules for Premature Field Failures

Developing metal halide perovskite (MHP) photovoltaic (PV) devices into reliable large-area solar modules could accelerate global solar energy deployment. Many MHP devices are susceptible to degradation under light and elevated temperature (LT). Published research on LT testing is limited at the module level, and LT testing has not yet been developed for qualification testing of commercial PV products. This report assesses whether results of LT testing at moderately elevated temperatures correlate with those of field-tested modules from the same batch. Six batches of samples from four manufacturers are assessed. It is shown that modules with a robust package that can maintain over 80% of their peak efficiency during LT testing at 55 °C for 100 h are more likely to retain over 80% of their peak efficiency during outdoor operation for 10 weeks. This finding is a step towards developing a validated test protocol that could be incorporated into a qualification standard for the commercialization of MHP PV technologies.

14 SOLAR ENERGY